Mercury Marine 892486K01 User Manual

892486K01
ANALOG
GAUGE
SMARTCRAFT
Analog Gauge
NOTE:
gauges. sender System system can support
IMPORTANT: Mount
prevent
secure all wires and harnesses away from hot or moving
1. With
2.
lnterface
This
Throttle and
For
inputs on
Link
moisture from
screws and
dash or helm in close
Refer connections. Tape back any unused terminals. Secure connections
man ufactu rers specifications.
to the
INTERFACE
Analog Gauge lntefface
(Dfq
Shift
analog
gauges,
gauges,
gauge
use 3
/0
System
AGI
collecting at base
washers
following
backs, and tape
Installation
system
use ring terminals on
pin
module with
proximity
table for
to drive analog and/or
System
gauges per
Link
supplied
to
AGI harness wire
(AGI)
(AG|
gauges
can only be
AGI harness
any unused terminals. For
back
Link
connection on
helm, 2 helms maximum.
wires
coming out of
of wires
in
kit, mount the AGI module securely under
and
being used.
used with
SmartCraft
the
to connect to analog
AGI harness. The AGI
potting
wicking into module.
parts.
color/analog
facing downward to
gauge
14
pin
Digital
System Link
SmartCraft
Route and
sender input
per
gauge
Analog Gauge
Tachometer
Pressure/Oil Level
Oil
Water Temperature
Trim Positions BrownAtVhite
Fuel Level Pink/Black
-
AGI module
a
pin
-
b
Route
3.
gauges. Route
4.
connections
14
- AGI harness
c
and
Secure
and connect
connection
connect
per gauge
Type
wire
from key switched 12 volt
connections
ground
manufacturers
per
gauge
wire from
d
*
-
f
manufacturers specifications.
analog
specifications.
gauges
Harness
AGI
Gray
Blue
Tan
-
Analog
-
System Link 3
10
gauge
pin
CAN
positive power
to a common
Wire Color
terminal connections
pin
data connection
)o
connection
source to analog
ground.
Secure
90-893357
APRIL 2004 Printed in
U.S.A.
-@2004,
Mercury Marine
Pagell4
ANALOG
GAUGE
INTERFACE
(AGI)
5.
Connect any SmartCraft System Link
AGI system can
6.
7.
14
Plug
Connect 10
harness.
AGI
lf
a.
connection on AGI
command module harness.
lf
b.
SmartCraft System
will
harness, 10 of harness harness into
ports
pin
SmartCraft System View
be
support 10
AGI harness
pin
CAN
connection
data harness connection on command module harness to
required. Plug 10
pin
CAN data
adaptor into
other end of harness adaptor.
junction
on
box
System
harness
View
junction
with weather
gauges
gauges
Link
into
AGI
is not
directly
is being used,
pin
CAN data
connection
box. Plug 10
being used, into 10
on System
caps.
pin
3
to
module.
System
per
helm, 2 helms maximum.
plug
pin
CAN
junction
a
connection on
pin
lnsulate any unused
box
View
CAN data connection on
Link
connection.
pin
10
data
and
command
harness, and one
CAN data
connection on
harness adaptor
module
connection
The
end
AGI
Page2l4 90-893357
ANALOG
GAUGE
TNTERFACE
(AGr)
Typical
AGI
Application
with
System
View
{
-t
__l
I
I
I
I
I
I
Configuring
90-893357
a - System
-
10
b
System
-
SmartCraft Junction
c
-
Weather Cap
d
Analog/Digital
IMPORTANT: factory default tachometer.
have
may
Depending on the desired use of analog/digital
to be
View display
pin
data connection on
CAN
View harness
Box
Tachometer
The
engine
has
been set to an analog. This
configured from
Propulsion
analog
Control
to
Following are optional uses of analog
tachometer configuration
Analog Tachometer Only
in the PCM necessary to run them.
Gauge
Configuration
-
Harness Adaptor
e
pin
-
f
10
CAN data connection on
AGI harness
g -
AGI module
pin
10
h -
Command
CAN data connection on
Signal through
Module
a digital.
digital
and
will
(PCM)
allow the
gauges
Module
harness
PCM
tachometer configuration
operation of
gauges,
and the setting
one analog
PCM
the
set-up
for
Analog Digital
X
Page3l4
the
ANALOG
GAUGE
TNTERFACE
(AGt)
PCM
System
System System
Harness and Command Module Harness without
View, AGI used
Tachometer, to run analog and
The Digital
to select analog or digital
Configuration
IMPORTANT:
configuration.
1. Attach DDT
2. Press
Press 1.
3.
4. Press
5. Arrow down and
Arrow down
6.
7. "CONFIGURE TACH
8. "TACH
9. After task
Link
Gauges used
Tach
Link Gauges used in
System
Monitor or System Tach
with
without
or
Diagnostic Tool
with DDT
The
use of DDT cartridge 1.3.1 or above
to engine
"MERCURY
1.
"TO
CONTINUE"
"MANUAL
2.
LINK
completion
and
CONFIG"
TEST" Press Press
Gauge
Configuration
with
System
conjunction
View,
with
System
Monitor,
System Link Adaptor
the use of
System View, System Monitor or
System
(DDT)
PCM
tachometer configuration.
power
and
Link
Gauges
or Computer Diagnostic
Refer
up.
to DDT Owners Manual if needed.
MARINE"
5. "SPECIAL FUNCTION"
9. "TACH LINK
SOFTWARE
-
Press 1.
CONFIG"
DRIVER?"
"FOR
LINK"
-
Press 1. "YES"
(Digital)
confirmation, Press "MODE" to Exit
Analog Digital
or
System
System
System
(CDS)
can be
must be used for PCM
-
Press 2. "FOR ANALOG"
X
X
used
PCM
Configuration
Products
W6250 Pioneer Road
Fond
of
Lac, Wl 54936-1939
du
with
CDS
1:
Attach
2. From Logon screen, navigate
3. From
CDS
Engine
to engine.
Refer
to on-line help if needed.
Engine
to
Select screen fill in engine
4. From Tool Box screen, select Active Diagnostics.
5.
From
Diagnostics
screen,
scroll down
Active
6. To change PCM configuration from default
then select Run,
7. To change PCM configuration from digital
Run.
Mercury
Marine
lllercury, Mercury Marine, lvercury Propelleß, Mariner, K-Planes, Mercathode, logo,
and Smartcraft logo are all registered trademarks
Proteclion
logo is a registered
Select screen.
type
information
and select
Tool
and select Tach Link Config.
of analog to digital, select Enable and
to analog,
MerCruiser,
Quicksilver,
Ridecuide,
Seruice
Smartcraft, Zero
mark of Brunswick
select
lvlercury Mercruiser,
The
#1 On
Water, Alpha, BEvo, Pro Max,
Effort,
Corporation.
Disable and then select
Mercury Racing, Mercury Precision Parts,
lV with Waves logo, lvlercury with Waves
Brunswick
of
Corporation. l,.4ercury Product
Box.
OptiMax, Sport-Jet,
Page4l4
90-893357
Loading...