Methven warrants this product against manufacturing defects and that it is suitable for use under the general operating conditions specified in this instruction sheet. However, regional regulations apply and may affect your warranty. Please refer to www.methven.com or call customer service for full details.
New Zealand
0800 804 222
Australia
UK
0800 195 1602
www.methven.com
Never use abrasives or abrasive cleaning agents to clean this product. Clean regularly with contamination free warm soapy water and a damp soft cloth.
Periodically the stream shaper should be removed as shown above and cleaned under running water.
*Note: Unrestricted stream shaper and brass nipple not included in some regions.
Care and Cleaning:
Unequal Pressure Installation*:
Cold
Install the brass nipple into the cold inlet hose.
Equal High Pressure (Mains) Installation:
Install mixer as supplied
Unequal Pressure and Equal Low Pressure Installation*:
Remove flow restricted (yellow) stream shaper using cache key. Replace with unrestricted (white) stream shaper.

ISSUE A
Technical Specifications:
Operating Pressure:
Min: 35kPa/0.35bar Max: 1000kPa/10bar* Optimum: 150kPa/1.5bar - 500kPa/5bar
Operating Temperature:
Hot: Max 80°C* Cold: Min 5°C
Inlet Connections:
All ½" BSP
* Regional specific regulations apply. Please refer to your warranty statement at
www.methven.com
SURFACE BASIN MIXER
Installation Guide
Page 2
Hot
Cold
Max 40mm
35mm min 40mm max
1.
2.
3.
4.
5.
6.
Cut a single hole minimum 35mm/maximum 40mm diameter into the mounting surface.
Screw the mounting studs into the bottom of the basin mixer. Insert small o-ring into the groove in the bottom of the mixer. Assemble large o-ring to the bottom of the base plate and assemble to the bottom of the mixer. Connect one hose to the mixer.
Feed the mixer’s hose and mounting studs through the hole cut in the mounting surface, and position the mixer where required.
Insert the remaining flexible hose through the hole in the mounting surface (from the underside) and screw it into the base of the mixer.
Fit the mounting gasket, mounting plate and mounting nuts onto the mounting studs. Tighten in place from under the mounting surface.
Connect the flexible hoses to the hot and cold supplies (hot on the left, cold on the right).
Installation:
Tip: Install product to mounting surface before connecting second hose to mixer.
Stream Shaper
Mounting Gasket
Base Plate
O-ring
O-ring
Mounting Nuts
Flexible Inlet Hoses: Cold Hot
Mounting Studs
Mounting Plate
Correct
Incorrect
Do not stretch or twist hose
DO NOT crush hose or swaged ends
R35mm Min
20mm
IMPORTANT: Please read all of the instructions before installation.
General:
Methven recommends this product is installed by a licensed plumber in compliance with all relevant regional regulations.
Do not hydrostatic test the installation with this mixer installed. Damage to the ceramic cartridge may occur.
All pipe work must be thoroughly flushed prior to the installation of the mixer.
In-line filters must be fitted on both hot and cold supplies to prevent foreign particles damaging the ceramic cartridge.
Do not remove the ceramic cartridge from the mixer when installing.
After installation all connections must be checked for leaks.
All outlets used primarily for personal hygiene shall deliver water at a safe temperature as per regional regulations.
This mixer is not recommended for use in uncontrolled heating systems such as wet-backs or solar heating units unless a suitable tempering valve is fitted.
If limited water flow is experienced, locate aerator and filter washers and clean away foreign material as required.
It is the responsibility of the installer to ensure a waterproof seal is achieved between the product and mounting surface. If in doubt about the quality of the seal, remove the product and reinstall using silicone to ensure a seal is achieved.