OPERATING INSTRUCTIONS FOR OEM USE ONLY
6- SYMBOL
Countdown Timer
Program Mode
Figure 21: 6-symbol Display
SETTING CELSIUS OR FAHRENHEIT
To change between °C and °F, press
AM
PM
ON
OFF
1 2
and buttons simultaneously.
NOTE: Choosing °F results in a 12 hour
clock. Choosing °C results in a
24 hour clock.
1 2
ON
OFF
Time
Temperature
Signal Indicator Child Proof
Thermostatic Mode
AM
PM
MODES OF OPERATION
Enter Mode
AM
PM
ON
OFF
1 2
Press the appropriate mode button.
Exit Mode
1. Press the same mode button again to
2. Press
3. Press a different mode button to
Battery Status
°F or °C
change to Manual mode.
or button to change to
Manual mode.
change to that mode.
SETTING THE TIME
AM
PM
ON
OFF
1 2
16 / 28
1. Press and buttons simultane-
ously. Hour fl ashes.
2. To select hour press
3. Press
and buttons simultane-
or button.
ously. Minutes fl ash.
4. To select minutes press
or but-
ton.
5. To confi rm press
and buttons
simultaneously or wait.
Thermostatic Mode
AM
PM
ON
OFF
1 2
The room temperature is measured and
compared to the set temperature. The
fl ame height is then automatically ad-
justed to achieve the set temperature.
Program Mode
AM
PM
ON
OFF
1 2
Programs 1 and 2, each can be pro-
grammed to go ON and OFF at specifi c
times at a set temperature.
© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
OPERATING INSTRUCTIONS FOR OEM USE ONLY
MANUAL MODE (HANDSET)
NOTICE
BEFORE OPERATING
1. Make sure MANUAL knob on the GV60 Valve is in the ON,
full counterclockwise
position.
2. Place the ON/OFF switch (if equipped) in the “ I” ( ON position).
TO TURN ON FIRE
When pilot ignition is confi rmed, motor turns automatically to
maximum fl ame height.
Handset
AM
PM
ON
OFF
1 2
▪ Press
fi rms the start sequence has begun;
release button.
▪ Continuing beeps confi rm ignition is in
button until a short beep con-
process.
▪ Rotating circle is shown on display un-
til ignition sequence is complete.
▪ There is main gas fl ow once pilot igni-
tion is confi rmed.
▪ Handset automatically goes into Man-
ual mode after main burner ignition.
If the pilot does not stay lit after several tries, turn the main valve
knob to OFF and follow the instructions “TURN OFF GAS TO
APPLIANCE ” (page 28).
DESIGNATED LOW FIRE AND HIGH FIRE
▪ To go to low fi re, double-click but-
AM
ton. “LO” is displayed.
NOTE: Flame goes to high fi re fi rst be-
fore going to low fi re.
AM
▪ To go to high fi re, double-click but-
ton. “HI” is displayed.
If the appliance will not operate, follow the instructions “TURN
OFF GAS TO APPLIANCE”
(page 28)
.
THERMOSTATIC MODE
6-SYMBOL
Standby Mode (Pilot Flame)
Handset
▪
Press and hold
button
to set appliance to pilot fl ame.
TO TURN OFF FIRE
Handset
AM
PM
ON
OFF
1 2
▪ Press
NOTE: There is a 5 sec delay before
FLAME HEIGHT ADJUSTMENT
Handset
AM
PM
ON
OFF
1 2
▪ To increase fl ame height press and
hold
▪ To decrease fl ame height or to set ap-
pliance to pilot fl ame, press and hold
button.
button to turn off
.
the next ignition is possible.
button.
ON:
AM
PM
ON
OFF
1 2
Press
played, preset temperature displayed
briefl y, and then room temperature dis-
played.
button. Thermostat icon dis-
OFF:
1. Press
2. Press
button.
or button to enter Manual
mode.
3. Press
button to enter Countdown
Timer mode.
AM
PM
ON
OFF
1 2
SETTING:
1. Press
button and hold until Ther-
mostat icon displayed, temperature
fl ashes.
