INSTALLATION AND OPERATING INSTRUCTIONS DRAFTFOR OEM USE ONLY
NOTICE
MANUAL MODE (HANDSET)
BEFORE OPERATING
1. Make sure MANUAL knob on the GV60 valve is in the ON,
full counterclockwise
position.
2. Place the ON / OFF switch (if equipped) in the I (ON) position.
TO TURN ON FIRE
When pilot ignition is conrmed, motor turns automatically to
maximum ame height.
▪ Press button (One Button Ignition)
or
AM
PM
ON
OFF
1 2
and button simultaneously
(Two Button Ignition) until two short
beeps (CE version) or continuous
beeping (CSA version) and a blinking
series of lines conrms the start sequence has begun; release button(s).
▪ Main gas ows once pilot ignition is
conrmed.
▪ The Symax automatically goes into
Manual Mode after main burner ignition.
DESIGNATED LOW FIRE AND HIGH FIRE
▪ To go to low re, double-click but-
AM
ton.
▪
is displayed.
NOTE: Flame goes to high re rst be-
fore going to low re.
▪ To go to high re, double-click but-
AM
ton.
▪
is displayed.
If the pilot does not stay lit after several tries, turn the main valve
knob to OFF and follow the instructions “TURN OFF GAS TO
APPLIANCE” (see page 10).
STANDBY MODE (PILOT FLAME)
Handset
▪
Press and hold
button
to set appliance to pilot ame.
TO TURN OFF FIRE
Handset
AM
PM
ON
OFF
1 2
▪ Press
NOTE: A new ignition is possible after
button to turn off
.
the OFF icon stops ashing.
If the appliance will not operate, follow the instructions “TURN
OFF GAS TO APPLIANCE”
(see page 10)
.
COUNTDOWN TIMER
ON / SETTING:
AM
PM
ON
OFF
1 2
1. Press and hold button until is dis-
played, and hour ashes.
2. To select hour press or button.
3. To conrm press
button. Minutes
ash.
4. To select minutes press
5. To conrm press
or button.
button or wait.
OFF:
Press
button,
and Countdown Time
disappear.
NOTE:At end of Countdown Time period, the re shuts off. The
Countdown Timer only works in Manual, Thermostatic,
and Eco Modes. Maximum Countdown Time is 9 hours
and 50 minutes.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFTFOR OEM USE ONLY
SELECTED
ON TIME SETTING (PROGRAM 1):
7.
AM
PM
ON
OFF
1 2
, , is displayed, is dis-
played shortly, and hour ashes.
8. To select hour press
9. To conrm press
is displayed,
or button.
button. , ,
displayed shortly,
and minutes ash.
10. To select minutes press
or but-
ton.
11. To conrm press
button.
OFF TIME SETTING (PROGRAM 1):
AM
PM
ON
OFF
1 2
12. , , is displayed, is dis-
played shortly, and hour ashes.
13. To select hour, press
14. To conrm press
or button.
button. , ,
is displayed, is displayed
shortly, and minutes ash.
15. To select minutes press
or but-
ton.
16. To conrm press
button.
2ND BURNER FEATURE
The latching solenoid valve will open automatically after ignition or after switching the system OFF, so that the maximum
ow of gas is supplied to both burners assisting with the ignition
process. After pressing the button for the 2nd Bruner the motor
will turn 7 seconds in the ON direction until the max. position is
reached.
ON:
▪
AM
PM
ON
OFF
1 2
To switch a burner ON, press the
button.
▪
displayed.
OFF:
▪ To switch the burner OFF, press the
button.
▪ disappears.
NOTE: The latching solenoid valve cannot operate manually. If
the receiver battery runs down it will remain in the last
operating position.
NOTE: Either continue to PROGRAM 2 and set on and off times
or stop programming at this point, and PROGRAM 2 remains deactivated.
NOTE: PROGRAM 1 and 2 use the same on (Thermostatic) and
off temperatures for
, and Daily Timer ( , , ,
, , , ). Once a new ON (Thermostatic) and / or OFF
temperature has been set, that temperature becomes the
new default setting.
NOTE: If
, or Daily Timer are programmed for PRO-
GRAM 1 and PROGRAM 2 ON and OFF times, these
become the new default times. The batteries must be removed to clear the PROGRAM 1 and PROGRAM 2 ON
and OFF times and temperatures.
or Daily Timer ( , , , , , , ) selected
▪ Set ON time and OFF time using same procedure as “
se-
lected” (above).
▪
:
Set ON time and OFF time for both Saturday and Sunday.
▪ Daily Timer: Unique ON and OFF times may be set for a single
day of the week, for multiple days of the week, or for every day
of the week.
▪ Wait to nish setting.
ECO MODE
ON:
AM
▪ Press
▪
is displayed.
OFF:
1. Press
2. Press
Mode.
