UNIT SPECIFICATIONS
Unit # Volts Amps Watts Hz Phase Cord/Plug Weight
16001* 208 11.25 2340 60 Single 6’ NEMA 6-20P 47 lbs. / 21.3 kg.
16003** 230 9.91 2280 50 Single CEE 7/7 47 lbs. / 21.3 kg.
16005 208 11.25 2340 60 Single 6’ NEMA 6-20P 47 lbs. / 21.3 kg.
* 50% Stand-by Energy Saving Mode ** CE Approved Unit
Insta-Therm Service Manual
2
SCHEMATIC
MODEL 16001
Insta-Therm Service Manual
3
SCHEMATIC
MODEL 16003, 16005
Insta-Therm Service Manual
4
SEQUENCE OF OPERATION
POWER SUPPLY
HEATING CIRCUIT
Electrical power is supplied to the unit by a 3 conductor service for single phase. Black conductor is hot. White conductor is neutral. Green and Yellow conductor is ground. Power is permanently supplied to the power switch through the high limit thermostat. Also to the open contacts of the main power relay.
Closing the main power switch feeds power to the cooling fan and the coil of the main power relay. Its contacts now close supplying 50% power to the 4 heaters through the current limiting solid state relay. When product is placed on the shelf, the normally open contact (S2) closes to supply full power through the current limiting solid state relay and two indicator lamps to the heaters.