Mendota DXV35 TIMBERFIRE, DXV45DT4, DXV42 TIMBERFIRE, M50, DXV60 Installation Manual

Page 1
85-03-01115-E DXV35 TIMBERFIRE
Installation and Operating Instructions
MODEL NO. DXV35 TIMBERFIRE DIRECT VENT GAS FIREPLACE HEATER
WARNING: If the information in these instructions
loss of life.
AVERTISSEMENT. Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au minimum le risque d'incendie ou d'explosion ou pour
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Ne pas entreposer ni utiliser d'essence ni d'autres vapeurs
ou liquids inflammables dans le voisinage de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incendies.
- L'installation et l'entretien doivent être assurés par un installateur ou un service d'entretien qualifié ou par le fournisseur de gaz.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gasses, unless a
certified kit is used.
Cet appareil peut être installé dans une maison
préfabriquée (É.-U. seulement) ou mobile déjà installée à demeure si les règlements locaux le permettent. Cet appareil doit être utilisé uniquement avec les types de gaz indiqués sur la plaque signalétique. Une trousse de conversion est fournie avec cet appareil.
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and must be installed.
Une barrière conçue pour réduire le risque de brûlures
du verre chaud est fournie avec cet appareil et doit être
installée.
Page 2
85-03-01115 DXV35 TIMBERFIRE Page I
READ ME FIRST
1.1 CAUTION STATEMENTS TO PARENTS OF YOUNG CHILDREN
If th is fireplace is installed in an isolated bedroom, study o r oth er room, always operate this appliance in thermostatic temperature -contro ll ed mod e. Do not operate in Manual mode. Doing so can lead to very high room temperatures which can be hazard ous t o the room occupants’ health.
Do not place young children in cribs, bassinets or the like in th e vicinity o f t his appliance. Young child ren may be vulnerable to high temperatures that this fireplace ca n create locally.
Young children should be carefu lly supervised and never left unatt end ed when they are in the same room as the fireplace. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individual s in t he house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and oth er at ­risk individuals out of the room and away from hot sur fa ces. Th is physical barrier is in addition to th e required glass barrier Screen.
1.2 INITIAL FIRING AND CURING PROCEDURE
This product requires an initial heat curing cycle during which some materials used in the manufacturing process will burn off and the powder paint goes through a hardening cycle. During the initial curing phase, some smoke and odor will be emitted. This is normal. The installer should perform these initial curing cycle procedures as the final step in the installation process before finishing materials are installed around this fireplace. See chapter 3.1.1 Mendota Fireplace Curing Instructions. Read and follow all instructions given in this Chapter and perform the 3-step curing cycle. After the 3-step curing cycle has been completed, all smoking will have stopped. Some slight odors may remain. With subsequent use of this Fireplace, odors will slowly dissipate and disappear.
ODOR RISKS
If th is appliance is not operated for an extended p eriod ( three months or longer), when first fired again, exp ect odors of burnt dust and lint; just like when turning on your home heating system for the fir st time in the Fall.
1.3 HOT SURFACES ARE NORMAL
Be aware that the surface in front of, above and adjacent to this heater appliance can be too hot to touch. As long as all required clearances to combustibles are met and the required finishing materials are used, this appliance will perform safely. Note that the exposed surfaces immediately surrounding the Fireplace can have surface temperatures that are too hot to touch. This level of surface temperature is considered normal and does not indicate any hazardous situation.
WARN ING: The supplied barrier scre en must be installed, always, when this fireplace is in operation. Do not place any object directly in front (within 60”) or directly above (on t he front edge of the mantel). This is a heating appliance. Areas directly in front and above this appliance wil l b e very hot and can damage most household objects if placed too close. Keep Furniture pieces at least 60” away in front of the barrier screen.
1.4 PERIODIC AND ANNUAL CLEANING ARE REQUIRED
See Required Periodic Inspections, Chapter 6.1 and Required Annual Maintenance, Chapter 6.3. Periodic and Annual cleaning and general services are required at least once a year in the Summer or early Fall. Cleaning thermocouple, thermopile, pilot sparker rod and pilot hood body is required at least once per year. Cleaning of burner ports, gas orifice areas is required once a year due to insects’ nesting probability due to Mercaptan addition in Natural Gas (Mercaptan attracts insects).
Page 3
Table of Contents
1.1 CAUTION STATEMENTS TO PARENTS OF YOUNG CHILDREN.. 2
1.2 INITIAL FIRING AND CURING PROCEDURE ....................... 2
1.3 HOT SURFACES ARE NORMAL ....................................... 2
1.4 PERIODIC AND ANNUAL CLEANING ARE REQUIRED ............ 2
2.1 SAFETY AND WARNING INFORMATION ................. 5
2.2 SAFETY WARNINGS..................................................... 6
3.1 GENERAL TECHNICAL REFERENCES .............................. 10
3.2 MECHANICAL TECHNICAL REFERENCES ......................... 12
3.2.4.4.1 Horizontal Clearance Reduction by 66% ...................... 24
3.2.4.4.2 Horizontal Clearance Reduction by 50% ...................... 24
3.2.6.4.1 Paint Types Approved for Use ..................................... 28
3.2.6.4.2 Sealants Type Approved for Use.................................. 28
3.2.6.4.3 Wood Application Cautions ......................................... 28
3.2.7.3.1 Mendota Cool Wall ........................................... 31
3.2.7.3.2 Versiheat ................................................. 32
3.2.7.3.3 FlexHeat ........................................... 33
3.3 ELECTRICAL TECHNICAL REFERENCES ............................ 40
3.4 PLUMBING TECHNICAL REFERENCES ............................. 42
4.1 INSTALLATION CHECKLIST ........................................... 46
4.2 PREPARING FOR INSTALLATION ........................... 47
4.3 NATURAL GAS TO LPG CONVERSION ........................... 51
4.4 VENTING ................................................................. 54
Page 4
4.5 TIMBERFIRE LOG SET INSTALLATION ................... 61
4.6 AIR SHUTTER CONTROL AND FLAME APPEARANCE ......... 66
4.7 LIGHTING CHECKLIST ................................................. 67
5.1 AESTHETIC CONSIDERATIONS ..................................... 68
5.2 HEATING PERFORMANCE ........................................... 68
5.3 IMPORTANT INFORMATION FOR HOMEOWNER .............. 68
5.4 FIRST TIME LIGHTING INSTRUCTIONS ........................... 69
5.5 TO TURN OFF GAS TO FIREPLACE ................................ 70
5.6 FREQUENTLY ASKED QUESTIONS ......................... 71
5.7 WHAT MAINTENANCE IS REQUIRED? ............................ 72
6.1 REQUIRED PERIODIC INSPECTIONS ............................... 74
6.2 CLEANING VIEWING GLASS ......................................... 74
6.3 REQUIRED ANNUAL MAINTENANCE ............................. 75
6.4 OVER FIRING OR UNDER FIRING OF BURNER ................. 76
6.5 PILOT OUTAGE AND RE-LIGHTING ................................ 76
6.6 BURNER FLAME HEIGHTS REFERENCE DIAGRAM ............ 76
6.7 REPLACEMENT PARTS INFORMATION .................. 77
7.1 FINAL INSTALLATION AND HOMEOWNER
CHECKLIST ....................................................... 80
7.2 WARRANTY POLICY STATEMENT .................................. 81
7.3 CONDITIONS ............................................................ 82
Page 5
85-03-01115 DXV35 TIMBERFIRE Page 5
GENERAL INFORMATION
2.1 SAFETY AND WARNING INFORMATION
Building Permit & Inspection Requirements
All installations of Mendota Fireplaces must comply with all the requirements stated in this Installation and Operating Manual. The dealer and/or installer must obtain all required building permits and inspection approvals from the local building inspection department or the local jurisdiction. To validate warranty coverage, Mendota may require facsimile copies of the building permit and inspection approval forms. Failure to provide adequate proof that the installation conforms to all local requirements and the requirements stated in the Installation and User Manual will void all applicable warranties.
Other Cautions
CAUTION: Each installation must conform to all local, state and national co des. R efer to the national fuel
gas code and local zoning and code authorities for detai ls on installation requirements. The Mendot a Fir epl ace must be vented to the outside in accordance with th e l atest ed ition of the National Fuel Gas Cod e. In the absence of local codes, the installation must con for m to the mo st current edition of the National Fuel Gas Code ANSI Z223.1, also known as NFPA 54.
CAUTION: The Mendota Fireplace may be installed in a manufactured (mobil e) home aft er the first s ale of the home. Manufactured home (mobile home) in st allat ion must conform with the Manufactured Ho me Construction and Safety Standard, Title 24 CFR, Part 3280, or, when su ch a standard is not applicable, the Standard for Manufactured Home Installations, A NSI A225.1/NFPA 501A, o r CSA Z 240.4-Gas Equipp ed Mobile Housing. Consult your local building official. NOTE: For mobile home installations, unit must be bolt ed to the Manufactured home floor and properly grounded.
INSTALLER: Leave this manual with the app lian ce. CONSUMER: Retain this manual for future reference. INSTALLATEUR : Laissez cette notice avec l’appar eil. CONSOMMATEUR : Conservez cette notice pour
consultation ultérieure.
Page 6
85-03-01115 DXV35 TIMBERFIRE Page 6
2.2 SAFETY WARNINGS
HIGH-ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher than 7,500 ft., understand the need for gas
input derating. Contact your local gas company to see if your gas type is already derated for your altitude or contact Mendota Technical Service for support. INSTALLER NOTE: These instructions are to remain with homeowner. Be sure to read and understand all instructions carefully before starting the fireplace. Failure to follow these instructions may result in a possible fire hazard leading to property loss, injury or even death and will void all warranty.
FOR YOUR SAFETY: A qualified installer, service agency, or the gas supplier must perform installation and service. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WARNING: Do not operate this appliance with the glass removed, cracked or broken. A licensed or qualified person should do replacement of glass.
AVERTISSEMENT: Ne pas utiliser l’appareil si le panneau frontal en verre n’est pas en place, est craqué ou brisé. Confiez le remplacement du panneau à un technicien agréé. WARNING: Mendota gas fireplaces are heat producing appliances. Do not burn wood, paper or other materials in
this fireplace. This fireplace is designed as a supplemental
heat source. It is advisable to have an alternative primary heat supply.
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a
qualified installer, service agency or the gas supplier.
In the Commonwealth of Massachusetts:
Installation must be performed by a licensed plumber or gas fitter; a CO detector shall be installed in the room where the appliance is installed.
This appliance may be installed in an aftermarket,
permanently located, manufactured (mobile) home (USA Only), where not prohibited by local codes. This appliance is only for use with the type(s) of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified conversion kit is used. Cet appareil peut être installé dans un maison préfabriquée (mobile) déjà installée à demeure si les règlements locaux le permettent.
Cet appareil doit être utilisé uniquement avec les types
de gas indiqués sur la plaque signalétique. Ne pas l’utiliser avec d’autres gas sauf si un kitde conversion certifié est installé.
Page 7
85-03-01115 DXV35 TIMBERFIRE Page 7
Safety Standards and Warnings
Do not operate this appliance with the glass removed, cracked or broken. Only glass doors certified with this appliance shall be used.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this ap pliance and must be installed. If the barrier beco mes damaged, the barrier shall be replaced with the manufacturer's barrier for this appliance.
Any Barrier Screen or guard removed for ser vicing must be replaced before operating fireplace. Tout écran ou protecteur retiré pour permett re l’entretien de l’appa reil do it être remis en place avant de
mettre l’appareil en marche. This un it is not for use with solid fuel. Ne pas utiliser avec du combustible solide. Insta lla tion and repair should be performed by a qualified service person. The fireplace and venting sy st em
shoul d be inspected before initial use and at least annually by a professional service person. Mor e fr equ ent cleaning may be required due to excessive lint fro m carp etin g, bedding, material, etc. It is imperative that the unit’s control compartment, burners and c irculating air passageways are kept clean t o provide for adequate combustion and ventilation air.
L’installation et la réparation devrait être confiées à un technicien qualifié. L’appareil devrait faire l’objet d’une inspection par un technicien professionnel a vant d’ êt re u tilisé et au moins une fois l’an par la suite.
Des nettoyages plus fréquents peuvent être nécessaires si les tapi s, la lit erie, et cetera produisent une quantité importante de poussière. Il est essen tiel que les comparti ments abritant les commandes, les brûleurs et les conduits de circulation d’air de l’appareil soient tenu s p ropres.
Always keep the fireplace clear and free from combustib le materials, gasoline, and other flammable vapors and liquids.
Never obstruct the flow of combustion an d ventilation air. Keep the front of the fireplace clear of all obstacles and materials for servicing and proper operation. Use only Mendota approved Screens, Fronts and Tr im Kits.
Due to high temperature, the firepl ace should be located out of traffic are as and away fro m furnitu re and
draperies. En raison des températures élevées, l’a ppareil devrait être installé dans un endroit où il y a peu
de circulation et loin du mobilier et des tentures. Cloth ing or flammable material should not be p laced on or near the fireplace. On ne devrait pas placer de vêtements ni d’autres matières inflammables sur l’appareil ni à proximité. Chil dren and adults should be alerted to the hazards of high surface temperature and should stay away to
avo id burns or clothing ignition. The door glass, surrounding walls and obj ects can be too hot to touch. Les enfants et les adultes devraient être inform és des dangers que posent les températures de surfa ce
élevées et se tenir à distance afin d’év iter des brûlures ou que leurs vêtements n e s’enflamment. Young children should be carefu lly supervised when they are in th e same room as the fireplace. Toddlers,
young children and others may be susceptible to a ccidenta l c ontact burns. A physical barrier is recommended if there are at risk individuals in the hou se. To r est rict access to a fireplace or stov e, install an adjustable safety gate to keep toddlers, young children and oth er a t -risk individuals out of the room and away fro m hot surfaces. This physical barrier i s in addition to the required glass barrier Screen .
