INSTALLATION & OPERATION MANUAL for CG-30 Gas
Vertical Conveyor Toaster
The Savory Model CG-30 is a gasfired conveyor toaster capable of
toasting breads, buns, bagels,
English muffins, frozen waffles
and more with unsurpassed
speed and quality. These toasters operate efficiently on the
combustion of natural or propane
gas. Standard features on both
models include front and rear
delivery, and the ability to toast
one or both sides of a product.
NOTE: This manual contains
important safety, installation and
operation instructions. Require
all operators to read this manual
before using the unit. Failure to
follow the instructions contained
in this manual may cause injury,
damage to the unit, and will void
the warranty.
Toaster installation should be carried out by a SAVORY Qualified Service Representative and must conform with local
codes, or in the absence of local codes, with the “National Fuel Gas Code” ANSI Z223.1, Natural Gas Installation Code
CAN/CGA-B149.1, or the Propane Installation Code, CAN/CGA-B149.2 as applicable, and National Fire Protection Association Standard 96, “Removal of Smoke and Grease Laden Vapors from Commercial Cooking Equipment”. The term
Qualified Service Representative means any individual, firm, corporation or company which either is engaged in or is
responsible for the installation or replacement of gas piping on the outlet side of the meter or the service regulation when a
meter is not provided or the connection, installation or repair of gas appliances, who is experienced in such work, familiar
with all precautions required of the authority having jurisdiction.
THIS MANUAL SHOULD BE RETAINED FOR FUTURE USE
0101-JDM 07018
BEFORE INSTALLATION
NOTE: Upon receipt of this unit, immediately unpack and inspect for possible concealed
shipping damage. If unit is found to be damaged, save all packing materials and contact your
delivery carrier within 5 days. Refer to “Shipping Damage Instructions” enclosed for detailed
instructions. Failure to follow these instructions will negate Merco/Savory’s or your ability to
file claims and receive compensation for shipping damage.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
NOTE: Instructions to be followed in the event
the operator smells gas, should be posted in a
prominent location. This information can be
obtained by consulting your local gas supplier.
WARNING: Improper installation, adjustment, alteration
service or maintenance can cause property damage, injury or
death. Read the Installation & Operation and Maintenance
instructions thoroughly before installation or servicing this
equipment.
INSTALLATION INSTRUCTIONS
Install the CG-30 toaster in the most convenient location for ease of cleaning, maintenance and general operation. Avoid
installing in locations with drafts, close proximity to grease or vapor-producing appliances or other high ambient heat
equipment. For cafeteria or waiter type operation, the toaster should be set for rear delivery, with the receiving tray facing
the traffic flow. Front Delivery: Insert delivery chute through front opening with lipped end held. Push delivery chute rear
up and back until notches fall over chute pins. Rear Delivery: Insert delivery chute through rear opening with lipped end
held. Push delivery chute rear up and back until notches fall over chute pins.
Electrical Grounding Instructions: This appliance is equipped with a three-prong (grounding plug) for your protection
against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or
remove the grounding prong from this plug.
IMPORTANT
Toaster should be installed in an area free and clear of combustibles. The area should have no obstructions
to the flow of combustion and ventilation air. Provisions should be made for adequate air supply in the room
where the toaster is installed. Maintain adequate clearance for air openings into the combustion chamber.
MINIMUM CLEARANCE FROM COMBUSTIBLE AND NONCOMBUSTIBLE
CONSTRUCTION IS 6” FROM EACH SIDE AND 6” FROM REAR OF UNIT.
SUITABLE FOR INSTALLATION ON COMBUSTIBLE FLOORS.
A gas pressure regulator is provided for use with both natural gas and propane gas. It is recommended that a flexible
metal connector be installed between the toaster and the gas supply line. The connector should comply with the latest
edition of the Standard for Connectors for Moveable Gas Appliance ANSI Z21.69 and that adequate means must be
provided to limit the movement of the unit without depending on the connector and any quick disconnect device or its
associated piping to limit the unit movement. The connector should be of the appropriate length and equipped with a quick
disconnect coupling containing a feasible link (Savory Part #25209). This will permit portability for ease of cleaning, adjustments and service. Minimum inlet pressure for natural gas is 5” w.c. Minimum inlet pressure for propane gas is 11” w.c.
Electrical grounding of the installed toaster is required. The CG-30 toaster is factory supplied with a 6’ cord and NEMA515P plug. Electrical power required to operate the conveyor motor and the burner control valves is only 40.2 watts which is
readily available at most electrical outlets. This toaster must be electrically grounded in accordance with local codes, or in
the absence of local codes, with the latest edition of the National Electrical Code ANSI/NFPA 70 or the CSA C-22.2.
NOTE: Wiring diagram is permanently attached to the inner surface of the removable right side panel.
2