2. To adjust SET temperature press
or
button.
3. To confi rm press
button or wait.
© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
17 / 28
OPERATING INSTRUCTIONS FOR OEM USE ONLY
COUNTDOWN TIMER
ON/SETTING:
AM
PM
ON
OFF
1 2
1. Press and hold
glass icon displayed and hour fl ashes.
2. To select hour press
3. To confi rm press
button until hour-
or button.
button. Minutes
fl ash.
4. To select minutes press
5. To confi rm press
or button.
button or wait.
OFF:
Press
button, hourglass and count-
down time disappear.
NOTE: At end of countdown time period, the fi re turns OFF. The
CountdownTimer only works in Manual, Thermostatic, and
Random modes. Maximum countdown time is 9 hours.
PROGRAM MODE
NOTE: The set temperature for Thermostatic Mode is the tem-
perature for the ON time in Program Mode. Changing
the Thermostatic Mode set temperature also changes
the ON time temperature in Program Mode.
Time SETTING:
AM
PM
ON
OFF
1 2
1. Press
2. To select hour press
3. To confi rm press
button and hold until , ,
displayed, hour fl ashes.
or button.
button. , dis-
played, minutes fl ash.
4. To select minutes press
or but-
ton.
AM
PM
ON
OFF
1 2
5. To confi rm press button. , ,
displayed, hour fl ashes.
6. To select hour, press
7. To confi rm press
or button.
button. , ,
displayed, minutes fl ash.
8. To select minutes press
or but-
ton.
NOTE: If you stop programming at this point, program 2 remains
deactivated.
ON:
AM
PM
ON
OFF
1 2
Press
displayed.
button. , or , ON or OFF
OFF:
AM
PM
ON
OFF
1 2
1. Press
Manual mode.
2. Press
mode.
or or button to enter
button to enter Thermostatic
3. Press Random icon button to enter
Random mode.
PROGRAM Temperature SETTING:
AM
PM
O N
O FF
1 2
1. Press
displayed.
2. To continue press
button and hold until ,
, Set temperature (Thermostatic)
button. ,
displayed, temperature fl ashes and
wait.
3. To select OFF temperature press
or
button.
4. To confi rm press
button or wait.
NOTE: The ON (Thermostatic) and OFF set temperatures are
the same for each day.
NOTE: Programs 1 and 2 use the same ON (Thermostatic) and
OFF temperatures.
1.
To continue to program , press
AM
PM
ON
OFF
1 2
button.
fl ashes.
2. To select hour press
3. To confi rm press
, ,
displayed, hour
button. , ,
displayed, minutes fl ash.
4. To select minutes, press
ton.
5. To confi rm press
button. , ,
displayed, hour fl ashes.
6. To select hour, press
7. To confi rm press
button. , ,
displayed, minutes fl ash.
8. To select minutes, press
ton.
9. To confi rm press
NOTE: Programs
and use the same ON and OFF tempera-
button or wait.
tures. Once an ON and/or OFF temperature has been
set, that temperature becomes the new default setting.
CHILD PROOF
ON:
AM
PM
ON
OFF
1 2
To activate press
multaneously. Children icon displayed
and the handset is rendered inoperable, except for the OFF function.
and buttons si-
OFF:
To deactivate press
and buttons
simultaneously. Children icon disappears.
or button.
or but-
or button.
or but-
18 / 28
© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
OPERATING INSTRUCTIONS FOR OEM USE ONLY
8-SYMBOL
Countdown Timer
Program Mode
1 2
Figure 22: 8-symbol Display
SETTING CELSIUS OR FAHRENHEIT
To change between °C and °F, press
AM
PM
ON
OFF
1 2
and buttons simultaneously.
NOTE: Choosing °F results in a 12 hour
clock. Choosing °C results in a
24 hour clock.
ON
OFF
Time
Temperature
Signal Indicator Child Proof
Thermostatic Mode
AM
PM
Auxiliary Feature
MODES OF OPERATION
AM
PM
ON
OFF
1 2
Battery Status
°F or °C
Random Mode
Enter Mode
Press the appropriate mode button.
