Metermann PM55 User Manual [en, de, fr, it]

PM55
Automatic Precision Pocket Meter
Users Manual
Mode d’emploi
Bedienungshandbuch
Manual d’Uso
PN 2153049 August 2004 2004 Meterman Test Tools. All rights reserved. Printed in Taiwan
SELECT
1
4
2
3
SELECT
Press for 2 seconds to turn meter on.
A LCD display B Rotary switch to select functions and to turn the power on or off C SELECT-button to select alternate functions and turn the power
off and on.
D Permanently attached red test lead for positive (+) polarity and
black test lead for ground reference (-)
PM55 Pocket Meter
Contents
Introduction ....................................................................................................2
Safety Information...........................................................................................2
Symbols Used in this Manual........................................................................3
Turning the Meter On and Off ..........................................................................3
Making Measurements ....................................................................................4
AutoTect
Mode...........................................................................................5
Continuity, Audible With Symbolic Display....................................................5
Electric Field EF-Detection, VolTect ............................................................6
Voltage.........................................................................................................8
Resistance...................................................................................................8
Frequency....................................................................................................8
Capacitance..................................................................................................8
V dc, V ac, and Line-Level Hz........................................................................8
Diode...........................................................................................................9
600 ..........................................................................................................9
µA dc and µA ac...........................................................................................9
Product Maintenance.......................................................................................9
Maintenance.................................................................................................9
Cleaning.......................................................................................................9
Troubleshooting.........................................................................................10
Battery Replacement...................................................................................10
Repair...........................................................................................................11
Specifications................................................................................................13
1
Introduction
This unique meter has a full complement of features in a package only 3/8 inch thick, weighing less than 3 oz. for the utmost in shirt-pocket portability. The PM55 is fully autoranging and has an oversized, easy-to­read digital display. With an AutoTect™ feature that enables the meter to detect and display measurements of AC Volts, DC Volts and Resistance. The PM55 offers VolTect™, a built-in non-contact voltage detection of AC voltage. Although very small, this meter is fully UL safety rated to CAT III levels and is UL listed. The Meterman PM55 precision meter includes measurement extras such as capacitance, frequency, DC microamps and safety extras such as transient protection to 4 kV and overload protection to 600 V.
Safety Information
The PM55 Digital Multimeter is certified for cULus and
EN61010-1:2001; CAT II 600 V, CAT III 300 V, class 2 and pollution deg. 2.
This instrument is EN61010-1 certified for Installation Category II
(600 V). It may only be used to make measurements on energy limited circuits within equipment and not directly connected to mains.
This instrument is EN61010-1 certified for Installation Category III
(300 V). It is recommended for use with local level power distribution, appliances, portable equipment, etc., where only smaller transient overvoltages may occur, and not for primary supply lines, overhead lines and cable systems.
Do not exceed the maximum overload limits per function (see
specifications) nor the limits marked on the instrument itself. Never apply more than 600 V between the test lead and earth ground.
Inspect the DMM, test leads and accessories before every use. Do not
use any damaged part.
Never ground yourself when taking measurements. Do not touch
exposed circuit elements or test probe tips.
Do not operate the instrument in an explosive atmosphere.
2
Exercise extreme caution when: measuring voltage >20 V // current >10
mA // AC power line with inductive loads // AC power line during electrical storms // current, when the fuse blows in a circuit with open circuit voltage > 600 V // servicing CRT equipment.
Remove test leads from circuit before opening the case.
Always measure current in series with the load – NEVER ACROSS a
voltage source.
Symbols Used in this Manual
N Battery W Refer to the manual
T Double insulated X Dangerous Voltage F Direct Current J Earth Ground B Alternating Current R Audible tone
Complies with EU
P
directives
Turning the Meter On and Off
Press the SELECT button for approximately 2 seconds to turn the meter
on.
To turn the meter off, press the SELECT button until the display goes
blank.
Underwriter Laboratories,
>
Inc.
3
Making Measurements
All measurements described in this manual use the Red test lead for positive (+) polarity and Black test lead for Ground reference (-) unless otherwise specified
AutoTect mode is the default function in Auto V. position. Press the SELECT button momentarily to select and step through the functions:
• AutoTect
Continuity
EF
ACV
DCV
• Ω
Hz
Cx
• AutoTect
4
Loading...