Methven 01-2381 Installation Guide

Ceramic Cartridge Adjustment
Do not remove the ceramic cartridge from the body assembly while carrying out the following adjustments. Note, the cartridge is factory set for maximum temperature
Minimalist Hi-Rise Sink Mixer
Gooseneck 01-2350
Remove half-dome (if attached)
Flow limiting adjustment
1.5mm Allen key
Mix temperature limiting adjustment
Illustration may not reflect actual product shape.
Installation Guide
IMPORTANT
Please read all of the instructions before installation
Use of this product in non-domestic applications voids warranty. All pipe work must be thoroughly flushed prior to the installation of the mixer. NEFA inline filters must be installed on both hot and cold supplies. Do not remove the ceramic cartridge from the mixer when installing. Damage caused by hydrostatic testing is not covered by our warranty.
WMKA 21005
MAY 2009 MA433097
Methven Australia Pty Ltd
ABN 15 104 813 390
Melbourne, Australia
www.methven.com
www.methven.com
Technical Specifications Installation
Refer to diagram at right and back.
Inlet Connections: All 1/2’ BSP Operating Pressure: 150kPa - 500kPa Operating Temperatures: Recommended hot water supply 50°C, maximum 70°C. AS 3500 requires all hot water supplies to any sanitary fitting to be tempered to 50°C.
Hose Requirements for mixers
The maximum working pressure of the ceramic cartridge is 1000kPa. Do not hydrostatic test the installation with this mixer installed. Damage to the ceramic cartridge may occur.
1. A single 38mm diameter hole is required in the mounting surface. The mounting surface can be a maximum of 40mm thick.
2. Screw the threaded studs into the base of the mixer.
Insert the O ring into the groove in the bottom of the base ring and fit the base ring to the bottom of the mixer.
3. Insert the flexible hoses through the hole in the mounting surface (from the underside) and screw them into the base of the mixer.
4. Feed the threaded studs through the hole in the mounting surface. Fit the mounting gasket and mounting plate onto the threaded rods.
5. Tighten the mounting nuts to secure the mixer in place.
6. Connect the flexible hoses to the hot and cold supplies (hot on the left, cold on the right).
“In situ” testing
The maximum working pressure of the ceramic cartridge is 1000kPa. Do not hydrostatic test the installation with this mixer installed. Damage to the ceramic cartridge may occur, voiding our warranty.
We recommend that this product is installed by a licensed plumber.