Les jeunes enfants devraient être sur veillés étroitement lorsqu’ils se trouvent dan s la même pièce que
l’appareil. Les tout petits, les jeunes enfants ou les adu ltes peuvent subir des brûlures s’ils viennent en contact avec la surface chaude. Il est recomman dé d’installer une barrière physiqu e si des personnes à risques habitent la maison. Pour empêcher l’accès à un foyer ou à un po êle, installez une barrière de
sécurité; cette mesure empêchera les tout petits, les jeun es enfan ts et toute autre personne à risque d’avo ir accès à la pièce et aux surfaces chaudes.
Th ese un its must use one of the vent systems desc ribed in th e Flu e Venting section of this manual.
Page 8
85-03-01115 DXV35 TIMBERFIRE Page 8
This gas fireplace and vent system must be vented directly to the outsid e and must never be attached to a chimney serving a separate solid fuel-burning fireplace. Each gas fireplace must use a separate vent sy stem. Common vent systems are prohibited .
Th e ven t sy stem for this fireplace must be periodically exa min ed by a qualified service agency to maintain venting performance and safety . If the vent-air intake system is disassembled for any reason, reinstall per the in st ructions provided for the initial installatio n.
Inspect the external vent cap on regular basis (monthly) to mak e sure that no debris is interfering with the airflow. The flow of combustion and ventilation air are n ot to be obstructed.
Do not abuse the glass door assembly by striking the glass, slamming th e d oor shut, etc. Use only authorized parts and materials obtained from Mendota Hearth when replacing defective or
damaged glass, log sets, media, firebox inner liners or trim kit s. Do not use abrasive cleaners on the glass door a ssemb ly. Do not attempt to clean the glass door wh en it is
hot. Use Mendota recommended cleaner, Kel Kem. Turn off the gas before servicing this fireplace. It is recommended that a q uali fied ser vice technician
perform a fireplace check-up at the b eginning of each heating season. Do not place furniture or any other combustible household objects within 60” of the fireplace front, per fire
sa fety cod e. This vented gas fireplace heater is not for use with air filter s. Foyer au gaz à évacuation. - Ne pas utiliser avec du combustible solide. Keep burner and control compartment clean. See insta llat ion and operating instructions accompanyi ng
fir eplace. S'a ssurer que le brûleur et le compartiment des commandes sont propres. Voir les instructions d'installation
et d 'utilisation qui accompagnent l'appareil. WARNING: Improper installation, adjustm ent, alt eration, service or maintenance can cause injury or
property damage. Refer to the owner’s infor mat io n manual provided with this fireplace. For assistance or additional information consult a qualified installer, service agency or th e gas supplier.
L'A VERTISSEMENT: L'installation inconvenante, ajustement, modifica tion, service ou entretien peut causer le do mmages de propriété ou blessure. Référer au manu el d 'in fo rmation de propriétaire fourni cet appareil. Pour l'assistance ou information supplémentaire consulte un qualifiée installeur, agence de service ou le fournisseur de gaz.
Do not use this fireplace if any part has been und er water. Immediately call a qualified service technician to insp ect the fireplace and to replace any part of the contro l sy st em and any gas control, which has been underwater.
Ne pas utiliser cet appareil s’il a été plongé, même partiellement, dans l’eau. Appeler un technicien quali fié
pour inspecter l’appareil et remplacer toute partie du système de co mmande et toute commande qui a été plongée dans l’eau.
Do not use any fronts or doors with this fireplace unless they are certified by Mend ota and installed by a certified installer.
Seu les d es portes certifiées pour cet appareil doivent être utilisées.
Page 9
85-03-01115 DXV35 TIMBERFIRE Page 9
Requirements for The Commonwealth of Mass.
The information in this section applies to all installations performed in the Common Wealth of Massachusetts only.
a. For all side wall, horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole
or in part for residential purposes and where the side wall exhaust vent termination is less than seven (7) feet above grade, the following requirements shall be satisfied:
1. If there is no carbon monoxide detector with an alarm already installed in compliance with the most current
edition of NFPA 720, NFPA 70 and the Massachusetts State Building code in the residential unit served by the side wall horizontally vented gas fueled equipment, a battery-operated carbon monoxide detector with an alarm shall be installed in compliance with the most current edition of NFPA 720. NFPA 70 and the Massachusetts State Building Code.
2. In addition to the above requirements, if there is not one already present, a carbon monoxide detector with an
alarm and a battery backup shall be installed and located in accordance with the installation requirements supplied with the detector on the floor level where the gas equipment is installed. The carbon monoxide detector with an alarm shall comply with 527 CMR, ANSI/UL 2034 Standards or CSA 6.19 and the most current edition of NFPA 720. In the event that the requirements of this subdivision cannot be met at the time of the completion of the installation of the equipment, the installer shall have a period of thirty (30) days to comply with this requirement; provided, however, that during said thirty (30) day period, a battery-operated carbon monoxide detector with an alarm shall be installed in compliance with the most current edition of NFPA 720, NFPA 70 and the Massachusetts State Building Code. In the event that the horizontally vented gas fueled equipment is installed in a crawl space or an attic, the carbon monoxide detector may be installed on the next adjacent habitable floor level. Such detector may be a battery-operated carbon monoxide detector with an alarm and shall be installed in compliance with the most current edition of NFPA 720, NFPA 70 and the Massachusetts State Building Code.
3. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a
minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2)” in size, “GAS VENT DIRECTLY BELOW, KEEP CLEAR OF ALL OBSTRUCTIONS”
4. A final inspection by the state or local gas inspector of the side wall horizontally vented equipment shall not be
performed until proof is provided that the state or local electrical inspector having jurisdiction has granted a permit for installation of carbon monoxide detectors and alarms as required above.
b. EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2) (a) 1 through 4:
1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current
edition of NFPA 54 as adopted by the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate
from the dwelling, building or structure used in whole or in part for residential purposes.
c. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system
design or venting system components with the equipment, the instructions for installation of the equipment and the venting system shall include:
1. A complete parts list for the venting system design or venting system; and
2. Detailed instructions for the installation of the venting system design or the venting system components.
d. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the
parts for venting the flue gases, but identifies “special venting systems”, the following shall be satisfied:
1. The referenced “special venting system” instructions shall be included with the appliance or equipment
installation instructions; and
2. The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall
include a parts list and detailed installation instructions.
e. A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all
venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation
Page 10
85-03-01115 DXV35 TIMBERFIRE Page 10
TECHNICAL REFERENCES
Read and understand all information provided under this section, Technical References, before you begin the installation of this product. Failure to follow all technical reference information, use of components or parts not approved or use of improper installation procedures can lead to a fire or explosion causing property damage, personal injury or loss of life.
3.1 GENERAL TECHNICAL REFERENCES
Caution: Before igniting the pilot or burn er s, p er fo rm th e follo win g in sp ec tions and verifications:
Check glass gasket seal. Visually inspect glass gasket, especially at the corners of the glass piece. Glass gasket is installed as a 4­piece assembly. Check joints between the gasket pieces at the corners. They should butt against each other to create a seal. Gaps between gasket pieces can cause exhaust leaks and lead to acrid smell concerns. Check for gas leaks at all fittings.
During the first burning cycle of this Fireplace, ensure the convection blower is running at level three during the first two hours of initial burn. After two hours of initial burn, allow fireplace to cool. Proceed with Mendota Fireplace Curing Instructions,
Chapter 3.1.1.
This fireplace must be installed and serviced by a qualified installer, service agency, or the gas supplier. Any adjustments to burner, pilot, logs or coal bed must be made by a qualified installer, service agency, or the gas supplier. If pilot goes out, always wait 5 minutes before attempting to relight pilot. Never block off convection air openings or paths. Trim panels or surrounds shall not seal ventilation openings in the fireplace. Always use Mendota decorative fronts and Mendota approved vent systems and vent caps only.
Keep the flue warm
It is required to leave the pilot light running during winter months when outside daily high temperatures remain 50oF or lower. Doing so will eliminate heat loss from the home through the Fireplace glass door and will increase flue draft during startups.
WARNING
FIRE RISK/ODOR RISK
This fireplace must be installed on top of wood, masonry or metal floor extending the full width and depth of this
fireplace.
An R-1 Rated Hearth Protection Pad, 12” deep, is required unless this fireplace is elevated at least 6” above floor
level of the room. For every 1” this fireplace is elevated, you may reduce the hearth pad depth by 2”. Locate and install appliance to all clearance specifications in manual.
Verify glass gasket seal before firing unit the first time. Verify proper latching of glass frame onto unit body.
Understand that this appliance requires a break-in/curing period during which small amounts of smoke and curing
smells will be emitted.
Page 11
85-03-01115 DXV35 TIMBERFIRE Page 11
Mendota Fireplace Curing Instructions
ATTENTION
It is important that the blowers are turned on dur ing this step to prevent the curing smoke from staining the wal l fini sh ab ove the fireplace. Mendota recommends completing Step 1 pr ior to install ation of wall finish mat erials.
Visib le smoke and strong odor are to be expected during this step. If desired, disable smoke alarms before this step, smoke from the initial curing c ycle will set off smoke alarm s. Open doors and windows of the ho me to circulate fresh air.
Step 1: Expelling Initial Smoke and Odors
Please refer to ,LIGHTING INSTRUCTIONS, if you have questions on how to operate your Mendota.
Complete the installation of any barrier screen (required), surround, front or doors.
Turn the fireplace on
Set the Flame Height to Hi.
Set the Fan Speed Control to medium speed.
Run the fireplace with these settings for a minimum of 2 hours.
Turn the fireplace off and let it cool.
Step 2: High Heat Curing Cycle
Turn the fireplace on.
Set the Flame Height to Hi.
Set the Fan Speed Control to Off.
Run the fireplace with these settings until curing odors have diminished.
When odors have diminished leave the fireplace turned on and continue to Step 3.
Step 3: Final Curing Cycle
With the fireplace still turned on from Step 2.
Set the Fan Speed Control to the lowest setting Level 1.
If any new curing odors are detected, continue to run the fireplace with this setting until the curing odors have
diminished.
ATTENTION: Slight odors may still be noticeable on future startups of the fireplace. These will diminish over time as the
fireplace is used.
Additional Curing Information
It is not unusual for a fireplace to require more than 10 continuous hours on high for curing odors to diminish. There are variables that can extend or shorten the curing time such as decorative fronts, doors, facing materials and their application. Finish materials around the fireplace are subject to high temperatures. Finishing materials used over the fireplace in the non­combustible zone can see temperatures around 350° F. Materials used around the fireplace must be rated for these temperatures. Failure to use adequate materials can result in odor problems. Please refer to Chapter 3.2.4.3 of this manual for information on appropriate finishing materials. Please be aware that materials used around the fireplace will heat up and have the potential to cause odor issues. Adhesives, glue, wall substrate, wall finish material, paints and polishes are common materials that if used incorrectly will cause odor issues. Mendota is not responsible for any odor issues caused by materials used around the fireplace.
Page 12
85-03-01115 DXV35 TIMBERFIRE Page 12
3.2 MECHANICAL TECHNICAL REFERENCES
Labels
Listing Label
The listing label is in the air gap beneath the firebox behind the lower grill of the Fireplace. It is secured to a chain and can be pulled out to be viewed.
Figure 3-1 Listing Label
Page 13
85-03-01115 DXV35 TIMBERFIRE Page 13
Other Warning and Caution Labels
A few warnings or caution labels are attached to this appliance body as required per code to inform you of important facts. Make certain you heed all the warning and caution statements during installation and maintenance of this appliance.
Figure 3-2
Figure 3-3
Figure 3-4
Figure 3-5
Figure 3-6
Figure 3-7
Figure 3-8
Page 14
85-03-01115 DXV35 TIMBERFIRE Page 14
Figure 3-10
Figure 3-9
Page 15
85-03-01115 DXV35 TIMBERFIRE Page 15
Planning the installation
This Mendota Fireplace must be installed and serviced by a qualified installer, service agency, or the gas supplier.
When planning on appliance installation, it is necessary to determine the following information before installing:
Where the appliance is to be installed.
The vent system configuration to be used.
Gas supply piping.
Electrical Wiring.
Framing and finishing details.
Hearth Protection Pad Requirements.
Whether accessories such as a ceiling fan are desired.
Selecting Appliance Location
When selecting a location for your appliance, it is important to consider the required clearances to walls.
MINIMUM FRAMING DIMENSIONS
WIDTH = 36-1/4” HEIGHT = 31-7-16” DEPTH = 15-1/8”
Figure 3-11 FLAT WALL LOCATION
Figure 3-12 CORNER INSTALLATION
WARNING
FIRE RISK- ODOR RISK
Install appliance on hard metal or wood surfaces extending full width and depth of this fireplace.
An R-1 Rated Hearth Protection Pad [1-1/2” Thick Maximum] and 12” deep is required unless this fireplace is
elevated. For every 1” this fireplace is elevated, you may reduce the hearth pad depth by 2”. If this fireplace is
elevated 6” or higher no hearth protection pad is required.
Do NOT install this fireplace directly on carpeting, vinyl or any combustible material other than wood. Construct chase to all clearance specifications in manual.
Locate and install appliance to all clearance specifications in manual.
Page 16
85-03-01115 DXV35 TIMBERFIRE Page 16
Dimensions and Technical Details
DXV35 TIMBERFIRE Fireplace Ratings Information
This Mendota Fireplace can be installed directly on top of a metal, masonry or wood structural surface.
ELECTRICAL REQUIREMENTS: 120 Volts AC, 1.5 Amps (minimum line voltage allowed 110 Volts AC) REQUIRED GAS SUPPLY PRESSURE: NAT. GAS: 7" W.C. [5.0" W.C. MIN., 11" W.C. MAX.]
L.P. GAS: 11" W.C. [11" W.C. MIN., 13" W.C. MAX.]
LP GAS CONVERSION KIT: This Fireplace comes configured for use with Natural Gas. To convert the Fireplace for use with LP Gas, install: LP GAS CONVERSION KIT #HA-30-00279. GAS INPUT RATES High Fire Low Fire
BTUH .......................... NAT. GAS 33,000 21,000
BTUH .......................... L.P. GAS 33,000 18,500
ORIFICE SIZES………… [0-2000ft (610 m)]: #32 NG [50 L.P.]
