Issue D433174
KIRI 3 HOLE WALL FAUCET
INSTALLATION GUIDE
TECHNICAL SPECIFICATIONS
Operating Pressure:
Min 35 kPa, Max 500 kPa.
Recommended installation of a pressure
limiting valve if supply exceeds 500kPa.
Operating Temperature:
Recommended 50°C at the mixer
Hot: Max 80°C.
Cold: Min 5°C.
NB: New Zealand Building Code Clause G12 Water Supplies specifies all outlets used
primarily for personal hygiene shall deliver
water at a safe temperature.
Inlet Connections:
All ½" BSP.
Methven warrants this product against manufacturing defects and that it is suitable for use
under the operating conditions specified in this instruction sheet.
For your warranty please refer to www.methven.com or call Customer Service
New Zealand
0800 804 222
Australia
1300 638 483
USA
1800 975 5409
UK
0800 195 1602

IMPORTANT
Please read all of the instructions before installation
This faucet is designed for equal and unequal pressure systems.
This faucet is not recommended for use in uncontrolled heating systems such as wet-backs or
solar heater units unless a tempering valve is fitted.
All pipe-work must be thoroughly flushed prior to installation of the mixer. In-line filters must
be installed on both hot and cold supplies to prevent foreign particles damaging the ceramic
cartridge.
NOTE: It is the responsibility of the installer to ensure a water proof seal is achieved
between the escutcheon and finished surface of the wall. If in any doubt about the quality
of the seal the escutcheon should be removed and then reinstall using silicon to ensure a
seal is achieved.
Cold handle
Grub screws
Locking Nut
Handle plate
Handle plate O-rings
Faceplate
(optional)
Headworks
Spout adaptor
Breech Set
(250mm ctrs)
2.5mm Allen key
3
4
Distance from mounting stud to front of wall lining:
72-84 mm (with faceplate)
78-90mm (no faceplate)
1
2
Trim to 15mm
(9mm if NOT using faceplate)
Ø 35mm
Ø 25mm
Ø 35mm