Mersen, formerly Ferraz Shawmut RF, RFS, RL Catalog Page

Page 1
RENEWABLE
TRADITIONAL PROTECTION FOR CIRCUITS WITH LESS THAN 10,000A SHORT CIRCUIT CURRENT
RF and RFS general purpose fuses are suitable for application where available short circuit cur­rents do not exceed 10,000 amperes. RF and RFS renewable fuses use matched RL and RLS die-cut zinc links from 1 to 600 amperes in 32 ratings.
Features/Benefits
Knurled bushings for ease of disassembly
➤
Rugged construction for maximum service life
➤
HIGHLIGHTS:
Renewable
➤
32 Renewal Link
➤
Ratings
APPLICATIONS:
General purpose loads
➤
where short circuits are 10,000 amperes or less
Precision die-cut renewal links renew quickly and
➤
give repeatable performance
Ratings
RF
➤
AC: 1 to 600A 250VAC, 10kA I.R.
RFS
➤
AC: 1 to 600A 600VAC, 10kA I.R.
Approvals
UL Listed to Standard
➤
248-7 File E2137
CSA Certified to
➤
Standard C22.2 No. 248.7
B 42
Page 2
RENEWABLE CLASS H FUSES/LINKS RF/RFS & RL/RLS
Standard Fuse Ampere Ratings, Catalog Numbers
Ampere Catalog Number Ampere Catalog Number Ampere Catalog Number
Rating 250V 600V Rating 250V 600V Rating 250V 600V
1 RF1/RL1 RFS1/RLS1 45 RF45/RL45 RFS45/RLS45 225 RF225/RL225 RFS225/RLS225 2 RF2/RL2 RFS2/RLS2 50 RF50/RL50 RFS50/RLS50 250 RF250/RL250 RFS250/RLS250 3 RF3/RL3 RFS3/RLS3 60 RF60/RL60 RFS60/RLS60 300 RF300/RL300 RFS300/RLS300 5 RF5/RL5 RFS5/RLS5 70 RF70/RL70 RFS70/RLS70 350 RF350/RL350 RFS350/RLS350 6 RF6/RL6 RFS6/RLS6 80 RF80/RL80 RFS80/RLS80 400 RF400/RL400 RFS400/RLS400 10 RF10/RL10 RFS10/RLS10 90 RF90/RL90 RFS90/RLS90 450 RF450/RL450 RFS450/RLS450
15 RF15/RL15 RFS15RLS15 100 RF100/RL100 RFS100/RLS100 500 RF500/RL500 RFS500/RLS500 20 RF20/RL20 RFS20/RLS20 110 RF110/RL110 RFS110/RLS110 600 RF600/RL600 RFS600/RLS600 25 RF25/RL25 RFS25/RLS25 125 RF125/RL125 RFS125/RLS125 30 RF30/RL30 RFS30/RLS30 150 RF150/RL150 RFS150/RLS150 35 RF35/RL35 RFS35/RLS35 175 RF175/RL175 RFS175/RLS175 40 RF40/RL40 RFS40/RLS40 200 RF200/RL200 RFS200/RLS200
Recommended Fuse Blocks With Box Connectors For Renewable Class H Fuses
Fuse Catalog Number Ampere 250V 600V Rating 1 Pole 3 pole 1 pole 3 pole
0-30 20306 20308 60306 60308 31-60 20606 20608 60606 60608
61-100 21036 21038 61036 61038 101-200 22001 22003 62001 62003 201-400 24001 24003 64001 64003 401-600 2631 2633 6631 6633
0-60A
B
A variety of pole configurations and termination provisions is avail­able. Refer to the fuseholder section of this catalog for details.
Dimensions
AMPERE A B C D E RATING In. mm In. mm In. mm In. mm In. mm 250V-RF FUSES
0-30 2 51 9/16 14 - - - - - - 31-60 3 76 13/16 21 - - - - - - 61-100 5-7/8 149 1-1/16 27 1/8 3 3/4 18 1 25 101-200 7-1/8 181 1-9/16 40 3/16 5 1-1/8 28 1-3/8 35 201-400 8-5/8 219 2-1/16 54 1/4 6 1-5/8 41 1-7/8 48 401-600 10-3/8 264 2-9/16 66 1/4 6 2 51 2-1/4 57
600V-RFS FUSES
0-30 5 127 13/16 21 - - - - - - 31-60 5-1/2 139 1-1/16 27 - - - - - - 61-100 7-7/8 200 1-5/16 34 1/8 3 3/4 18 1 25 101-200 9-5/8 244 1-13/16 46 3/16 5 1-1/8 28 1-3/8 35 201-400 11-5/8 295 2-9/16 67 1/4 6 1-5/8 41 1-7/8 48 401-600 13-3/8 340 3-1/8 80 1/4 6 2 51 2-1/4 57
61-600A
B 43B 43