P.4 FIREPLACE EFFICIENCY ..........76.35%
FLUE VENTING ............COAXIAL RIGID- 4DIAMETER EXHAUST & 6-5/8” DIAMETER AIR INLET AND APPROVED VENT CAPS
All UL Listed Coaxial Rigid 4”X6-5/8” Vent pipe components and vent caps are approved for use. Do not mix components of different brands or series. Always use the same brand and series components throughout the entire vent system.
MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION
UNIT TO FLOOR 0in. (0mm) GLASS FRAME EDGE TO ADJACENT SIDEWALL 12in. (305 mm) UNIT TO ENCLOSURE SIDEWALL 1/2in. (13mm) VENT PIPE TOP TO COMBUSTIBLES 2in. (51mm) UNIT TO ENCLOSURE BACK WALL 1/2in. (13mm) VENT PIPE SIDES TO COMBUSTIBLES 1in. (25mm) UNIT BOTTOM TO ENCLOSURE CEILING 53-3/8 in. (136 cm) VENT PIPE BOTTOM TO COMBUSTIBLES in. (25mm) UNIT BOTTOM TO ROOM CEILING 72 in. (1829 mm) DISTANCE TO 8” MANTLE ABOVE TOP CONVECTION AIR DISCHARGE OPENING 14 in. (356 mm)
MINIMUM COMBUSTIBLE ROUGH FRAMING DIMENSIONS
WIDTH = 36-1/4 (920 mm) HEIGHT = 31-7/16” (799 mm) DEPTH = 15-1/8” (384 mm)
NET WEIGHT................185 lbs. (Team Lift recommended)
BARRIER SCREEN: A barrier screen that has been certified for use with this Fireplace must be installed on the Fireplace when it
is in use. The barrier screen will prevent accidental contact with the glass door face, which could result in a severe burn.
SAFETY: AGA certified, manual spark ignition system with thermocouple safety. CERTIFIED TO: ANSI Z21.88 - 2016
This Mendota Gas Fireplace has been tested and certified by: Intertek Testing Services, 8431 Murphy Drive, Middleton, WI 53562\
ICBO#AA647-4
Page 17
85-03-01115 DXV35 TIMBERFIRE Page 17
Fireplace Features
EXTERNAL DIMENSIONS: 36-1/4 Wide X 31-7/16” High X 15-5/8” Deep MINIMUM FRAMING DIMENSIONS: 36-1/4” WIDE x 31-7/16” HIGH X 15-1/8” DEEP GLASS SIZE: NeoCeram Glass with non-reflective coating. Visible Glass measures 28-3/8” X 16-1/16”. MANTEL ALLOWANCE: 8” Deep Mantel at 14” Above Top Convection Opening (41” up from base of Unit) VENT SYSTEM ALLOWANCE: Top Vent Only. 12” Vertical Minimum with 6” max horizontal. 55 feet Vertical Maximum. 4”
exhaust and 6-5/8” combustion air intake coaxial vent pipe required. 12’ maximum horizontal run allowed with 4’ minimum vertical starter section.
VENT DAMPER ADJUSTMENT AVAILABLE: There is one exhaust vent damper included in this unit and located in the top convection chamber at the center.
CONTROLS: Thermocouple Safety System with Standing Pilot Thermopile power generator. Thermostat option available. BLOWER SYSTEM: 190 CFM Dual Blower System. 120VAC, 2Amps. Dedicated Hot Power only. No switches, Fan Speed Controls
or Light Dimmers are allowed in same circuit.
BURNER SYSTEM: Single Stainless-Steel Tubular burners. BURNER AIR SHUTTER SYSTEMS: Externally controllable Burner air shutter. LOG SET: 6-piece, Premium Definition Log Set with Extreme glow and realism. REFRACTORY PANELS: High Detail Red Clinker Fiber Brick Panels included. Brick Panels required for operation. NATURAL GAS INFORMATION: Factory equipped for Natural Gas. 4.5”WC Minimum inlet pressure required.
LPG INFORMATION: LP conversion kit #HA-30-00237 is required. 12”WC Minimum inlet pressure required. For the DXV35 Timberfire LPG application, the orifice is to be drill size #50. For higher altitude, adjustment to orifice size may be necessary.
Page 18
85-03-01115 DXV35 TIMBERFIRE Page 18
Fireplace Dimensions and Clearances
MINIMUM FRAMING DIMENSIONS
WIDTH = 36-1/4” HEIGHT = 31-7-16” DEPTH = 15-1/8”
Figure 3-13
Figure 3-14
Figure 3-15
Figure 3-16
A wall, perpendicular and in front of this appliance's glass door face must be at least 12" away from the side edges of the glass frame (Figure 3-13).
A wall at a 45 angle to the front face and starting at the Side Edge of the Front Face of this appliance is allowed. Projections behind this 45 angle edge (shaded area) are allowed.
Caution: The distance from floor level to the centerline of the vent cap is based on Simpson DuraVent GS components. If using vent components of another brand, do not assume that the measurement given here is applicable. Verify the distance to the centerline of vent cap by measuring the components you are using.
Note: For every 1” this fireplace is raised off the floor, the non-combustible hearth protection pad may be reduced by 2”. If this fireplace is raised more than 6” off the floor, no hearth protection pad is required. See Chapter 3.2.4.2 Hearth
Pad Requirement and Chapter 3.2.5.1 Hearth Pad Temperatures.
Page 19
85-03-01115 DXV35 TIMBERFIRE Page 19
Rough Framing Dimensions
The rough framing dimensions given are the minimum allowed framing dimensions. Be sure when planning the framing of the unit that adequate paths to route the gas and electrical are available on both sides of the unit.
SPECIAL FRAMING NOTE: If the fireplace is to be recessed in a cavity deeper
than 15-1/8”, all framing and finishing materials protruding past the front face of this fireplace must be of the NON-COMBUSTIBLE variety.
Minimum Required Rough Framing Dimensions
DESCRIPTION
DIMENSION (INCHES)
A
WIDTH
36-1/4
B
HEIGHT
31-7/16”
C
DEPTH
15-1/8”
E
FINISH MATERIAL THICKNESS
Varies
F
UNIT BASE TO ENCLOSURE CEILING
53-5/8”
G
GLASS FRAME EDGE TO SIDE WALL
12
H
UNIT BASE TO 8” MANTEL
41”
MINIMUM FRAMING DIMENSIONS
WIDTH = 36-1/4” HEIGHT = 31-7-16” DEPTH = 15-1/8”
Figure 3-17
Figure 3-18
If the mantel is constructed of non combustible materials, it may be placed at any distance above the top air gap.
Caution: Materials made of porous stones or sedimentary rocks may crack due to expansion of the material if placed around this appliance. Use suitable materials which are crack resistant and high temperature resistant.
Page 20
85-03-01115 DXV35 TIMBERFIRE Page 20
Constructing the Appliance Chase
A chase is a vertical box-like structure built to enclose this fireplace and its vent system. Vertical vents that run on the outside of a building may be, but are not required to be, installed inside a chase.
Construction of the chase may vary with the type of building. These instructions are not substitutes for the requirements of local building codes. Local building codes MUST be adhered to.
Chases should be constructed in the manner of all outside walls of the home to prevent cold air drafting problems. The chase should not break the outside building envelope in any manner.
Wall, ceiling, base plate and cantilever floor of the chase should be insulated. Vapor and air infiltration barriers should be installed in the chase as per regional codes for the rest of the home. Additionally, in regions where cold air infiltration may be an issue, the inside surfaces of the chase may be sheet rocked and taped for maximum air tightness.
To further prevent drafts, the fire stops should be caulked with high temperature caulk to seal the gaps. Gas line holes and other openings should be caulked with high temp caulk or stuffed with unfaced insulation. If the appliance is being installed on a cement slab, a layer of plywood may be placed underneath this fireplace to prevent conducting cold up into the room
Figure 3-19 Floor to Vent Cap Center Dimension
Page 21
85-03-01115 DXV35 TIMBERFIRE Page 21
Clearance Requirements
Clearance from Appliance Body and Vent
Figure 3-21 CLEARANCES TO VENT
The required clearances are depicted in these diagrams.
1. Minimum Clearance from fireplace body sides to combustibles is zero.
2. Minimum Clearance from fireplace top surface to combustibles is 2-1/2” or zero from top edge of top triangle
standoffs.
3. Minimum Clearance from vertical vent pipe sides to combustibles is 1”.
4. Minimum Clearance below horizontal vent pipe or components is 1”.
5. Minimum Clearance above elbows and horizontal vent pipe and components is 2”.
Figure 3-20 CLEARANCES TO BODY & VENT
Page 22
85-03-01115 DXV35 TIMBERFIRE Page 22
Hearth Pad Requirement
A non-combustible hearth protector with a thermal insulation rating of R-1 is required when installing this fireplace directly on the floor and must extend a minimum of 12" in front of this fireplace. To build an R-1 rated hearth protection pad, begin by
laying down a ½” thick layer of an R-1 rated Mineral board (see 3.2.6.3 Suitable Finishing Materials R-Ratings) and then add a 1” thick top layer of noncombustible material such as stone, granite, marble or the like.
For every 1” the fireplace is raised off the floor, th e d epth o f th e required hearth protector may b e reduced by 2”. If fireplace is raised off t he floor 6" or more, no hearth protector is required for fire protection.
Caution: The fireplace creates localized heat and causes thermal expan sion of adjacently installed flooring and wall materials. Vinyl floor s and floating Engineered wood floors may warp if installed in front of this unit even when this fireplace is raised 6” or more due to local heating up of the floor mat erial s. Never use viny l or Engineered wood flooring in the hearth pad area in front of this fireplace u nless you p lan to raise this unit 12” or more above the floor level.
Caution: Modern carpets use polypropylene, nylon or polyester fibers in the upper visible layer. These fibers when exposed to radiant heat can curl and stiffen. It is not p ossible to prev ent radiation effects to the carpet fibers even when this unit is raised high. A void in stallin g carpets in the hearth pad area in fro nt of this Fireplace unless this fireplace is raised at least 12 inch es above the carpet level .
This fireplace may be installed in an elevated position by created an elevated deck and an appropriate framed enclosure. NOTE: This fireplace may be elevated but MUST allow a minimum of 72” distance between this fireplace’s floor level and the ceiling of the room.
Figure 3-22 HEARTH PROTECTON PAD
Page 23
85-03-01115 DXV35 TIMBERFIRE Page 23
Clearances to Combustible Mantels
An 8” combustible mantel may be installed at a minimum of 14" above the top of the heat outlet (41” up from the floor level of this Fireplace). Non-combustible (marble, brick, stone, metal etc.) mantels can be installed at any desired height above the top convection air opening. Any pre-existing combustible mantel must fall within the approved mantel profile chart.
WARNING: Make proper use of this chart. Do not compromise the specifications contained in this chart. Failure to adhere to proper clearances required to combustibles may cause spontaneous combustion of the mantel and may result in a fire causing property damage, personal injury or loss of life.
NOTE: For mantels that protrude more than 8 inches from the front surface of the fireplace use a rise and run of (7:4) to calculate the required height to the mantel. EXAMPLE: You have a 12" mantel. To calculate the height above the convection air opening the equation would be: 12" x (7/4) = 21" above the convection air opening. DO NOT deviate from this minimum clearance requirement. Doing so can lead to a severe fire hazard.
Note: The distance from the Floor Level of this Fireplace to the Top Air Gap is 27”.
Figure 3-23 Mantel Clearances
Figure 3-24 Mantel Clearances
Page 24
85-03-01115 DXV35 TIMBERFIRE Page 24
Clearances to Combustible Side Walls
The minimum distance required from the side edge of the glass frame to a combustible side wall is 12”. Combustible side walls, mantel corbels, mantel legs and other combustible walls and decorative objects must fall behind a 45­degree line extending outward from the side edges of the visible glass unless such objects are more than 12” away from the side edges of the glass frame. See Figure
3-25 Side Wall Clearances.
A wall, perpendicular and in front of this appliance's glass door face must be at least 12" away from the side edges of the glass frame.
A wall at a 45o angle to the front face and starting at the Side Edge of the Front Face of this appliance is allowed. Projections behind this 45o angle edge (shaded area) are allowed.
If the required clearance cannot be met to a pre-existing co mbu st ible side wall, an NFPA approved clearance redu ction shield, metal or ceramic boa rd, must be added to th e sid e wall.
3.2.4.4.1 Horizontal Clearance Reduction by 66%
NPFA 211 Approved: Install 20-gauge or heavier steel shield that provides at least a 1” active airspace, on the combustible wall
surface. To provide for active airflow, install at least 1” metal or ceramic standoffs or spacers between the metal shield and the combustible surface being protected. The bottom and top edges of the cavity between the metal shield and the combustible surface must be left open. The steel shield must be a minimum of 12” larger in each direction than the surface area of the source of heat; or if the surface being protected is smaller than surface area of the source of heat, this shield must be larger than the combustible surface in each direction. By using this method of protection, if the required horizontal clearance was 12”, the resulting clearance will be reduced by 66% to 4” between the heat source and the metal shield.
3.2.4.4.2 Horizontal Clearance Reduction by 50%
NPFA 211 Approved: Install an R-1 rated ceramic board or R-1 rated mineral board on the wall you are attempting to protect.
by using this method of protection, if the required horizontal clearance was 12, the resulting clearance will be reduced by 50% to 6” between the heat source and the R-1 Rated wall board.
Figure 3-25 Side Wall Clearances
Page 25
85-03-01115 DXV35 TIMBERFIRE Page 25
Normal Surface Temperatures
WARNING: The supplied barrier screen must be installed, always, when this fireplace is in operation. Do not plac e any object directly in front (within 60” from barrier screen surface) or directly above (on the front edge of the mantel). This is a heat ing appliance. Areas directly in front and above this appliance will be very hot and can damage most house hold objects if placed too close. Keep Furniture piece s at least 60” away in front of the barrier screen surface.
HINT: To greatly reduce surface temperatures surr ounding th is Fireplace during operation, Mendota recommends operating the integrated convect ion air blowers which aid in cool ing all surroundin g surfaces.
Mendota Fireplaces comply with ANSI Z21.88-2016 Standards for maximum surface temperatures (ambient plus 117oF) on exposed “combustible” surfaces adjacent to the Fireplace.
