Merrytek Technology MC612VDRC User Manual

MC612V D RC
Lighting Control Switch USER’S MANUAL
Model No.:MC612V D RC
MC612 V D RC
GENERALGUIDELINESFORINSTALLATION
1, The s ensor s hou ld be instal led by a qu ali fied el ect rician. An d ensure
the product .
2, The c ompan y doe s not acc ept respon sibility f or any conse quences
resulting f rom una uthorize d modifica tion of the product .
3, MC6 12V D RC sh oul d be conn ect ed to a sta ble p ower su ppl y of
120/ 277Vac, 50 Hz/ 60Hz.
4, Mic rowav es cannot pa ss thro ugh metal or b rick walls i f thicker th an
20cm . They wi ll pa ss thro ugh thinne r walls but th ere wil l be some
atte nuation.
5, Ins talla tio n insid e a gla ss or pla sti c housi ng wi ll resu lt in a red uction of
dete ction sens itivity. Expect a r eduction o f appro ximately 2 0% for every
3mm of thickness. 6, The sensor is designed for indoor use only. The raining or wind blowing
may trigger the Lighting Control Switch even if without human motion when
outdoor use.
7, Detection area will be affected by speed of motion,height of installation and
volume of moving object.
8, Daylight sensor was tested on sunny environment with no lampshade.
INSTALLATION & WIRING
The senso r ha s 6- positi on t erminal bl oc ks : L(Phase ) N( Neutral) L’ (S wi tc he d ph as e / co nt ro l) 0-10V(+,-) (Connect ed t o 0- 10 V in te rf ac e)
The senso r is d es ig ne d fo r in st al la ti on a t 8. 2f t~ 26.2ft /2.5- 8m i n he ig ht .
INSTALLATION
Main se ns or i ns ta ll at io n Detachable se ns or i ns ta ll at io n me th od 1
Install the sen so r on t he L ED plate by us in g 2 sc re ws
M0.12 x0 .3 1i n/ 3. 0x 8m m Sc re w M0.12 x0 .3 1i n/ 3. 0x 8m m Sc re w
Make tw o ho le s on t he L ED p la te , p us h the s en so r in to t he h ol es .
0.5 5in/1 4mm
The h ole dim ensio n: φ 0.1 2in/3 mm
The h ole dim ensio n:
9mm (0. 35in)
3mm (0. 12in)
2X 2X
Main se ns or insta ll at io n
Install the sen so r on t he LED plate by using 2 scre ws
WIRING SCHE ME
Detac ha bl e se ns or i ns ta ll at io n me th od 2
Step 1: C ut t he f ol lo wi ng b uc kl e and the l it tl e pa rt o ff .
the l ittle p art
Step 2: P la ce t he s en so r to wa rd s to t he floor a nd f ix i t on t he L ED p la te b y sc re ws .
The h ol e of t he w ir e is 0 .1 5i n/ 3. 7m m.
M0.1x0.31in /2 .5 x8 mm S cr ew
SECSECSEC
0-1 0V Dimm able 0-1 0V Dimm able
0-1 0V Dimm able
LED D riverLED D river
LED D river
the f ollow ing buc kle
2X
MI201 80 13 1A 0
FEATURES
Sens or p arame te rs ca n be c onven ie ntly se t by a remote c ontroll er.
The mi ni m otion d et ect or i s separ at ely f ro m se nsor po wer par t, i t
will b e ea sier to f ix m oti on d etect or o n the s ur face of t ri -proo f li ght
and hi dd en the po we r par t be hind it .
This s en sor is pa rt icu la rly des ig ned f or t he ligh ts w hich ha ve limi te d
spac e, f or exam pl es, L ED l inear, batte n, and LE D tr i-pro of l ights .
Usin g pl uggab le d esi gn b etwee n mo tio n de tecto r an d power p art,
easy t o re in stall o r maint ai n.
0-10 V in terfa ce c an ma tc h up with M er rytek s tand- al one day light
harv es ting se ns or Ms 01 .
SPECIFICATIONS
Operat in g vo lt age
Rated Lo ad
HF syste m
Tran sm ittin g po we r
Power co ns um pt ion
Detection Range(Diameter)
Max. Mou nt in g he ight
Hold tim e
Stand- by P er io d
Stand- by D IM L ev el
Daylig ht s en so r
Operat in g te mp erature
IP ratin g
UL file nu mb er E4 89677
120/27 7Vac, 50/60 Hz
120Vac 5 0/ 60Hz 3.6A B al la st; 277Vac 5 0/ 60Hz 3.4A B al la st
5.8GHz ±7 5M Hz , ISM wave ba nd
<0.5mW
1.0W(s ta nd -b y)
39.4ft /1 2m M ax .
