Meru Networks AP122 User Manual

Meru Networks AP122
Installation Guide
xxx-XXXXX
October 2014
Copyright © Meru Networks, Inc., 2003–2013. All rights reserved.
Other names and brands may be claimed as the property of other
2
Limited Product Warranty
This Limited Product Warranty applies to the original end-user customer of the Meru product which you purchased for your own use, and not for resale (“Product”), from Meru Networks, Inc. (“Meru”) or its authorized reseller (“Reseller”).
Limited Warranties
One-year limited hardware warranty: Meru warrants to you that Meru hardware (other than
Third Party Products as described below) will be free from defects in materials and work­manship for a one-year period after the date of delivery of the applicable product to you from Meru or its Reseller (the “Hardware Warranty Period”). If Meru receives written notice from you of such defects during the Hardware Warranty Period, Meru will, at its option, either repair or replace Meru hardware that Meru determines to be defective. Replacement products may be remanufactured units, and will be warranted for the remainder of the origi­nal Hardware Warranty Period, or if greater, for thirty days from delivery of such replace­ment. Should Meru be unable to repair or replace the Meru hardware, Meru (or its Reseller, as applicable) will refund to you the purchase price of the Product.
90-Day Limited Software Warranty: Meru warrants to you that, for a 90-day period after the
date of delivery of the applicable product to you from Meru or its Reseller (the “Software Warranty Period”), when properly installed and used, (a) the media on which the Meru soft­ware is provided will be free from defects in materials or workmanship; and (b) the Meru software will substantially conform to the functional specifications in the applicable docu­mentation. If Meru receives written notice from you of a b reach of this warranty during the Software Warranty Period and is able to reproduce the defect, Meru will, at its option, either repair or replace the defective Meru software. Should Meru be unable to repair or replace the Meru software, Meru (or its Reseller, as applicable) will refund to you the purchase price of the Product.
Exclusions
The warranty on the Product shall not apply to defects resulting from the following:
3
Alteration or modification of the Product in any way, including without limitation configura-
tion with software or components other than those supplied by Meru or integration with parts other than those supplied by Meru.
Abuse, damage or otherwise being subjected to proble ms ca used by neg ligence or misap-
plication (including without limitation improper or inad equate maintenance or calibration), relocation of the products (including without limitation damage caused by use of other than Meru shipping containers), or use of the products other than as specified in the applicable Meru product documentation (including without limitation incompatible operating envi ron­ments and systems), or improper site preparation or maintenance.
Damage as a result of accidents, extreme power surge, extreme electromagnetic field, acts
of nature or other causes beyond the control of Meru .
Use of the Product with software, interfacing, parts or supplies not supplied by Meru.
The warranty on the Product does not apply if the Product is sold, or in the case of software, licensed, for free for evaluation or demonstration purposes.
Meru expressly disclaims any warranty or obligation to support the Product for all operating environments – for example, as illustration and not limitation, Meru does not warrant or ensure interoperability of the Product with future telecommunication systems or other future software or hardware.
You understand and acknowledge that the Products may generate, use or radiate radio fre­quency energy and may interfere with radio communications and/or radio and television receptions if is not used and/or installed in accordance with the documentation for such prod­ucts. WHILE MERU USES COMMERCIALLY REASONABLE EFFORTS TO ENSURE COM­PLIANCE OF THE PRODUCTS WITH APPLICABLE UNITED STATES FEDERAL COMMUNICATIONS COMMISSION AND PROTECT AGAINST HARMFUL INTERFER­ENCES, YOU ACKNOWLEDGE AND AGREE THAT INTERFERENCES WITH RADIO COM­MUNICATIONS AND/OR RADIO AND TELEVISION RECEPTIONS MAY OCCUR AND THAT MERU WILL NOT BE LIABLE FOR ANY DAMAGES OR INCONVENIENCE BASED ON SUCH INTERFERENCES.
Third Party Products - The above Limited Warranties are exclusive of products manufac­tured by third parties (“Third Party Products”). If such third party manufacturer provides a sep­arate warranty with respect to the Third Party Product, Meru will include such warranty in the packaging of the Meru Product.
Return procedures
To obtain warranty service you must: (a) obtain a return materials authorization number (“RMA#”) from Meru by contacting rmaadmin@merunetworks.com, and (b) deliver the Prod­uct, in accordance with the instructions provided by Meru, along with proof of purchase in the form of a copy of the bill of sale including the Product’s serial number, contact information, RMA# and detailed description of the defect, in either it s origin al pa ckage or p ackaging provid­ing the Product with a degree of protection equivalent to that of the original packaging, to Meru
4
at the address below. You agree to obtain adequate insurance to cover loss or damage to the Product during shipment.
If you obtain an RMA# and return the defective Product as described above, Meru will pay the cost of returning the Product to Meru. Otherwise, you agree to bear such cost, and prior to receipt by Meru, you assume risk of any loss or damage to the Product. Meru is responsible for the cost of return shipment to you if the Meru Product is defective.
Returned products which are found by Meru to be not defective, returned out-of-warranty or otherwise ineligible for warranty service will be repaired or replaced at Meru’s standard charges and shipped back to you at your expense.
At Meru’s sole option, Meru may perform repair service on the Product at your facility, a nd you agree to provide Meru with all reasonable access to such facility and the Product, as required by Meru. On-site repair service may be available and is governed by the specific terms of your purchase.
All replaced parts, whether under warranty or not, are the property of Meru.
Warranty limitations
THE WARRANTIES SET FORTH ABOVE ARE EXCLUSIVE AND NO OTHER WARRANTY, WHETHER WRITTEN OR ORAL, IS EXPRESSED OR IMPLIED BY MERU, TO THE MAXI­MUM EXTENT PERMITTED BY LAW. THERE ARE NO OTHER WARRANTIES RESPECT­ING THE PRODUCT AND DOCUMENTATION AND SERVICES PROVIDED UNDER THIS AGREEMENT, INCLUDING WITHOUT LIMITATION ANY WARRANTY OF DESIGN, MER­CHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE (EVEN IF MERU HAS BEEN INFORMED OF SUCH PURPOSE), TITLE OR AGAINST INFRINGEMENT OF THIRD PARTY RIGHTS. IF ANY IMPLIED WARRANTY CANNOT BE DISCLAIMED UNDER APPLI­CABLE LAW, THEN SUCH IMPLIED WARRANTY SHALL BE LIMITED IN DURATION TO THE HARDWARE AND SOFTWARE WARRANTY PERIODS DESCRIBED ABOVE.
NO AGENT OF MERU IS AUTHORIZED TO ALTER OR EXCEED THE WARRANTY OBLI­GATIONS OF MERU.
MERU SPECIFICALLY DOES NOT WARRANT THAT THE MERU SOFTWARE WILL BE ERROR FREE OR OPERATE WITHOUT INTERRUPTION.
THE REMEDIES IN THIS LIMITED PRODUCT WARRAN TY ARE YOUR SOLE AND EXCLU­SIVE REMEDIES, AND MERU’S SOLE AND EXCLUSIVE LIABILITY, FOR BREACH OF THE HARDWARE OR SOFTWARE WARRANTY SET FORTH ABOVE.
5
Limitations of Liability
You acknowledge and agree that the consideration which you paid to Meru does not include any consideration by Meru of the risk of consequential, indirect or incidental damages which may arise in connection with your use of, or inability to use, the Product. THUS, MERU AND ITS RESELLER WILL NOT BE LIABLE FOR ANY INDIRECT, INCIDENTAL, SPECIAL, PUNI­TIVE OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION LOST PROF­ITS, LOST BUSINESS, LOST DATA, LOSS OF USE, OR COST OF COVER INCURRED BY YOU ARISING OUT OF OR RELATED TO YOUR PURCHASE OR USE OF, OR INABILITY TO USE, THIS PRODUCT OR THE SERVICES, UNDER ANY THEORY OF LIABILITY, WHETHER IN AN ACTION IN CONTRACT, STRICT LIABILITY, TORT (INCLUDING NEGLI­GENCE) OR OTHER LEGAL OR EQUITABLE THEORY, EVEN IF MERU OR ITS RESELLER KNEW OR SHOULD HAVE KNOWN OF THE POSSIBILITY OF SUCH DAMAGES. IN ANY EVENT, THE CUMULATIVE LIABILITY OF MERU OR ITS RESELLER FOR ALL CLAIMS WHATSOEVER RELATED TO THE PRODUCT OR THE SERVICE WILL NOT EXCEED THE PRICE YOU PAID FOR THE PRODUCT OR SERVICES GIVING RISE TO SUCH CLAIMS.
THE LIMITATIONS SET FORTH HEREIN ARE INTENDED TO LIMIT THE LIABILITY OF MERU AND ITS RESELLERS AND SHALL APPLY NOTWITHSTA NDING ANY FAILURE OF ESSENTIAL PURPOSE OF ANY LIMITED REMEDY.
The jurisdiction applicable to you may not allow the limitations of liability or damages set forth above, in which case such limitation shall only apply to you to the extent permitted in such jurisdiction.
Additional Information
This Limited Product Warranty shall be governed by and construed in accordance with the laws of the State of California, U.S.A., excl usive of it s conflict of laws princip les. The U.N. C on­vention on Contracts for the International Sale of Goods shall not apply.
This Limited Product Warranty is the entire and exclusive agreement between you and Meru with respect to its subject matter, and any modification or waiver of any provision of this state­ment is not effective unless expressly set forth in writing by an authorized representative of Meru.
All inquiries or claims made under this Limited Product Warranty must be sent to Meru at the following address:
Meru Networks Inc., 894 Ross Drive, CA 94087, USA Tel: 408-215-5300 Fax: 408-215-5301 Email: support@merunetworks.com
6