Be aware that surfaces in front of, above and adjacent to this heater appliance can be too hot to touch. As long as all required clearances to combustibles are met and the required finishing materials are used, this appliance will perform safely. Note that the exposed surfaces immediately surrounding the Fireplace can have surface temperatures that are too hot to touch. This level of surface temperature is considered normal and does not indicate any hazardous situation.
Hearth Pad Temperatures
New hearth protection pads installed are required to have a thermal insulation value of R-1. The top exposed surface of the noncombustible hearth pads can reach a temperature that is too hot to touch (as high as 250oF). This is considered normal.
Surround Face Temperatures
Areas of the breastplate directly above the top convection air gap of this Fireplace can be very hot (too hot to touch(exceeding 250oF)) and is deemed normal.
Mantel Temperatures
Mendota Fireplaces comply with ANSI Z21.88-2016 standards for maximum surface temperatures on
exposed “combustible” surfaces adjacent to the
Fireplace. Be aware that surface in front of, above and adjacent to this heater appliance can be too hot to touch. As long as all required clearances to combustibles are met and the required finishing materials are used, this appliance will perform safely. Note that the exposed surfaces immediately surrounding the Fireplace can have a surface temperature too hot to touch. This level of surface temperatures is considered normal and does not indicate any hazardous situation.
WARNING: Surfaces surrounding this Fireplace can be very hot to the touch during operation. Carefully supervise children and pets while this Fireplace is operating.
Suitable Mantel, Facing & Hearth Pad Materials
Use of ceramic glazed tiles as facing materials around a Mendota Fireplace is approved. Use caution when selecting tile adhesives. Avoid premixed tile adhesives which contain products that can off gas for long periods when exposed to heat. Use Portland cement based unmixed tile adhesives or RTV Silicone to attach ceramic glazed tiles as facing in hot areas around this Fireplace. If using RTV silicone apply in long wavy lines and allow a minimum 48 hours cure time for the silicone to cure before firing this Fireplace after tile application.
Figure 3-26 Hot Zones
Page 26
85-03-01115 DXV35 TIMBERFIRE Page 26
Marble, Granite and Natural Stones
Marble, granite and other natural stone products are approved for use as mantel, facing and hearth pad materials with the following limitations and understanding of these cautionary statements:
Never use a one-piece marble, granite or n atural stone that is water jet or mechanically cut in a U -shape as fac ing material to cover the sides and top ar eas around this product. Doing so can lead to crack formation at the inner corners of the U shape du e to thermal expansion.
Figure 3-27 Three Piece Stone
Most marble slabs and marble tiles contain a polyester resin coating while most granite slabs and granite tiles contain epoxy resin coatings. The polyester resin coatings and the epoxy resin coatings provide structural strength to the stone slabs and prevent cracking, chipping and breakage during shipping and handling. These coatings also provide a glossy or satin surface finish and help seal the stone surface.
Th e poly ester resin used on marble slabs can discolor when expo sed to temperatures greater than 150oF and will structurally fail at temperatures abo ve 230oF. The epoxy resin coating used on granite slab s are resistant to discoloring and structural failures up to 350oF.Mendota does not assume any liab ili ty fo r discoloring, flaking or cracking of marble or granite.
Temperatures on facings around Mendota Gas Fireplaces can reach 350oF directly outside the top convection air gap and as high as 210oF at the maximum allowed mantel protrusion level above the top convection air gap. These temperatures can discolor polyester resin coated marble facings and can cause the polyester resin coating to fail near the top convection air gap.
Mendota Fireplace cannot guaran tee suitability of use of any marble slabs or tiles that have a polyester resin coating applied to it and cannot guarantee against discolo ration or stru ctural failure of marble or polished stone facings that have a polyester resin coating. Consu lt with your local stone supplier.
Prior to use of any marble, granite or polished stone facing material, especially white colored ones, run heat exposure tests on a sample piece. Expose sample pieces to temperatures between 275oF and 350oF for a period of eight hours. Compare the heat exposed sample to a control unheated piece and judge for color changes. Do not use if any color changes are evident.
Mendota recommends the use of honed bare marble and bar e ston e facing materials or honed bare granite and epoxy resin coated granite only.
Mendota cautions that due to natural structural defects that can exist within marble and stone pieces, cracking and/or flaking of the marble or stone is possible and must be considered prior to selection and application around Mendota Fireplaces. Mendota further cautions that proper adhesives be used to attach stone facings. Pay attention to the potential of off-gassing of chemical vapors from mastic and other adhesives. Improper selection can lead to emission of chemicals with unwanted smells.
Figure 3-28 Top Air Gap
Page 27
85-03-01115 DXV35 TIMBERFIRE Page 27
Suitable Backer Materials R-Ratings
R-Values of common Backer Materials
Material
Thickness
R-Value
Mineral Fiber Board ( Micore 160)
1/2"
1.270
Mineral Fiber Board (Micore 300)
1/2"
1.030
Mineral Fiber Board (Micor SB)
1/2"
1.470
Cearmic Board (Rescor 360)
1/2"
1.110
Cearmic Board (Fiberfrax Duraboard LD)
1/2"
1.100
Skamolex (475, 600, 700, VIP-12, HD)
1”
0.410
Promat Promafour
1”
0.410
Gypsum or Plaster Board
1/2"
0.450
Cement Board (Hardibacker 500)
1/2"
0.200
Cement Board (Hardibacker)
1/4"
0.130
Common Brick
2-1/4"
0.450
Common Brick
4"
0.800
Suitable Finishing Materials R-Ratings
R-Values of Common Facing Materials
Material
Thickness
R-Value
Cement Mortar
1/2"
0.100
Concrete
1"
0.095
Ceramic Tile
1/4"
0.020
Flagstone
1"
0.079
Granite
1"
0.083
Limestone
1"
0.153
Marble
1"
0.090
Sandstone
1"
0.079
Slate
1"
0.100
Page 28
85-03-01115 DXV35 TIMBERFIRE Page 28
Suitable Paints and Sealant Materials
3.2.6.4.1 Paint Types Approved for Use
Industrial Acrylic Paints, Alkyd based Paints. When selecting paint for applications on facings, mantels, corbels or floors within
2’ in front of a fireplace raised 6” or higher, avoid off the shelf paints which may have modifier additives used to increase “hiding” ability, accelerate drying times and curing times. Consult with a reputable paints and sealants supplier and acquire
industrial acrylic paints or alkyd-based paints.
3.2.6.4.2 Sealants Type Approved for Use
Heat resistant polyurethane sealants which are not damaged by prolonged exposure to raised temperatures. Many are flame resistant, meaning that they resist ignition when exposed to high temperatures and can insulate the substrate and delay damage to it. When selecting polyurethane for applications on facings, mantels, corbels or floors within 3’ in front of or above a fireplace, avoid off the shelf urethane sealants which may have modifier additives used to accelerate drying times and curing times. Consult with a reputable paints and sealants supplier and acquire heat resistant polyurethane sealants.
3.2.6.4.3 Wood Application Cautions
If wood used around or in front of the fireplace has been chemically cleaned or bleached prior to staining or painting, it is of the utmost importance to make certain that the cleaner or bleach does not remain in the wood substrate under the final paint or sealant applied. If any cleaner or bleach remain within the wood structure, application of heat from the fireplace, even low-level heat, will cause the cleaner or bleach compounds to expand or evaporate causing separation of the paint or sealant from the wood surface and may cause peeling or bubbling of the paint or sealant. Moisture content of the wood substrate is also of critical importance. High moisture content wood when heated will yield evaporation of the moisture and hydraulic pressure under the paint or sealants which can lead to peeling or bubbling. Always select the lowest moisture content wood substrate.
Page 29
85-03-01115 DXV35 TIMBERFIRE Page 29
Recommendations for Television Installation
Note: The model depicted in the images is a representation of a Mendota Hearth fireplace. These recommendations apply to all
Mendota Hearth Fireplaces. When planning to install a television or other heat sensitive product above your fireplace, there are some points to consider. Many television manufacturers specify in their installation instructions that the television must not be installed near or above a
heat source. The decision to install a television near or above a Mendota fireplace rests solely on the consumer. It is the consumers responsibility to satisfy television specifications and insure the television will not exceed maximum operation temperatures. Mendota Hearth will not be held liable for any adverse effects on a television or other products located near to a Mendota Hearth fireplace.
The drawings below show recommendations that may be used as a guide for those consumers that decide to locate a television above a Mendota Hearth fireplace. These recommendations have been found to reduce the heat impact to a television when installed above a Mendota Hearth fireplace.
Recommendation 1: Add a mantel
Add a mantel above the fireplace. The mantel shall be at least 2 inches deeper than the depth of the television, and at least as wide as the television. The mantel shall be mounted so that its top surface is a minimum of 18 inches above the top air gap of the fireplace.
Attention: If the mantel is constructed of combustible materials, make certain that the entire mantel meets the clearances to combustible mantel requirements.
Page 30
85-03-01115 DXV35 TIMBERFIRE Page 30
Recommendation 2: Create a recessed cavity
Frame a recessed cavity above the fireplace. The cavity shall be at least 6 inches taller and 6 inches wider than the television. The cavity’s bottom surface must be a minimum of 24 inches above the top air gap of this fireplace. The cavity must be deep enough for the television to be recessed at least 2 inches in from the wall.
Recommendation 3: Install a heat transfer system
Mendota Hearth offers three heat transfer systems that take heat from the fireplace and redirect it to another area. When used correctly these heat transfer systems can make it possible to mount a television above the fireplace without installing a mantel or creating a recessed cavity.
Note: Heat transfer systems are not available for use on M27 model fireplaces. WARNING: The convection fans on the fireplace must be turned off to insure the heat from the fireplace is redirected through the
heat transfer system. Turning the convection fans on will force heated air out the front of the fireplace, heating the surrounding area.
- On fireplaces with a millivolt system: DXV35 Timberfire, DXV42, DXV60, M50 the convection fans must be disconnected
from power to insure they cannot be turned on.
Page 31
85-03-01115 DXV35 TIMBERFIRE Page 31
- On fireplaces with electronic ignition system that come with a PF2 remote the convection fans function must be
programed out of the remote. This will ensure that the convection fans cannot be turned on. Follow the directions below to remove the convection fans function from the remote.
1. Remove a battery from the remote.
2. Hold down both the ON/OFF key and MODE key
and reinstall the battery.
3. Continue to hold the ON/OFF key. Release the
MODE key. Press the MODE key once to highlight the convection fan function.
4. While still holding the ON/OFF key press the DOWN
ARROW key. The display will change from “Set” to “Clr” to indicate that the convection fan function
has been disabled.
5. Release the ON/OFF key.
3.2.7.3.1 Mendota Cool Wall
The Mendota Cool Wall system uses natural convection to take heat off the wall directly above the fireplace and redirects it up and away from surrounding areas. Testing has shown that when using a Cool Wall system, temperatures above the fireplace are reduced making it possible to mount a television 15” above the fireplace’s top air gap.
Page 32
85-03-01115 DXV35 TIMBERFIRE Page 32
3.2.7.3.2 Versiheat
The Versiheat system uses a fan to redirect heat from the fireplace to an alternate room in the home. WARNING: To reduce temperatures above the fireplace for mounting a television the Versiheat system must always be on when the fireplace is in operation. Because the Versiheat system must be running to reduce temperatures the fireplace cannot be operated during a power outage. Testing has shown that when using two Versiheat systems temperatures above the fireplace are reduced making it possible to mount a television 15” above the fireplace’s top air gap.
Page 33
85-03-01115 DXV35 TIMBERFIRE Page 33
3.2.7.3.3 FlexHeat
The FlexHeat system uses two inline fans to redirect heat from the fireplace outside the home or to an alternate room in the home. WARNING: To reduce temperatures above the fireplace for mounting a television the FlexHeat system must always be on when the fireplace is in operation. Because the FLexHeat system must be running to reduce temperatures the fireplace cannot be operated during a power outage. Testing has shown that when using the FlexHeat system temperatures above the fireplace are reduced making it possible to mount a television 12” above the fireplace’s top air gap.
Page 34
85-03-01115 DXV35 TIMBERFIRE Page 34
Venting
Th e DXV35 TIMBERFIRE Fireplace must be vented to the outside and mu st u se one of the approved coaxial rigid ducting systems or a coaxial flexible ductin g sy st em. Do Not Use any silicone sealants at pipe
joints. Stove gasket cements may be used at pipe joints but is not required .
The DXV35 TIMBERFIRE Fireplaces requires coaxial rigid- 4” diameter exhaust & 6-5/8” diameter air inlet and approved vent caps for most installations. In some special cases, flexible ducting may be used. Contact Mendota Technical Service Department if your installation requires other than standard rigid 4” X 6-5/8” Coaxial venting components. All UL Listed Coaxial Rigid 4”X6-5/8” Vent pipe components and vent caps are approved for use. Do not mix components of different brands or series. Always use the same brand and series components throughout the entire vent system.
All wa rranties will be voided and serious fire, health or oth er safety haz ards may result from any of the fol lo win g act ions: Installation by unauthorized personnel; installation of any damaged component; unauthorized modification of vent system; i nstallation of any co mpon ents not approved by Mendota; failure to meet all clearance requirements; failure to pro perly twist -lock and positively seal all components. Consult local building codes before beginning the installation .
WARN ING: Always maintain r equired cl earan ces (air spaces) to combustibles to prevent a fire hazard. Do not fill air spaces with insulation. Check installation in stru ction s for minimum clearance requirements between the outer walls of the vent pipe and nearby combustible surfaces . Be sure to ch eck the vent ter min ation clearance requirements from decks, windows, so ffit, ga s r egu lators, air supply inlets, and public wal kways, as specified in these installation instructions and loca l bui ldin g codes.
SAFETY PRECAUTIONS FOR THE INSTALLER: 1) Wear gloves and safety glasses for protection; 2) Exercise extreme caution when using ladders or on rooftops; and 3) be aware of electrical wiring locations in walls and ceilings.
This gas appliance and vent system must be vented directly to th e outside of the building, and never attached to a chimney serving another solid fuel or ga s burn ing appliance. Each direct vent gas appliance must have its own separate vent system. Common vent sy st ems are proh ibited.
