R
GV60 Remote Electronic Ignition and Control System External Source Operation
OPERATING INSTRUCTIONS - FOR OEM USE ONLY
GENERAL NOTES
Fire or explosion hazard. Attempted disassembly or repair of controls can cause property damage, severe injury or death. Do not disassemble the gas valve; it contains no serviceable components.
An Alex 2510-Z connector (not supplied) must be used to connect to the receiver. Signal relays (gold contacts) or opto-couplers are recommended.
Draft September 16, 2008
Read these instructions carefully. Failure to follow them could result in a re or explosion causing property damage, personal injury, or loss of life. The product must be installed and operated according to all local regulations.
BEFORE OPERATING verify that no gas is in the area around the appliance, including near the floor.
WHAT TO DO IF YOU SMELL GAS:
Do not light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call the gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach the gas supplier, call the fire department.
fire or explosion.
Do not use this control or any gas appliance if any part has been under water or Immediately call a qualified service technician to replace the control system and any gas control system which has been under water or in contact with water.
in contact with water.
Beginning in 2008, receivers produced with the part num­ber G6R-R3 (or 4) A2… will have the capability of external source operation.
OPERATING INSTRUCTIONS
It is the appliance manufacturer‘s responsibility to fully disclose any operation from a remote source that will create an unsafe operating condition. For Europe see GADAC guidance sheet B12.
SEQUENCE OF OPERATION
(see figure 1)
To start Ignition, close contacts 1 and 3 simultaneously
for 1 second.
To set the valve to High Fire, close contact 1.
To set the valve to Pilot, close contact 3.
In each case, the contacts need to be closed for 12 seconds to turn the motor from one end-stop to the other end-stop.
To set the valve to the Off position, close contacts 1, 2,
and 3 simultaneously for 1 second.
APPLICATION
The GV60 will operate through an external source, such as a home automation system, by using the 5-wire pin connector on the receiver.
© 2008 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
DRAFT
Mode Contact
High Fire 1
Pilot 3
Ignition 1 and 3
Turn Off 1, 2 and 3
3
2
1
Figure 1: Wiring diagram and the operation sequence to achieve different
settings
Wire Colors: 1 = red wire 2 = brown wire 3 = black wire 4 = orange wire
1 / 2
R
GV60 - Operating Instructions
POSSIBLE MODES OF OPERATION
1. The external source provides "ON" and "OFF" opera­tion only. The Timer/Thermostat Handset provides all other functions. The Standard handset has no timer/ thermostat function.
NOTE:
Use with Timer/Thermostat Handset*
When the valve is turned "OFF" by an external source
or handset, upon re-ignition it will go automatically into
temperature control mode (CSA-versions) or manual mode (CE-versions).
Use with Standard Handset*
The valve will always default to manual mode upon re-
ignition.
*See operating instructions for the different handsets.
2. A Standard Handset can be used where the external source has the capability to take over the temperature control.
Draft September 16, 2008
NOTE:
Mertik Maxitrol offers an optional AC power adapter (G60
ZMAUS2 for North America and G60 ZMEU2 for Europe.
DRAFT
Mertik Maxitrol GmbH & Co. KG Warnstedter Str. 3, 06502 Thale, Germany
GV60-OI-EN-09.2008-EXT_SOURCE
2 / 2
www.mertikmaxitrol.com
© 2008 Mertik Maxitrol GmbH & Co. KG