Table of Contents

About AP122. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Safety Precautions—IMPORTANT. . . . . . . . . . . . . . . . . . . . . . . . 1
Power Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Power Output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Enclosure and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Mounting AP122 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Additional Notes..................................................................11
Maximum EIRP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Dual Concurrent Same Band Operation . . . . . . . . . . . . . . . . . . . 11
Manufacturing Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Distributed Antenna Systems (DAS). . . . . . . . . . . . . . . . . . . . . . 11
Air Handling Space Requirements . . . . . . . . . . . . . . . . . . . . . . . 12
Frequencies Blocked for Regulatory Compliance. . . . . . . . . . . . 12
Underwriters Laboratories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Restriction of Hazardous Substances. . . . . . . . . . . . . . . . . . . . . 12
European Community . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
China . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Cautions and Warnings.......................................................15
Table of Contents i
Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Warnings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Regulatory Information........................................................21
Regulatory Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Declaration of Conformity, Federal Communication Commission 22
Manufacturer Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Declaration of Conformity, Industry Canada. . . . . . . . . . . . . . . . 23
Manufacturer Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Declaration of Conformity, R&TTE Directive 1999/5/EC. . . . . . . 26
Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
VCCI Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
General Information of RF Exposure . . . . . . . . . . . . . . . . . . . . . 29
International Guidelines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
FCC Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Industry Canada Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Table of Contentsii