To a ssure proper venting per forman ce of this high-performance Mendota Direct Vent Fireplace, it is critical that all brand s of vent pipe sect ions are sealed tightly and leak -proof. This means that all pipe sect ions must be carefully rotated into the fully "twist -locked " po sition .
We strongly recommend that fixed length pipe sections be used in place of telescoping sections whenever possible.
COMPONENT "TWIST-LOCK" CONNECTION PROCEDURE
DuraVent and American Metals pipe and fittings are designed with special twist-lock connections. Twist-lock procedure is as follows: four (4) indentations, located on the female ends of pipes and fittings are designed to slide straight in to the male ends of the adjacent pipes and fittings, by orienting the four pipe indentations so that they match and slide into the four entry slots on the male ends. Push the pipe sections completely together then twist-lock one section clockwise, approximately ¼ turn until the two sections are fully locked. The female locking lugs will not be visible from the outside on the black pipe or fittings. They may be located by examining inside of the female ends.
Wall Heat Shield for Horizontal Vent Caps
Always use heat shield (#AA-11-00458) when the exterior wall covering is made of vinyl, wood or other combustible materials. Heat shield (#AA-11-00458) or an equivalent heat shield shall be installed. Heat shield (#AA-11-00458) is available for order directly from Mendota fireplaces.
HEAT SHIELD #AA-11-00458
Page 35
85-03-01115 DXV35 TIMBERFIRE Page 35
Flue Venting Components Identification Diagrams
Prior to installing at altitudes higher than 7500, please contact the Mendota technical service department for specific venting requirements and venting restrictions.
ITEM
DESCRIPTION
1
6" or 7” PIPE (DuraVent 6”/Amerivent 7”), 9”, 12”
2
12" VENT STACK
3
24" VENT STACK
4
36" VENT STACK
5
48" VENT STACK
6
90ºGALVANIZED ELBOW
6a
45º GALVANIZED ELBOW
7
ADJUSTABLE WALL THIMBLE
8
ATTIC INSULATION SHIELD 12"
9
ROOF FLASHING (0/12 TO 6/12)
10
ROOF FLASHING (7/12 TO 12/12)
11
STORM COLLAR
12
VERTICAL VENT CAP
13
SUPPORT BAND
14
HORIZONTAL VENT CAP
15
FIRE STOP SPACER
1,2,3,4,5
13
15
9,10
11
12
Page 36
85-03-01115 DXV35 TIMBERFIRE Page 36
Approved Vent Systems
Figure 3-29 Approved Vent Systems
Page 37
85-03-01115 DXV35 TIMBERFIRE Page 37
Exterior Vent Locations and Restrictions
Note: All measurements are to be taken from the center of the vent cap.
- Vent Terminal
X - Air Supply Inlet
 - Area where terminal is not permitted
A = Clearance above grade, veranda, porch, deck, or balcony (*18 inches (45 cm) minimum)
H = *Not to be installed above a meter/regulator assembly within 3 feet (90 cm) horizontally from the center-line of the regulator; within a height of 15 feet
B = Clearance to window or door that may be opened (*18 inches (45 cm) minimum.
I =
*Clearance to service regulator vent outlet *3 feet (92 cm) minimum.
C = *Clearance to permanently closed window (minimum 18 inches (45 cm) recommended to prevent condensation on window)
J =
*Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance. 12 inches (30 cm) minimum.
D = *Vertical clearance to ventilated soffit located above the terminal from the center-line of the terminal 18” (45 cm) min. Minimum 24” (60 cm to Vinyl Soffit)
K = *Clearance to a mechanical air supply inlet In USA, 3 feet minimum above, if within 10 feet
horizontally. In Canada, 6 feet minimum
E = *Clearance to unventilated soffit 18” min (45 cm) min. Minimum 24” (60 cm to Vinyl Soffit)
L = Clearance above paved side-walk or a paved driveway located on public property (*7 feet (2.1 m) minimum)
F =
Clearance to outside corner - 12 inches (30 cm).
M = Clearance under veranda, porch, deck, or balcony (*18 inches (45 cm) minimum )
G = Clearance to inside corner - 12 inches (30 cm). Vinyl surfaces require 24” min (60 cm).
N=
Minimum 24” horizontal clearance to any surface,
such as an exterior surface, for vertical terminations.
Page 38
85-03-01115 DXV35 TIMBERFIRE Page 38
Side by Side installation of two Vent Caps
When two or more vertical vent caps are located within proximity of one another, it is required that a galvanized steel 18-gauge or heavier barrier wall be installed between the two vent caps to eliminate recirculation of exhaust gases from one cap to another. The galvanized steel barrier shall be 6" taller than the highest point of the vent caps and shall be 3" wider past the outer edges of the vent caps. If two gravity direct vent system gas appliances are terminated next to each other, the minimum required distance between the vertical center line of the vent caps is 18” to prevent recirculation of exhaust from one vent cap outlet into the air intake of another vent cap. If a wood burning flue opening is adjacent to a gravity direct vent system gas appliance vent cap and the distance between vertical center lines of the two terminations is less than 36”, we recommend a metal divider plate be installed to prevent wood burning exhaust from entering the gas appliance air intake path. Alternatively, you may also vertically extend the wood burning flue liner up 24” higher than the top surface of the gas appliance vent cap.
Figure 3-30 Side by Side Vent Caps
Page 39
85-03-01115 DXV35 TIMBERFIRE Page 39
Decorative Cover for Vent Cap
It is acceptable to install a decorative stone, metal or terra cotta cover to disguise the vent terminal/cap used on Mendota Fireplaces if the decorative cover meets the following minimum requirements:
1. The decorative cover shall be manufactured from noncombustible materials.
2. The decorative cover shall provide a minimum of 3” clearance from the outer surface of the vent cap to the inner walls
of the decorative cover on sides all of the vent cap.
3. Fresh air openings shall be provided at a level equal to or below the fresh air openings in the vent cap. The fresh air
openings shall provide a minimum open area of 60 square inches. This fresh air opening area shall be broken into at least two equal openings (or more if possible). Each opening shall have a minimum height of 2” and a length that provides the required opening to yield a total of 60 square inches, minimum.
4. The fresh air openings shall be protected in a manner that prevents the accumulation of snow which can plug the fresh
air openings.
Examples of Decorative Covers for Vent Caps
Figure 3-31 Decorative Covers
Page 40
85-03-01115 DXV35 TIMBERFIRE Page 40
3.3 ELECTRICAL TECHNICAL REFERENCES
AC Power Requirements
WARNING: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
For normal operation, this appliance requires 120 VAC, 2 Amp po wer or a 6V DC power source. The AC power supply to this Fireplace must be hot at all times and shall not have a switch installed in it.
This appliance is equipped with an electrical junction box on the left side.
Planning for AC Power Connection
On the left-side of this appliance, you will find an electrical junction box with a strain relief clamp. To connect AC power to this Fireplace, follow these steps:
1. Remove the junction box cover plate (secured
with two screws), route the 3wire end of an extension cord or house power wire cable through the strain relief in the cover plate.
2. Strip the ends of the house power wires and the
three color coded wires within the junction box. Connect each color-coded wire to corresponding colored wires within the junction box. Use the supplied wire nuts to connect each wire pair ends.
Note: When connecting two braided wires using wire nuts, strip both braided wire ends
at least ½” and twist the two bare ends together before using wire nuts. When connecting a braided wire to a solid copper wire, strip the solid copper wire end ½” and
the braided wire end ¾”. Twist the braided wire around the solid copper wire end before applying the wire nut.
3. Place connected wire ends within junction box then close and secure the junction box cover plate.
AC Power Connection
Figure 3-32 Electrical Junction Box
STEP 1
Figure 3-33 Wire Connections
STEP 2
STEP 3
Page 41
85-03-01115 DXV35 TIMBERFIRE Page 41
OPERATING DURING POWER OUTAGES
This ignition system utilizes thermocouple and thermopile power for pilot and burner ignition functions. AC power is utilized for blower function only. If the AC power is interrupted during a power outage, you may operate this fireplace for one continuous hour on and one continuous hour off cycles only.
During the power outage, the appliance’s burners will function. In addition, Flame Height adjustment function will be available. The Fan, which is wholly dependent on 110VAC power, will not function.
Wall Thermostat System Diagram
RECOMMENDED MAXIMUM
LEAD LENGTH (TWO-WIRE)
WHEN USING WALL THERMOSTAT
(CP-2 SYSTEM)
WIRE SIZE
MAX. LENGTH
14 GA.
100 FT.
16 GA.
64 FT.
18 GA.
40 FT.
20 GA.
25 FT.
22 GA.
18 FT.
Note: Connect wires in junction box located on the left side of this appliance to house power using supplied wire nuts.
Replacement wires must have the same type and size of insulation as the original.
This appliance must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current NFPA 70­National Electric Code or CSA C22.1- Canadian Electrical Code. Label all wires prior to disconnection when servicing control. Wiring Errors can cause improper and dangerous operation. Verify proper operation after servicing.
Figure 3-34 Thermostat Wiring Diagram
Page 42
85-03-01115 DXV35 TIMBERFIRE Page 42
3.4 PLUMBING TECHNICAL REFERENCES
Gas Supply Requirements
NOTE : If Fireplace is to b e op erat ed with LP gas, see Chapter 4.3 Natural Gas to LPG Conversion in this manua l before proceeding.
CORRECT GAS PRESSURE AND PROPER GAS SUPPLY LINE SIZING IS IMPERATIVE TO THE SUCCESSFUL PERFORMANCE OF YOUR MENDOTA GAS FIREPLACE. BE SURE THE GAS SUPPLIER OR PLUMBER CAREFULLY CHECKS FOR CORRECT GAS PRESSURE AND GAS LINE SIZING WHEN INSTALLING THE FIREPLACE.
IT IS CRITICAL TO CAREFULLY CHECK FOR GAS LEAKS WHEN HOOKING UP THE FIREPLACE. CHECK WITH SOAP AND WATER SOLUTION OR COMBUSTIBLE GAS SNIFFER.
BE SURE TO INSTALL CSST FLEX GAS LINE WITH BRASS-TO-BRASS FITTINGS TO PREVENT GAS LEAKS AT CONNECTIONS.
GAS SUPPLY PIPING MUST INCLUDE A DRIP LEG TO ELIMINATE THE POSSIBILITY OF CONTAMINANTS ENTERING THE GAS TRAIN. ADHERE STRICTLY TO LOCAL AND NATIONAL CODES.
Gas Supply Line Sizing
This Mendota Gas Fireplace comes equipped with a 1/2" N.P.T. Female inlet. Gas supply piping must enter the Fireplace cabinet on the left side.
Use the table, below, to determine the proper gas line diameter that must be installed to run from the supply regulator to the inlet end of the main gas valve. Refer to the following table for proper gas pipe diameters.
PIPE LENGTH
[FEET]
SCHEDULE 40 PIPE
INSIDE DIA.
TUBING, TYPE L
OUTSIDE DIAMETER
NAT.
L.P.
NAT.
L.P.
0-10
1/2" [1.3 cm]
3/8" [1.0 cm]
1/2" [1.3 cm] 3
/8" [1.0 cm]
10-40
1/2" [1.3 cm]
1/2" [1.3 cm]
5/8" [1.6 cm] 1
/2" [1.3 cm]
40-100
1/2" [1.3 cm]
1/2" [1.3 cm]
3/4" [2.0 cm] 1
/2" [1.3 cm]
100-150
3/4" [2.0 cm]
1/2" [1.3 cm]
7/8" [2.3 cm] 5
/8" [1.6 cm]
150-200
3/4" [2.0 cm]
1/2" [1.3 cm]
7/8" [2.3 cm] 3
/4" [2.0 cm]
NOTE: Some areas allow copper tubing or galvanized pipe - check with local approval agencies and codes NEVER use plastic
pipe.
Figure 3-35 Gas Pressure Test Ports
Page 43
85-03-01115 DXV35 TIMBERFIRE Page 43
Gas Pressure Requirements and Checking
Two pressure taps for checking input and output gas pressures are located on the main gas valve. A qualified installer should use this fitting for setting the correct gas pressure during initial installation.
Th e appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
Th e appliance must be isolated from the gas suppl y piping sy stem by closing its equipment shut -off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
Drip Leg Requirement
A drip leg/ sediment trap must be installed within the main gas supply line serving this appliance.
Figure 3-37 Drip Leg/ Sediment Trap
Manual Gas Shutoff Valve Requirement
If local building codes require one, obtain an external keyed wall-mounted or floor-mounted manual gas shutoff valve approved per local gas plumbing codes and install per local gas plumbing codes in the specified location. Local requirements supersede all other codes.
Figure 3-36 Main Gas Valve
Figure 3-38 Keyed Manual Gas Shutoff Valve
Page 44
85-03-01115 DXV35 TIMBERFIRE Page 44
Factory Installed Manual Gas Shutoff Valve
A manual gas shutoff valve is factory installed and located in the lower convection chamber. To operate the manual gas shutoff valve, rotate the red shutoff handle clockwise to open and counterclockwise to close.
Gas Inlet Fittings Information
Caution: Before you run the gas line, read, understand and properly calculate the required gas lin e si ze. Impr oper (too small) gas line size application can lead to improper burner ignition and can cause property damage and/or injury. If you are not qualified or c ert ified to run a gas line, do not proceed. Contact a qualified Gas Plumber.
The gas inlet fitting supplied with this Fireplace provides a 3/8female NPT fitting. This requires you to supply a 3/8” NPT male fitting for connection to this appliance. Based on the gas line size you have selected use an appropriate NPT fitting to adapt and connect to the 3/8” male NPT flex end adapter.
Page 45
85-03-01115 DXV35 TIMBERFIRE Page 45
Gas Input Rate Verification
Natural Gas Input Rate Verification
1. Verify main orifice size. The main orifice body has the orifice hole size stamped on it. NG orifice size shall be #32
for all elevations.
2. Verify that the Manifold Gas Pressure is within 3.5" WC +/- 1/8". Once setup, read the main home gas supply
meter reading.
3. Write the initial reading here >> initial gas meter reading
Turn off all other appliances and their pilot flame in the home.