3. Press button to enter Thermostatic
Mode.
4. Press button to enter Program
Mode.
CIRCULATING FAN OPERATION
Circulating fan has 4 speed levels from
AM
low (1 bar) to high (4 bars).
ON / SETTING:
1. Press
ashes.
2. Press
and
3. To conrm setting either press
ton or wait (
button to enter Eco Mode.
button.
or button to enter Manual
button and hold until
button to increase fan speed
button to decrease fan speed.
but-
displayed).
20 / 30
OFF:
Press
button until all 4 speed level
bars disappear.
NOTE: SETTING only. If the fan was not switched OFF after
last use, it starts automatically 4 minutes after ignition
at maximum speed and goes to the last set level after
10 seconds. The fan stops 10 minutes after the gas is
OFF or at pilot.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFTFOR OEM USE ONLY
NOTICE
LIGHT / DIMMER OPERATION
ON:
AM
▪ Press
▪ Light is ON at preset level.
button ( is displayed).
OFF:
Press
button ( disappears).
SETTING:
1. Press
button and hold until ash-
es.
2. To adjust light between 20…100 %
press
3. To conrm setting either press
ton or wait (
or button.
but-
is displayed).
NOTE: The Light works independently of the pilot ame. If you
want the light on but no ame, press
button.
MYFIRE APP
Before the App can be used, the myre Wi-Fi Box must be wired
and plugged into mains power according to myre App setup
diagram (see gure 32, page 30), and the App setup must be
completed (see myre App setup, page 25).
If Thermostatic, Program or Eco Mode
AM
PM
ON
OFF
1 2
is activated in the App, the correspond-
ing icon and “
” is displayed on the
handset.
The modes can be operated according
to the descriptions on previous pages.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFTFOR OEM USE ONLY
NOTICE
NOTICE
NOTICE
THE PUCK HANDSET
TECHNICAL DATA
AMBIENT TEMPERATURE RANGE
CSA: The Puck: 32 °F to 131 °F
CE: The Puck: 0 °C to 55 °C
RADIO FREQUENCY
CSA: 918.0 MHz for U.S. (FCC), Canada (ISED), New Zea-
land (RNZ) and Australia (ACMA) (The Puck, receiver)
CE: 868.1 MHz for Europe (The Puck, receiver)
(see radio frequency information on page 4.)
RADIATED POWER OUTPUT
CSA: 84.5 µV/m
CE: -18.5 dBm
POWER SUPPLY
Handset: 2 x 1.5 V “AAA” (quality alkaline recommended)
Wiring of valve and receiver must be completed before starting
ignition. Failure to do so could damage the electronics.
The handsets and receivers are not interchangeable with previous electronics G6R and B6R-R8(9)U(T).
SYNCHRONIZATION RECEIVER/ THE PUCK HANDSET
See page 7 for more information about synchronization between
receiver and The Puck.
MODES OF OPERATION
When pilot ignition is conrmed, motor turns automatically to
maximum ame height.
TURN FIRE ON AND OFF▪ Press and hold the
button until two
short beeps conrms the start sequence has begun; release button.
▪ Main gas ows once pilot ignition is
conrmed.
▪ Press and hold the
OFF
.
button to turn
If the pilot does not stay lit after several tries, turn the main valve
knob to OFF and follow the instructions “TURN OFF GAS TO
APPLIANCE” (see page 10).
To avoid damaging the electronics, do NOT use metal tools to
remove the batteries from the handset / receiver.
▪ Without using a mains adapter, battery replacement is recom-
mended at the beginning of each heating season.
▪ Old or dead batteries should be removed immediately. If left
in the unit the batteries can overheat, leak, and / or explode.
▪ Do NOT expose batteries (including during storage) to direct
sunlight, excessive heat, re, moisture, or severe impact. Each
of these conditions can cause the batteries to overheat, leak,
and / or explode.
▪ Batteries must be kept within their recommended temperature
limits (ambient battery temperature range: 32 °F to 131 °F /
0 °C to 55 °C).
▪ New and old batteries and different brands of batteries should
not be used together. Mixing of various batteries can cause
the batteries to overheat, leak, and / or explode.
ON / OFF
Up / HIDown /LO
STANDBY MODE (PILOT FLAME)
▪ Press and hold the "–" button to set
appliance to pilot ame
FLAME HEIGHT ADJUSTMENT
▪ To increase ame height press and
hold "+" button.
▪ To decrease ame height or to set ap-
pliance to pilot ame, press and hold
"–" button.
DESIGNATED LOW FIRE AND HIGH FIRE
▪ To go to hi re, double-click "+" button.
▪
To go to low re, double-click "–" button.
NOTE: Flame goes to high re rst be-
fore going to low re.
Figure 23: 3-button layout
22 / 30
If the appliance will not operate, follow the instructions “TURN