BEFORE INSTALLATION
NOTE: Upon receipt of this unit, immediately unpack and inspect for possible concealed damage. If the unit is found to be
damaged, save all packing materials and contact the delivering carrier within 5 days. Refer to “Shipping Damag e Instructions”
enclosed with the unit for detailed instructions. Failure to follow these instructions will negate Merco Savory’s or your ability to
file claims and receive compensation for shipping damages.
INSTALLATION INSTRUCTIONS
Install this unit in the most convenient location for ease of cleaning, maintenance and general operation. Avoid installing with
drafts, close proximity to grease or vapor-producing appliances, or other high ambient heat equi pment. Allow sufficient
clearance on sides and back of unit for proper air circulation. Allow sufficient overhead clearance for easy access to the water
reservoir opening. The DHC should be placed on a firm even surface capable of holding 120 pounds (55 kg.).
ELECTRICAL SPECIFICATIONS
Domestic DHC 24H
Domestic DHC 24
Internaitonal
International DHC 24-CE
Item # Description Voltage Hz. Watts Amps Cord/Plug Dimensions
DHC 24HCE
Display Hold
Cabinet w/hum
Display Hold
Cabinet w/o hum
Display Hold
Cabinet w/ hum
Display Hold
Cabinet w/o hum
120 VAC 60 1500 12.5 6’, NEMA 5-15P 24” W x 36” H x 24” D
120 VAC 60 1175 9.8 6’, NEMA 5-15P 24” W x 36” H x 24” D
230 VAC 50 1500 7 2 M, CEE 7/7
230VAC 50 1175 5.5 2 M, CEE 7/7
610mm W x 915mm H
x 610mm D
610mm W x 915mm H
x 610mm D
OPERATION
• The DHC is designed to display and hold up to 4 – 18” pizzas for one hour.
• Set Main Power switch to the “ON” position.
• Pre-heat the unit for 20 minutes.
• Set the temperature control at desired temperature for your product. Factory recommendations are setting 6 on the
temperature dial (175° F, 80° C). The temperature range is 125° F (52° C) to 205° F (96° C).
• The red “Add Water” light will illuminate when water is needed. Fill the water tank with distilled water in prepar ation to start the
humidity cycle. The water tank will hold 1 gallon (3.75 liters) of water. Be careful not to overfill. An audible alarm will sound
prior to overfilling of the tank. If the alarm is heard the operator is to cease filling the water tank.
• Set humidity. Factory recommendations are setting to “medium.”
• Open the access door(s) and load the product onto the shelves of the rotating rack. The rack will stop rotating when the
door(s) are opened.
• The DHC will keep your product hot and fresh for serving. The digital display will monitor the cabinet temperature. The alarm
will sound when the tank needs to be refilled.
CONTROL PANEL FEATURES
Main Power On/Off Switch – This switch controls power to the unit.
Temperature Display – Shows cabinet temperature in °F or °C.
Heat Control – This control regulates the cabinet temperature. The settings range from low to high.
Humidity Control – This control regulates the amount of cabinet humidity. The settings range from low to high.
Heat / On Light – This green light illuminates when the heat control is energized.
Add Water Light – This red light illuminates when additional water is required.
CHANGING MERCHANDISING DISPLAY PANELS
The merchandising panels supplied by Merco Savory are easily changed by removing the four (4) mounting screws located on
the top and back side of the unit (2 on each side).
WATER RESERVOIR FILLING INSTRUCTIONS
INITIAL FILLING
IMPORTANT: To prevent excess mineral build-up, which could affect the operation of this unit, only use low mineral or distilled
water. Service required due to excessive mineral build-up WILL NOT be covered under warranty.
1. Set main power switch to the “ON” position.
2. Open the water reservoir cover (located on the left side of the control panel). Using a measuring cup, start filling the tank.
2
DHC Ops Manual