Mercury V-8252 User Manual

V-8252
Vacuum cleaners
Please read and keep these instructions
Important safety instructions
The use of any electrical appliance requires the following common sense safety rules.
Primarily there is danger of injury or death and secondly the danger of damage to the
appliance. These are indicated in the text by the following two conventions:
Warning: Danger to the person!
IMPORTANT: Damage to the appliance! In addition we offer the following safety advice.
Location
Do not use or keep this product outside when it is raining.
Do not store the appliance near hot ovens or heating appliances.
Mains lead
Do not allow the mains lead to become strained or run this appliance over it.
If the electrical cable becomes damaged, the complete cable assembly must be
replaced. Do not attempt this task yourself. Contact the local retailers.
Children
Children do not understand the dangers associated with operating electrical appliances.
Never allow children to use this appliance.
Personal safety
The plug must be removed from the wall socket before cleaning or maintaining the
appliance.
Never modify the cleaner in any way.
Never use in the presence of explosive liquids or vapors.
Never pick up inflammable or poisonous liquids such as petrol, copier toner or other
volatile substances. Never pick up acids, asbestos or asbestos dust.
Repairs to electrical appliances are only to be undertaken by trained personnel.
Unprofessional repairs can be dangerous for users.
The appliance must never be left running when unsupervised.
Product safety
Never use the appliance without the filters being installed.
Never use the appliance to vacuum hot ashes, broken glass, sharp objects or liquids.
To protect against fire, electric shock and personal injury do not immerse cord, plug or
cleaner in water or other liquid.
Electrical requirements
Check that the voltage on the rating plate corresponds with your house electricity supply
which must be A.C (alternating current)
If the socket outlets in your home are not suitable for the plug supplied with this appliance
the plug should be removed and the appropriate one fitted.
If you cut off the plug and let go of the cable it will rewind into the machine.
Therefore you must pull out a length of the cable and secure it before cutting off the plug
and refitting a new one.
IMPORTANT: The plug removed from the mains lead. If severed, must be destroyed
as a plug with a bared flexible cord is hazardous if engaged into a live socket outlet.
ILLUSTRATION
Features
1. On/off switch button
2. Variant Speed Knob
3. Cord Rewind Button
4. Hose-connector
5. Front cover lock
6. Hose
7. Air regulation button
8. telescopic-tube-35
9. Floor Brush
10. Air Outlet plate
11. Tube storage clip
12. Multipurpose nozzles (2 in 1 crevice nozzle & upholstery nozzle)
Quick start
1. Assemble the nozzle, the tube and hose.
2. Pull out the mains cable to its full length and plug into the mains supply.
3. Switch on by pressing the On/off switch-button 1.
Accessories
Insert the hose
Fit the hose 6 to the cleaner by inserting the hose end into the Hose-connector 4 until it
clicks to the position.
TO remove the hose
When removing, squeeze the clips both side and pull.
Fitting the tubes and accessories
1. Attach the tube to the handle end of the hose. The hose handle features an air regulation button 7 which allows suction to be
reduced as required.
2. Attach the floor brush 9 to the tube.
3. Attach the multipurpose nozzle 12to the tube.
Turn the rotating nozzle as the arrowhead show; it can be used as the upholstery nozzle
(for curtains and upholstery).
Turn the rotating nozzle backwards to the home position; it can be used as the crevice
nozzle (for awkward places, behind radiator; or for hard surfaces, pelmets, delicate
objects etc).
Controls
Power
The on/off control is operated by On/off switch-button. 1
Variable power
Variant Speed Knob 2varies the suction power as required .For example, maximum
suction can be used for cleaning carpets, hard floors etc, and reduced suction for cleaning
upholstery and curtains. Suction can also be controlled using the airflow regulator 6 on the handle .Closed for
maximum suction, open for reduced suction.
Automatic cable rewind
After use, unplug and press the Cord Rewind Button 3 to retract the cable.
WARNING: When using the cable rewind, always hold the plug as the cable will rewind
quickly.
Dust disposal
The indicator is red when the dust is full, please clean the dust bag or replace it in time. Take out the hose connector. Press the front cover lock 5 to open the front cover and take
out the dustbag.A
Replace the dustbag
If paper dustbag is adopted. Please throw away and replace new one.
If textile filter is adopted, take down the dust bag, throw off the dust and fix it again.
Installing the dustbag
Insert the bag collar into the grooves of dustbag support.B
Cleaning the HEPA filter
To maintain the suction of the cleaner, the HEPA filter must be washed regularly.
1. Remove air outlet Plate10 before removing HEPA filter.
2. Remove the HEPA filter with the filter grille.
3. Use a soft brush to remove dirt from the HEPA filter.
4. Resemble the HEPA filter back to the place.
5. Then replace the air outlet cover onto the main body.
IMPORTANT: Do not use detergents to clean the filter. The HEPA filter must be thoroughly
dry before the machine is used.
Storage position
When finished you can store the tube by locating the tube storage clip11 into the slot on
the back of the cleaner as shown. C
Care and maintenance
Your cleaner is manufactured to withstand normal day-to- day use, but an occasional wipe
over with a damp cloth will help maintain its good looks.
Loading...