Menvier Security TS400, TS410 Operating Instructions

TS400 & TS410
Intruder Alarm Control Panels
Operating Instructions
Zone Location Home Set Chime
1 Armed / Omitted 2 Armed / Omitted 3 Armed / Omitted 4 Armed / Omitted 5 Armed / Omitted
F. Exit Always Armed
The TS400 and TS410 are 6 zone microprocessor based intruder alarm panels. Before attempting to operate the system, please ensure that you have read these instructions and discussed the operation of the system with the installation engineer. If you experience problems with the alarm system refer to the "Fault Finding" section on the back page.
Operator Controls & Indicators
2
1
4 5
6
7 8
9
0
2
3
1
2
4
3
5
6
7
Figure 1 Operator Controls & Indicators
1 Zone Indicators
Theseredindicatorsareused to showthe status of zones 1 to 5.
2 Unset Indicator
Thisgreenindicatorisusedtoindicate the status of the system, set or unset. It also flashes when the mains power to the system is removed or when the master user selects the user menu.
3 Tamper Indicator
This red indicator is used to indicate a system tamper alarm, i.e. someone removing the cover from a detector or control panel. The tamper indicator will also flash when the selecting "chime" circuits.
4 Final Exit Indicator
This red indicator is used to show the status of the final exit zone. The final exit zone is normally the front door or last detector triggered when leaving the building.
5 Keypad
10 digit keypad used for operating the system.
6 Away Key
The away key is used when full setting the system.
7 Home key
The home key is used when part setting the system.
Away Set
Theawaysetoptionisused to arm allzoneswhenyouleavethe premises. Before attemptingtoset the system, ensure that all doors and windows are securely closed. If pets are to be left inside the protected premises they must not have access to areas protected by movement detectors.
1 Enter the first 2 digits of your passcode followed by
[AWAY] . The internal sounder will sound, the unset indicatorwillgoout andthefinalexitindicatorwillflash.
2 Leave the premises via the designated exit route. 3 The internal sounder will change to a high pitched
tone, after 5 seconds a multi-tone sound will be heard and the system fully sets.
+
If the internal sounder changes to analarm tone, you must re-enter the premises and enter your passcode. Theindicators that are lit are the zones that prevented thesystemfrom setting. Checkthe relevant zonesand repeat above procedure.
Home Set
Thehome setoption is used when staying inside the premises and only armingsome ofthe zones. To program the zones that will be omitted see "Home Set Configuration" on page 7. Before attempting to set the system, ensure that all doors and windows are securely closed. If petsare to be left inside the protected premises they must not have access to areas protected by movement detectors.
1 Enter the first 2 digits of your passcode followed by
[HOME]. The internal sounder will emit a multi-tone sound, the unset indicator will go out and the final exit indicator will flash. The indicators for the zones that will be omitted will also flash.
2 Leave the area to be protected via the designated
exit route.
3 Whenthesecondmulti-tonesoundisheardthesystem
is part set.
+
If the internal sounder changes to analarm tone, you must proceed to the keypad and enter your passcode.The indicatorsthat arelit arethe zones that preventedthesystemfromsetting. Check the relevant zones and repeat above procedure.
3
The exit sounder will start, the unset
indicator will go out and final exit
indicator flashes.
All indicators are off when the
system is set.
Leave the building via the exit route. The
exit sounder will eventually change to a high pitched tone. When the tone stops
the system is fully set.
? ?
A multi-tone beep will be heard, the unset
indicator will go out and the final exit
indicator flashes. The zones that will be
omitted will also flash (e.g. zones 4 and 5).
All indicators are off when the
system is set.
Leave the protected area via the exit
route. When the multi-tone beep is
heard the system is part set.
? ?
Unsetting The System
To unset the system, proceed as follows: 1 Enter the premises via the designate entry door. The
internal sounder will sound.
2 Proceeddirectly to the keypad and enter all 4 digits of
your passcode.
3 The sounder will stop and the unset indicator will light.
The system is now unset.
+
If the programmed entry time is exceeded, the internal sounder will emit an alarm tone for the duration of the programmed entry time. If a valid passcode is not entered at the keypad before the addition time expires, a full alarm will occur, i.e. internal and external alarm.
