Methven 02-9358 Installation Guide

Technical Specifications
Minimalist Spring Pull Down
Inlet Connections: All 1/2’ BSP Operating Pressure: 150kPa - 500kPa Operating Temperatures: Recommended hot water supply 50°C, maximum 70°C. AS 3500 requires all hot water supplies to any sanitary fitting to be tempered to 50°C.
Hose Requirements for mixers
The maximum working pressure of the ceramic cartridge is 1000kPa. Do not hydrostatic test the installation with this mixer installed. Damage to the ceramic cartridge may occur.
Sink Mixer with Twin Action Spray
02-9358
Illustration may not reflect actual product shape.
Installation Guide
“In situ” testing
The maximum working pressure of the ceramic cartridge is 1000kPa. Do not hydrostatic test the installation with this mixer installed. Damage to the ceramic cartridge may occur, voiding our warranty.
APR 2017 MA433094
Methven Australia Pty Ltd
ABN 15 104 813 390
Melbourne, Australia
www.methven.com
Please read all of the instructions before installation
Use of this product in non-domestic applications voids warranty. All pipe work must be thoroughly flushed prior to the installation of the mixer. NEFA inline filters must be installed on both hot and cold supplies. Do not remove the ceramic cartridge from the mixer when installing. Damage caused by hydrostatic testing is not covered by our warranty.
www.methven.com
WMKA21870
Installation
NO NAME QTY
1 Mixer body 1 2 Chrome base ring 1 3 Rubber washer 2 4 Plasc spacer 1 5 Brass lock nut 1 6 Cold supply line 1 7 Hot supply line 1 8 Spray nozzle 1 9 Washer 1
1. Suitable diameter hole size through the bench top is 35-38mm. Ensure the thickness of the bench top does not exceed 30mm.
2. Remove the rubber seal washers brass lock nut and plastic spacer.
3. Fit hot and cold supply hoses into mixer body
4. Place the mixer body and hoses through the hole cut in the bench top. (NB: The hoses will need to be placed through the holes one at a time).
5. Fit chrome base ring to mixer body.
We recommend that this product is installed by a licensed plumber.
DRAWING A
6. Secure the faucet using the washer spacers and brass lock nut against the of the bench.
7. Flush pipework thoroughly.
8. Connect the hoses to their respective water supplies (see over page). Two rubber washers are provided for the flexible hose supply conections. Machined nipple ends are required to ensure a seal to the flexible hose nuts and the rubber washers.
THE METHVEN GUARANTEE
The warranty statement shall apply to all tapware & showers supplied by Methven For more information visit www.methven.com THIS WARRANTY ISSUED BY: Methven Australia Pty Ltd, Melbourne Australia
Loading...