4. Run this appliance for a period of 30 minutes on maximum flame size. Turn off main burner and pilot
flame. Read the main home gas supply meter reading after the 30 minutes of burn time.
5. Write the reading here >> final gas meter reading
Calculate the following:
6. FINAL GAS METER READING - INITIAL GAS METER READING...Subtract initial gas meter from final gas meter
reading. This will yield the number of Therms used during the 30-minute burn time.
7. Multiply the result in Item #6 by 100,000.
8. Multiply the result in Item #7 by 2. Write down the result here >>
9. The result in item #8 shall be at least the maximum input rate (33,000 Btu/hr.) for all altitudes.
LPG Input Rate Verification
Verify main orifice size. The main orifice body has the orifice hole size stamped on it. LPG orifice size shall be #50 for all elevations.
Verify that the manifold gas pressure is within 10.0" WC +/- 1/8".
High Altitude De-Rating
If you are de-rating this appliance at a high altitude, attach the High Altitude De-Rating Label, supplied in the Owner’s Manual Packet, to the back surface of the listing label plate located in the air gap on the side of the Fireplace. If you are also converting the Fireplace for LP Gas attach the labels included with the conversion kit to the same surface. Prior to attaching the label, fill in all the information that is requested on the label.
For installations from 610-1370 meters (2000-4500 ft.) the orifice size (DMS) for Natural Gas is #32 and Propane Gas is #50, respectively. See data plate for additional information. For high altitude installations consult the local gas distributor or the authority having jurisdiction for proper rating methods. If the installer must convert the unit to adjust for varying altitudes, the information sticker must be filled out by the installer and adhered to the appliance at the time of conversion."
This appliance has been converted for use at an altitude of:
Orifice size:
Manifold Pressure:
Input (Btu/h):
Fuel Type:
Date of conversion:
Converted by:
Cet appreeil a été converti au ____ Injecteur ________ Pression à la tubulure d'alimentation _____________ Déoit calorifique ______________
Page 46
85-03-01115 DXV35 TIMBERFIRE Page 46
INSTALLATION INSTRUCTIONS
4.1 INSTALLATION CHECKLIST
The instructions provided in this chapter are arranged in the sequence of occurrences. This installation checklist is supplied as a guide for installers to follow step by step. As you complete each step of the installation
work, check mark the completed work item in the list, below. All items in this installation checklist must be completed. When all work is complete, fill in your name and the date this installation was completed.
Unpack the Fireplace body. Open and inspect the Manual Packet. Unbolt the Fireplace body from the wooden pallet. If planning to burn LPG, perform the NG to LPG conversion work. Bend up the shipping clips. Place Fireplace body inside Framed Chase, level and plumb fireplace body and secure to framing studs. Open the Fireplace Glass Door. Measure chimney Length required. Install Vent System.
Sealant is not required at vent joints. Do not use silicone sealants in vent connection joints anywhere. Adjust vent damper to match vertical chimney length. See 4.4.1 Vent Damper Adjustments Co-axial vent rigid pipe, wall vent cap or roof vent cap is installed by a Mendota approved
serviceperson in accordance with instructions.
All joints are secured, "twist-locked" and leak-proof. Horizontal or vertical vent cap is installed "right-side-up" and tightly sealed to structure per
instructions. Vent Caps are Mendota approved.
Proper exterior and interior clearances for vent systems and locations for wall vent cap/roof vent cap
are maintained.
Correct gas pressure, proper size gas lines and gas leaks are checked. 120 V electrical service and gas supply is installed in accordance with instructions and local and
national codes.
Telescoping sections are not separated. They were used as complete assemblies.
Connect Gas Supply to the Fireplace. Verify that gas pressures are proper and perform a complete leak test of all field
installed gas joints and factory installed gas train joints using a gas sniffer.
Verify orifice size.
Verify gas input rates. Connect Electrical Supply to the Fireplace. See 3.3.1.2 AC Power Connection . Install firebox inner liner kit. Follow instruction supplied with the Liner Kit. Install log set, coals and inswool media.
Install Glass door and assure that it is in proper closed position and centered in firebox opening.
Test fire Fireplace. Teach consumer how to use all functions of this Fireplace Complete warranty registration at http://mendotahearth.com/gas-fireplace-and-stove-registration.php
This installation was performed and completed by:
Date:
Page 47
85-03-01115 DXV35 TIMBERFIRE Page 47
4.2 PREPARING FOR INSTALLATION
Unpacking the Fireplace
The Fireplace arrives from the factory on a wooden pallet with a cardboard box encasing the pallet and Fireplace. To remove the outer box, identify and remove four Philips head drywall screws that secure a cardboard L pincher at the bottom of each corner of the box. Lift the outer box vertically straight upward until lower edge of the box clears the top of the unit body. Set the box aside. Mendota recommends recycling the outer box.
Figure 4-1 Outer Box Removal
Page 48
85-03-01115 DXV35 TIMBERFIRE Page 48
Contents of the Manual Packet
Once the outer box is removed, you will find the Fireplace body and a manual packet. This manual packet includes the items shown in the table, below. Contact Mendota Technical Service if any parts are missing.
Owner’s Manual. Must Leave with Homeowner.
This Manual
Figure 4-2 Manual Packet Contents
What is not included with this Appliance?
Decorative fronts are not included with this base Fireplace product. One of many decorative fronts options must be selected and purchased separately.
Unbolting Fireplace from Pallet
The Fireplace body is bolted to the pallet top surface using 5/16” X 1” Lag Screws in three points. One on each side and one or more at the rear. Use a 1/2socket and wrench to remove the lag screws and detach fireplace from the pallet top.
Figure 4-3 Unbolting Unit from Pallet
Page 49
85-03-01115 DXV35 TIMBERFIRE Page 49
Bending up the shipping clips
Once the unit is detached from the pallet by removing the securing lag screws that hold these shipping clips to the pallet, either bend these clips up 90-degrees or break them off using a screw driver and back and forth cold working motion (see below). A bending relief is provided within the clip to ease bending or breaking. Bending the shipping clips up or removing them will be necessary for Fireplace units which are to be installed in narrow width or shallow depth openings. To bend the clips up or to break them off, follow these procedures:
1. Insert the tip of a flat screw driver (longer screw driver is better) under the clip.
2. Lift screw driver handle upwards and bend the clip up about 45-degrees.
3. Remove screw driver. Insert screw driver tip into one hole in clip. Lift screw driver up. To break clip off, repeat up down
motion of screw driver seven to eight times.
Figure 4-4 Shipping Clip
STEP 1 & STEP 2
Figure 4-5 Bend Up Clip 1
STEP 3
Figure 4-6 Bend Up Clip 2
Page 50
85-03-01115 DXV35 TIMBERFIRE Page 50
How to Remove Door
1. Place both thumbs on lower doorframe directly above Spring Loaded Door Holding Bar.
2. Reach fingers under Bar and pull Bar straight out from Fireplace front.
3. Pull Bar down and move Bar inward until Bar clears doorframe - then release.
4. Repeat procedure for opposite Holding Bar.
5. Carefully lift door straight up until doorframe "clears" the 3 Door Holding Tabs on top of firebox.
6. Pull door directly out from firebox front Door is now free from unit.
NOTE : Always check glass gasket condition and gasket seal any time the gla ss door is removed and when reinstalling glass door.
How To Replace Door
1. Center door in firebox
opening. Move door inward until the 3 slots on doorframe are directly above
2. the 3 Door Holding
Tabs on firebox top.
3. Lower door so the 3
Tabs on firebox top fit through the 3 slots on the doorframe. (i.e. "Hang" door on the 3 Tabs)
4. "Swing in" the lower edge of door until it touches lower firebox front.
5. Pull Holding Bar down and outward (away from Fireplace) until it clears doorframe.
6. Raise Bar until it fits securely in Bar Holding Brackets on doorframe.
7. Repeat procedure for opposite Holding Bar.
Door is now connected and sealed to unit.
Figure 4-7 Door Operation
Page 51
85-03-01115 DXV35 TIMBERFIRE Page 51
4.3 NATURAL GAS TO LPG CONVERSION
WARN ING
This conversion kit shall be installed by a qualified service agency in a cco rdance with the manufacturer’s
inst ruct ions and all applicable codes and requiremen ts of the autho rity havin g jurisdiction. If the info rmation in these instructions is not followed exact ly, a fire, explosion or production of carbon monoxide may r esult causing property damage, personal injury or loss of life. The qua lified service agency is responsible for the proper installation of this kit. The in sta llation is not proper and complete until the opera tion of the converted appliance is checked a s sp ecified in th e owner instructions supplied with the kit.
WARN ING: Failure to position the par ts in accordance with these diagra ms or failure to use only parts sp ecifica lly app roved with this appliance may result in property damage or personal injury.
A natural gas to LP gas conversion kit #HA-30-00237 must be ordered and installed in this fireplace to burn LP gas.
LP conversion kit #HA-30-00237 contains the following parts: one manual LP pressure regulator, one cap orifices #65-14-0050 (drill #50), a bell-shaped Pilot LP Orifice and an LP conversion label.
Procedure to Convert Fireplace for LP Gas
This fireplace arrives from the factory ready to burn natural gas. If you intend to burn LP gas, you must convert this fireplace and its pressure regulator, pilot orifice and burner orifices prior to placing this fireplace in its fireplace cavity. Follow the step below to prepare this fireplace for conversion to LP gas:
1. Shut off the gas supply to the valve and shut down the electric supply.
Note: Be careful when removing or tightening the screw on the pressure regulator. Care must be taken to ensure a proper seal
when tightened.
2. Install main burner orifice #65-14-00050 (#50 drill)
3. Orifice is removed and installed with a ½” deep well socket and ratchet.
4. While holding the pilot base body with large vice grips tightly, loosen the pilot’s hex-shaped base using a 7/16” open
end wrench. Rotate counter clock-wise to loosen. Remove pilot hood and NG pilot orifice. Pilot orifice thimble is located inside pilot hood base.
5. Install LP pilot orifice #05-04-00036 (.014”). Replace pilot hood and tighten.
CAUTION: Always
use one 7/16”
open end wrench and one large pliers or vice grips tool to hold, loosen and tighten pilot hood base to prevent damage to pilot mount bracket.
Figure 4-8 VALVE ASSEMBLY
PILOT HOOD
PILOT ORIFICE
USE
7
16
"
WRENCH TO
LOOSEN HOOD
Figure 4-9 Pilot Orifice Access
Page 52
85-03-01115 DXV35 TIMBERFIRE Page 52
6. Install the airbox and the burner in their original
locations and positions and secure down using screws you removed earlier.
7. Make certain burner is running parallel to front face of
unit and positioned properly. Next, the pressure regulator will be changed.
8. Using a ¼” flat blade screwdriver, remove 3 screws that
secure the NG Pressure Regulator to the gas valve body and remove NG Pressure Regulator as shown above. Identify the pressure regulator spring that is located in the center of the black rubber gasket. Discard both the black rubber gasket and spring.
9. Install the new LP Pressure Regular onto the gas valve
body in the same position and orientation as the NG Pressure Regulator you removed in Step 2, above. The LP Pressure Regulator can only be mounted in one position. Secure the LP Pressure Regulator in place using the 3 screws you removed in Step 2. Tighten down using a ¼” flat blade screwdriver.
Figure 4-10 Pilot Body
LP PRESSURE REGULATOR
NG PRESSURE REGULATOR
GAS VALVE BODY
SCREWS
Page 53
85-03-01115 DXV35 TIMBERFIRE Page 53
Burner Ignition Characteristics
Note: Connect gas supply and verify that the mini mu m in let and outlet pressures are conforming. Once the conversion to LPG and all the above steps have been completed, light the main burners.
Main burner should now light IMMEDIATELY and flame should not "lift" off burner. If there is any delay in ignition or if flame is "lifting off" burner, turn off burner and carefully check for proper installation of logs/coals, vent system and proper pilot flame impingement on burner. Logs or coals must not block pilot flame or main burner flame. Vent system must be leak proof.
WARNING: Do not proceed with operation o f this firep lac e un less burner "cycles" on/off without delays!
Pilot Flame and Burner Relationship Verification
Prior to completing the LPG conversion process, the qualified service technician must light the pilot light and verify the relationship between the pilot light flames and the main burners. The pilot light flames directed towards the propagation ports on the rear and front burner must overlap the propagation ports on the burners.
Th e pil ot light flames must be a min imum of 1” long and must overlap the propagation p orts on both the rear and front burner legs. Verify that the burner tubes ignite quickly and the burner flames pr opagate smoothly along the entire length of the burner.
Page 54
85-03-01115 DXV35 TIMBERFIRE Page 54
4.4 VENTING
WARN ING: Proper installation of the vent sy stem, as required in this manu al, i s vital to the perfo rmance of this Fireplace. Oversights or failure to c onform to all installation requirements will void the applicable war ranty.
Th e DXV35 TIMBERFIRE Fireplace must be vented vertically to the outside and must use a rigid co axial ducting system.
This h eat er mu st b e properly connected to a venting system in ac cordan ce with the manufacturer's inst allation instructions. Operation of this heater when not connected to a properly installed and main tained venting system can result in carbon monoxide (CO) poisonin g a nd possibly death.
If th e vent system of this appliance is disconnected for any r ea son, th e vent and air intake systems must be properly reassembled and resealed before this appliance is put into use.
CAUTION: Each installation must con for m to all local, state and national codes. Refer to the nation al fuel gas code and local zoning and code authorities for detai ls on installation requirements. The Mendot a Fir eplaces must be vented to the outside in accordance with the latest edition of the National Fuel Gas Code. In the absence of local codes, the installation must conform with National Fuel Gas Code ANSI Z223.1 (NFP A 54), or Canadian Code CAN1 -B149 or most current edition, also known as NFPA 54. Do not connect this Fireplace to a chimney flue serving a sepa rat e sol id fuel or gas-burnin g appliance.
Do Not Use any silicone sealants at pipe joints. Stove gasket cements may be used at pipe joints but is not required.
Wall Thimble Information
A wall thimble is required to be installed when penetrating any combustible wall, regardless of whether the wall Is an internal wall or an external wall.
Wall thimbles are designed to reduce the required clearances to the exterior surfaces of the vent pipe that pass through combustible walls. The hole size that is specified to be cut in the wall for installation of the wall thimble takes into consideration the reduced clearance requirement.