Exit Mode
1. Press the same mode button again to
change to Manual mode.
2. Press
or button to change to
Manual mode.
3. Press a different mode button to
change to that mode.
8-SYMBOL
SETTING THE TIME
AM
PM
ON
OFF
1 2
© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
1. Press and buttons simultane-
ously. Hour fl ashes.
2. To select hour press
3. Press
and buttons simultane-
or button.
ously. Minutes fl ash.
4. To select minutes press
or but-
ton.
5. To confi rm press
and buttons
simultaneously or wait.
AM
PM
ON
OFF
1 2
Thermostatic Mode
The room temperature is measured and
compared to the set temperature. The
fl ame height is then automatically ad-
justed to achieve the set temperature.
AM
PM
ON
OFF
1 2
Program Mode
Programs 1 and 2, each can be pro-
grammed to go ON and OFF at specifi c
times at a set temperature.
19 / 28
OPERATING INSTRUCTIONS FOR OEM USE ONLY
Random Mode
AM
Flame height changes automatically.
NOTE: Mains adapter recommended.
MANUAL MODE (HANDSET)
NOTICE
BEFORE OPERATING
1. Make sure MANUAL knob on the GV60 Valve is in the ON,
full counterclockwise
position.
2. Place the ON/OFF switch (if equipped) in the “ I” (ON position).
TO TURN ON FIRE
FLAME HEIGHT ADJUSTMENT
Handset
AM
PM
ON
OFF
1 2
▪ To increase fl ame height press and
hold
button.
▪ To decrease fl ame height or to set ap-
pliance to pilot fl ame, press and hold
button.
DESIGNATED LOW FIRE AND HIGH FIRE
▪ To go to low fi re, double-click but-
AM
ton. “LO” is displayed.
NOTE: Flame goes to high fi re fi rst be-
fore going to low fi re.
When pilot ignition is confi rmed, motor turns automatically to
maximum fl ame height.
Handset
AM
PM
ON
OFF
1 2
▪ Press
fi rms the start sequence has begun;
release button.
▪ Continuing beeps confi rm ignition is in
button until a short beep con-
process.
▪ Rotating circle is shown on display un-
til ignition sequence is complete.
▪ There is main gas fl ow once pilot igni-
tion is confi rmed.
▪ Handset automatically goes into Man-
ual mode after main burner ignition.
If the pilot does not stay lit after several tries, turn the main valve
knob to OFF and follow the instructions “TURN OFF GAS TO
APPLIANCE ” (page 28).
Standby Mode (Pilot Flame)
Handset
▪
Press and hold
button
to set appliance to pilot fl ame.
▪ To go to high fi re, double-click but-
AM
ton. “HI” is displayed.
If the appliance will not operate, follow the instructions “TURN
OFF GAS TO APPLIANCE”
(page 28)
.
TO TURN OFF FIRE
AM
PM
ON
OFF
1 2
20 / 28
Handset
▪ Press
button to turn off
.
NOTE: There is a 5 sec delay before
the next ignition is possible.
© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
OPERATING INSTRUCTIONS FOR OEM USE ONLY
THERMOSTATIC MODE
AM
PM
ON
OFF
1 2
4. Press
button to enter Random mode.
AM
PM
ON
OFF
1 2
ON:
Press
button. Thermostat icon dis-
played, preset temperature displayed
briefl y, and then room temperature dis-
played.
OFF:
1. Press
2. Press
button.
or button to enter Manual
mode.
3. Press
button to enter Countdown
Timer mode.
SETTING:
1. Press
button and hold until Ther-
mostat icon displayed, temperature
fl ashes.
2. To adjust SET temperature press
or
button.
3. To confi rm press
button or wait.
OFF:
AM
PM
ON
OFF
1 2
1. Press
Manual mode.
2. Press
mode.
or or button to enter
button to enter Thermostatic
3. Press Random icon button to enter
Random mode.
PROGRAM Temperature SETTING:
AM
PM
O N
O FF
1 2
1. Press
displayed.
2. To continue press
button and hold until ,
, Set temperature (Thermostatic)
button. ,
displayed, temperature fl ashes and
wait.