1 About AP122

The AP122 is a dual-radio 802.11a/b/g/n/ac WLAN access point with a 2-stream design and an in-room wall plate form factor. It can operate in the 2.4 GHz band for 802.11n support and the 5 GHz band for 802.1 1ac to deliver an aggre gate data rate of 1.2 Gbp s data for de manding business applications such as video and voice.
To know more, visit Meru Networks web site.
Radio Specification
Radio 1— Dual Band 2x2 stream 11 ac
Radio 2—5Ghz 2x2 stream 11 ac

Safety Precautions—IMPORTANT

Read and follow the regulatory instructions in Appendix B before installing and operating this product.
If an optional power supply is used, it must be one supplied by Meru Networks.
This product is intended to be supplied by a UL Listed power supply marked Class 2 or LPS and rated 48V 1.04A. For Power over Ethernet, an 802.3 or 802.3at connection must be used.
The AP122 is intended only for installation in Environment A as defined in IEEE Std 802.3 All interconnected equipment must be contained within the same building, including the intercon­nected equipment's associated LAN connection.

Power Options

The AP is powered using a IEEE802.3at-2012 compliant PoE PD IN or 48V DC input.

Power Output

The IEEE802.3af-2012 compliant PoE PSE provides power output up to 13W.
Safety Precautions—IMPORTANT 1

Enclosure and Connectors

TABLE 1: AP122 Connectors - Top and Side View
Parts Descriptions
Power 48v DC input. F2 Fast-Ethernet F3 PoE PSE Out Fast Ethernet Reset Reset pin. Using a sharp pin and press in for 3 seconds to
return the AP to factory default settings
LED
LED light provides the following status indications
PINK Color - This color represents the AP in boot up
mode.
Blinking GREEN - This color represents the AP in dis-
covery mode.
Solid BLUE - This color represents the AP in connected
state.
Enclosure and Connectors2
TABLE 1: AP122 Connectors - Top and Side View
Parts Descriptions
USB USB 2.0 Port PT Out Pass Through Out.
Wired connection with Pass Through In.
TABLE 2: AP122 Connectors - Bottom View
Parts Description
G1 100 Mbps port PT In Wired connection with Pass Through Out
Enclosure and Connectors 3
Enclosure and Connectors4

2 Mounting AP122

This section provides illustrated instructions to wall mount an AP122.
Follow all recommended safety procedures before you proceed.
1. The AP122 is shipped with the wall mount bracket installed on the bottom of the AP. The
metal bracket clips into slots in the plastic housing. The captive screw used to lock the AP into place, is not engaged during shipment
.
5
The wall mount bracket is designed to be installed over a wall plate (single ga ng box).
2.
There are a series of slots in the mounting bracket to allow optional installations.
3. Remove the wall mount bracket from the AP. Lift the bracket in the indicated area to dis-
engage the clips. You will need to move the bracket up and away from the AP to clear the top "hook" clips.
4. Once the bracket has been completely removed from the AP, position the bracket over
the wall plate and install two screws (not included) as shown. Adjust th e bracket ove r the
6
wall plate box before tightening the screws. Slide the bracket up or down along the screws in the slots to the desired location. Be sure to cover any gaps in the wall.
5. Tighten screws to secure bracket to wall plate. Do not over-tighten. Over-tightening may
cause the bracket to bend.
6. Before installing the AP to the bracket, connect all necessary cabling to the ports on the
back of the AP.
7
Install the AP onto the mounting bracket by visually aligning the top "hook" cli ps to th e
7.
small raised bumps on the top edge of the AP. For additional visual alignment refe rence , use the edges of the bracket which line up with the outside vent holes on the AP.
8
9
Move the AP up slightly until you feel the top hooks slide into the receiving hole s on the
8.
back of the AP. Once the top hooks are engaged, push gently on the bottom, front of the AP to engage the bottom hooks. You should feel the clips lock into place.
9. Tighten the captive screw to secure the AP to the bracket.
10

A Additional Notes

Maximum EIRP

The transmit EIRP is the sum of the conductive transmit power, IEEE Std 802.11n multiple stream effect, and the antenna gain. By default, Meru AP122 EIRP is set lower than the regu­latory limit with the default antenna.

Dual Concurrent Same Band Operation

With grant of additional regulatory approval and Permit-but-Ask, users may configure two radios in AP122 on the same band (i.e., both radios are on the 2.4 GHz but in the different or same channels, and both radios are on the 5.x GHz but in the different or same channels).
However, user shall e xpect performance deterio ration due to RF coll ision and collocation inte r­ference. It is important that users adopt external antennas, with extended coaxial pigtail cables, with AP122 in such use case. User shall place antennas far apart to reduce interfer­ence. Meanwhile, user shall also reduce AP122 transmit power, for each radio, by at-least 3 dBm from its default setting.

