Metos OCPE 60 Installation Manual

ELECTRIC PASTA COOKER
OCPE 60
10/25 Electric heated Pasta-Cooker (600)
GB
INDEX
INSTALLATION INSTRUCTIONS ---------------------------------------------------------------------- page -- 11
WARNINGS---------------------------------------------------------------------------------------------------------- page -- 11 INSTALLATION ----------------------------------------------------------------------------------------------------- page -- 11
Positioning Assembly In line union of the appliances Electrical connection Earth and unipotential connections Connection to water piping Water draining
START-UP ----------------------------------------------------------------------------------------------------------- page -- 11
Function check Nominal heat input check
ANALYSIS OF SEVERAL FAILURES -------------------------------------------------------------------------------- page -- 11
Heating elements do not heat up Difficult or lacking temperature adjustment
REPLACEMENT OF PARTS SUBJECT TO CHANGE ---------------------------------------------------------------- page -- 12
Heating elements Temperature regulation thermostat Safety thermostat Water filling and drainage tap
USE AND MAINTENANCE --------------------------------------------------------------------------------- page -- 12
WARNINGS ---------------------------------------------------------------------------------------------------------- page -- 12 USE ----------------------------------------------------------------------------------------------------------------- page -- 12
Filling of well Operation Switching off heating Well drainage
CLEANING AND MAINTENANCE ----------------------------------------------------------------------------------- page -- 12 LIST OF PARTS SUBJECT TO CHANGE ---------------------------------------------------------------------------- page -- 12
Electric heated Pasta-Cooker (600) 11/25
– Connect the metallic structure of every electrical
appliance installed to the terminals, marked by the symbol , and located next to the earth terminals (unipotential system).
Connection to the water piping
– Waterfilling with water tap command on the
front side of the appliance. Water inlet pipe
connection ISO 7/1 R3/8. The water supply must be fed at a pressure of between 150 and 250 kPa.
Water draining
– Water drain tap command on the front side of
the appliance. Drain pipe connection: non-
threated Ø 18 mm, sink type siphon joint.
START-UP
Function check
– Start-up the appliance following the instructions
given; check function regularity and make sure that the controls and heating elements are in good working order, testing them with the various function positions.
– The appliance has an internal safety thermostat
that switches the heating elements off when the work thermostat is failing. In case this thermostat cuts off, remove the screw sealing the thermostat access hole on the control panel. Reset the thermostat, pressing with a pointed tool (e.g. slender screwdriver).
Nominal heat input check
– After installation and at each maintenance
intervention check the heat input of the appliance.
– The nominal heat input is stated in the
“Technical data” table.
The appliance operates at the nominal heat input
when the electrical power is the one stated in Table T1. ATTENTION If the power supply value is not within the limits indicated in Table T1, interrupt the operation of the appliance and contact the electricity delivery body.
ANALYSIS OF SEVERAL FAILURES
Heating elements do not heat up
– Check fuse valves – Main switch off – Insufficient power or wrong electrical connection – Regulation thermostat faulty – Safety thermostat activated or faulty.
Diffcult or lacking temperature adjustment
– Regulation thermostat faulty – Wrong connection or heating elements faulty
(replace faulty element).
REPLACEMENT OF PARTS SUBJECT TO CHANGE
IMPORTANT Before carrying out repairs, unplug appliance from mains disconnecting the main
INSTALLATION INSTRUCTIONS
WARNINGS
Installation, adjustments and maintenance of the appliances must be done by authorized installers, in accordance with the safety standards in force.
The manufacturer declines any responsibility if such obligation is not observed.
INSTALLATION
Positioning
– The overall/connection dimensions and the
technical data are stated in the pages in the appendix.
– Install the appliances only in sufficiently aired
rooms.
– Position appliances at least 10 cm from the
nearby walls. Such distance can be less when the walls are incombustible or protected by a thermal insulator.
– The appliances are not suitable for built-in
installation.
Assembly
– Remove the film which protects the external
panels. Any glue remaining on these is to be removed with a suitable solvent.
– Assemble the spacer (if foreseen) by following
the instructions enclosed with the spacer itself.
In line union of the appliances
– Put the appliances next to eachother and level
them at the same height.
– Unite the appliances using the special union
joint-coverings supplied upon request.
Electrical connections
– Appliances are designed to operate at the voltage
indicated on the rating plate.
– Each appliance must be connected to an
independent mains supply of suitable capacity (total power indicated in “Technical data” table) via an input terminal board with flexible rubber cable, insulated at a level not below H07RN-F.
– Make sure that the cables lenght allows for the
live wires to disconnect from terminal block before the yellow/green ground wire, in case of simultaneous pull.