3. To select OFF temperature press
or
button.
4. To confi rm press
button or wait.
NOTE: The ON (Thermostatic) and OFF set temperatures are
the same for each day.
COUNTDOWN TIMER
ON/SETTING:
AM
PM
ON
OFF
1 2
1. Press and hold
glass icon displayed and hour fl ashes.
2. To select hour press
3. To confi rm press
button until hour-
or button.
button. Minutes
fl ash.
4. To select minutes press
or but-
ton.
5. To confi rm press
button or wait.
OFF:
Press
button, hourglass and count-
down time disappear.
NOTE: At end of countdown time period, the fi re turns OFF. The
CountdownTimer only works in Manual, Thermostatic, and
Random modes. Maximum countdown time is 9 hours.
PROGRAM MODE
NOTE: The set temperature for Thermostatic Mode is the tem-
perature for the ON time in Program Mode. Changing
the Thermostatic Mode set temperature also changes
the ON time temperature in Program Mode.
ON:
AM
PM
ON
OFF
1 2
Press
displayed.
button. , or , ON or OFF
Time SETTING:
AM
PM
ON
OFF
1 2
1. Press
2. To select hour press
3. To confi rm press
button and hold until , ,
displayed, hour fl ashes.
or button.
button. , dis-
played, minutes fl ash.
4. To select minutes press
or but-
ton.
AM
PM
ON
OFF
1 2
5. To confi rm press button. , ,
displayed, hour fl ashes.
6. To select hour, press
7. To confi rm press
or button.
button. , ,
displayed, minutes fl ash.
8. To select minutes press
or but-
ton.
NOTE: If you stop programming at this point, program 2 remains
deactivated.
NOTE: Programs 1 and 2 use the same ON (Thermostatic) and
OFF temperatures.
8-SYMBOL
© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
21 / 28
OPERATING INSTRUCTIONS FOR OEM USE ONLY
1.
To continue to program , press
AM
PM
ON
OFF
1 2
button.
fl ashes.
2. To select hour press
3. To confi rm press
, ,
displayed, hour
button. , ,
displayed, minutes fl ash.
4. To select minutes, press
ton.
5. To confi rm press
button. , ,
displayed, hour fl ashes.
6. To select hour, press
7. To confi rm press
button. , ,
displayed, minutes fl ash.
8. To select minutes, press
ton.
9. To confi rm press
NOTE: Programs
and use the same ON and OFF tempera-
button or wait.
tures. Once an ON and/or OFF temperature has been
set, that temperature becomes the new default setting.
RANDOM FLAME
ON:
AM
Press
played.
button. Random icon dis-
or button.
or but-
or button.
or but-
CHILD PROOF
ON:
AM
PM
ON
OFF
1 2
To activate press
multaneously. Children icon displayed
and the handset is rendered inoperable, except for the OFF function.
OFF:
To deactivate press
and buttons si-
and buttons
simultaneously. Children icon disappears.
OFF:
Press
button. Random icon disap-
pears.
NOTE: Mains adapter recommended.
AUXILIARY FEATURE
Upon ignition burner 1 is ON and burner 2 is in the last setting.
OFF:
AM
PM
ON
OFF
1 2
To switch the burner OFF, press the
button (Auxiliary icon disappears).
ON:
To switch a burner ON, press the button.
NOTE: The latching solenoid valve cannot operate manually. If
the receiver battery runs down it will remain in the last
operating position.
22 / 28
© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
OPERATING INSTRUCTIONS FOR OEM USE ONLY
10- SYMBOL
Countdown Timer
Program Mode
1 2
Figure 23: 10-symbol Display
SETTING CELSIUS OR FAHRENHEIT
To change between °C and °F, press
AM
PM
ON
OFF
1 2
SETTING THE TIME
AM
PM
ON
OFF
1 2
and buttons simultaneously.
NOTE: Choosing °F results in a 12 hour
clock. Choosing °C results in a
24 hour clock.
1. Press and buttons simultane-
ously. Hour fl ashes.
2. To select hour press
3. Press
and buttons simultane-
ously. Minutes fl ash.