Manufacturing Information

The AP122 models are built in China. Contact Meru Networks for manufacturing related infor­mation.

Distributed Antenna Systems (DAS)

Meru Networks does not certify or endorse any specific Distributed Antenna System (DAS) vendors. Meru Networks will provide support to Meru Wi-Fi customers that use distributed antennas within the terms and conditions of the MeruAssure Terms of Service and in accor­dance with the customer's support agreement. Meru Customer Support will support Meru soft­ware and hardware, and will work jointly with DAS vendors to identify and troubleshoot issues, but any support related to RF issues, including RF coverage, shall be the responsibility of the DAS vendor.
Maximum EIRP 11
Meru Networks recommends that customers u se only a DAS that has been tested to work with Meru hardware and software. Meru does not provide any site surveys, design or implementa­tion of Wi-Fi over DAS. Meru recommends that customers obtain such services from a trained and qualified systems integrator or from their DAS vendor.

Air Handling Space Requirements

AP122/AP121 are not plenum rated. The products should be installed in accordance with all applicable, local regulations and prac-
tices.

Frequencies Blocked for Regulatory Compliance

These products are for indoor use only, in U-NII-1 and/or U-NII-3 band when Dynamic Fre­quency Selection, DFS, from 5.25-5.35 GHz and 5.47-5.725 GHz, is disabled. With DFS approval, these products can operate in U-NII-2 or U-NII-2e. To ensure compliance with local regulations, be sure to set your Access Point to the country in which you are using the Access Point.

Underwriters Laboratories

Use only listed e information technology equipment (ITE) I.T.E. equipment. The unit is intended for installation in Environment A as defined in IEEE 802.3.All intercon-
nected equipments must be contained within the same building, including the interconnected equipment's associated LAN connection.

Restriction of Hazardous Substances

European Community

This device complies the Restriction of Hazardous Substances Directive (RoHS) for its restric­tion of the use of certain hazardous substances in electrical and electronic equipment for European Union.
Air Handling Space Requirements12

China

This device complies Administrative Measure on the Control of Pollution C aused by Electronic Information Products or China RoHS. AP122 may contain hazardous substances are marked with the EIP logo including an Environment Friendly Use Period (EFUP) value in 10 years.
Restriction of Hazardous Substances 13
Restriction of Hazardous Substances14

B Cautions and Warnings

The cautions and warnings that appear in this manual are listed below in English, German, French, and Spanish. Changes or modifications not expressly approved by the party responsi­ble for compliance could void the user’s authority to operate the equipment.

Cautions

A Caution calls your attention to a possible hazard that can damage equipment. "Vorsicht” weist auf die Gefahr einer möglichen Beschädigung des Gerätes in. Une mise en garde attire votre attention sur un risque possible d'endommagement de l'équi-
pement. Ci-dessous, vous trouverez les mises en garde utilisées dans ce manuel. Un mensaje de precaución le advierte sobre un posible peligro que pueda dañar el equipo.
Las siguientes son precauciones utilizadas en este manual.
When changing the orientation of the antennas, be sure to slightly loosen the knurled ring before mov­ing the antenna. Retighten the ring afterward. Otherwise, you might damage the internal cabling in the AP.
Bei einer Neuausrichtung der Antennen muss vor Bewegung der Antenne der Rändelring leicht gelock­ert werden. Anschließend den Ring wieder festziehen. Anderenfalls können die internen Kabel im AP beschädigt werden.
En cas de modification d’orientation des antennes, veiller à desserrer légèrement la bague moletée avant de réorienter l’antenne. Resserrer ensuite la bague, faute de quoi le câblage interne du point d’accès pourrait être endommagé.
Al cambiar la orientación de las antenas, asegúrese de aflojar ligeramente el anillo estriado antes de mover la antena. Luego vuelva a apretar el anillo. De otro modo, podría dañar el cableado interno del punto de acceso.
Cautions 15
The radiated output power of the access points is well below the radio frequency exposure limits. How­ever, the Meru Access Point should be used in such a manner that the potential for human contact during normal operation is minimized. To avoid the possibility of exceeding the radio frequency expo­sure limits, you should keep a distance of at least 20 cm between you (or any other person in the vicin­ity) and the Access Point antennas.
Die abgestrahlte Ausgangsleistung von Geräten von Meru Networks, Inc. liegt weit unter den Hochfre­quenz-Expositionsgrenzwerten der. Die Meru Access Point Zugangspunkte von Meru Networks, Inc. sollten jedoch so verwendet werden, dass das Potenzial für Kontakt mit Menschen während des nor­malen Betriebs auf ein Mindestmaß beschränkt wird. Um die Möglichkeit einer Überschreitung der ­Hochfrequenz-Expositionsgrenzwerte zu vermeiden, ist ein Abstand von mindestens 20 cm zwischen Ihnen (bzw. einer anderen Person in der Nähe) und den Zugangspunkt-Antennen zu wahren.
La puissance de rayonnement émise par les équipements Meru Networks, Inc. est très inférieure aux limites d'exposition aux fréquences radio définies par la. Toutefois, les points d'accès de la série Meru Access Point de Meru Networks, Inc. doivent être utilisés de façon à éliminer tout risque de contact humain en fonctionnement normal. Pour éviter de dépasser les limites d'exposition aux fréquences radio définies par la , il est impératif de préserver en permanence une distance supérieure ou égale à 20 cm entre l'utilisateur (ou toute personne se trouvant à proximité) et les antennes du point d'accès.
La potencia de radiación de los dispositivos de Meru Networks, Inc. está muy por debajo de los límites de exposición a radiofrecuencia estipulados por la. No obstante, los puntos de acceso de la serie Meru Access Point de Meru Networks, Inc. deben usarse de tal manera que se minimice la posibilidad de contacto para el usuario durante la operación normal. Para evitar la posibilidad de exceder los límites de exposición a radiofrecuencia establecidos por la, el usuario (o cualquier otra persona en torno) debe mantenerse a una distancia de al menos 20 cm respecto a las antenas del punto de acceso.
Cautions16

