METREL Earth 2/3, MI 2126 Instruction Manual

Earth 2/3
MI 2126
Instruction Manual
Version 1.0, Code No. 20 750 190
Distributor:
Manufacturer:
METREL d.d. Ljubljanska cesta 77 1354 Horjul Slovenia
web site: http://www.metrel.si e-mail: metrel@metrel.si
Mark on your equipment certifies that this equipment meets the requirements of the EU (European Union) concerning safety and interference causing equipment regulations
© 2005 METREL
No part of this publication may be reproduced or utilized in any form or by any means without permission in writing from METREL.
MI 2126 Earth 2/3 Table of contents
1 Introduction.............................................................................................................4
1.1 General description............................................................................................4
1.2 Warnings............................................................................................................4
1.3 Standards applied..............................................................................................5
2 Instrument description...........................................................................................6
2.1 Instrument casing..............................................................................................6
2.2 Front panel.........................................................................................................6
2.3 Connector panel................................................................................................7
2.4 Base..................................................................................................................7
2.5 Instrument messages........................................................................................8
3 Using instrument....................................................................................................9
3.1 Performing 3-wire measurement........................................................................9
3.2 Performing 2-wire measurement......................................................................11
3.3 General settings...............................................................................................14
4 Maintenance..........................................................................................................16
4.1 Batteries...........................................................................................................16
4.2 Replacing fuse.................................................................................................17
4.3 Cleaning...........................................................................................................17
4.4 Periodic calibration..........................................................................................17
4.5 Service.............................................................................................................17
5 Technical specification........................................................................................18
5.1 Functions.........................................................................................................18
5.2 General characteristics....................................................................................19
6 Standard and optional accessories.....................................................................20
MI 2126 Earth 2/3 Introduction
1 Introduction
We are very pleased to offer a high quality, professional grade test instrument, for performing two- and three-wire earth resistance measurements, on which the estimation of earthing quality is based. The equipment was designed and produced according to many years of experience of producing and dealing with earth resistance and electric installation test equipment.
1.1 General description
Earth 2/3 is a professional, hand–held, battery powered test instrument. It is intended for carrying out earth resistance measurements in accordance with European standard EN 61557 - 5.
The instrument is supplied with all accessories necessary for carrying out the tests.
1.2 Warnings
In order to ensure operator’s safety while carrying out various measurements and tests using the Earth 2/3, as well as to keep the test equipment undamaged, it is necessary to consider the following general warnings:
symbol on the instrument means »Read the Instruction manual with
special care«. The symbol requires an action!
If the test equipment is used in a manner not specified in this instruction
manual, the protection provided by the equipment may be impaired!
Do not use the instrument and accessories if any damage is noticed!
Service intervention or adjustment and calibration procedure must only be
carried out by a competent, authorized person!
Never connect the instrument to high voltage (U > 20 V).
Turn power off and disconnect any measurement accessory connected to
the instrument before opening battery cover.
MI 2126 Earth 2/3 Introduction
1.3 Standards applied
Earth 2/3 instrument is manufactured and tested according to the following regulations, listed below:
Electromagnetic compatibility (EMC)
EN 61326
Electrical equipment for measurement, control and laboratory use – EMC requirements Class B (Hand-held equipment used in controlled EM environments)
Safety (LVD)
EN 61010-1
Safety requirements for electrical equipment for measurement, control and laboratory use – Part 1: General requirements
Functionality
EN 61557-1 EN 61557-5
Electrical safety in low voltage distribution systems – Part 1: General requirements Part 5: Resistance to earth
MI 2126 Earth 2/3 Instrument description
2 Instrument description
2.1 Instrument casing
The instrument is housed in a plastic enclosure, which maintains IP 40 protection class. The casing consists of a main section, which includes the operator's panel and connectors.
2.2 Front panel
The front panel consists of a custom LCD and a keyboard, see the figure below.
1
Earth 23
/
MI 2126
TEST
DISP
234
Figure 1. LCD display and front panel
Legend:
1 Custom LCD. 2 DISP key to display subresults. 3 TEST key to start measurement. 4 ON/OFF key to switch ON and OFF the instrument (auto OFF will occur
automatically after 10 minutes of inactivity).