4. To select minutes press
ton.
5. To confi rm press
simultaneously or wait.
Time
ON
OFF
Temperature
or button.
or but-
and buttons
Signal Indicator Child Proof
Thermostatic Mode
AM
PM
Auxiliary Feature
MODES OF OPERATION
AM
PM
ON
OFF
1 2
AM
PM
ON
OFF
1 2
Battery Status
Fan
°F or °C
Light
Random Mode
Enter Mode
Press the appropriate mode button.
Exit Mode
1. Press the same mode button again to
change to Manual mode.
2. Press
or button to change to
Manual mode.
3. Press a different mode button to
change to that mode.
Thermostatic Mode
The room temperature is measured and
compared to the set temperature. The
fl ame height is then automatically ad-
justed to achieve the set temperature.
10-SYMBOL
© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
AM
PM
ON
OFF
1 2
Program Mode
Programs 1 and 2, each can be pro-
grammed to go ON and OFF at specifi c
times at a set temperature.
23 / 28
OPERATING INSTRUCTIONS FOR OEM USE ONLY
Random Mode
AM
Flame height changes automatically.
NOTE: Mains adapter recommended.
MANUAL MODE (HANDSET)
NOTICE
BEFORE OPERATING
1. Make sure MANUAL knob on the GV60 Valve is in the ON,
full counterclockwise
position.
2. Place the ON/OFF switch (if equipped) in the “ I” (ON position).
TO TURN ON FIRE
FLAME HEIGHT ADJUSTMENT
Handset
AM
PM
ON
OFF
1 2
▪ To increase fl ame height press and
hold
button.
▪ To decrease fl ame height or to set ap-
pliance to pilot fl ame, press and hold
button.
DESIGNATED LOW FIRE AND HIGH FIRE
▪ To go to low fi re, double-click but-
AM
ton. “LO” is displayed.
NOTE: Flame goes to high fi re fi rst be-
fore going to low fi re.
When pilot ignition is confi rmed, motor turns automatically to
maximum fl ame height.
Handset
AM
PM
ON
OFF
1 2
▪ Press
fi rms the start sequence has begun;
release button.
▪ Continuing beeps confi rm ignition is in
button until a short beep con-
process.
▪ Rotating circle is shown on display un-
til ignition sequence is complete.
▪ There is main gas fl ow once pilot igni-
tion is confi rmed.
▪ Handset automatically goes into Man-
ual mode after main burner ignition.
If the pilot does not stay lit after several tries, turn the main valve
knob to OFF and follow the instructions “TURN OFF GAS TO
APPLIANCE ” (page 28).
Standby Mode (Pilot Flame)
Handset
▪
Press and hold
button
to set appliance to pilot fl ame.
▪ To go to high fi re, double-click but-
AM
ton. “HI” is displayed.
If the appliance will not operate, follow the instructions “TURN
OFF GAS TO APPLIANCE”
(page 28)
.
TO TURN OFF FIRE
AM
PM
ON
OFF
1 2
24 / 28
Handset
▪ Press
button to turn off
.
NOTE: There is a 5 sec delay before
the next ignition is possible.
© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
OPERATING INSTRUCTIONS FOR OEM USE ONLY
THERMOSTATIC MODE
ON:
AM
PM
ON
OFF
1 2
Press
played, preset temperature displayed
briefl y, and then room temperature dis-
played.
OFF:
1. Press
2. Press
mode.
3. Press
Timer mode.
4. Press
mode.
SETTING:
AM
PM
ON
OFF
1 2
1. Press
mostat icon displayed, temperature
fl ashes.
2. To adjust SET temperature press
or
3. To confi rm press
button. Thermostat icon dis-
button.
or button to enter Manual
button to enter Countdown
button to enter Random
button and hold until Ther-
button.
button or wait.
OFF:
AM
PM
ON
OFF
1 2
1. Press
Manual mode.
2. Press
mode.
or or button to enter
button to enter Thermostatic
3. Press Random icon button to enter
Random mode.
PROGRAM Temperature SETTING:
AM
PM
O N
O FF
1 2
1. Press
displayed.