Warnings

Exposure to Radio Frequency Radiation. The installer of this radio equipment must ensure that the antenna is located or pointed such that it does
not emit an RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from Health Canada’s website http://www.hc-sc.gc.ca/rpb.
Exposition aux rayonnements à fréquence radioélectrique L'installateur de cet équipement radio doit veiller à positionner et orienter l'antenne de telle sorte qu'elle
n'émette pas un champ radioélectrique supérieur aux limites définies par Santé Canada pour la popula­tion générale. Consulter le Code de sécurité n° 6, disponible sur le site Web de Santé Canada à l'adresse http://www.hc-sc.gc.ca/rpb.
Exposición a la radiación de radiofrecuencia. El instalador de este equipo de radio debe cerciorarse de que la antena está localizada u orientada de
tal manera que no emita un campo de radiofrecuencia superior a los límites estipulados por Health Canada para la población; consulte el Código de Seguridad 6 que podrá encontrar en el página web de Health Canada, http://www.hc-sc.gc.ca/rpb.
A warning calls your attention to a possible hazard that can cause injury or death. The follow­ing are the warnings used in this manual.
"Achtung" weist auf eine mögliche Gefährdung hin, die zu Verletzungen oder Tod führen kön­nen. Sie finden die folgenden Warnhinweise in diesem Handbuch:
Un avertissement attire votre attention sur un risque possible de blessure ou de décès. Ci­dessous, vous trouverez les avertissements utilisés dans ce manuel.
Una advertencia le llama la atención sobre cualquier posible peligro que pueda ocasionar daños personales o la muerte. A continuación se dan las advertencias utilizadas en este manual.
antenas del punto de acceso.
Warnings 17
With plastic covers removed, this product is suitable for use in environmental air-handling space in accordance with the Section 300-22(c) of the National Electric Code and Sections 2- 128.12 - 010 (3) and 12 - 100 of the Canadian Electrical Code. Part 1. C22. 1. For other countries, consult local authori­ties for regulations.
Bei abgenommener Kunststoffabdeckung ist dieses Produkt zur Verwendung in einem Umgebung­sluftraum gemäß Abschnitt 300-22(c) des National Electric Code und Abschnitt 2- 128.12 - 010 (3) und 12 - 100 des Canadian Electrical Code Teil 1. C22.1 geeignet. Die Vorschriften für andere Länder sind bei den örtlichen Behörden erhältlich.
Sous réserve que ses couvercles de plastique soient déposés, cet appareil est adapté à une utilisation dans les vides de construction des bâtiments selon la section 300-22(c) du code NEC (National Electric Code) et les sections 2- 128.12 - 010 (3) et 12 - 100 du Code électrique du Canada, partie 1. C22. 1. Pour tous les autres pays, consulter les organismes de réglementation locaux.
Una vez desprendidas las cubiertas de plástico, este producto es adecuado para su uso en el espacio aéreo circundante en conformidad con la sección 300-22(c) del National Electric Code (Código Eléc­trico Nacional de EE.UU.) y las secciones 2- 128.12 - 010 (3) y 12 - 100 del Código Eléctrico de Canadá. Parte 1. C22. 1. En otros países, consulte a las autoridades locales competentes para infor­marse acerca de las normativas vigentes.
Any Ethernet cables installed in air-handling spaces should be suitable under NEC Article 800.50 and marked accordingly for use in plenums and air-handling spaces with regard to smoke propagation, such as CL2-P, CL3-P, MPP (Multi Purpose Plenum), or CMP (Communications Plenum).
Alle Ethernet Kabel, die in Lüftungsräumen installiert werden, sollten gemäß NEC Artikel 800.50 geeig­net sein und entsprechend zur Verwendung in Hohlräumen (Plenum) und Lüftungsräumen im Hinblick auf Rauchausbreitung gekennzeichnet sein, z.B. CL2-P, CL3-P, MPP (Multi Purpose Plenum) oder CMP (Communications Plenum).
Les câbles Ethernet installés dans un vide d’air doivent correspondre aux critères de l’article 800.50 du code NEC et identifiés en conséquence comme adaptés à une utilisation dans les vides de construction des bâtiments en matière de propagation de la fumée (marquages CL2-P, CL3-P, MPP (Multi Purpose Plenum) ou CMP (Communications Plenum)).
Todos los cables Ethernet instalados en espacios aéreos deben cumplir con el artículo 800.50 del NEC y estar marcados adecuadamente para su uso en espacios aéreos y plenums en lo concerniente a la propagación de humo, tales como CL2-P, CL3-P, MPP (Plenum multifuncional), o CMP (Plenum de comunicaciones).
Warnings18
Indoor antennas must be positioned to observe minimum separation of 20 cm. (~ 8 in.) from all users and bystanders. For the protection of personnel working in the vicinity of inside (downlink) antennas, the following guidelines for minimum distances between the human body and the antenna must be observed.
The installation of the indoor antenna must be such that, under normal conditions, all personnel cannot come within 20 cm. (~ 8.0 in.) from any inside antenna. Exceeding this minimum separation will ensure that the employee or bystander does not receive RF-exposure beyond the Maximum Permissible Expo­sure according to local country regulatory approval.
Indoorantennen müssen so positioniert werden, dass ein Mindestabstand von 20 cm (ca. 8 Zoll) zu allen Benutzern und anderen Personen gewahrt wird. Zum Schutz von Personal, das in der Nähe von Innenantennen (Downlink) arbeitet, sind die folgenden Richtlinien für Mindestabstand zwischen dem menschlichen Körper und der Antenne zu beachten.
Die Innenantenne muss so installiert werden, dass sich unter normalen Bedingungen kein Personal bis auf weniger als 20 cm (ca. 8 Zoll) an eine Innenantenne annähern kann. Durch Überschreitung dieses Mindestabstands wird sichergestellt, dass Mitarbeiter oder andere Personen keiner RF-Exposition über die maximal zulässige Exposition (MPE; Maximum Permissible Exposure) gemäß FCC CFR 47, Abschnitt 1.1310 (Grenzwerte für die allgemeine Bevölkerung/unkontrollierte Exposition) ausgesetzt werden.
Les antennes intérieures doivent être positionnées de façon à respecter une distance minimum de 20 cm par rapport aux utilisateurs et aux tiers. Pour la protection du personnel travaillant à proximité des antennes intérieures (liaison descendante), respecter les directives suivantes pour assurer des dis­tances minimales entre les êtres humains et les antennes.
Toute antenne intérieure doit être installée de telle sorte que, dans des conditions normales, le person­nel ne puisse s'en approcher à moins de 20 cm. Cette distance minimale est destinée à garantir qu'un employé ou un tiers ne sera pas exposé à un rayonnement radioélectrique supérieur à la valeur maxi­male autorisée, telle qu'elle est définie dans les limites d'exposition non contrôlées pour la population par la réglementation de la FCC CFR 47, section 1.1310.
Las antenas interiores deben colocarse de manera que se observe una separación mínima de 20 cm. (~ 8 pulg.) respecto a todos los usuarios y circunstantes. Para la protección del personal que trabaje en las inmediaciones de las antenas interiores (receptoras), deben observarse las siguientes directrices relativas a la distancia mínima entre el cuerpo humano y la antena.
La instalación de la antena interior debe efectuarse de tal modo que, en condiciones normales, ningún miembro del personal pueda acercarse a menos de 20 cm. (~ 8,0 pulg.) de cualquier antena interior. El cumplimiento de este mínimo de separación asegura que el empleado o circunstante no recibirá exposición a radiofrecuencia por encima de la Exposición Máxima Permisible conforme a la normativa FCC CFR 47, sección 1.1310, es decir, los límites asignados a la Exposición Incontrolada/Población Civil.
Warnings 19
Warnings20

