Mertik Maxitrol GV34 Operating Instructions Manual

APPLICATION
GV34 is a servo motor operated valve with remote control
allowing for innite adjustment from low re to high re.
GENERAL NOTES
Radio Frequency Remote 868 MHz for Europe; 915 MHz for U.S. (FCC ID:UX5-
R300) and for Canada (IC: 4943B-R300).
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired opera­tion. Changes or modications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Batteries - Remote Handset:
2 x 1.5 V “AAA” (quality alkaline recommended)
Batteries - Receiver:
4 x 1.5V “AA” (quality alkaline recommended) An AC Ma i n s Adap t er may be us e d instea d of
batteries (only the Mertik Maxitrol or an AC Mains Adapter approved by Mertik Maxitrol can be used).
1
STANDARD MODEL OPERATING INSTRUCTIONS - FOR OEM USE ONLY
Fire or explosion hazard. Attempted disassembly or repair of controls can cause property damage, severe injury or death. Do not disassemble the gas valve; it contains no serviceable components.
Read these instructions carefully. Failure to follow them could result in a re or explosion causing property damage, personal injury, or loss of life. The product must be installed and oper­ated according to all local regulations.
BEFORE OPERATING verify that no gas is in the area around the appliance, including near the oor.
WHAT TO DO IF YOU SMELL GAS:
Do not light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call the gas supplier from a neighbor ’s phone. Follow the gas supplier’s instructions. If you cannot reach the gas supplier, call the re department.
Use only your hand to push in or turn the gas control knobs. Never use tools. If a knob will not push in or turn by hand, don’t try to repair it, call a qualied service technician. Force or attempted repair may result in a re or explosion.
Do not use this control or any gas appliance if any part has been under water or in contact with water. Immediately call a qualied service technician to replace the control system and any gas control system which has been under water or in contact with water.
Battery Replacement
Battery replacement is recommended at the beginning of each heating season. Do not use metal tools to remove batteries. Using a metal tool could cause a short that may damage the receiver.
Location of Receiver
When the RF- rec eiv er is placed in the app lia nce , the surrounding metal can reduce reception considerably.
NOTE: During a power outage the AC Mains Adapter must be unplugged from the receiver to operate in the battery mode.
GV34 Remote Control
R
© 2009 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
Figure 1: R300 Standard Model, Patented
GV34 - Operating Instructions
2
© 2009 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
INITIAL SETUP - PROGRAMMING MODE
Press
(both buttons) and hold for 5 seconds
(until screen blinks) to enter Programming Mode.
• PressPress
(down) to scroll through menu items.
• Press
(up) to adjust menu items.
SETTING ºF OR ºC
1. Press (up) button to choose either ºF or ºC.
• Press (down) button to set and scroll to the next menu item.
SETTING 12 HOUR OR 24 HOUR MODE
2. Press (up) button to choose either “12” or “24”.
• Press (down) button to set and scroll to the next menu item.
SETTING THE HOUR
3. Press (up) button to set the Hour, 1-12 or 0-23.
NOTE: Use right (up) button only. Num-
bers scroll up (1, 2, 3, ..) to 12 or 23 then cycle back to 1 or 0.
• Press (down) button to set and scroll to the next menu item.
STANDARD HANDSET FEATURES
LCD Icon Feature and Description
Sleep Mode Icon.
After 8 hours of no signal between the handset and the receiver, valve runs to pilot and Sleep Mode icon is displayed.
Ambient Temperature Display: Indicates the current room temperature. ºF or ºC
Child Safety Lock: When ON (icon showing), the right button must be pushed twice within
0.5 seconds to increase the ame height.
Battery Life Indicator: 4 bars indicates a ful­ly charged battery.
Clock Mode: Set to 12 or 24 hour clock.
Communication Indicator: Indicates the handset is transmitting to the receiver.
INITIAL SETUP
SETTING THE ELECTRONICS CODE
Radio Frequency Remote
A code is selected automatically for all Mertik Maxitrol electronics from among 65,000 random codes available.
On initial and subsequent receiver battery changes, the re­ceiver has to learn the code of the handset:
Power up Handset.
Power up Receiver (LED blinks).
While blinking, press any button.
When the Receiver LED stops blinking, the code is set.
NOTE:
These remote handset and receiver are not inter-
changeable with previous versions. For all lighting instructions please refer to appliance manufacturer‘s instructions.
