The Meriam Process Technologies (Meriam) Model M1500
Digital Pressure Transmitter is a compact, NIST traceable,
precision measurement instrument available in a wide variety of
pressure ranges and communication / output options. Models
are available for differential, gauge, compound and absolute
pressure measurements. Output options include analog (420mA, 0-5V and two SPST switches) or digital (RS-232, RS485 or USB) models. Communication with digital M1500’s is
achieved using Meriam Serial Protocol (MSP), the Meriam DLL
or LabVIEW®. Digital units have an option of dual pressure
sensors in one unit (any non-differential pressure combination).
Personal computer (PC) configuration software is included. The
software can be used to configure digital transmitters for use
and is required to set up analog transmitter models.
Digital Pressure
Digital PressureDigital Pressure
Transmitter
Transmitter
Transmitter Transmitter
Manual
Manual Manual
1
Safety Information
Failure to follow all instructions could result in injury. Read, understand and follow all safety warnings
and instructions provided with this product. Also, meet or exceed your employer’s safety practices.
In no event shall Meriam be liable for any indirect, special, incidental, consequential or punitive damages or
for any lost profits arising out of or relating to any services provided by Meriam or its affiliates. It is not possible for
Meriam to identify all foreseeable uses/misuses, therefore all persons involved in commissioning, using or maintaining
this product must satisfy themselves that each intended application is acceptable.
Safety Warnings
The table below defines the safety symbols, signal words and corresponding safety messages used in the manual to
identify potential hazards and are intended to warn persons about hazards that could result in personal injury or
equipment damage.
This is the Read Instruction Manual symbol. This symbol indicates
that you must read the instruction manual.
This is the Safety Alert symbol. This symbol indicates a WARNING. Warnings alert you to actions that can cause personal
injury or pose a physical threat. Please read these carefully.
This is the Safety Glasses symbol. This symbol indicates that you must wear approved safety glasses during the task.
This is the Safety Gloves symbol. This symbol indicates that you must wear approved safety gloves during the task.
Indicates a potentially hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury.
Indicates information essential for proper product installation, operation or maintenance.
Information in this document is subject to change without notice. Check the Meriam web site (www.meriam.com) for latest
manual revision.
For customer assistance please call your local Meriam representative or Meriam directly.
Meriam Process Technologies
10920 Madison Avenue
Cleveland, Ohio 44102
Telephone: (216) 281-1100
Fax: (216) 281-0228
3
LabVIEW® is a registered trademark of National Instruments
Fire/Explosion Hazard. This instrument is not intrinsically safe. DO NOT use or service in areas
that may contain flammable gas or vapors, combustible dusts or ignitable fibers where an
unintended spark can cause a fire/explosion.
Do not exceed the Pressure Limits listed in the Specifications section of this manual. Failure to
operate within the specified pressure limit could result in death or serious injury.
Do not exceed the Maximum Input Voltage listed under “Power Requirements” in the Specification section of this
manual
For Analog output units, do not exceed the Switch Rating listed under “Analog Outputs” in the Specifications
section of this manual.
Disconnect power before servicing.
Substitution of components may impair operation and safety.
Do not connect to AC power; use only with DC supply.
June 2012
1
Introduction
Introduction
IntroductionIntroduction
Congratulations! The M1500 is one of the most capable pressure transmitters available. Follow the instructions in this
User’s Manual to set up the M1500 to perform to its full potential. Thank you for choosing Meriam.
Pressure
Pressure Sensor Code and
Pressure Pressure
Sensor Code and Range
Sensor Code and Sensor Code and
Range Table
RangeRange
Table
Table Table
Model No. M1500-“Sensor Code with Range” 1 shown below:
Sensor
Code 3
DNxxxx
DIxxxx
GIxxxx
CIxxxx
AIxxxx
Notes:
1
Dual Pressure Sensor Units (digital communications option only)
M1500-“Sensor Code with Range”-“Sensor Code with Range”
Any combination of G
2
DI Pressure Manifold Options
2-port DIxxxx manifolds are standard; use for clean liquid service only
4-port DIxxxx flushing manifolds are order options; best for dirty liquids, congealing liquids, and liquids with particulates or suspended
3
Media Compatibility
Model Number Examples:
solids
Non-isolated DN sensors: clean, dry, non-corrosive, non-condensing gases only
Isolated DI sensors: any media compatible with 316SS & Viton®
Isolated G
Each M1500 comes with a product CD ROM that includes the following resources:
- Meriam Setup Utility
- Meriam Serial Protocol (MSP) Implementation Guide
- USB Drivers
- LabVIEW® Drivers (VIs)
Please make use of these resources as referenced in this manual.