C Regulatory Information

The Meru Access Point (APs) must be installed and used in strict accordance with the manu­facturer’s instructions as described in the user documentation that comes with the product. For country-specific approvals, see below. Meru Networks, Inc. is not responsible for any radio or television interference caused by unauthorized modification of APs, or the substitu­tion or attachment of connecting cables and equipment other than that specified by Meru Net­works, Inc. The correction of interference caused by such unauthorized modification, substitution or attachment is the responsibility of the user. Meru Networks, Inc. and its autho­rized resellers or distributors are not liable for any damage or violation of government regula­tions that may arise from the user failing to comply with these guidelines.
21

Regulatory Specifications

TABLE 1: Regulatory Specifications
Category Items
Safety
Unintentional Radiation Compliance
Intentional Radiation Compliance
UL 60950-1
CSA C22.2
EN 60950-1
IEC 60950-1
FCC Part 15.107 - 47CFR15.107
FCC Part 15.109 - 47CFR15.109 B
ICES-003 Class B
EN 301 489-1
EN 301 489-17
EN55022 Class B
EN55024/AS/NZS CISPR 24
VCCI Class B
FCC Part 15.247 - 47 CFR Ch. I
FCC Part 15.407 - 47 CFR15.407
RSS-210
EN 300 328
EN 301 893
Japan Radio (Ninsho)

Declaration of Conformity, Federal Communication Commission

Manufacturer Information

Meru Networks, Inc 894 Ross drive, Sunnyvale, CA 94089 USA
Regulatory Specifications22

Declaration of Conformity

This device complies with Part 15 rules. Operation is subject to the following two conditions:
This device may not cause harmful interference, and
This device must accept any interference received, including interference that may cause
undesired operation.
Device Name FCC ID Number
AP121 RE7-AP122 AP122 RE7-AP122
This product is FCC marked according to the provisions of FCC Part 15.
This equipment has been tested and found to comply with the limit s of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to pr ovide reasonab le protec­tion against harmful interference when the equipment is operated in a residential environment. This equipment generates, uses, and radiates radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference. However, there is no guarantee that interference will not occur. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from to which the receiver is con-
nected.
Consult the dealer or an experienced radio/TV technician for help.
The Part 15 radio device operates on a non-interference basis with other devices operating at this fre­quency when using the integrated antennas. Any changes or modification to the product not expressly approved by Meru could void the user's authority to operate this device.

