Mertik Maxitrol and KG B6RHAT, B6RRAP User Manual

INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY
10- BUTTON OPER ATION
Countdown Timer
Program Mode
1 2
Figure 22: 10-button Display
SETTING FAHRENHEIT OR CELSIUS
To change between °C and °F, press
AM
ON OFF
1 2
and buttons simultaneously.
NOTE: Choosing °F results in a 12 hour
clock. Choosing °C results in a 24 hour clock.
ON OFF
Time
Temperature
Signal Indicator Child Proof
AM PM
CHILD PROOF
ON OFF
1 2
Thermostatic Mode
2nd Burner Feature
AM PM
Battery Status
Fan
Fahrenheit or Celsius
Light
Eco Mode
ON:
To activate press
and buttons
simultaneously.
is displayed and the Symax is
rendered inoperable, except for the OFF function.
ENGLISH
SETTING THE TIME
1. Press and buttons simultane-
AM PM
ON OFF
1 2
ously. Day ashes.
2. Press
or button to select a num­ber to correspond with the day of the week (e. g.
  = Monday, = Tuesday,
= Wed nesday,   = Thursday, = F ri -
day,
  = Sat urday, = Sunday).
3. Press
and buttons simultane-
ously. Hour ashes.
4. To select hour press
5. Press
and buttons simultane-
ously. Minutes ash.
6. To select minutes press ton.
7. To conrm press
and buttons
simultaneously or wait.
or button.
or but-
OFF: To deactivate press
simultaneously.
disappears.
and buttons
© 2019 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
17 / 30
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY
NOTICE
MANUAL MODE (HANDSET)
BEFORE OPERATING
1. Make sure MANUAL knob on the GV60 valve is in the ON,
full counterclockwise
position.
2. Place the ON / OFF switch (if equipped) in the I (ON) position.
TO TURN ON FIRE
When pilot ignition is conrmed, motor turns automatically to maximum ame height.
Press button (One Button Ignition)
or
AM PM
ON OFF
1 2
and button simultaneously
(Two Button Ignition) until two short beeps (CE version) or continuous beeping (CSA version) and a blinking series of lines conrms the start se­quence has begun; release button(s).
▪ Main gas ows once pilot ignition is
conrmed.
The Symax automatically goes into
Manual Mode after main burner igni­tion.
DESIGNATED LOW FIRE AND HIGH FIRE
▪ To go to low re, double-click but-
AM
ton.
is displayed.
NOTE: Flame goes to high re rst be-
fore going to low re.
▪ To go to high re, double-click but-
AM
ton.
is displayed.
If the pilot does not stay lit after several tries, turn the main valve knob to OFF and follow the instructions “TURN OFF GAS TO APPLIANCE” (see page 10).
STANDBY MODE (PILOT FLAME)
Handset
Press and hold
button
to set appliance to pilot ame.
TO TURN OFF FIRE
Handset
AM PM
ON OFF
1 2
▪ Press
NOTE: A new ignition is possible after
button to turn off
.
the OFF icon stops ashing.
If the appliance will not operate, follow the instructions “TURN OFF GAS TO APPLIANCE
(see page 10)
.
COUNTDOWN TIMER
ON / SETTING:
AM PM
ON OFF
1 2
1. Press and hold button until is dis-
played, and hour ashes.
2. To select hour press or button.
3. To conrm press
button. Minutes
ash.
4. To select minutes press
5. To conrm press
or button.
button or wait.
OFF: Press
button,
and Countdown Time
disappear.
NOTE: At end of Countdown Time period, the re shuts off. The
Countdown Timer only works in Manual, Thermostatic, and Eco Modes. Maximum Countdown Time is 9 hours and 50 minutes.
FLAME HEIGHT ADJUSTMENT
AM PM
ON OFF
1 2
18 / 30
Handset
▪ To increase ame height press and
hold
button.
▪ To decrease ame height or to set ap-
pliance to pilot ame, press and hold
button.
© 2019 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY
MODES OF OPERATION
Thermostatic Mode
AM PM
ON OFF
1 2
AM PM
ON OFF
1 2
The room temperature is measured and compared to the set temperature. The ame height is then automatically ad­justed to achieve the set temperature.
PROGRAM 1 and 2, each can be pro­grammed to go ON and OFF at specic times at a set temperature.
  Program Mode
PROGRAM MODE
AM PM
ON OFF
1 2
AM PM
ON OFF
1 2
ON:
Press
button.
, or , or is displayed.
OFF:
1. Press
2. Press
button. or button to enter Manual
Mode.