26.2ft /8 m
Sensor : 8S /3 0S /1min/5 mi n/ 10min/1 5m in /3 0min Remote c on tr ol : 8S /1min/5 mi n/ 15 min/3 0m in
Sensor : 0S /1 mi n/3min/ 5m in /10min/ 30 mi n/ + Remote C on tr ol : 0S /1min/5 mi n/ 30 min/+
Sensor : 10 %/ 20 %/30%/4 0% Remote C on tr ol : 10 %/20%/3 0% /4 0% /50%
Sensor: 5lux/15Lux/30Lux/50Lux/100lux/150lux/Disable Remote Control: 5lux/15Lux/50Lux/150lux/Disable
-35˚C~ 70 ˚C
IP20
Use 10-18 AWG c op pe r wi re only, bot h so li d an d st ra nd ed
MC612 V D RC
DETECTION PATTERN
Fast walk
100%
75%
50%
25%
6.6ft2m13.1f t4m19.7f t6m26.2f t8m32.8f t
10m
10m
(No te: Ple ase do no t set the d etect ion sen sitiv ity to 25 % when mo untin g at the he ight of 1 9.7ft /6m)
10m
(No te: Ple ase do no t set the d etect ion sen sitiv ity to 25 %/50% /75% wh en moun ting at t he heig ht of 26. 2ft/8 m)
6.6ft2m13.1f t4m19.7f t6m26.2f t8m32.8f t
Fast walk
75%
50%
6.6ft2m13.1f t4m19.7f t6m26.2f t8m32.8f t
6.6ft2m13.1f t4m19.7f t6m26.2f t8m32.8f t
Fast walk
6.6ft2m13.1f t4m19.7f t6m26.2f t8m32.8f t
6.6ft2m13.1f t4m19.7f t6m26.2f t8m32.8f t
10m
Mou nting h eight :9.8f t/3M
100%
10m
Mou nting h eight :19.7 ft/6M
10m
Mou nting h eight :26.2 ft/8M
Slow walk
100%
75%
50%
25%
6.6ft2m13.1f t4m19.7f t6m26.2f t8m32.8f t
10m
10m
10m
6.6ft2m13.1f t4m19.7f t6m26.2f t8m32.8f t
Slow walk
75%
50%
6.6ft2m13.1f t4m19.7f t6m26.2f t8m32.8f t
6.6ft2m13.1f t4m19.7f t6m26.2f t8m32.8f t
Slow walk
100%100%
6.6ft2m13.1f t4m19.7f t6m26.2f t8m32.8f t
6.6ft2m13.1f t4m19.7f t6m26.2f t8m32.8f t
10m
100%
10m
10m
SETTI NGS
Dete ct ion area, h old tim e an d dayli ght sen so r can be se t by usin g DI P switc hes on the s en sor. No te that r ed ucing t he dete ct ion are a wi ll also r ed uce the s ensit iv ity.
1, Det ec tion ar ea
I: up to 1 00 % II: up t o 75 % III: u p to 5 0% IV: up to 2 5%
2, Hol d ti me
Refe rs t o the tim e pe rio d th e lamp rema ins at 100% i ll umina ti on af te r no moti on i s det ec ted. I: 8s II: 30 s III: 1 mi n IV: 5mi n V: 10mi n VI:1 5m in VII: 30 min
3, Sta nd -by per io d Refe rs t o the tim e pe rio d th e lamp rema ins at a pre-se tt ing dim ming le ve l befor e it c omple tely swit ch es off in the l on g absen ce of peo pl e.
I: 0s II: 1m in III: 3 mi n IV: 5mi n V: 10mi n VI: 30 mi n VII: +
* When s et t o “+ ”mod e, t he lo w li ght is ma in taine d until m ot ion is de tecte d.
8S
4,St an d-by di mm ing l ev el
This i s th e pre-set ting di mm ing lev el you woul d li ke to hav e af ter t he h old tim e in the lo ng a bsenc e of p eop le . I: 10% II: 20 % III: 3 0% IV: 40%
40 %
5,Da yl ight se ns or
The se ns or can be s et t o onl y al low the l am p to illu mi nate be lo w a def in ed ambi en t bri gh tness thresh ol d. The se tting s ar e as foll ow s:
I: 5lu x, d arkne ss o per at ion onl y II: 15 lu x, dark ne ss op er ation o nl y III: 3 0l ux, twi li ght o pe ratio n IV: 50l ux , twili ght ope ra tion V: 100l ux , twili ght ope ra tion VI: 15 0l ux,tw il igh t op erati on VII: D is able *Whe n se t to Disa bl e, th e da yligh t se nso r wi ll swit ch o n the lam p when mo ti on is det ec ted regar dl ess of am bient l ig ht leve ls. *It sh ou ld be set t o Di sab le m ode if th e mo tio n se nsor is c on necte d to stan d- alone d ay lig ht s ensor s.