Declaration of Conformity, Industry Canada

This equipment is in compliance with the essential requirement s of other relevant provisions of Directive.
Declaration of Conformity, Industry Canada 23

Manufacturer Information

Meru Networks, Inc 894 Ross drive, Sunnyvale, CA 94089 USA

Declaration of Conformity

The Class B digital portion of this apparatus complies with Canadian standard ICES-003. These devices comply with RSS210 of Industry Canada.
La partie numérique de Classe B de cet app areil est conforme à la norme ICES-003 cana dien. Ces appareils sont conformes à la norme RSS 210 d'Industrie Canada..
Per RSS 210 A9.5 point 7:
The device for the band 5150-5250 MHz is only for indoor usage to reduce potential for
harmful interference to co-channel mobile satellite systems (The device for the band 5150­5250 MHz is only for indoor usage to reduce potential for harmful interference to co-chan­nel mobile satellite systems)
The maximum antenna gain permitted (for devices in the bands 5250-5350 MHz and 5470-
5725 MHz) to comply with the EIRPlimit; and the maximum antenna gain permitted (for devices in the band 5725-5825 MHz) to comply with the EIRP limits specified for point-to­point and non point-to-point operation as appropriate, as stated in section A9.2(3) (The maximum antenna gain permitted (for devices in the bands 5250-5350 MHz and 5470-5725 MHz) to comply with the EIRPlimit; and the maximum antenna gain permitted (for devices in the band 5725-5825 MHz) to comply with the EIRP limits specified for point-to-point and non point-to-point operation as appropriate, as stated in section A9.2(3).
In addition, users should also be cautioned to take note that high-power radars are allo-
cated as primary users (meaning they have priority) of the bands 5250-5350 MHz and 5650-5850 MHz and these radars could cause interference and/or damage to WLAN devices (En outre, les utilisateurs doivent également être avertis de prendre note que les radars à haute puissance sont désignés comme utilisateurs principaux (ils ont la priorité) des bandes 5250-5350 MHz et 5650-5850 MHz et ces radars pourraient cause des inter­férences et / ou endommager aux appareils WLAN.
These devices are not permitted to operate in the 5600 - 5650 MHz band (Ces appareils ne
sont pas autorisés à opérer dans le 5600 - bande 5650 MHz.)
For products available in the Canadian markets, o nly chann els 1 throu gh 11 can be operated. Selection of other channels is not authorized. Operation is subject to the following two condi­tions: (1) this device may not cause interference, and (2) this device must accept any interfer­ence, including interference that may cause undesired operation of this device.
Pour les produits disponibles sur les marchés canadiens, seuls les canaux 1 à 11 peuvent être utilisés. La sélection d'autres canaux n'est p as au torisé e. Son foncti onnement e st soumis a ux
Declaration of Conformity, Industry Canada24
deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences et (2) cet appareil doit accepter toute interférence, y compris celles pouvant causer un mauvais fonctionnement de ce dispositif
This device and its listed antenna(s) must not be co-located or operated in conjunction with any other antenna or transmitter
Cet appareil et son antenne énuméré (s) ne doivent pas être situés ou exploités conjointement avec une autre antenne ou transmetteur
The term "IC" before the equipment certification number only signifies that the Industry Can­ada technical specifications were met.
Le terme "IC" avant le numéro de certification de l'équipement signifie seulement que les spécifications techniques d'Industrie Ca-nada ont été atteints
To reduce the potential radio interference to other users, the antenna type and gain should be chosen so that the equivalent isotropic radiated power (EIRP) is not more than that required for successful communication. This device complies with Class B Limits of Industry Canada. Operation is subject to the following two conditions:
Pour réduire le risque d'interférence avec d'autres utilisateurs, le type d'antenne et le gain doivent être choisis de telle sorte que la puissance isotrope rayonnée équivalente ne soit pas supérieure à celle requise pour une communication réussie. Cet appareil est conforme aux limites de Classe B d'Industrie Canada. Son fonctionnement est soumis aux deux conditions suivantes
This device may not cause harmful interference, and
Cet appareil ne doit pas provoquer d'interférences nuisibles, et
This device must accept any interference received, including interference that may cause
undesired operation.
Cet appareil doit accepter toute interférence reçue, y compris les interférences pouvant
entraîner un fonctionnement indésirable.
To prevent radio interference to the licensed service, this device is intended to be operated indoors and away from windows to provide maximum shielding. Equipment (or its transmit antenna) that is installed outdoors is subject to licensing.
Pour empecher que cet appareil cause du brouillage au service faisant l'objet d'une licence, il doit etre utilze a l'interieur et devrait etre place lin des fenetres afin de Fournier un ecram de
Declaration of Conformity, Industry Canada 25
blindage maximal. Si le matriel (ou son antenne d'emission) est installe a l'exterieur, il doit faire l'objet d'une licence.
Device Name
(Nom de l'appareil)
AP121 6749A-AP122 AP122 6749A-AP122
(Industrie Canada Numéro d'identification)
Industry Canada ID Number

Declaration of Conformity, R&TTE Directive 1999/5/EC

This equipment is in compliance with the essential requirements of other relevant provisions of Directive.