3. Press button to enter Thermostatic Mode.
4. Press button to enter Eco Mode.
ENGLISH
AM
THERMOSTATIC MODE
AM PM
ON OFF
1 2
AM PM
ON OFF
1 2
Eco Mode
Flame height modulates between high and low. If the room temperature is low-
er than the set temperature, the ame
height stays on high for a longer period of time. If the room temperature is high-
er than the set temperature, the ame
height stays on low for a longer period of time. One cycle lasts approx. 20 min.
ON:
Press
is displayed, preset temperature is
button.
displayed briey, and then room tem­perature is displayed.
OFF:
1. Press
2. Press
button.
or button to enter Manual
Mode.
3. Press button to enter Program Mode.
4. Press button to enter Eco Mode.
SETTING:
1. Press
button and hold until is dis-
played, temperature ashes.
2. To adjust set temperature press
or
button.
3. To conrm press
button or wait.
NOTE: The set temperature for Thermostatic Mode is the tem-
perature for the ON time in Program Mode. Changing the Thermostatic Mode set temperature also changes the ON time temperature in Program Mode.
Default settings: ON TIME (Thermostatic) TEMPERATURE: 70 °F / 21 °C OFF TIME TEMPERATURE: “
” (pilot ame only)
TEMPERATURE SETTING:
AM PM
ON
OFF
1 2
1. Press
ashes. (setting in Thermostatic Mode) is dis-
played.
2. To continue press
button and hold until
and set temperature
button or wait.
 , is displayed, temperature
ashes.
3. Select OFF temperature by pressing the
or button.
4. To conrm press
button.
NOTE: The ON (Thermostatic) and OFF set temperatures are
the same for each day.
DAY SETTING:
5.
AM PM
ON OFF
1 2
ashes. Press or button to
choose between
, ,  , , ,  ,
 ,  , .
6. To conrm press
button.
© 2019 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
19 / 30
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY
SELECTED
ON TIME SETTING (PROGRAM 1):
7.
AM PM
ON
OFF
1 2
, , is displayed, is dis-
played shortly, and hour ashes.
8. To select hour press
9. To conrm press
is displayed,
or button.
button. , ,
displayed shortly,
and minutes ash.
10. To select minutes press
or but-
ton.
11. To conrm press
button.
OFF TIME SETTING (PROGRAM 1):
AM PM
ON
OFF
1 2
12. , , is displayed, is dis-
played shortly, and hour ashes.
13. To select hour, press
14. To conrm press
or button.
button. , ,
is displayed, is displayed
shortly, and minutes ash.
15. To select minutes press
or but-
ton.
16. To conrm press
button.
2ND BURNER FEATURE
The latching solenoid valve will open automatically after igni­tion or after switching the system OFF, so that the maximum
ow of gas is supplied to both burners assisting with the ignition
process. After pressing the button for the 2nd Bruner the motor will turn 7 seconds in the ON direction until the max. position is reached.
ON:
AM PM
ON OFF
1 2
To switch a burner ON, press the button.
displayed.
OFF: To switch the burner OFF, press the
button.
▪ disappears.
NOTE: The latching solenoid valve cannot operate manually. If
the receiver battery runs down it will remain in the last operating position.
NOTE: Either continue to PROGRAM 2 and set on and off times
or stop programming at this point, and PROGRAM 2 re­mains deactivated.
NOTE: PROGRAM 1 and 2 use the same on (Thermostatic) and
off temperatures for
, and Daily Timer (  , , ,
 ,  ,  , ). Once a new ON (Thermostatic) and / or OFF
temperature has been set, that temperature becomes the new default setting.
NOTE: If
, or Daily Timer are programmed for PRO-
GRAM 1 and PROGRAM 2 ON and OFF times, these become the new default times. The batteries must be re­moved to clear the PROGRAM 1 and PROGRAM 2 ON and OFF times and temperatures.
or Daily Timer (  , , ,  ,  ,  , ) selected
▪ Set ON time and OFF time using same procedure as “
se-
lected” (above).
:
Set ON time and OFF time for both Saturday and Sunday.
▪ Daily Timer: Unique ON and OFF times may be set for a single
day of the week, for multiple days of the week, or for every day of the week.
▪ Wait to nish setting.
ECO MODE
ON:
AM
Press
is displayed.
OFF:
1. Press
2. Press Mode.
3. Press button to enter Thermostatic Mode.
4. Press button to enter Program Mode.
CIRCULATING FAN OPERATION
Circulating fan has 4 speed levels from
AM
low (1 bar) to high (4 bars).
ON / SETTING:
1. Press
ashes.
