General Instructions
Please retain product label and instructions for future reference
03-LBRO1008-V7
10X8 COMBI SUMMERHOUSE V7
BEFORE YOU START PLEASE READ INSTRUCTIONS CAREFULLY
- Check the pack and make sure you have all the parts listed.
- When you are ready to start, make sure you have the right tools at hand (not supplied)
including a Phillips screwdriver, Stanley knife, wood saw, step ladder and drill with 2mm
bit.
- Ensure there is plenty of space and a clean dry area for assembly.
TIMBER
As with all natural materials, timber can be aected during various weather conditions.
For the duration of heavy or extended periods of rain, swelling of the wood panels may
occur. Warping of the wood may also occur during excessive dry spells due to an interior
moisture loss. Unfortunately, these processes cannot be avoided but can be helped. It is
suggested that the outdoor building is sprayed with water during extended periods of
warm sunshine and sheltered as much as possible during rain or snow.
x2
2mm Drill bit
**Protim Aquatan T5 (621)**
Your building has been treated with Aquatan.
Aquatan is a water-based concentrate which is diluted with water, the building as been treated by the correct
application of Aquatan solution and then allowed to dry.
Aquatan is a decorative nish to colour the wood, which is applied industrially to timber fence panels and
garden buildings.
All building’s should be
erected by two adults
For ease of assembly, you
MUST pilot drill all screw
holes and ensure all screw
heads are countersunk.
Winter = High Moisture = Expansion
Summer = Low Moisture = Contraction
CAUTION
Every eort has been made during the
manufacturing process to eliminate the
prospect of splinters on rough surfaces of the
timber. You are strongly advised to wear gloves
when working with or handling rough sawn
timber.
Our buildings are pre treated with a water based treatment**; this only helps to protect
the product during transit and for upto 3 months against mould. To validate your
guarantee and ensure longevity of the product, it is ESSENTIAL the building is treated
with a wood preserver within the rst three months of assembly and thereafter in
accordance with the manufactures recommendations. Care must be taken to ensure
the product is placed on a suitable base.
BUILDING A BASE
When thinking about where the building and base is going to be constructed:
Ensure that there will be access to all sides for maintenance work and annual
treatment.
Ensure the base is level and is built on rm ground, to prevent distortion. Refer to
diagrams for the base dimensions, The base should be slightly smaller than the external
measurement of the building, i.e. The cladding should overlap the base, creating a run
o for water. It is also recommended that the oor be at least 25mm above the
surrounding ground level to avoid ooding.
TYPES OF BASE
- Concrete 75mm laid on top of 75mm hard-core.
- Slabs laid on 50mm of sharp sand.
Whilst all products manufactured are made to the highest standards of Safety and in
the case of childrens products independently tested to EN71 level, we cannot accept
responsibility for your safety whilst erecting or using this product.
Aquatan undiluted contains: boric acid, sodium hydroxide 32% solution, aqueos mixture of sodium dioctyl
sulphosuccinat and alcohols: 2, 4, 6-trichlorophenol.
