Methven warrants this product against manufacturing defects and that it is suitable for use under the general operating conditions specified in this instruction sheet. However, regional regulations apply and may affect your warranty. Please refer to www.methven.com or call customer service for full details.
New Zealand
Australia UK
Care and Cleaning:
ISSUE A
Technical Specifications:
Operating Pressure:
Min: kPa/ bar Max:
kPa/ bar*
Operating Temperature:
Hot: Max °C* Cold: Min
°C
Inlet Connections:
All ½" BSP
* Regional specific regulations apply. Please refer to your warranty statement at www.methven.com
Basin Mixer
Generic Installation Guide
USE PARALLEL FITTINGS ONLY
Page 2
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Cut a single 35mm diameter hole into the mounting surface or use existing hole.
Insert o-ring provided into the groove in the bottom of the base ring.
Unscrew
mounting
nuts and remove
mounting
plate,
mounting
gasket and one flexible inlet hose
if necessary.
Place base ring over hole ensuring that the o-ring remains in place.
Feed hose and
mounting
studs through the base ring and hole in the mounting surface.
Screw second hose into base of mixer if removed in step 3.
Slide
mounting
gasket and
mounting
plate onto
mounting
studs.
Position the mixer as desired.
Tighten mixer body to the mounting surface using the
mounting
nuts supplied.
Please Note:
Make sure the o-ring in the base ring seals completely around the hole in the mounting surface.
Connect the ½” BSP Female hose fittings to the hot and cold supplies. Turn on the water supply and check carefully for leaks. Retighten joints if necessary.
IMPORTANT: Before you begin, turn off the water supply. It is recommended to fit isolation valves to both the hot and cold supply.
Installation:
IMPORTANT: Please read all of the instructions before installation.
General:
Methven recommends this product is installed by a licensed plumber in compliance with all relevant regional regulations.
Do not hydrostatic test the installation with this mixer installed. Damage to the ceramic cartridge may occur.
All pipe work must be thoroughly flushed prior to the installation of the mixer.
In-line filters must be fitted on both hot and cold supplies to prevent foreign particles damaging the ceramic cartridge.
Do not remove the ceramic cartridge from the mixer when installing.
After installation all connections must be checked for leaks.
All outlets used primarily for personal hygiene shall deliver water at a safe tempe
rature as per
regional regulations.
This mixer is not recommended for use in uncontrolled heating systems such as wet-backs or solar heating units unless a suitable tempering valve is fitted.
If limited water flow is experienced, locate aerator and filter washers and clean away foreign material as required.
It is the responsibility of the installer to ensure a waterproof seal is achieved between the product and mounting surface. If in doubt about the quality of the seal, remove the product and reinstall.
Correct
Incorrect
Do not stretch or twist hose
DO NOT crush Hose or swaged Ends
R35mm Min
20mm
Aerator
Key
Hex Key
Base Ring O-ring
Mounting Nut
Flexible
Inlet Hose
Mounting
Plate
Mounting Gasket
Base Ring
Aerator
Handle
Mounting Stud
Aerator
Key
Aerator
Restrictor
Flow restrictor
Valve
Low and Unequal pressure installation only:
Unscrew aerator. Un-clip, remove and discard restrictor. Replace aerator.
Unequal pressure installation only:
Install Restrictor valve nipple to the cold inlet hose and adjust to balance hot and cold water flow.