Page 55
85-03-01115 DXV35 TIMBERFIRE Page 55
DXV35 TIMBERFIRE Master Venting Chart
Note: This chart is applicable to both natural gas and LP installations.
12” minimum vertical pipe run required to be
connected directly to this fireplace’s flue starter collar.
Maximum horizontal run allowed with the
minimum 12” vertical run is 6”.
Maximum vertical run allowed is 55’. Maximum vent system length allowed is 55’. 12’ maximum horizontal run allowed with a
minimum 4 to 25’ starter section. Three 90° elbows may be installed anywhere within the 12’ horizontal run. If the starter vertical section is less
than 4’, use the chart and reduce 3’ for every 90°
elbow installed after the first 90° elbow.
High Altitude Installation Information
Prior to installing at altitudes higher than 7500, please contact the Mendota technical service department for specific venting requirements and venting restrictions.
Figure 4-11 MASTER VENT CHART
Page 56
85-03-01115 DXV35 TIMBERFIRE Page 56
Maximum Horizontal Run
Maximum Horizontal Run allowed is 12 feet if a vertical starter section that is between 4 feet to 25 feet is connected
directly to this fireplace’s flue starter collar and no more than three (3) 90-degree elbows are used.
Maximum Horizontal Run allowed is 12” if a 12” starter vertical section is connected directly to this fireplace’s flue
starter collar.
Maximum Vent System Length
Combined total length of all straight pipe sections in the vent system shall be less than 55 feet. Combined total length of all straight pipe sections in the vent system shall be less than 55 feet when using three (3) 90-
degree elbows or equivalent and terminating the vent system horizontally.
How to Calculate the Vent Lengths
For calculation purposes and usage of charts in this manual, simply add the lengths of all individual straight pipe sections. For example: if you use two 2-foot lengths and one 4-foot length, the total vent system length will be 2+2+4 = 8 feet.
Using 900 Elbows
The DXV35 TIMBERFIRE Fireplace by MENDOTA allows maximum flexibility in the use of 90o elbows in the vent system. The length of the first straight vertical section directly connected to the fireplace’s starter collar determines the maximum horizontal run and the number of 900 elbows allowed for this fireplace. For vent systems that provide a starting vertical section that is 4’ to 25’, you may connect up to 12’ of horizontal pipe and up to three 90° elbows.
Using 90° Elbows When the Initial Starter Vertical Section Is Less Than 4’
For vent systems that provide a starting vertical section less than 4’ the following rules apply:
A. You must use the Master Venting Requirements Chart. B. A single 90° vertical-to-horizontal elbow is already calculated into the allowable maximum horizontal run. The Venting
Requirements Chart assumes that for all horizontal runs calculated, one 900 elbow is used within the venting system.
Note: Each additional 90° elbow reduces the maximum horizontal distance allowed by 3'.
C. If you plan to use more than one 90° elbow within the vent system, first use the Venting Requirements Chart and
calculate the maximum horizontal run you are allowed based on the first vertical section connected directly to the
fireplace. From this maximum horizontal run calculated, subtract 3’ for each additional 90° elbow you will use.
Caution: If a vertical-to-horizontal discharge elbow or a horizontal-to-horizontal discharge elbow is enclosed within a wall, floor or
ceiling, a top air space clearance of 2” must be maintained above the entire body of the elbow.
Using 45-Degree Elbows
Two 45-degree elbows may be used in place of one 90-degree elbow. On 45-degree runs, one foot of diagonal pipe is equal to 8-1/2 inches horizontal run and 8-1/2 inches vertical run. Two 45-degree elbows may be connected directly to the vent starter adapter on this fireplace to create an offset to provide the required clearances to combustible framing or sheathing materials.
Two 45-degree elbows may be connected directly to the top of this fireplace to create a horizontal offset. 12 feet maximum horizontal run allowed with this offset configuration only if the first vertical section connected directly to the last 45-degree elbow is more than 4 feet to 25 feet long. For maximum allowable horizontal distances with the 45-degree offsets, see the Master Venting Configuration Chart.
Note: Each horizontally positioned 45º elbow reduces the maximum horizontal distance by 1½ '. SUPPORT: Horizontal runs of pipe will require one vent support for every 3 ft. of pipe.
Page 57
85-03-01115 DXV35 TIMBERFIRE Page 57
Minimum Rise Horizontal Termination
The minimum vertical section required to be connected directly to the starter adapter on this fireplace is 12”. With a 12” vertical starter section, a 6” horizontal run to a horizontal vent cap is allowed. If the total length of the vertical sections
connected directly to the starter adapter on this fireplace is between 4’ and 25, you are allowed a maximum 12’ horizontal run. This fireplace provides a maximum flexibility in the use of 90° elbows when more than 4’ of vertical starter section is connected to the starter collar. If 4’ or more vertical section is connected to the starter collar, you may use three 90° elbows for horizontal terminations. For other venting configurations within these maximum limits, see Master Venting Chart.
Combined total length of all pipe sections in the vent system should be less than 44’. NOTE: The horizontal run of vent pipe mu st b e level o r have a ¼" rise for every 1' of run toward the ter min ation . Never allow the vent to run downward. This will cause h igh t emperatures and the possibility of a fire.
Follow these steps to install venting:
1. Position fireplace in desired location. Check to determine if wall studs are in the way when vent system is attached. If this is the
case you may want to adjust the fireplace location.
2. Locate where vent pipe will pass through any ceilings and will penetrate the outside wall. Since vent pipe sections "overlap,"
we suggest pre-assembling and measuring the total vent pipe run so you can more accurately locate the point where the vent pipe will penetrate the outside wall. Be sure all vent components are properly twist locked and leak-proof.
3. Cut and frame a 9” wide x 10” high opening in the outside wall openings and 9” x 9” opening in ceiling openings. The outside
wall hole must be positioned so the vent system will have a ¼" rise per foot on horizontal runs and be perpendicular to the wall. The height of the opening must be located to meet all building codes and not allow the termination to be easily blocked or obstructed. A ceiling fire stop spacer is required at any floor (ceiling) opening.
4. The horizontal pipe must end flush with the exterior wall of the home. Horizontal pipe will require a proper support every 3’ of
vent pipe. There must be a minimum of 1" clearance to combustibles from all vent pieces on the sides and bottom and 2"
above horizontal runs.
5. A wall thimble must always be used when penetrating combustible wall materials.
6. Note: Combustible wall
thickness must be 4" to 8" maximum.
Note: Do not separate telescoping section. They be must be used as complete assemblies.
7. From the exterior of the
home, slide the horizontal vent cap over the end of the horizontal pipe and tightly secure the vent cap to the wall with screws. Seal with high-quality caulking around the outer perimeter of the vent cap. Note: Vent cap shall not be recessed into wall or siding.
Figure 4-12 MINIMUM RISE HORIZONTAL VENT
Page 58
85-03-01115 DXV35 TIMBERFIRE Page 58
Elevated Vertical Rise Through-The-Wall Venting
The required MINIMUM vertical rise is 48 in. when used with a maximum horizontal run of 12 ft. For other venting configurations within these maximum limits.
NOTE: All horizontal runs of vent pipe must be level or have a ¼" rise for every 1' of run toward the termination. Never allow the vent to run downward. This will cause high temperatures and the possibility of a fire.
USING OFFSETS AND RETURNS: A single 90º vertical-to-horizontal elbow is already calculated into the allowable maximum 12' horizontal run. Each additional 90º elbow reduces the maximum horizontal distance by 3'. Example: by using three total 90º elbows the maximum horizontal distance has been reduced to 6 ft. (3 - 1 = 2 elbows x 3' = 6'; 12’ Max. - 6' of elbows = 6' of horizontal run). Note: 45º elbows reduce the maximum horizontal distance by 1½ '.
SUPPORT: Horizontal runs of pipe will require one vent support for every 3 ft. of pipe.
CAUTION: If a vertical-to-horizontal elbow is enclosed within a wall, floor or ceiling, a top air space clearance of 2" must be maintained above the elbow. Be sure to maintain 1" air space to any combustibles on the sides and bottom, 2" above horizontal pipe sections.
THI S FIREPLACE MUST BE INSTALLED BY A QUALIFIE D MENDOTA APPROVED SERVICEPERSON.
1. Position fireplace in desired location. Check to determine if wall studs are in the way when vent system is attached. If this is the case you may want to adjust the fireplace location.
2. Locate the position where vent pipe will pass through any ceilings and will penetrate the outside wall. Since vent pipe sections "overlap" we suggest pre-assembling and measuring the total vent pipe run so you can more accurately locate the point where the vent pipe will penetrate the outside wall Be sure all vent components are properly twist locked and leak­proof.
3. Cut and frame a 9-1/2” wide x 10” high openings in the outside wall openings and 9” x 9” opening in ceiling openings. The outside wall hole must be positioned so the vent system will run level or have a ¼" on rise AND be perpendicular to the wall. The height of the opening must be located to meet all building codes and not allow the termination to be easily blocked or obstructed. A ceiling fire stop spacer is required at all floor (ceiling) penetrations.
4. Connect vent pipe to the fireplace adapter on top of fireplace vent outlet.
5. The horizontal pipe must end flush with the exterior wall of the home. Horizontal pipes will require proper support every 3 ft. of vent pipe. THERE MUST BE A MINIMUM OF 1" CLEARANCE TO COMBUSTIBLES ON THE SIDES AND BOTTOM OF ALL VENT PIECES (2" above horizontal runs a nd above e lbows).
6. A wall thimble must always be used when penetrating combustible wall materials.
NOTE: Combustible wall thickness must be 4" to 8" maximum for the wall thimble. Wall more than 8” thick will require special
protection. Contact Mendota Technical services for assistance.
7. From the exterior of the home, slide the horizontal vent cap over the end of the horizontal pipe and tightly secure the vent cap to the wall with screws. Seal with high quality caulking.
WARNING: Venting terminal shall never be recessed into wall cladding or siding. Vent Cap must sit on top of siding or cladding.
Page 59
85-03-01115 DXV35 TIMBERFIRE Page 59
Vertical Through-The Roof Venting
The maximum vertical run of vent pipe is 55 ft. from the top of the fireplace. The fireplace will support a run of a maximum of 55 ft. The vent system must be supported every 3 feet using Support Straps. Maintain 1" air space
clearances on all sides of vent components that are positioned vertically and 2” above horizontal pipe sections and
components.
THI S FIREPLACE MUST BE INSTALLED B Y A QUALIFIED MENDOTA APPROVE D SERVICEPERSON.
1. Place the fireplace in its desired location. Drop a plum bob from the ceiling to the position of the fireplace flue exit.
Mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plum bob from the roof to the hole previously drilled in the ceiling. Mark and drill the spot where the vent will penetrate the roof. Determine if ceiling joists, roof rafters or other framing will obstruct the venting system. You may choose to relocate the fireplace or choose to offset the vent system to avoid cutting load bearing members.
2. Cut and frame a 9" x 9" opening in the ceiling centered on the hole drilled in Step 1.
3. To determine the length of the vent pipe required, measure the distance from the fireplace flue outlet to the ceiling,
the ceiling thickness, and the vertical rise in the attic or second story and allow sufficient vent height above roofline. For two story installations, fire stops are required at each floor level. If an offset is needed in the attic, additional pipe and elbows will be required.
4. Assemble the desired lengths of vent pipe and elbows to reach from the fireplace flue outlet. Ensure that all vent pipe
and elbow connections are in their fully twist-lock position and that inner pipe joints are sealed and are leak-proof. Maintain 1" airspace clearances to combustibles around vertical pipe sections and 2" clearance above horizontal run sections.
5. Cut a 9" x 9" opening in the roof, centered in the small drilled hole placed in the roof in Step 1. The opening should be a
sufficient size to meet all clearance requirements. Continue to assemble lengths of pipe and elbows necessary to reach up through the roofline. Galvanized pipe and elbows may be utilized in the attic, as well as above the roofline. The galvanized finish is desirable above the roofline due to its higher corrosive resistance.
a. If an offset is necessary, it is important to support the vent pipe every 3 ft. to avoid excessive stress on the
elbows and possible separation. Wall straps are available for this purpose.
b. Whenever possible, use 45º elbows instead of 90º elbows. The 45º elbow offers less restriction to the flow of
flue gases and intake air. If a 90º elbow is necessary there must be a minimum of one pipe section rise between the 90º elbow and the vent cap. A maximum of three 90ºelbows are allowed per installation.
6. Slip the flashing over the pipe sections protruding through the roof. Secure the base of the flashing to the roof with
roofing nails and seal flashing to roof. Ensure the roofing material overlaps the top edge of the flashing. Verify you have at least the minimum clearance to combustibles at the roofline.
7. Continue to add pipe sections until the pipe and the vent cap meet the minimum building code requirements. a. For multi-story vertical installation, a ceiling fire stop is
required at the second floor and any subsequent floors. The opening should be framed to 9" x 9" inside dimensions as described in step No. 5.
b. Any occupied areas above the first floor, including
closets and storage spaces, which the vertical vent passes through, must be enclosed. The enclosure may be framed and sheet rocked with standard construction materials, however, be sure to maintain minimum allowable clearances between the outside of the vent pipe and the combustible surfaces of the enclosure.
8. Height "*H" of top of vent cap can be determined as follows:
9. Complete installation with storm collar and vent cap.
Height "*H" from roof surface to the top of vent cap can be determined as follows:
Complete installation with storm collar and vent cap.
"H" DIMENSION
ROOF PITCH
FEET
METERS
FLAT to 6/12
2
.6
7/12 to 9/12
2
.6
10/12 to 12/12
4
1.2
13/12 to 16/12
6
1.8
17/12 to 21/12
8
2.4
Page 60
85-03-01115 DXV35 TIMBERFIRE Page 60
Vent Damper Adjustments
This fireplace is equipped with a vent damper system that can be adjusted. Locate damper adjustment rod above the glass
frame in convection chamber at the center. If this fireplace’s vent is terminated horizontally, DO NOT CLOSE the vent damper
completely. Adjust position of damper by judging the flame characteristics after 20 minutes of burn time. If the flames ghost off burners or if sooting occurs [in LPG units], open the vent damper FULLY and work backwards in increments to determine the correct damper position for that particular installation. Look into the convection air cavity and note the Damper Position Indicator. Loosen damper base screw. Turn counter-clockwise to close the vent damper, tighten screw.