2. To continue press
button and hold until ,
, Set temperature (Thermostatic)
button. ,
displayed, temperature fl ashes and
wait.
3. To select OFF temperature press
or
button.
4. To confi rm press
button or wait.
NOTE: The ON (Thermostatic) and OFF set temperatures are
the same for each day.
COUNTDOWN TIMER
ON/SETTING:
AM
PM
ON
OFF
1 2
1. Press and hold
glass icon displayed and hour fl ashes.
2. To select hour press
3. To confi rm press
button until hour-
or button.
button. Minutes
fl ash.
4. To select minutes press
or but-
ton.
5. To confi rm press
button or wait.
OFF:
Press
button, hourglass and count-
down time disappear.
NOTE: At end of countdown time period, the fi re turns OFF. The
CountdownTimer only works in Manual, Thermostatic, and
Random modes. Maximum countdown time is 9 hours.
PROGRAM MODE
NOTE: The set temperature for Thermostatic Mode is the tem-
perature for the ON time in Program Mode. Changing
the Thermostatic Mode set temperature also changes
the ON time temperature in Program Mode.
Time SETTING:
AM
PM
ON
OFF
1 2
1. Press
2. To select hour press
3. To confi rm press
button and hold until , ,
displayed, hour fl ashes.
or button.
button. , dis-
played, minutes fl ash.
4. To select minutes press
or but-
ton.
AM
PM
ON
OFF
1 2
5. To confi rm press button. , ,
displayed, hour fl ashes.
6. To select hour, press
7. To confi rm press
or button.
button. , ,
displayed, minutes fl ash.
8. To select minutes press
or but-
ton.
NOTE: If you stop programming at this point, program 2 remains
deactivated.
NOTE: Programs 1 and 2 use the same ON (Thermostatic) and
OFF temperatures.
10-SYMBOL
ON
OFF
1 2
© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
ON:
AM
PM
Press
displayed.
button. , or , ON or OFF
25 / 28
OPERATING INSTRUCTIONS FOR OEM USE ONLY
1.
To continue to program , press
AM
PM
ON
OFF
1 2
button.
fl ashes.
2. To select hour press
3. To confi rm press
, ,
displayed, hour
button. , ,
displayed, minutes fl ash.
4. To select minutes, press
ton.
5. To confi rm press
button. , ,
displayed, hour fl ashes.
6. To select hour, press
7. To confi rm press
button. , ,
displayed, minutes fl ash.
8. To select minutes, press
ton.
9. To confi rm press
NOTE: Programs
and use the same ON and OFF tempera-
button or wait.
tures. Once an ON and/or OFF temperature has been
set, that temperature becomes the new default setting.
CIRCULATING FAN OPERATION
NOTE: SETTING only. Fan is switched
AM
ON automatically when gas
opens. Circulating fan has 4
speed levels from low (1 bar) to
high (4 bars).
or button.
or but-
or button.
or but-
RANDOM FLAME
ON:
AM
Press
played.
button. Random icon dis-
OFF:
Press
pears.
button. Random icon disap-
NOTE: Mains adapter recommended.
AUXILIARY FEATURE
Upon ignition burner 1 is ON and burner 2 is in the last setting.
OFF:
AM
PM
ON
OFF
1 2
To switch the burner OFF, press the
button (Auxiliary icon disappears).
ON:
To switch a burner ON, press the button.
SETTING:
1. Press
button and hold until fan
icon fl ashes.
2. Press
and
button to increase fan speed
button to decrease fan speed.
3. To confi rm setting either press
ton or wait (Fan icon displayed).
OFF:
Press
button until all 4 speed level
bars disappear.
LIGHT/DIMMER OPERATION
ON:
AM
Press
Light is on at preset level.
button (light icon displayed).
OFF:
Press
button (light icon disappears) .
SETTING:
1. Press
button and hold until light
icon fl ashes.
2. To adjust light between 20…100 %
press
or button.
3. To confi rm setting either press
ton or wait (Light icon displayed).
but-
but-
NOTE: The latching solenoid valve cannot operate manually. If
the receiver battery runs down it will remain in the last
operating position.