Figure 2: R300 Standard Model, Patented
Figure 3: R300 Standard
Model Icons
READ THROUGH THIS ENTIRE WARNING BEFORE ATTEMPTING INITIAL SETUP / PROGRAMMING.
A red number/icon indicates the icon is blinking. This will help determine which menu item is being set or programmed.
When programming a menu item, use the right (up) button ONLY. Pressing the left (down) button will cause the program­ming menu to skip to the next menu item. If you accidentally skip to the next menu item, you must cycle through all the menu items to return to the item you were programming.
Adjusting a menu item, the number will scroll up only (1, 2, 3...) and will cycle back to the beginning number.
15 seconds of inactivity will cause the remote to auto­matically go to operation mode. Follow Step 1. INITIAL SETUP - PROGRAMMING MODE (pg. 3) to return to programming mode. Any changes will be saved each time you exit programming mode.
GV34 - Operating Instructions
3
© 2009 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
INITIAL SETUP - PROGRAMMING MODE CONT.
SETTING THE MINUTES
4. Press (up) button to set Minutes, 00-59.
NOTE: Use right (up) button only. Numbers
scroll up (1, 2, 3...) to 59 then cycle back to 00.
• Press (down) button to set and scroll to the next menu item.
SETTING CHILD SAFETY LOCK
5. Set Child Safety Lock either ON or OFF.
Press
(up)button to set Child
Safety Lock ON (icon showing) or OFF.
9. This concludes your basic programming. The remote will automatically save your changes and go into operation mode after 15 seconds of inactivity.
STANDARD HANDSET OPERATION
FLAME HEIGHT ADJUSTMENT
• To turn the main burner ON or to increase the ame
height, press the (up) button.
• To decrease the ame height, press the
(down) button or turn main burner OFF.
SLEEP MODE
After 8 hours of no signal between the handset and the receiv-
er, valve runs to pilot and Sleep Mode icon is displayed.
TURN OFF GAS TO APPLIANCE
Access the gas control.
Turn the main valve knob clockwise to the PILOT position. Push in knob; turn and release. Continue turning
to the OFF full clockwise
position.
Replace appliance accessibility cover (if applicable).
MANUAL VALVE OPERATION
Access to the pilot burner is only required for ignition with a match.
1. STOP! Read the safety information included before proceeding.
2. Turn main valve knob to the OFF, full clockwise position.
3. Turn MANUAL knob to the full clockwise position.
4. Wait ve (5) minutes to clear out any gas. Verify that no gas is in the area around the appliance, including near the oor.
If you detect gas STOP! Follow Warnings (see pg. 1) under “What to do if you smell gas”. If no gas is present,
proceed to step 5.
5. Turn main valve knob slightly counterclockwise towards the IGN position until it stops, then press down and continue
turning counterclockwise
to the pilot position. Con­tinue to hold down knob for 10 seconds after pilot burner has been lit. If pilot does not light, steps 1 and 2 may be repeated.
NOTE: If the pilot does not stay lit after several tries, turn
main valve knob to the PILOT position. Push in knob; turn and release. Continue turning to the OFF full clockwise
position and proceed to step 7.
6. Upon lighting, release knob and turn main valve knob fully counterclockwise
to ON position.
7. If the appliance will not operate, follow the instructions “Turn Off Gas to Appliance”.
MANUAL FLAME HEIGHT OPERATION
The motorized valve is equipped with a slip clutch allowing manual adjustment of the main burner by turning the manual knob. When turning the manual knob, do not force.
STANDBY PROCEDURE
Turn main valve knob clockwise to Pilot position, allow­ing only pilot gas to ow.
GV34 - Operating Instructions
Combination Control GV Series (with Motor)
Microswitch
MANUAL Knob in ON Position
Main Valve
Knob In OFF
Position
Figure 5: Combination Control
Figure 4: Wiring Diagram for OEM use only
GV34-ST-OI-EN-05.2009
4
Mertik Maxitrol GmbH & Co. KG Warnstedter Str. 3, 06502 Thale, Germany
www.mertikmaxitrol.com
© 2009 Mertik Maxitrol GmbH & Co. KG
All Rights Reserved.
R
4 Wire Connecting Cable
Receiver
G30-ZRCP Connecting Cable to xed (mains) electrical supply
AC Adapter Output: 6V DC,100 mA
Handset
To keep receiver free from debris and dirt, do not remove the receiver from the plastic bag until all construction is complete.