Declaration of Conformity

Hereby, Networks Inc. declares that this unit is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
To ob tain th e declaration of conformi ty (DoC) for R&TTE Directive, please access the follow­ing URL address. http://www.merunetworks.com
Notice for customers: the following information is only applicable to equipment sold in coun­tries applying EU directives. System may be operated in following countries:
EU Countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Esto­nia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Luxem­bourg, Malta, The Netherlands, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, United Kingdom.
This equipment can be operated in other non-European countries.
EFTA Countries: Norway and Switzerland EU Applicants: Albania, Bosnia and Herzegovina EU Candidate: Iceland, Macedonia and Montenegro
The following standards were applied:
EMC-EN 301.489-1 Article 3.1 (b) of R&TTE Directive; EN 301.489-17 Article 3.1 (b) of
R&TTE Directive
Health & Safety-EN60950-1
Declaration of Conformity, R&TTE Directive 1999/5/EC26
Radio-EN 300 328 Article 3.1 (b) of R&TTE Directive; EN 301.893 Article 3.1 (b) of R&TTE
Directive
Declaration of Conformity, R&TTE Directive 1999/5/EC 27
The conformity assessment procedure referred to in Article 10.4 and Annex III of Directive
1999/5/EC has been followed.
Declaration of Conformity, R&TTE Directive 1999/5/EC28
This device is intended to be used in all EU and EFTA countries.
Device Name Certification Report Number
AP121 EMCS42577A-ETS328, AP122

VCCI Statement

English Translation
EMCS42577-ETS489, EMCS42577B-ETS893
-
This is a Class B product based on the standard of the Voluntary Control Council for Interfer­ence from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. User sh all inst all and use the equipment according to the instruction manual.

General Information of RF Exposure

International Guidelines

This Device Meets International Guidelines for Exposure to Radio Waves. The AP121 and AP122 device includes radio transmitters and receivers. It is designed not to
exceed the limits for exposure to radio waves (radio frequency electromagnetic fields) recom­mended by international guidelines. The guidelines were developed by an independent scien­tific organization (ICNIRP) and include a substantial safety margin designed to ensure the safety of all persons, regardless of age and health.
VCCI Statement 29
As such the systems are designed to be operated as to avoid contact with the antennas by the end user. It is recommen ded to set the system i n a location whe re the antennas ca n remain at least a minimum distance as specified from the user in accordance to the regulatory guide­lines which are designed to reduce the overall exposure of the user or operator.
0.82 mW/cm2 25 cm (9.84 inches) 1.00 mW/cm2
The World Health Organization has stated that present scientific information does not indicate the need for any special precautions for the use of wireless devices. They recommend that if you are interested in further reducing your exposure then you can easily do so by reorienting antennas away from the user or placing he antennas at a greater separation distance then recommended.

FCC Guidelines

This device meets FCC guidelines for exposure to radio waves. The AP121 and AP122 include radio transmitters and receivers. It is designed not to exceed
the limits for exposure to radio waves (radio frequency electromagnetic fields) as referenced in FCC Part 1.1310. The guidelines are based on IEEE ANSI C 95.1 (92) and include a sub­stantial safety margin designed to ensure the safety of all persons, regardless of age and health.
Separation Distance
MPE Distance Limit
As such the systems are designed to be operated as to avoid contact with the anten nas by the end user. It is recommen ded to set the system i n a location whe re the antennas ca n remain at least a minimum distance as specified from the user in accordance to the regulatory guide­lines which are designed to reduce the overall exposure of the user or operator.
The device has been tested and found compliant wi th th e appli cable regula tions as p art o f the radio certification process.
General Information of RF Exposure30
The FCC recommends that if you are interested in further reducing your exposure then you can easily do so by reorienting antennas away from the user or placing the antennas at a greater separation distance then recommended or lowering the transmitter power output.
MPE Distance Limit
0.63 mW/cm2 20 cm (7.87 inches) 1.00 mW/cm2

Industry Canada Guidelines

This device meets Industry Canada guidelines for exposure to radio waves. The AP121 and AP122 include radio transmitters and receivers. It is designed not to exceed
the limits for exposure to radio waves (radio frequency electromagnetic fields) as referenced in Health Canada Safety Code 6. The guidelines include a substantial safety margin designed into the limit to ensure the safety of all persons, regardless of age and health.
As such the systems are designed to be operated as to avoid cont act with the antennas by the end user. It is recommen ded to set the system in a l ocation where the a ntennas ca n remain at least a minimum distance as specified from the user in accordance to the regulatory guide­lines which are designed to reduce the overall exposure of the user or operator.
Health Canada states that present scientific information does not indicate the need for any special precautions for the use of wireless devices. They recommend that if you are inter­ested in further reducing your exposure you can easily do so by reorienting antennas away from the user, placing the antennas at a greater separation distance than recommended, or lowering the transmitter power output.
Separation Distance
Separation Distance
MPE Distance Limit
0.63 mW/cm2 20 cm (7.87 inches) 1.00 mW/cm2
Health Canada states that present scientific information does not indicate the need for any special precautions for the use of wireless devices. They recommend that if you are inter­ested in further reducing your exposure you can easily do so by reorienting antennas away from the user, placing the antennas at a greater separation distance than recommended, or lowering the transmitter power output.
General Information of RF Exposure 31
General Information of RF Exposure32
Loading...