Methven 02-4308, 02-4308LP Specifications Sheet

35mm
dia.
Max 40mm
Futura Sink Mixer
02-4308
Cold
Hot
Illustration may not reflect actual product shape.
SEPT 2009 MA43081
Methven Australia Pty Ltd
ABN 15 104 813 390
Melbourne, Australia
www.methven.com
Illustration may not reflect actual product shape.
Installation Guide
IMPORTANT
Please read all of the instructions before installation
www.methven.com
Spec 001 LN:WM K 21726
Technical Specifications Installation
Refer to diagram at right and back.
Inlet Connections: All 1/2’ BSP Operating Pressure: 150kPa - 500kPa Operating Temperatures: Recommended hot water supply 50°C, maximum 70°C. AS 3500 requires all hot water supplies to any sanitary fitting to be tempered to 50°C.
Ceramic Cartridge Adjustment
Do not remove the ceramic cartridge from the body assembly while carrying out the following adjustments. Note, the cartridge is factory set for maximum temperature
Flow control grub screw access hole
Temperature limiting ring
Raised portion of ring to the front of the faucet
1. A single 35mm diameter hole is required in the mounting surface. The mounting surface can be a maximum of 40mm thick.
2. Screw the threaded studs into the base of the mixer.
Insert the O ring into the groove in the bottom of the base ring and fit the base ring to the bottom of the mixer.
3. Insert the flexible hoses through the hole in the mounting surface (from the underside) and screw them into the base of the mixer.
4. Feed the threaded studs through the hole in the mounting surface. Fit the mounting gasket and mounting plate onto the threaded rods.
5. Tighten the mounting nuts to secure the mixer in place.
6. Connect the flexible hoses to the hot and cold supplies (hot on the left, cold on the right).
Hose Requirements for mixers
The maximum working pressure of the ceramic cartridge is 1000kPa. Do not hydrostatic test the installation with this mixer installed. Damage to the ceramic cartridge may occur.
Maximum hot supply (as fitted in faucet) Maximum limitation of hot supply
“In situ” testing
The maximum working pressure of the ceramic cartridge is 1000kPa. Do not hydrostatic test the installation with this mixer installed. Damage to the ceramic cartridge may occur, voiding our warranty.
We recommend that this product is installed by a licensed plumber.
THE METHVEN GUARANTEE
The warranty statement shall apply to all tapware & showers supplied by Methven For more information visit www.methven.com THIS WARRANTY ISSUED BY: Methven Australia Pty Ltd, Melbourne Australia