Mercoid FBLT Operating Manual

B
REATHER TUBE
SUBMERSIBLE CABLE
Ø
1-3/16
[
Ø30.16]
5-15/16
[150.83]
Ø
5/8
[
Ø15.87]
RECEIVER
PRESSURE
TRANSMITTER
RED
BLACK
SHIELD
POWER SUPPLY
10-33 VDC
FBLT
S
UBMERSIBLE
C
ABLE
B
REATHER TUBE
Ø
1-3/16
[
Ø30.16]
5
-15/16
[
150.83] 1
-7/8
[
47.63]
1/2˝ NPT
1
/2
[
12.69] 1
5/16 HEX
Ø5/8
[Ø15.87]
1-1/8
[29.33]
Bulletin L-FBLT
Series FBLT Submersible Level Transmitter
Specifications - Installation and Operating Instructions
FBLT with NPT Option
The Series FBLT Submersible Level Transmitter is designed with a
flush diaphragm tip that will not clog in harsh applications such as sewage lift stations. Narrow body design allows the FBLT to fit into stilling wells and narrow installations. The FBLT features a robust FKM fluoroelastomer diaphragm that is PTFE coated for a stick resistant surface that will hold up in aggressive fluids. The diaphragm cavity is filled with a gel that will not leak out versus oil or grease that our competitors use. Body is constructed of 316 SS and the cable is either polyurethane or ETFE for more corrosive applications.
The FBLT incorporates lighting and surge protection (not guaranteed or covered by warrantee) to stand up in harsh applications. Optional NPT connection allows the unit to be rigidly installed in a pipe/conduit, or to attach our A-625 hanging loop for attaching a chain for pulling out of the installation.
Applications
Sewage lift stations, industrial slurries, industrial sumps, landfill leachate, reservoirs, sludge pits, oil tanks, etc.
FBLT with NPT Option
SPECIFICATIONS Service: Compatible liquids. Wetted Materials:
Body: 316 SS; Cable: Polyether polyurethane or ETFE; Diaphragm: PTFE coated FKM fluoroelastomer; Label: Polyethylene polyamid.
Accuracy: ±0.25% FS (absolute). Temperature Limits: -4 to 176°F (-20 to 80°C). Compensated Temperature Limits: 32 to 140°F (0 to 60°C). Thermal Effect: ±0.0075%/°F (±0.0135%/°C). Pressure Limit: 2x range. Power Requirements: 10 to 33 VDC. Output Signal: 4 to 20 mA DC 2-wire. Response Time: < 50 ms. Max Loop Resistance: 1000 Ω @ 30 VDC. Electrical Connections: Wire pigtail. Mounting Connection: Suspended below point being monitored. Electrical Protection: Surge/lightning protected per EN61000-4-5,
Class 5.
Weight:
Body: 0.3 lb (0.136 kg); Cable: 0.037 lb (0.009 kg) per foot.
Agency Approval: CE.
ELECTRICAL INSTALLATION
An external power supply delivering 10 to 33 VDC with minimum current capability of 40 mA DC (per transmitter) is required to power the control loop. See figure below for connection of the power supply, transmitter and receiver. 
The maximum receiver load resistance (RLmax) for the DC power supply voltage (Vsup) is expressed by the formula:
RLmax = Vsup – 10V
0.02A
Shielded cable is recommended for control loop wiring.
MERCOID DIVISION
DWYER INSTRUMENTS, INC. P.O. BOX 258 • MICHIGAN CITY, IN 46360 U.S.A.
Phone: 219/879-8000 www.dwyer-inst.com Fax: 219/872-9057 e-mail: info@dwyer-inst.com
WARNING:
A voltage potential between the ground wire of the unit and the ground of other equipment can lead to electrolytic corrosion. Always ensure the grounding system provides an equipotential between the transmitter and the earthing ground connection. Avoid using the power system protective ground since this will often have a significant potential difference to the transmitter ground. Also note that dissimiliar metals in the ground system may cause electrolysis corrosion of the transmitter or other components in the ground system.
During installation, connect a voltmeter or ammeter between the shield ground wire and the grounding connection. If there is a measurable voltage or current electrolytic corrosion may be a serious possibility. If there is a potential difference then some isolation system will be required. Improper grounding may lead to damage or poor signal integrity.
Model Number Guide
22S
Example Construction Circuit Options Body Material Accuracy Output Reference Cable Material Range Unit
Range Value Cable Length Options
Note: With NPT option only, tighten connection with wrench on top 15/16 hex, not
the nut.
FBLT
FBLT
C
S
C
IIVVP
F
P E
F M P
30X50XNIST
FBLT-2SC-IVPF-30-50-NIST
Flush Tip Surge protected
316 SS
0.25% 4 to 20 mA Vented Polyether polyurethane ETFE Feet of water column Meter of water column PSI
In feet for feet and psi range, in meters for meter range NIST Traceable Certificate
NIST
1/2˝ NPT mounting option
NPT
MAINTENANCE/REPAIR
Upon final installation of the Series FBLT, no routine maintenance is required. The Series FBLT is not field serviceable and should be returned if repair is needed (field repair should not be attempted and may void warranty).
WARRANTY/RETURN
Refer to “Terms and Conditions of Sales” in our catalog and on our website. Contact customer service to receive a Return Goods Authorization number before shipping the product back for repair. Be sure to include a brief description of the problem plus any additional application notes.
©Copyright 2013 Dwyer Instruments, Inc. Printed in U.S.A.12/13 FR# M2-443891-10 Rev.1
MERCOID DIVISION
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000 www.dwyer-inst.com Fax: 219/872-9057 e-mail: info@dwyer-inst.com
P.O. BOX 258 • MICHIGAN CITY, IN 46360 U.S.A.
Loading...