Mercia Garden Products 04GREEN0406SD-V2 Instruction manual

General Instructions
Please retain product label and instructions for future reference
04GREEN0406SD-V2
4X6 GREENHOUSE
BEFORE YOU START PLEASE READ INSTRUCTIONS CAREFULLY
- Check the pack and make sure you have all the parts listed.
- When you are ready to start, make sure you have the right tools at hand (not supplied) including a Phillips screwdriver, Stanley knife, Wood saw, Step ladder, Hammer and a Drill with 2mm bit.
- Ensure there is plenty of space and a clean dry area for assembly.
TIMBER
As with all natural materials, timber can be aected during various weather conditions. For the duration of heavy or extended periods of rain, swelling of the wood panels may occur. Warping of the wood may also occur during excessive dry spells due to an interior moisture loss. Unfortunately, these processes cannot be avoided but can be helped. It is suggested that the outdoor building is sprayed with water during extended periods of warm sunshine and sheltered as much as possible during rain or snow.
x2
2mm Drill bit
**Protim Aquatan T5 (621)**
Your building has been treated with Aquatan.
All buildings should be erected by two adults
For ease of assembly, you MUST pilot drill all screw holes and ensure all screw heads are countersunk.
For ease of assembly, you will need a tape measure to check dimensions of components.
Winter = High Moisture = Expansion Summer = Low Moisture = Contraction
CAUTION
Every eort has been made during the manufacturing process to eliminate the prospect of splinters on rough surfaces of the timber. You are strongly advised to wear gloves when working with or handling rough sawn timber.
Our buildings are pre treated with a water based treatment**; this only helps to protect the product during transit and for up to 3 months against mould. To validate your guarantee and ensure longevity of the product, it is ESSENTIAL the building is treated with a wood preserver within the rst three months of assembly and thereafter in accordance with the manufactures recommendations. Care must be taken to ensure the product is placed on a suitable base.
BUILDING A BASE
When thinking about where the building and base is going to be constructed: Ensure that there will be access to all sides for maintenance work and annual treatment.
Ensure the base is level and is built on rm ground, to prevent distortion. Refer to diagrams for the base dimensions, The base should be slightly smaller than the external measurement of the building, i.e. The cladding should overlap the base, creating a run o for water. It is also recommended that the oor be at least 25mm above the surrounding ground level to avoid ooding.
TYPES OF BASE
- Concrete 75mm laid on top of 75mm hard-core.
- Slabs laid on 50mm of sharp sand.
Whilst all products manufactured are made to the highest standards of Safety and in the case of childrens products independently tested to EN71 level, we cannot accept responsibility for your safety whilst erecting or using this product.
Aquatan is a water-based concentrate which is diluted with water, the building as been treated by the correct application of Aquatan solution and then allowed to dry.
Aquatan is a decorative nish to colour the wood, which is applied industrially to timber fence panels and garden buildings.
Aquatan undiluted contains: boric acid, sodium hydroxide 32% solution, aqueos mixture of sodium dioctyl sulphosuccinat and alcohols: 2, 4, 6-trichlorophenol.
Pressure Treated Timber
Pressure treating is a chemical process which helps to protect wood against adverse weather which could lead to rot or insect damage.
The most common chemicals used to pressure treat wood are Alkaline Copper Quaternary (ACQ), Copper Azole (CA), and Micronized Copper Quaternary (MCQ).
Safety: Always wear gloves, eye protection and a dust mask when handling wood. Due to chemicals in pressure treated wood, never burn its sawdust or scraps; instead dispose in a landll.
For assistance please contact customer care on: 01636 880514
Mercia Garden Products Limited, Sutton On Trent, Newark, Nottinghamshire, NG23 6QN
Refer to the instructions pages for you specic product code
www.merciagardenproducts.co.uk
P 1
04GREEN0406SD-V2
Overall Dimensions:
Width = 1215mm Depth = 1887mm Height = 2066mm
Base Dimensions:
Width =1191mm Depth = 1862mm
Before assembly
please make sure you have a
suitable base ready to erect your
building
MADE IN GREAT BRITAIN
AI-04GREENROOF1217X1050-V1
10
11
10
Fascia 1075mm
11
Base Frame 1862mm
Please retain product label and instructions for future reference
7
Roof
S1260-1075mm
F4444-1862mm
8
8
Door
AI-04GREENDOOR550X1720-V2
AI-04GREENOW560X460-V1
9
9
Opening
Window
1
Door Side
AI-04GREENDS610X1543-V2
QTY 2
4
2
Sml Window Side
AI-04GREENWS1193X1543-V2
QTY 2
3
12
12
Base Frame 1103mm
F4444-1103mm
13
13
Roof Support Bar 1217mm
14
13
Door Frame 556mm
7
F2744-1217mm (8mm LIP, X2 66DEG CUTS)
F2744-556mm
15
Lrg Window Side
AI-04GREENWS1776X1543-V2
Door strip 1717mm x2
16
Roof trim 1241mm
S1230-1717mm
S1256-1241mm
18
17
Door strip 556mm
5
6
18
S1230-556mm
19
20
Door Gable Top
AI-04GREENDGT1864X426-V1
Plain Gable Top
AI-04GREENPGT1864X426-V1
Roof
(Opening Window)
AI-04GREENROOFOW1217X1050-V1
Buttery Hinges QTY 2
PI-07-0004 PI-07-0008 PI-07-0066
21
Finial QTY 2
Window Casement Stay
22
Wooden Knob
PI-04-0024SHED DIAMOND FINIAL
23
Butt Hinge QTY 2
Turn Button QTY 2
PI-07-0182
P 2
Nail Bag
30mm Screw x 33
40mm Screw x 8
50mm Screw x 60
70mm Screw x 8
16mm Screws x 6
20mm Screw x 6
30mm Black Screw x 18
Please retain product label and instructions for future reference
Step 2
Fix the corners of the Sml Window Side (No. 2) and the Lrg Window Side (No. 3) with 3x50mm screws as shown in the diagram.
*The Panel which will be the rear of the building sits inbetween the two side panels.*
3
2
Pre-Assembly
Before assembling remove the transportation blocks from the bottom of each panel.
Step 1
Lay the base frame down as shown in the diagram. Ensure the base is square and layed on level ground, x the base framing (No. 11) & (No. 12) together with 2 x 70mm screws per corner - pre drill to avoid splitting the timber.
3x50mm screws.
Pre drill
hole
50mm
screw
Step 3
Fix the remaining Sml Window Side (No. 2) at the corner using 3 x 50mm screws.
3x50mm screws.
Rear
Side
Front
2
8x70mm screws.
Pre drill
hole
70mm
screw
11
Side
12
Rear
11
Front
12
Pre drill
hole
50mm
screw
Rear
Side
Front
P 3
Loading...
+ 4 hidden pages