– Automatic cutout omnipolar switches of suitable
capacity (with contacts opening to at least 3 mm) and highly sensitive automatic differential protective devices must be fitted. These must ensure that there is no direct or indirect contact between live components and fault currents and the ground, in accordance with current regulations (maximum admissible leakage current 1 mA/kW).
Earth and unipotential connections
– Appliances must be earthed on terminals marked
with the symbol .
12/25 Electric heated Pasta-Cooker (600)
switch.
Sealed components must not be tampered with.
To reach electrical components, i.e. controls and safety devices, remove control panel .
Heating elements
– Pull out the control knobs and remove control
panel. Disconnect the faulty heating element from inside the well and replace it.
Temperature regulation thermostat
– Pull out the control knobs. Remove the front
control panel. Disconnect and replace the faulty component.
Safety thermostat
– Pull out the control knobs. Remove the front
panel. Remove and disconnect the component to be changed. Extract the bulb (thermostat) from the heating element. Change the faulty component.
Water filling and drainage tap
– Pull out the control knobs. Remove the front
panel of appliance, disconnect and replace the component.
USE AND MAINTENANCE
WARNINGS
Caution , appliance with hot surfaces!
The appliance is for professional use and must be used by trained personnel. It is for the cooking of food. Any other use of the appliance is considered improper. The installation and adaptation to other voltage must be done by qualified and authorized installers. In case of breakdown disconnect the main switch. Sealed components must not be tampered with. For repairs consult only authorized service centres and ask for original spare parts only.
The manufacturer declines any responsability if such obligations are not observed.
Carefully read this booklet and keep it in a safe place. Before using the appliance carefully clean all the surfaces that will come in contact with food.
USE
Filling of well
Close well drain cock, turning control lever to setting . Turn on water feed tap and fill the well up to the indicator notch, turning the control lever to ON.
IMPORTANT Don’t start heating with an empty well!
Operation
To switch on heating of well (pilot lamp on) turn the temperature regulator knob on the desired working position (ex. Max setting to bring water to
boil).
0 off
Min minimum temperature
1, 2, 3, 4 intermediate temperatures
Max maximum temperature (approx.)
Switching off heating
– Turn temperature regulator knob on position 0
(pilot lamp off).
Well drainage
– Open the well drainage tap to position .
CLEANING AND MAINTENANCE
– Before any cleaning operation disconnect the
electrical supply (if present).
– It is necessary to avoid rusty water being in
contact with stainless steel surfaces. Therefore before filling wells with water open water tap and let water flow until it is perfectly clear.
– Clean stainless steel surfaces daily with water
and non abrasive common detergents, rinse well and dry thoroughly.
– Do not use iron scouring pads or chlorate
products.
– Do not use sharp objects which can scratch and
ruin the steel surface.
– Do not use corrosive products to clean the floor
under the appliance. – Do not wash the appliance with water jets. – Before a long period of inactivity disconnect the
main switch. Proceed to its thorough cleaning. – At least twice a year, ask for the intervention of
an authorized technician authorized for checking
the appliance. It is advisable in any case to
stipulate a maintenance contract.
LIST OF PARTS SUBJECT TO REPLACEMENT
– Temperature regulator – Knob for temperature regulator – Safety thermostat – Heating element – Pilot lamp – Water filling tap – Water drainage tap
TEKNISET TIEDOT - TEKNISKA DATA - TECHNICAL DATA
T1
kW
9V3NAC 400VA13
H 07
RN-F
5 x 1,5
Ø
MIN
MAX
mm
12 ÷ 18
V
-
Ø
MIN
MAX
mm
-
H 07
RN-F
-
A
-
MOD.
OCPE-60
Kokonaisteho - Totaleffekt - Total power
ASENNUSKUVA - INSTALLATIONSBILD - INSTALLATION DIAGRAM
(Mitat cm - Mått cm - Measurements cm)
60
3,6
5,2
3,6
6,64
P
9
5,3
60
5,51
5,92
1142,5
6,5
06
6,9
60
4,1
A S
5
7,4
52
49
6,9
8,4
M
1,4
3
8,4
3.5
43
5
4 7,4
4
M
4
P
A S
3
P-M
S A
A Vesiliitäntä - Vattenanslutning - Water inlet ISO 7/1 R3/8 S
Poistovesiliitäntä - Avloppsanslutning - Water outlet Ø 18 mm
M Verkkoliitin - Nätanslutning - El. power connection blocks P
Sähkökaapelin vedonpoisto - Dragavlastare - Electric cable stress relief
KYTKIN KONTAKTORI TURVATERMOSTAATTI ORANSSI MERKKIVALO VERKKOLIITIN VERKKOLIITIN LÄMMITYSVASTUS VERKKOSUODIN
Loading...