Mercury Row MCRW6234 Assembling & Installation Instructions

ASSEMBLING & INSTALLATION INSTRUCTIONS
The drawing shown may not exactly match the product enclosed.
However, the installation instructions do apply to this product.
WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER. ATTENTION! COUPER LE COURANT AU FUSIBLE OU UN DISJ ON CTEUR.
ASSEMBLING THE FIXTURE (Fig.1)
1. Shut off the power at the circuit breaker and remove old fixture,
2. Attach the mounting screw part way into the side hole of the crook
3. Follow wiring instructions carefully (see fig.2).
4. Attach the back plate(A) onto the junction box, aligning screws on
5. Install the light bulbs(Not included) in accordance with the fixture’s
6. With silicone caulking compound, caulk completely around
7. Raise the shade(C) onto the back plate(A), aligning the shade’s hole
CONNECTING THE WIRES (Fig.2)
1. Connect the electrical wires as follows. Connect the Black wire from the fixture to the black house (hot) Wire. Connect the white wire from the fixture to the white (neutral) house wire. Make sure all wire nuts are secured. You may wrap the connections with electrical tape. If your outlet box has a ground wires (green or bare copper) connect fixture’s ground wire to it. Otherwise attach the bare copper fixture wire to the green ground screw on the crossbar.
2. Tuck the wire connections neatly into the wall junction box.
including the single bar. Carefully unpack your new fixture and lay out all the parts on a clear area. Take care not to lose any small parts necessary for installation.
cross bar, then lock it securely with hex nut. Attach the cross bar to the junction box using two box screws as shown. The side of the cross bar marked “GND” must face out. The junction box is not
included.
cross bar with mounting holes and lock it securely with the ball nuts(D).
specifications. NOTE: DO NOT EXCEED THE MAXIMUM
WATTAGE RATING! where back of cover meets with the wall surface to prevent
water from seeping into junction box.
with the side screw hole of the back plate(A), then lock it securely with mounting screw(B).
Your installation is now complete. Return power to the junction box and test the fixture.
FIG.1
Supply
GroundWire
FIG.2
©COYRIGHT ALL RIGHTS RESERVED.
FIXTURE WIRES Black or Smooth
HOUSE WIRES Black(Hot)
Thank you for purchasing our product.
Need assistance with parts or assembly? Please call customer service
FIXTURE WIRES White or Ribbed
HOUSE
WIRES White
(Neutral)
D
FIXTURE WIRES Bare Copper (Ground)
HOUSE
Green or Bare
Copper(Ground)
WIRES
Loading...