561 Technical Information
JMB v 1.0 – 07-07-2000
Meridian 561 tape module diagnostic display.
When a tape module is fitted to a Meridian 561 an extra diagnostic display becomes available.
Three pieces of information are sent from the module to the main processor. These indicate;
1. The state of the stream presented to the main input.
2. The stream presented to the copy input.
3. The operating modes of the module.
E.g.
“0E/11/31”
Main input, stream type.
Main, operating mode;
Char. Emphasis? MHR
0 No No
1 No Yes
8 Yes No
9 Yes Yes
Main input, sample frequency;
3 = 96k data
4 = 88k data
5 = 48k data
6 = 44k data
7 = 32k data
B = 96k audio
C = 88k2 audio
D = 48k audio
E = 44k audio
F = 32k audio
Headphone mute,(additional to tape mute)
0 = mute, 1 = play
Tape input, stream status;
Tape, operating mode;
2 = analogue source
3 = digital audio source
4 = digital audio without SRC
5 = data marked stream
9 = mute
0 = SRC in bypass mode
(+ mute = 8)
1 = Route 1, audio only
(+ mute = 9)
2 = Route 2, audio only
(+ mute = A)
3 = Sample rate convert
(+ mute = B)
B = mute
(+ mute = A)
(+ mute = B)
(+ mute = C)
(+ mute = D)
Char. Content Lock? Emphasis?
0 Audio Yes Yes
1 Audio Yes No
2 Audio No Yes
3 Audio No No
4 Data Yes Yes
5 Data Yes No
6 Data No Yes
7 Data No No
Meridian Audio Limited, Stonehill, Stukeley Meadows, Huntingdon, Cambs PE29 6EX
Tel +44 1480 52144 Fax +44 1480 459934
http://www.meridian-audio.com/