For assistance please contact customer care on: 01636 880514
Mercia Garden Products Limited,
Sutton On Trent,
Newark,
Nottinghamshire,
NG23 6QN
Refer to the instructions pages for you specic product code
www.merciagardenproducts.co.uk
P 1
03LBRO1008-V7
Please retain product label and instructions for future reference
Overall Dimensions:
Width = 3114mm
Depth = 2512mm
Height = 2146mm
Base Dimensions:
Width = 3016mm
Depth = 2413mm
Before assembly
please make sure you have a
suitable base ready to erect your
building
MADE IN GREAT BRITAIN
1
11
Storage Gable Left
AI-03LBRO1008-V7SGL
16
Storage Gable Right
12
13
Under Roof
AI-03LBRO1008-V7SGR AI-03LBRO1008-V7UR
17
18
14
Veranda
AI-03LBRO1008-V7V
15
Small Floor
AI-03LBRO1008-V7SF
19
2
3
4
5
Double Boarded Gable Top
AI-03LBRO1008-V7GTDB
Door Panel
AI-03LBRO1008-V7DP
6
Floor
AI-03LBRO1008-V7F AI-03LBRO1008-V7R
QTY x2
Back Panel Short Panel
AI-03LBRO1008-V7BP AI-03LBRO1008-V7SP
7
Roof
QTY x2
Short Window
Panel
AI-03LBRO1008-V7SWP
8
Storage Back
Panel
AI-03LBRO1008-V7SBP AI-03LBRO1008-V7STD
9
Storage Door
Panel
Internal Panel
AI-03LBRO1008-V7INP
10
Side Panel
AI-03LBRO1008-V7SP
Master Door
AI-03LBRO1008-V7MD
Slave Door
AI-03LBRO1008-V7SD AI-03LBRO1008-V7STD
Fixing Kit
22
5xFloor Blocks - 28x28x400mm
F2828-400mm
23
Cover Trim A - 12x56x1980mm
S1256-1980mm
24
2x Cover Trim B - 12x56x2000mm
S1256-2000mm
25
Cover Trim C - 12x56x2011mm
S1256-2011mm
26
Cover Trim D - 12x56x2040mm
S1256-2040mm
27
Cover Trim E - 12x56x2070mm
S1256-2070mm
28
2x Cover Trim F - 12x56x2080mm
S1256-2080mm
29
QTY x2
20
Gable Top Right
AI-03LBRO1008-V7GTR
Storage Door
21
Gable Top Left
AI-03LBRO1008-V7GTL
30
2x Side Fascia - 12x134x1557mm
S12134-1557mm
32
Door Stop
PLY TRIANGLE
34
Felt
36
Chrome Handle
PI-07-0162
38
31
2x Door Trim - 16x60x1698mm
33
35
37
2x Door Handles
PI-07-0001
F1660-1698mm (rounded edge)
2x Press Lock Base28x28x95mm
F2828-95mm
Press Lock
PI-07-0162
4x Barrel Bolt
PI-07-0067
4x Front Fascia - 12x134x1250mm
S12134-1250mm
Fixing Kit continues on P3
P 2
Please retain product label and instructions for future reference
39
40
41
42
Pre Assembly
Mortice Lock
PI-07-0017
12x Butt Hinge
PI-07-0066
Key Plate
PI-07-0017
4x Turn Button
PI-07-0034
Nail BagFixing kit cont..
PI-02-0352
Step 2
Flip the assembled Floor (No. 6) over and Place
70mm Screw x 10
the small oor (No. 15) ush against
the assembled oor.
50mm Screw x 119
30mm Black Screw x 4
30mm Screw x 162
Using 4x50mm screws x the small oor in
place as shown in the diagram.
6x50mm Screws
6
15
6
10mm Screw x 8
Felt Tacks x 165
Pre drill
hole
Step 3a
50mm
screw
16
18
Before assembling remove the transportation
blocks from the bottom of each panel.
Step 1
Place the 2 oor panels (No. 6) onto a rm
and level base , ensuring the
base has suitable drainage & is free from
areas where standing water can collect.
Secure the oors together using the
Floor Blocks (No.22) and 10x30mm
screws per oor.
Once tted, turn the oor assembly the
right way up.
Assembly of the main door and the
storage door.
40
Lay each door (No. 16, 2x No. 17 and
No. 18) at on a level surface, place a
hinge at the top, middle and bottom of
the door and x each hinge (No. 40) into
place using three 30mm screws, ensure
to pre-drill the holes rst. Position the
hinges as shown in the diagram (only
two doors have been shown in the
illustration) to ensure that they are in the
correct place before attaching the doors
to the door panel.
Place the door panels (No. 1 and No. 9)
16
1
17
17
9
18
at on the ground and the doors within
6
the aperture. Position the doors equally
within the space and then using 30mm
6
screws secure the doors in place.
72x30mm Screws
17
17 18
16
20x30mm Screws
Pre drill
hole
30mm
screw
22
Pre drill
hole
30mm
screw
P 3