2. Press and
3. To conrm setting either press ton or wait (
button to enter Eco Mode.
button.
or button to enter Manual
button and hold until
button to increase fan speed
button to decrease fan speed.
but-
displayed).
20 / 30
OFF:
Press
button until all 4 speed level
bars disappear.
NOTE: SETTING only. If the fan was not switched OFF after
last use, it starts automatically 4 minutes after ignition at maximum speed and goes to the last set level after 10 seconds. The fan stops 10 minutes after the gas is OFF or at pilot.
© 2019 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY
NOTICE
LIGHT / DIMMER OPERATION
ON:
AM
Press Light is ON at preset level.
button ( is displayed).
OFF: Press
button ( disappears).
SETTING:
1. Press
button and hold until ash-
es.
2. To adjust light between 20…100 % press
3. To conrm setting either press ton or wait (
or button.
but-
is displayed).
NOTE: The Light works independently of the pilot ame. If you
want the light on but no ame, press
button.
MYFIRE APP
Before the App can be used, the myre Wi-Fi Box must be wired and plugged into mains power according to myre App setup diagram (see gure 32, page 30), and the App setup must be completed (see myre App setup, page 25).
If Thermostatic, Program or Eco Mode
AM PM
ON OFF
1 2
is activated in the App, the correspond-
ing icon and “
” is displayed on the
handset.
The modes can be operated according to the descriptions on previous pages.
NOTE: In Manual Mode “
” is NOT
displayed on the handset.
ENGLISH
© 2019 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
21 / 30
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY
NOTICE
NOTICE
NOTICE
THE PUCK HANDSET
TECHNICAL DATA
AMBIENT TEMPERATURE RANGE CSA: The Puck: 32 °F to 131 °F CE: The Puck: 0 °C to 55 °C
RADIO FREQUENCY CSA: 918.0 MHz for U.S. (FCC), Canada (ISED), New Zea-
land (RNZ) and Australia (ACMA) (The Puck, receiver)
CE: 868.1 MHz for Europe (The Puck, receiver) (see radio frequency information on page 4.)
RADIATED POWER OUTPUT CSA: 84.5 µV/m CE: -18.5 dBm
POWER SUPPLY Handset: 2 x 1.5 V “AAA” (quality alkaline recommended)
Wiring of valve and receiver must be completed before starting ignition. Failure to do so could damage the electronics.
The handsets and receivers are not interchangeable with previ­ous electronics G6R and B6R-R8(9)U(T).
SYNCHRONIZATION RECEIVER / THE PUCK HANDSET
See page 7 for more information about synchronization between receiver and The Puck.
MODES OF OPERATION
When pilot ignition is conrmed, motor turns automatically to maximum ame height.
TURN FIRE ON AND OFF Press and hold the
button until two
short beeps conrms the start se­quence has begun; release button.
▪ Main gas ows once pilot ignition is
conrmed.
▪ Press and hold the
OFF
.
button to turn
If the pilot does not stay lit after several tries, turn the main valve knob to OFF and follow the instructions “TURN OFF GAS TO APPLIANCE” (see page 10).
To avoid damaging the electronics, do NOT use metal tools to remove the batteries from the handset / receiver.
▪ Without using a mains adapter, battery replacement is recom-
mended at the beginning of each heating season.
▪ Old or dead batteries should be removed immediately. If left
in the unit the batteries can overheat, leak, and / or explode.
▪ Do NOT expose batteries (including during storage) to direct
sunlight, excessive heat, re, moisture, or severe impact. Each
of these conditions can cause the batteries to overheat, leak, and / or explode.
▪ Batteries must be kept within their recommended temperature
limits (ambient battery temperature range: 32 °F to 131 °F / 0 °C to 55 °C).
▪ New and old batteries and different brands of batteries should
not be used together. Mixing of various batteries can cause the batteries to overheat, leak, and / or explode.
ON / OFF
Up / HIDown /LO
STANDBY MODE (PILOT FLAME) ▪ Press and hold the "–" button to set
appliance to pilot ame
FLAME HEIGHT ADJUSTMENT
▪ To increase ame height press and
hold "+" button.
▪ To decrease ame height or to set ap-
pliance to pilot ame, press and hold
"–" button.
DESIGNATED LOW FIRE AND HIGH FIRE
▪ To go to hi re, double-click "+" button.
To go to low re, double-click "–" button.
NOTE: Flame goes to high re rst be-
fore going to low re.
Figure 23: 3-button layout
22 / 30
If the appliance will not operate, follow the instructions “TURN OFF GAS TO APPLIANCE
(see page 10)
.
© 2019 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
Loading...
+ 12 hidden pages