Meriam Setup Utility
Meriam Setup Utility
Meriam Setup UtilityMeriam Setup Utility
The M1500 Meriam Setup Utility runs on Microsoft Windows® XP, Windows® Vista and Windows® 7 operating
systems. Place the CD in the PC’s CD ROM drive and install the software using the installation utility. The software is
used to configure M1500 Digital Transmitters by setting engineering units, damp rate and other parameters, to zero
the unit, or to set the output span on analog units. See the “PC Interface” section of this manual for information on
connecting the M1500 to a host PC.
Resources
ResourcesResources
The Software user interface provides the following user selections:
1.) Startup
2.) Measurement and Configuration
3.) Set Analog Output
4.) Transmitter Information
5.) Reflash Firmware
6.) Field Recalibration
The Software provides user instruction and / or drop down selection boxes once the desired option is selected. See
the Software’s HELP feature for more details.
PC
PC / M1500
/ M1500 Interface
PC PC
/ M1500 / M1500
For
For Analog Output
Analog Output Configuration
For For
Analog Output Analog Output
To configure an M1500 with analog output, connect the unit to a host PC using a USB type A to USB type mini-B
cable as shown in the diagram below. The USB connection will power the M1500 and provide communication for
configuration setup when connected to high power (500 mA) USB ports or powered USB hubs. Open the M1500
Meriam Setup Utility application to configure the transmitter as desired. See the “Installation and Operation” section of
this manual for additional information.
Interface
InterfaceInterface
Configuration
ConfigurationConfiguration
3
For
Panel Mounting Template for 2 Port Manifold
For Digital
Digital Communication
For For
Digital Digital
Communication M1500s
CommunicationCommunication
M1500s
M1500s M1500s
Connect the M1500 to a host PC, using the RS-232, RS-485 or USB connections provided. See the “Digital Wiring
Diagrams” section of this manual for more details. Use the M1500 Meriam Setup Utility to configure the transmitter or
use MSP commands (see protocol documentation on the product CD or at www.meriam.com under Resources /
Application Notes). The M1500 pressure default network address is 40 (0x28 Hex) and module address is 64 (0x40
Hex) for MSP and LabVIEW®. See the “Installation and Operation” section of this manual for additional information.
USB drivers must be installed on the host PC prior to communication with M1500 USB models. Find these drivers on
the product CD.
Interface Accessories
Interface Accessories
Interface AccessoriesInterface Accessories
The following table lists part numbers for various accessories available to assist in configuration or communication.
Part Number Description Accessory Status
Z9A000003PN06M1500 Product CD ROM Standard, all models
Z9P273
Z7621-1
Z7621
ZA900447-00052
Z9R111
USB type A to USB type mini-B cable–
used with analog output M1500s to
interface with PC & configuration software
RS-232 to RS-485 Converter, PC Mount,
port powered
RS-232 to RS-485 Converter, DIN rail
mount, externally powered
DB-9 Cable, male x female – optional
accessory
Meriam Serial Protocol Implementation
Guide
Optional for analog
models, initial set up
& support
Optional for RS-485
models initial set up
& support
Optional for RS-485
multi-drop networks
Option for RS-232
and RS-485 support
On CD and available
at www.meriam.com
Mounting Options
Mounting Options
Mounting OptionsMounting Options
M1500 mounting options include panel and DIN rail mount. Both are standard on all models and hardware is included
with shipment.
Panel mounting is achieved using the cut out and mounting hole guides below. Plan the mounting hole locations so
the P1 (HI) and P2 (LO) ports will be in the desired position upon completion. The four Port Manifold template is only
used for M1500-DIxxxx models with optional flushing ports.
4
Panel Mounting Template for 4 Port Manifold
(M1500-DIxxxx with optional flushing ports)
Once the panel cut out is made and the mounting holes are drilled, remove the corresponding set of diagonal screws
from the M1500 pressure manifold. Insert the M1500’s pressure manifold through the rear of the panel cut out. Locate
the longer panel mounting screws supplied with the M1500, install them through the panel holes, and thread them into
the vacated holes in M1500 pressure manifold. Tighten as needed. A completed panel mount is shown below.
The factory installed DIN rail clip may be removed from the M1500 enclosure if desired for panel
installation. Use a Phillips head screw driver to remove the mounting screw and clip. Reinstall the
screw to prevent debris from entering the enclosure.
DIN rail mounting is accomplished using
the factory-installed DIN clip located on
the edge of the M1500 enclosure. DIN
rail mounting is excellent for mounting
several M1500s in close proximity to one
another, either inside a protective
enclosure, or on a convenient mounting
surface or wall. For high vibration
applications use the longer panel mount
screw to secure enclosure to DIN rail.
5