Resetting After an Alarm
When an alarm has occurred the system will require resetting before the system can set again. Your alarm company will have configured your system to be reset by one of the following methods:
User Reset: Engineer Reset: Remote Reset:
When an alarm occurs with the system full or part set proceed as follows: 1 Enter the premises via the designate entry route. The
internal sounder will sound.
2 Proceeddirectly to the keypad and enter all 4 digits of
your passcode.
3 The sounder will stop and the unset indicator will light.
The zone indicators associated with the alarm condition will also light.
4 Check the system as necessary. 5 Enter your passcode again to reset the system. The
zone indicator that was lit will go out. The system is now reset.
+
If after unsetting the system the internal sounder continues to emits a pulsed tone, the system will require a reset by either engineer or remote reset. To silence the pulsed tone, enter your passcode.
Forengineerresettelephone: For remote reset telephone:
4
Enter the building via the designated
entry point. Proceed directly to the keypad
and enter all 4 digits of your passcode.
The system is now unset.
? ?? ?
Enter the building via the designated
entry point. Proceed directly to the keypad
and enter all 4 digits of your passcode.
The system is unset and the zone that
caused the alarm is indicated
(e.g. zone 3).
? ?? ?
? ?? ?
The system is now reset.
Bell Test
This function allows user 1 to periodically test the operation of the internal sounders, external sounders and strobe.
1 Enter the first 3 digits of your passcode then [HOME]
then [1].
2 All indicators will light and the internal sounder will
operate for five seconds.
3 Thentheexternalsounderwilloperateforfiveseconds. 4 Then the external strobe will operate for fifteen
seconds.
5 Whenthetestiscompleted,thesystemwill return to the
unset mode.
6 Tostopthe test atanytime and returnthesystem to the
unset mode, press [0].
Walk Test
This option allows user 1 to periodically test the operation of detectors and door contacts. Operating detectors whilst the system is in the walk test mode will cause the internal sounder to emit a pulsed tone and the appropriate zone indicator to light.
1 Enter the first 3 digits of your passcode then [HOME]
then [2].
2 Operateeachzone inturnby openingdoorsfitted with
alarm contacts and walking in front of movement detectors.
3 When the test is completed press [0]. A high pitch
acceptancetone willbe heard and the system returns to the unset mode.
5
All indicators light and the internal sounder operates for 5 seconds.
a)
When the test is completted the system
returns to the unset mode.
? ?? 1
The external sounder operates for 5 seconds.
b)
The strobe operates for 15 seconds.c)
Operate each zone in turn (e.g. zone 1).
a)
The system is now in the unset mode.
? ?? 2
0
The appropriate indicator will light and the internal sounder will pulse.
b)
When finished pressc)
Changing Passcode 1 (Master)
This option allows user 1 to change their passcode. The default passcode when the panel leaves the factory is 5 6 7 8.
1 Enter the first 3 digits of your passcode then [HOME]
then [4].
2 Indicators 1 to 4 will light. 3 Enter your new passcode, as you enter each digit the
indicators will go out one by one.
4 On entering all four digits, indicators 1 to 4 will light
again.
5 Re-enter your new passcode again for confirmation,
asyouentereachdigit the indicatorswillgooutone by one.
6 Afterentering your new passcode for the second time
the system will return to the unset mode.
7 A rising tone indicates the new passcode was
accepted, a falling tone indicates an error and the above procedure must be repeated.
Changing Passcode 2
This option allows user 1 to change user 2 passcode. 1 Enter the first 3 digits of your passcode then [HOME]
then [6].
2 Indicators 1 to 4 will light. 3 Enter the new passcode, as you enter each digit the
indicators will go out one by one.
4 On entering all four digits, indicators 1 to 4 will light
again.
5 Re-enterthe new passcode again for confirmation, as
you enter each digit the indicators will go out one by one.
6 After entering the new passcode for the second time
the system will return to the unset mode.
7 A high rising tone indicates the new passcode was
accepted, a falling tone indicates an error and the above procedure must be repeated.
+
The second user passcode will be lost if all power to the control panel fails.
6
Indicators 1 - 4 light.
