BEFORE YOU START PLEASE READ INSTRUCTIONS CAREFULLY
- Check the pack and make sure you have all the parts listed.
- When you are ready to start, make sure you have the right tools at hand (not supplied) including a Phillips screwdriver, Stanley knife, wood saw, step ladder and drill with 2mm bit.
- Ensure there is plenty of space and a clean dry area for assembly.
TIMBER
As with all natural materials, timber can be aected during various weather conditions. For the duration of heavy or extended periods of rain, swelling of the wood panels may occur. Warping of the wood may also occur during excessive dry spells due to an interior moisture loss. Unfortunately, these processes cannot be avoided but can be helped. It is suggested that the outdoor building is sprayed with water during extended periods of warm sunshine and sheltered as much as possible during rain or snow.
x2
2mm Drill bit
**Protim Aquatan T5 (621)**
Your building has been treated with Aquatan.
Aquatan is a water-based concentrate which is diluted with water, the building as been treated by the correct application of Aquatan solution and then allowed to dry.
Aquatan is a decorative nish to colour the wood, which is applied industrially to timber fence panels and garden buildings.
All building’s should be erected by two adults
For ease of assembly, you MUST pilot drill all screw holes and ensure all screw heads are countersunk.
Winter = High Moisture = Expansion Summer = Low Moisture = Contraction
CAUTION
Every eort has been made during the manufacturing process to eliminate the prospect of splinters on rough surfaces of the timber. You are strongly advised to wear gloves when working with or handling rough sawn timber.
Our buildings are pre treated with a water based treatment**; this only helps to protect the product during transit and for upto 3 months against mould. To validate your guarantee and ensure longevity of the product, it is ESSENTIAL the building is treated with a wood preserver within the rst three months of assembly and thereafter in accordance with the manufactures recommendations. Care must be taken to ensure the product is placed on a suitable base.
BUILDING A BASE
When thinking about where the building and base is going to be constructed: Ensure that there will be access to all sides for maintenance work and annual treatment.
Ensure the base is level and is built on rm ground, to prevent distortion. Refer to diagrams for the base dimensions, The base should be slightly smaller than the external measurement of the building, i.e. The cladding should overlap the base, creating a run o for water. It is also recommended that the oor be at least 25mm above the surrounding ground level to avoid ooding.
TYPES OF BASE
- Concrete 75mm laid on top of 75mm hard-core.
- Slabs laid on 50mm of sharp sand.
Whilst all products manufactured are made to the highest standards of Safety and in the case of childrens products independently tested to EN71 level, we cannot accept responsibility for your safety whilst erecting or using this product.
Aquatan undiluted contains: boric acid, sodium hydroxide 32% solution, aqueos mixture of sodium dioctyl sulphosuccinat and alcohols: 2, 4, 6-trichlorophenol.
For assistance please contact customer care on: 01636 880514
Mercia Garden Products Limited, Sutton On Trent, Newark, Nottinghamshire, NG23 6QN
Refer to the instructions pages for you specic product code
www.merciagardenproducts.co.uk
P 1
01GRO0806DD-V2
Please retain product label and instructions for future reference
Overall Dimensions:
Length = 2513mm
Width = 1969mm
Height = 2111mm
Base Dimensions:
Length = 2387mm
Width = 1783mm
Before assembly
please make sure you have a
suitable base ready to erect your
building
MADE IN GREAT BRITAIN
Content
Fixing Kit
9
Fascia - 12x95x1120mm Qty 4
10
Door Frame Upright - 12x45x1732mm Qty 2
11
Door Frame Top - 12x45x1185mm
12
Window Strip - 12x45x1100mm
13
Tower Bolt Mounting Block - 12x45x120mm
14
Cover Trim - 12x30x1652mm Qty 4
1
Door Gable
4
2
Plain Gable
15
Door Cloaking strip
3
16
Finial Qty 2
20
Plain Side
5
6
Casement Stay
17
Felt
21
18
T-hinge Qty 6
Hasp & Staple
22
19
Tower Bolt
and Catch
Butt hinge Qty 2
7
8
Nail Bag
50mm Screw x 12
Window Side
Floor
Roof
Qty 2
Door
40mm Screw x 12
30mm Screw x 109
20mm Screw x 6
16mm Screw x 6
Window
Felt Tacks x 110
P 2
Please retain product label and instructions for future reference
Step 1
Fit the door frame onto the door gable using 4x30mm screws for each strip. The door frames should sit 15mm from the door aperture.
12x30mm Screws
11
30mm
screw
Pre drill
hole
10
15mm
Step 3
Remove transportation blocks from the bottom of each panel before beginning assembly. Each panel should have two blocks.
Step 2
Fix the T-hinges onto the doors and door frame as shown. using 30mm screws. Ensure that each hinge is xed to the doors going through to the framing.
42x30mm screws
Pre drill
hole
30mm
screw
21
Step 4
Place the oor on a rm and
5
5
level base, ensure base has suitable drainage free from areas where standing water can collect. (See front page for base requirements).
5