Remote Control Setting
NOTE1
Butt on
Name
Tran sm it
Detecti on A re a
Hold ti me
Dayli gh t Th re sh ol d
Stand -b y pe ri od
Stand -b y DI M le ve l
Auto mo de
ON-OFF
Reset
Ambient T hr es ho ld
Dim+ / Di m -
1/2/3 /4
Desc rip tion
Uploa ds t he s et ti ng s
25% /5 0% /7 5% /1 00 %
The t im eo ut f ro m 10 0% t o di m 8S/1m in /5 mi n/ 15 mi n/ 30 mi n
5Lux/ 15 Lu x/ 50 Lu x/ 15 0L ux / Di sa bl e
The t im eo ut f ro m di m to o ff 0S/1m in /5 mi n/ 30 mi n/ +
10% /2 0% /3 0% /4 0% /5 0%
A. Move me nt M ot io n de te ct 9 .8 ft ~1 9. 7f t/ 3- 6m B. Pr es en ce d et ec t 9. 8f t~ 19 .7 ft /3 -6 m C. Pres en ce d et ec t wi th d ay li gh t ha rv es ti ng 9 .8 ft ~1 9. 7f t/ 3- 6m D. Hi gh m ou nt in g: 1 9. 7f t~ 49 .2 ft /6 -1 5m E. Hi gh m ou nt in g wi th d ay li gh t ha rv es ti ng : 1 9. 7f t~ 49 .2 ft /6 -1 5m
Perma ne nt O N/ OF F
Press “Res et ” butto n fo r fa ctory t es ting purp os e only.
Detecti on
Are a
100 %
Pre ss t hi s bu tt on t o se t th e cu rr en t su it ab le dayli gh t th re sh ol d.
Adjust th e li gh t le ve l wh en m ot io n de te ct ed .
4 opt io na l qu ic k se tt in gs
Hold Time
1mi n
Day li gh t
senso r
Disab le
Stand -b y
period
3mi n 20%
Stand -b y dim lev el
Sensor mod ule
Metal fitt ing
Microwa ve de tec tio n inc lud es tw o par ts ca lle d mai n wav e and s ide w ave . Mai n wav e nor mal ly detects t he mo tio n sig nal . Sid e wav e doe s not e ffect motion detection but might disturb main
Side wave
Main wave
wave if the m icr owa ve mo tio n sen sor i s bui lt- in a se ale d met al lu min aire as microwa ve ca n not pass thro ugh m eta l.
When the mi cro wav e mod ule i s bui lt in to a me tal l igh tin g lum ina ire or installed in a sensor near a wall, the s ide w ave w ill b e ref lec ted b y the m eta l bas e or th e wal l. It c an di stu rb th e mai n wav e. As the resu lt of t his , the m icrowave motion senor might not perform optimally. Reducing the detecti on se nsi tiv ity o r the s ide w ave w ill h elp t o sol ve su ch pr obl ems .
FCC Warnning:
This e quipment h as be en tested an d found to com ply w ith the l imi ts for a Cl ass B d igital dev ice , pursuant t o part 15 of the F CC Rules.
Thes e limits are d esigned to p rovid e reasonab le protect ion a gainst har mfu l interfer ence in a residenti al in stallati on. T his equipm ent generates ,
uses a nd can radia te ra dio fre quency ene rg y and , if not in sta lled and use d in accorda nce with the i nst ructions , may cause ha rmf ul interfe rence
to rad io communi cat ion s. However, the re is no gu arantee th at in terferen ce will n ot oc cur in a pa rti cul ar install ati on. If th is eq uipment do es
caus e harmful in ter feren ce to r adio or t ele vis ion rec eption, wh ich c an be det erm ine d by turn ing t he equipme nt off an d on, the u ser i s
enco ura ged to tr y to co rrect t he interfe rence by one o r more of t he followi ng me asure s:
• R eor ient or relo cate the receivin g ant enna.
• I ncrease th e sep aration be twe en the eq uip men t and rec eiver.
• C onn ect the equi pme nt into an out let on a ci rcuit different fro m tha t to whic h the receiv er is connec ted .
• C ons ult the deal er or an exper ien ced radio/ TV te chnician f or he lp.
Caution:
Any ch anges or mod ific ations to th is device no t exp licitly ap proved by ma nuf acturer could voi d you r authorit y to operate t his e quipment .
This d evice comp lie s with part 15 o f the FCC R ule s. Operation is s ubject to th e following two c ondition s:
(1) Th is device ma y not cause ha rmf ul interfe rence.
(2) th is device mu st ac cept any int erferenc e recei ved , includin g int erferenc e that may cau se undesir ed operati on.
*Note 1 : MH 02 i s a co mm on u se d re mo te c on tr ol f or a v ar io us o f se ns or, MC612V D RC only wor ks u nd er M od e A. *Note 2 : 1/ 2/ 3/ 4: T he se 4 o pt io na l qu ic k se tt in g ar e fa ct or y de fa ul t se tt in gs , se e ta bl e ch ar t 1 below.
