a u t o m a t i o n
OPERATING MANUAL
SPRING FEEDER FG
mf automation, Inc.
355 Wyoming Street
Pittsburgh, PA 15211
Phone: 412-488-3488
Fax: 412-488-3498
www.meto-fer.com
04/06/02
PLEASE, SAVE THIS MANUAL FOR FUTURE REFERENCE
Page 1

Function
The spring feeder facilitates the disentangling and feeding of springs. With an airflow, which
is to turn-on or turn-off in a determined rhythm, the springs are spinning in the housing and
disentangled. Springs that are blocked in the output are blown back into the housing by the
airflow. The blown-in air in the housing, which can only escape by the output, conveys the
springs into the conveyor tube. With a supplementary airflow the springs are conveyed to the
output. The control unit is equipped with an automatic cut-in device that switches on the
spring feeder only as required. A ring initiator may effect scanning. Units that are equipped
with a hopper can be filled up automatically. The tappet of the hopper conveys the springs on
the chute by means of a lifting movement in front of the slide. If the drum is empty (is
controlled by a light barrier), the slide is opening automatically; the springs slide into the unit.
As soon as the slide is closed, the unit begins again to work. Simultaneously and without loss
of time, the chute is filled up again with springs by an exactly defined quantity of lifting s.
The process begins again.
Remarks:
The unit is factory set from Meto-Fer for the corresponding springs.
The springs must be clean and dry.
The unit is supplied with a matching nuzzle, tube mount and 2 meter tube.
Operation Instruction
Switch off the unit=> push up the toggle switch
Fill up the drum with springs; ca. 0.3- 0.5 Liter
Connect current supply=> 24V DC
Check slide to make sure it is properly closed
Connect compressed air, set approximately 6 bar
Switch on the unit=> push down the toggle switch (green light on)
If all is switched on correctly and the ring initiator is not initialized, the unit will automatically
start functioning
Page 2

Maintenance
The spring feeder does not need maintenance. It works with oil-fee are. It is recommendable
to clean the housing in scheduled time periods.]
Input/ output points
Input From Output To
12 light barrier Q1 Agitating-ON
13 Slider closed (Q0) Q2 Blow out-ON
14 Slider open (QL) Q3 Slider-ON
17 Ring initiator Q4 Hopper-ON
Q5 Warning light
Who controls what
Factory
Name Function Settings
T1 Agitating time (spinning and dispersion) 0.17 Sec.
T2 Blowing time (blow the spring into the tube) 0.40 Sec.
T3 Pause agitating again (Pause 1) 0.36 Sec.
T4 Opening time when slider is open 1.2 Sec.
T5 Hopper slider 1.2 Sec.
T6 Warning light 0.35 Sec.
T7 Short pause (setting of springs; Pause 2) 0.22 Sec.
T8 Conveyor control 20.0 Sec.
C1 Periodical control of the light barrier 10. Cycle
C2 Filling up of the hopper: § qty. of liftings-1 5 Liftings
C3 Sensibility of the warning lamp 7/10 Cycles
Page 3

Setting of timer and counter
With the integrated control system the Timer T1 (spinning time), T2 (blowing time), T3 (pause
1), T7 (pause 2) as well as the Counter C1 (light barrier) and C2 (filling up) can be changed
during working of the machine. Immediately after confirmation, the changed parameter is
taken on, the optimation becomes very easy and has to be carried out in eight steps. If at the
same time more than one timer or counter are being matched, step 7 is always followed by step
4 and continues as usual (from top to bottom). For leaving the menu, press ESC.
Step Action Effect
1 Press key OK Menu choice
2 Go down with cursor Indicator PARAMETER
twice is flashing
3 Press key OK Picture timer
4 Cursor up or down Choose timer or
counter
5 Cursor to left or right Choose the wished
placed (is flashing)
6 Cursor up or down Change numerical
value to the wished size
7 Press key OK New value is stored
8 Press key ESC twice Standard view
Page 4

Control box wiring diagram
Terminal connections:
Input
24VDC+
Above
Below
Above
Below
Connection
+ + —
Left
above
below
above
below
Ls send+ 2k7_
Above
above
Easy supply
+
Easy supply
Connection right
-
-
I1
Receiver
Slider close
I2
I3
Slider open
I4
Easy Control
below
+
-
-
01
02
I5
03
Ring initiator
I6
I7
04
05
I8
06
I9
07
I10
Output
24VDC-
Easy minus
I11
I12
Above
Connection
— —
RIGHT
08
Above
Below
Above
Below
below
Below
Easy supply
Easy supply
LED
Supply
LED
Supply
Easy supply
PG Input/ output wiring
Input signals
(Sensors)
Terminal1Terminal
Terminal 3 Terminal 4 Terminal 5 Terminal 6 Terminal 7
2
¥ Ring
¥ initiator
¥Lightbarrier
receiver
¥ Lightbarrier
transmitter
Easy supply
¥ Slide
close
Page 5
Spinning
Blow out
Slider
Hopper
¥ Slide
open
Warning light
¥ Slide
¥ Hopper
¥ Warning
¥ Light
Output 24VDC
Output signals
(Valves)
¥ Supply
¥ Corner
¥ Spinning
¥ blow out