Enter new passcode.
A rising tone indicates acceptance.
A falling tone indicates an error.
? ?? 6
Indicators 1 - 4 light again.
Enter new passcode for confirmation.
Indicators 1 - 4 light.
Enter new passcode.
A rising tone indicates acceptance.
A falling tone indicates an error.
? ?? 4
Indicators 1 - 4 light again.
Enter new passcode for confirmation.
Home Set Configuration
This option allows user 1 to select which zones will be omitted when a "Home Set" is selected. The final exit zone cannot be omitted when selecting zones.
1 Enter the first 3 digits of your passcode then [HOME]
then [7].
2 Press keys [1] to[5] to turn zone indicators 1 - 5 on and
off.Whenazoneindicator is lit thezonewillbeomitted. When a zone indicator is off the zone will be armed.
3 When completed press [0]. A rising acceptance tone
will be heard and the system returns to the unset mode.
+
If zones 3, 4 or 5 cannot be selected then they have been programmed by your alarm company for alternative operation, i.e. keyswitch, Fire or PA.
Chime Feature
This feature allows the selected zones to generate a two-tone beep every time the zone is triggered when the system is unset. This may be used as a courtesy warning of the opening of a shop door etc.
1 Press [HOME] then [HOME]. 2 Press keys [1] to[6] to turn zone indicators 1 - 5 on and
off (6 is used for the final exit zone). When a zone indicator is lit the zone will be selected as "Chime". When a zone indicator is off the zone will not chime.
3 When completed press [0]. A rising acceptance tone
will be heard and the system returns to the unset mode.
+
If zones 3, 4 or 5 cannot be selected then they have been programmed by your alarm company for alternative operation, i.e. keyswitch, Fire or PA.
7
Press keys [1] to [5] to select zones.
e.g. Press [4] then [5].
The system is now in the unset mode.
? ?? 7
Zones 4 and 5 are now selected
to be omitted.
0
When finished press
Press keys [1] to [6] to select chime zones.
e.g. Press [6] for the final exit.
The system is now in the unset mode.
The final exit zone is now selected
for chime.
0
When finished press
Fault Finding
Problem I enter my passcode to set the system but the system emits an intermittent sound
and one of the indicator zones is on.
Cause The tone indicates that a detector is active or a door has been left open. The
indicator that is on, indicates which detector or door is active.
Action Close doors, wait 10 seconds and try again. If the problem persists contact your
alarm company.
Problem After unsetting the system one of the zone indicators remained on.
Cause The indicator shows the alarm zone that was activated when the system was set. Action Pleaserefertothesectionon"ResettingAfteranAlarm"aftercheckingthebuilding.
Problem The system emits an two-tone beep every time I open certain doors.
Cause The system has a facility called "Chime", which causes the internal sounders to emit
a two-tone beep every time certain zones are activated.
Action To turn this facility on or off, see the section on "Chime".
Problem The internal sounder and TAMPER indicator comes on during the day.
Cause This shows that the panel has detected a "tamper" fault, i.e. a wiring fault or a cover
removed from a detector, control panel or external siren.
Action Call your alarm company immediately.
Problem The system was in the unset mode and the internal sounder operated, and
external sounder sounds pulses on and off.
Cause The system has a facility to monitor smoke detectors (zone 4). If one of these is
activated, the external siren will be pulsed on and off to show that the alarm was caused by a fire and not a burglar.
Action Check the smoke detector to ensure that they are clear of smoke. If the problem
persists contact your alarm company.
Problem The UNSET indicator is flashing.
Cause The mains power to the panel is off or the internal fuse has blown. The system will
operate from the internal battery for about 8 hours.
Action If the mains to the building is on, contact your alarm company.
Problem When setting the system, the external strobe starts to flash.
Cause This shows that the system has not set correctly. Action Re-enter the building, clear the indications and try again.
Problem Although I follow the correct procedure, the system will not allow me to change
my passcode.
Cause Thesystem analyses the new codeentered andmay refuseto accept certain code
combinations for technical reasons.
Action Try repeating the procedure with a different passcode.
18015 Drg No. 33:1939:00 Issue 01 Doc. 02 April, 1997
Loading...