CHILD PROOF
ON:
AM
PM
ON
OFF
1 2
To activate press
multaneously. Children icon displayed
and the handset is rendered inoperable, except for the OFF function.
and buttons si-
OFF:
To deactivate press
and buttons
simultaneously. Children icon disappears.
NOTE: The Light works independently of the Pilot fl ame. If you
want the light ON but no fl ame, press
button.
26 / 28
© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
OPERATING INSTRUCTIONS FOR OEM USE ONLY
TOUCH PAD / WALL SWITCH
Increase fl ame height
ON-OFF
Decrease fl ame height
Figure 24: Touch Pad / Wall Switch
To Turn ON Appliance
▪ Press
button (see fi gure 24) until a short beep con-
fi rms the start sequence has begun; release button.
▪ Continuing beeps confi rm the ignition is in process.
▪ Once pilot ignition is confi rmed, there is main gas fl ow.
If the pilot does not stay lit after several tries, turn the main
valve knob to OFF and follow the instructions “TO TURN OFF
GAS TO APPLIANCE ” (page 28).
SWITCH PANEL
A) Increase fl ame height
B) ON/OFF
C) Decrease fl ame height
Figure 25: Switch Panel
To Turn ON Appliance
▪ Press “B” button (see fi gure 25 ) until a short beep confi rms the
start sequence has begun; release button.
▪ Continuing beeps confi rm the ignition is in process.
▪ Once pilot ignition is confi rmed, there is main gas fl ow.
If the pilot does not stay lit after several tries, turn the main
valve knob to OFF and follow the instructions “TO TURN OFF
GAS TO APPLIANCE” (page 28 ).
STANDBY MODE (PILOT FLAME)
▪ Press and hold
(small fl ame) button to set appliance at pilot
fl ame.
To Turn OFF Appliance
▪ Press
button.
Flame Height Adjustment
▪ Press and hold
▪ Press and hold
(large fl ame) button to increase fl ame height.
(small fl ame) button to decrease fl ame height
or to set appliance at pilot fl ame.
▪ For fi ne adjustment tap
(large fl ame) or (small fl ame) button.
If the appliance will not operate, follow the instructions “TO
TURN OFF GAS TO APPLIANCE”
(page 28)
.
TO OPEN AND CLOSE SOLENOID VALVE/BURNER
▪ Upon ignition Main Burner and Decorative Burner are ON.
▪ Simultaneously press the
and (small fl ame) buttons
to switch the Decorative Burner OFF.
▪ Simultaneously press
and (large fl ame) buttons but-
tons to switch Decorative Burner ON.
NOTE: The latching solenoid valve cannot operate manually. If
the receiver battery runs down it will remain in the last
operating position. During normal operation the solenoid
valve will be reset to the ON position when the GV60 is
switched OFF remotely.
STANDBY MODE (PILOT FLAME)
▪ Press and hold “C” button to set appliance at pilot fl ame.
To Turn OFF Appliance
▪ Press “B” button.
Flame Height Adjustment
▪ Press and hold “A” button to increase fl ame height.
▪ Press and hold “C” button to decrease fl ame height or to set
appliance at pilot fl ame.
▪ For fi ne adjustment tap button “A” or “C” button.
If the appliance will not operate, follow the instructions “TO
TURN OFF GAS TO APPLIANCE”
(page 28)
.
© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
27 / 28
OPERATING INSTRUCTIONS FOR OEM USE ONLY
Piezo ignitor
(optional)
Connection
piezo ignitor tab
2.8 x 0.8 mm
ON/OFF switch
(optional) in
ON Position
8 Wire
Receiver jack
MANUAL knob
in MAN position
Manual pilot
valve operator
Microswitch
Main valve knob
in OFF position
Figure 25: Combination control, cover
MANUAL OPERATION
(Only possible, when MANUAL knob is used)
Access to the pilot burner is only required for ignition with a match.
When turning main valve knob, do not force. Knob has a slip
clutch that clicks until the end stops are reached. This allows for
manual fl ame height adjustment as well as adjustment to pilot
standby position.