1. Fa ct or y de fa ul t se tt in gs : Accordi ng t o th e de fa ul t se tt in gs , sh or t pr es s 1/ 2/ 3/ 4, t he n pr es s to t ra ns mi t.
2. Mo di fi ca ti on : Short p re ss 1 /2 /3 /4 n um be r ke y, select your own sensor settings such as "Detection Range / Hold Time / Daylight Sensor / Stand-by Period / Stand-by Dimming Level" , then pre ss t o trans mi t.
3. Sa ve t he m od if ic at io n: After you h av e se t th e cu st om iz ed p ar am et er s, l on g pr es s th e nu me ri c ke ys 1 /2 /3 /4 n um be r key for m or e th an 3 s an d wi ll s av e th e cu rr en t se tt in gs t o th e 1/ 2/ 3/ 4 nu mb er k ey.
Qui ck
Setting
Detecti on
Are a
1
100 % 100%
2 3
100%
4
100% 5mi n
(Tab le c ha rt 1 : 1/ 2/ 3/ 4 Qu ic k Se tt in g fo r MC 61 2V D R C) 
Hold Time
8S 8S
1mi n
Dayligh t
sensor
Disable
5Lux 15L ux 50L ux
Sta nd -b y
perio d
1mi n 1mi n 10%
30m in 10%
Stand -b y dim lev el
0S
10% 10%
FAQ
Ques ti on
The loa d wi ll not illuminate
The load is permanently illuminated.
The loa d wi ll not illuminate despi te movemen t.
The rem ot e control i s no t working.
Incorre ct d ay li gh t
Caus e
sensor setting selected.
Load has failed .
Power is switch ed o ff . Continuous movement in the detection are a.
The lamp (containing sensor) is installed i n an a re a to o cl os e to ref le ct iv e su rf ac es , i. e. m et al , glass or concre te w al ls .
Speed o f mo ving obj ec t is n ot in the range of 0.5-3m/s or the detection radius is too small.
The battery on the re mo te control i s ru n ou t. The rem ot e co nt ro l is n ot aligned w it h sens or.
Adjus t se tt ing.
Replace l oa d.
Switch on.
Check d et ec ti on a re a se tt in g.
1, Make sur e in st al la ti on a re a suita bl e wi th a t le as t 30 cm s pa ce between l am p and su rr ou nd in g ref le ct iv e su rf ac es . 2, Re du ce sen si ti vi ty ( de te ct io n ar ea ).
Check d et ec ti on a re a se tt in g.
Chang e th e ba tt er y.
Chang e th e re mo te a ng le .
Reme dy
As the c on trol angl e of the In fr ared Re mo te Cont ro l is fixe d (30°) , if t he sens or s are insta lled to o cl ose to ea ch othe r, the se tting s of b oth sen sors wi ll be con fi gured. Pl ease refe r to the be lo w chart f or the di st ance of t he inst al latio n of e ach s en sor:
Mou nt in g he ig ht D is ta nc e be tw ee n ea ch s en so r
26.2 ft/8m
19.7 ft/6m
9.8f t/3m
8.2f t/2.5 m
Distance be tw ee n ea ch s en so r
Motion se ns or Motion se ns or
14ft /4.28 m
10.5 ft/3. 2m
5.2f t/1.6 m
4.3f t/1.3 2m
15°
15°
This e quipment c omp lie s with FC C rad iation exp osu re l imi ts set forth f or an uncontrolled env ironment .
This e quipment s hou ld be instal led a nd operate d wit h minim um di stance 20c m bet ween the rad iat or & your b ody.
ISED Statement
English: This device complies with Industry Canada license‐exempt RSS standard(s). Operation is subject to the following two
conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that
may cause undesired operation of the device. The digital apparatus complies with Canadian CAN ICES‐3 (B)/NMB‐3(B).
French: Le présentappareilestconforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitationestautorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareildoit accepter tout brouillageradioélectriquesubi, mêmesi le brouillageest susceptible d'encompromettre le
fonctionnement.
Radiation Exposure Statement
This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be
installed and operated with minimum distance 20cm between the radiator & your body.
Déclaration d'exposition aux radiations
Cet équipement est conforme Canada limites d'exposition aux radiations dans un environnement non contrôlé. Cet équipement doit
être installé et utilisé à distance minimum de 20cm entre le radiateur et votre corps.
Shenzhen Merrytek Technology Co..Ltd
No.3 Building, 380 Xiangshan Avenue, No.3 Industrial Park Luotian, Songgang Town, Bao’an District, Shenzhen 518105, Guangdong, China
www.merrytek.com Email:sales@merrytek.com
Loading...