9. If applicable, replace pilot access panel before proceeding.
10. Turn MANUAL knob to the
ON
, full counterclockwise
position.
11. Turn main valve knob to the full
ON
, full counterclockwise
position.
12. If the appliance will not operate, follow the instructions “TO
TURN OFF GAS TO APPLIANCE” (below ).
TO TURN OFF GAS TO APPLIANCE
1. Place ON/OFF switch (if equipped) in
O (OFF position).
2. If gas control is accessible turn main valve knob to the OFF full
clockwise
position.
3. Replace appliance access cover (if applicable).
AUTOMATIC TURN DOWN
3 Hour No Communication Function
▪ The valve will turn to pilot fl ame if there is n o communication
between handset and receiver for a 3 hour period. The fi re will
continue to function normally when communication is restored.
Receiver Overheating
(only if module is connected)
▪ Valve turns to pilot fl ame if the temperature in the receiver is
higher than 140 °F (60 °C). The main burner turns back ON
(manually or in thermostatic mode) only when the temperature
is below 140 °F (60 °C).
1. STOP! Read the safety information included before proceeding.
2. Turn main valve knob to the
3. Turn MANUAL knob to the
OFF
, full clockwise position.
MAN
, full clockwise position.
4. Place ON/OFF switch (if equipped) in O (OFF position).
5. Wait fi ve (5) minutes to clear out any gas. Verify that no gas
is in the area around the appliance, including near the fl oor.
If you detect gas STOP! Follow “WHAT TO DO IF YOU
SMELL GAS” in the safety information on page 2. If no gas
is present, proceed to step 6.
6. Place ON/OFF switch (if equipped) in “
7. With the MANUAL knob in
MAN
I
” (ON position).
position a manual pilot valve
operator and piezo ignitor (optional) are accessible.
8. Fully push down manual pilot valve operator and hold in, to
start pilot gas fl ow (see fi gure 2 5).
Ignition with match:
Immediately light the pilot with a match, while continuing to
hold in the manual pilot valve operator for about one (1) minute
after the pilot is lit. Release manual pilot valve operator. If pilot
does not stay lit, wait fi ve (5) minutes and repeat.
Ignition with piezo ignitor:
Change the ignition cable from the receiver to the valve (see
fi gure 25 ). Push in the piezo ignitor to ignite. If pilot does not
stay lit, wait fi ve (5) minutes and repeat.
If the pilot does not stay lit after several tries, turn the gas
control knob (main valve knob) to OFF and proceed to step 12.
1 Hour Turn Down for Special Receiver
(bedroom fi replaces only)
▪ The valve will turn to pilot fl ame if there is no change in fl ame
height over a 1 hour period.
AUTOMATIC SHUT OFF
Countdown Timer
▪ At end of countdown time period, the fi re turns OFF. The Count-
downTimer only works in Manual, Thermostatic, and Random
modes. Maximum countdown time is 9 hours.
Low Battery Receiver
▪ With low battery power in the receiver the system shuts off the
fi re completely. This will not happen if the power supply is inter-
rupted.
Five Day Shut Off
(CSA version)
▪ The system shuts off the fi re completely if there is no change in
fl ame height for 5 days.
nd
2
Thermocouple Shut Off
nd
▪ 2
thermocouple Option: The system shuts OFF the fi re if the
main burner does not completely ignite approximately 20 seconds after ignition or after pushing
button.
NOTE: Before the next ignition there is a 2 minute waiting period.
R
Mertik Maxitrol GmbH & Co. KG
Warnstedter Str. 3, 06502 Thale, Germany
Tel: + 49 3947 400-0, Fax: + 49 3947 400-200
www.mertikmaxitrol.com
GV60 -II.OI- EN-10.2013- Syma x
28 / 28
Exclusive Distributor North America for Mertik Maxitrol
Maxitrol Company, Inc.
23555 Telegraph Rd., PO Box 2230,
Southfield, MI 48037-2230, USA
Tel: +1 248-356-1400, Fax: +1 248-356- 0829
www.maxitrol.com
R
© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.