If this fireplace’s vent is
terminated horizontally, DO NOT CLOSE the vent damper completely.
Figure 4-13 Exhaust Damper Adjustment
Page 61
85-03-01115 DXV35 TIMBERFIRE Page 61
4.5 TIMBERFIRE LOG SET INSTALLATION
With door removed, proceed as follows:
1. Before placing log assembly in firebox, fill space under Log Grate with coals.
2. Follow the diagrams below in the sequence given. Start by identifying the Log Pins and Pin Hole in the Airbox. Next, identify
the log pieces according to the diagram below.
3. Place glowing embers (wool) sparsely on top coals, in front of front log. Additional wool may be rubbed on front surfaces of
log for additional glow. Add wool to "burned out" space between front logs. Fill area to back burner.
WARNING: Do not block holes with excessive wool. Delayed ignition and sooting can occur.
4. With glass removed, light pilot, and check for smooth ignition. Reinstall door, and check for smooth ignition. If any delay occurs,
make sure that no coals or wool is blocking pilot from front or rear burner holes.
5. Reinstall door, and check for smooth ignition again. If any delay occurs, make sure that no coals or wool is blocking pilot from
front or rear burner holes. Remove glass door, correct problem and repeat steps 4 and 5.
Page 62
85-03-01115 DXV35 TIMBERFIRE Page 62
Page 63
85-03-01115 DXV35 TIMBERFIRE Page 63
Page 64
85-03-01115 DXV35 TIMBERFIRE Page 64
Page 65
85-03-01115 DXV35 TIMBERFIRE Page 65
Note: Installer, save and give the copy of the Log Set In stal lation Instructions to the homeowner for future referen ces.
Page 66
85-03-01115 DXV35 TIMBERFIRE Page 66
4.6 AIR SHUTTER CONTROL AND FLAME APPEARANCE
During initial installation, the air shutter opening should be checked to be certain that the shutter is set correctly at 1/8" open for natural gas and 1/2" minimum open for L.P. gas. NOTE: For altitudes above 5,000’, some variations may be required. Be sure burner and logs are properly installed. After log set has been properly installed, adjustments to the air shutter shall be made for final flame appearance. These small shutter adjustments can be made by the following procedure:
NOTE : All adjustments to the air shutter setting must be made by a qualified in sta ller, service agency, or the gas supplier. Very small changes in shutter settings mak e major changes in flame appearance.
The burner air shutter adjustment knob is located on the left side of the gas valve, below the spark ignitor button. Push the knob to
close the air shutter or pull on the knob to open the air shutter.
1. If flame is too blue, close air shutter in small 1/8"
increments until flame turns desired realistic yellow. Use glass latch tool to hook end and slide control.
2. If flame is causing soot on viewing glass, open air shutter fully until sooting stops. Continue burning unit with air
shutter fully open for four to six hours until all internal deposited soot has burned off.
3. Once deposited soot has disappeared, close air shutter in increments of 1/8”.
LPG Air shutter settings hint: A properly adjusted air shutt er sett ing will yield burner flames that have an approximate 2” high blue color base. If yellow colo red flames are starting at burner level, air shutter is clo sed too far and will create soot. If you observe that th e fla me is y ellow startin g very close to or at the burner surface level, open air shutter. Also, i f a log or part o f a log is susp ended and hanging inside a yellow portion of the flame, soot can form easily on th e p art of the log that is inside the yellow flame area.
IMPORTANT: Try each new shutter setting approx. ½ hr. before making additional change s. NOTE: Changes in fr ont burner flame can be made by re -arranging the coals and front bur ner air shutter opening.
Figure 4-14 Burner Air Shutter Controls
Page 67
85-03-01115 DXV35 TIMBERFIRE Page 67
4.7 LIGHTING CHECKLIST
Be sure to check these items before final operation of the Fireplace.
All items on "Installation Checklist" must be completed. Carefully follow all lighting and log installation instructions. Make certain that pilot flame lights immediately and lights both
front and rear burners.
☐ Check for Gas leaks and gas pressures prior to installing facing materials. ☐ Air shutter opening 0" to ⅛" natural gas or ¼” to ½” LP gas is checked. All lighting and log installation instructions were followed. Burners light immediately and flame runs promptly around rear burner and lights entire burner.
Note: Do not proceed with operation unless burner cycles "on/off" without delays.
Flame is "stable" and does not "lift" off burner. If flame lifts off burner, turn unit off and check that all vent pipes are
"twist locked" and leak proof, the vent cap is "right side up”. Do not proceed with operation if flame is "lifting off" burner.
DO NOT proceed with operation unless burner cycles "on/off" without delays and the flame is "stable" and not "lifting" off
burner after 5 minutes of initial ignition.
Caution: If pilot goes out, be sure to wait a minimum of five minutes before relighting.
Page 68
85-03-01115 DXV35 TIMBERFIRE Page 68
HOMEOWNER INFORMATION
Welcome to Mendota. We are proud to be the makers of world-class direct vent fireplaces and Fireplaces. We understand that a fireplace is a long-term investment, and we are happy you have chosen us to be a part of your family. We are committed to quality and satisfaction for all Mendota owners. Thank you for choosing a Mendota to be a source of comfort and beauty in your home. We have designed this manual to help you enjoy all that your Mendota Fireplace has to offer. You will find tips, operating instructions, and frequently asked questions to support the features and functions of your Fireplace. We want you to enjoy your Mendota for years to come. If you have any additional questions regarding operation of your Fireplace, please contact your Mendota local dealer.
5.1 AESTHETIC CONSIDERATIONS
Burning or static fireplaces are a major aesthetic focus in any room. In addition to offering the most realistic log details, textures, coloration and the most realistic wood fire options, Mendota also offers a large array of internal firebox lining options and external decorative options. Visit www.mendotahearth.com and your local Mendota dealer’s show room to view all options available.
5.2 HEATING PERFORMANCE
Mendota’s high heat output Fireplace will heat a large area of your home. Air movement options for maximizing heat circulation that can be considered are operating the Fireplace’s convection blowers, continuous operation of central heating furnace blowers or room ceiling fans. The heat output of the fireplace can be reduced by reducing flame height. Blowers can be turned down or turned off to reduce heat distribution.
5.3 IMPORTANT INFORMATION FOR HOMEOWNER
Before you begin operation of your Gas Fireplace Heater, read and familiarize yourself with information provided in the following chapters of this manual:
Page 69
85-03-01115 DXV35 TIMBERFIRE Page 69
5.4 First Time Lighting Instructions
Safety Information
LIGHTING INSTRUCTIONS
IMPORTANT: Be sure all items on "INSTALLATION CHECK OFF LIST" (pg. 39 have been co mpleted! CAUTION: If the pilot goes out , be sure to wait a minimum of five minutes befor e r elighting.
BE SURE TO ALWAYS REMOVE THE GL ASS BE FORE RELIGHTING THE PILOT.
ALWAYS LIGHT PILOT WITH GLASS REMOVED! 1 Make sure any gas supply shut-off cocks are
open and Thermostat is "OFF".
2 Push in Gas Cock Dial Slightly and turn clockwise to
"OFF". NOTE: Dial cannot be turned from "PILOT" to "OFF" unless dial is pushed slightly. DO NOT FORCE!
3 Wait five (5) minutes to allow gas, which may have
accumulated in main burner compartment to escape. If you smell gas, STOP.T
4 urn Gas Cock Dial Counterclockwise to "PILOT"
position.
5 Depress Gas Cock Dial and push in red Piezo igniter button. Once pilot ignites, continue depressing dial for about 1/2 minute.
If pilot does not remain ignited, repeat operation allowing a longer period before releasing Gas Dial. IMPORTANT: After pilot is lit, system millivolt readings and gas pressure should be taken by qualified installer. Pilot flame must register a minimum of 325 millivolt.
6 After pilot is lit and before installing logs, turn Gas Dial to "ON" and "cycle" the burner on/off to make certain it ignites
promptly and that the flame runs smoothly around burner curve and promptly lights entire burner.
7 With pilot operating, install log module and coals (see pg. 34-38). With logs/coals in place, "cycle" the burner again to make
sure of prompt ignition of burner and that the flame runs smoothly around entire burner and does not "lift off" burner. NOTE: Logs will produce a strong, acrid odor on initial contact with flames (about 2 hrs.).
8 Reinstall glass front & screen.
9 Turn Gas Dial counterclockwise to "ON" then set Thermostat to turn on burner.
Main burner should now light IM MEDIATELY and flame should not "lift" off burner. If there is any delay in ignition o r if flame is "lifting off" burner, turn off burner and c arefu lly check for proper installation of logs/coals, vent system and proper pilot flame im pingement on burner and thermopile. Logs or coals mu st not block pilot flame or main burner flame. Vent system must be leak proof. DO NOT PROCEED WITH OPER ATION UNLESS BURNER "CYCLES" ON/OFF WITHOUT DELAYS!
Warning: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury, and loss of life.
WHAT TO DO IF YOU SMELL GAS Do not light any appliance. Do not touch any light switch Do not use any phone in your building. Call your gas supplier from a neighbor's phone. Follow the provider representative's instructions. If you cannot reach your gas supplier, call the fire department for assistance.
Figure 5-1 Gas Valve
Page 70
85-03-01115 DXV35 TIMBERFIRE Page 70
10 To reduce heat output, turn Hi/Lo Knob counterclockwise to desired temperature (see Error! Reference source not found.).
Heat output can be reduced by up to 11,000 BTUH (1/3). Blower can also be turned down. NEVER "over fire" by increasing BTUH above nameplate specifications. NEVER turn down (reduce) pilot flame below the minimum 325 millivolts.
11 Open windows for first two hours of operation.
NOTICE: Initial start-up will cau se some N ON-TOXIC "off gassing" of adhesives, bind er s, pa int, etc. Most nuisa nce odors will be eliminated after the first 2 hrs. of operation, ho wever, slight amounts may be present during the first 24 hrs.
5.5 TO TURN OFF GAS TO FIREPLACE
1. Turn Thermostat to "OFF". Pilot will remain lit for return to normal service.
2. For complete shutdown turn Gas Cock Dial to "OFF".
3. Turn off the internal manual shutoff valve in the appliance. See 3.4.6 Factory Installed Manual Gas Shutoff Valve.
Page 71
85-03-01115 DXV35 TIMBERFIRE Page 71
5.6 FREQUENTLY ASKED QUESTIONS
What to do if I smell gas?
If you smell gas:
Do not light any appliance. Do not touch any light switches. Do not use any phone in your building. Call your gas supplier from a neighbor's phone. Follow the provider representative's instructions. If you cannot reach your gas supplier, call the fire department for assistance.
Where can I find the model and serial numbers?
When requesting service, you will be asked to provide the model number and serial number to your Mendota dealer. This information will expedite the warranty verification process. The Listing Label contains the model number and serial number for your particular appliance.
This is an example of your listing label:
Listing label location: The listing label is located in the air gap below the bottom edge of the glass door frame. It is attached to a cable and can be pulled out to be viewed.
Figure 5-2 Listing Label
Page 72
85-03-01115 DXV35 TIMBERFIRE Page 72
Can I use my Fireplace during power outages?
This ignition system utilizes thermocouple and thermopile power for pilot and burner ignition functions. AC power is utilized for blower function only. If the AC power is interrupted during a power outage, you may operate this fireplace for one continuous hour on and one continuous hour off cycles only.
During the power outage, the appliance’s burners will function. In addition, Flame Height adjustment function will be available. The Fan, which is wholly dependent on 110VAC power, will not function.
5.7 WHAT MAINTENANCE IS REQUIRED?
Required Annual Maintenance
The following procedures must be performed each year by a qualified installer, service agency or the gas supplier. Note: Any adjustments to burner, pilot or logs must be done by a qualified installer, service agency or the gas supplier. Recommended steps for yearly maintenance:
1. Clean all lint and dust build-up around the control. Inspect the condition of any wiring under the burner for melting or
damage.
2. Clean pilot thermocouple, thermopile and sparker rod using emery cloth. Vacuum clean pilot light assembly.
3. Visual check of pilot flames is required. Pilot flame must overlap thermocouple tip and burner ignition ports always.
Especially for LP gas applications, always verify visible pilot flame length is at least 1" long.
4. Vacuum all burner ports. Be sure the burner ports are "open".
5. Visual check of main burner’s rear and front flames is required.
6. Remove logs and coals and clean away any foreign matter (lint, carbon, etc.) on the burner and logs.
7. Clean under side of the logs for any carbon deposits. Note: Logs should be visually checked for carbon buildup. If carbon
deposits are visible on logs, unit should be turned off and a qualified installer, service agency or the gas supplier contacted. Be sure logs are re-installed per instructions.
8. Check condition of glass door gasket, gasket must seal tightly over firebox. Inspect gasket along top and sides of glass. If
gasket bulb along top edge or side top areas are discolored to a white color appearance (through the whole thickness of the gasket bulb in a 3” to 12” long area) and the gasket adhesive in no longer functional to stick to glass, then replace the gasket.
9. Visually inspect the vent terminal (vent cap) for leaves, twigs and other debris accumulation. Clean if required.
10. Clean door glass.
11. Clean enamel firebox lining, if one is installed.
Page 73
85-03-01115 DXV35 TIMBERFIRE Page 73
Periodic Inspection
Follow these steps for periodic inspections:
1. Check to verify that the vent system and vent cap are open and free of blockage.
2. Before re-installing glass, have qualified service person check the operation of the pilot and cycle the burner per lighting
instructions. Be sure all items in lighting and installation checklists are completed.
3. Periodic visual check of pilot flames is required. Pilot flame must overlap thermocouple tip and burner ignition ports
always. Especially for LP gas applications, always verify visible pilot flame length is at least 1" long.
4. Periodic visual check of main burner’s rear and front flames is required.
How do I clean the viewing glass?
The viewing glass should be cleaned periodically. Exterior glass surface may be cleaned with cleaner as desired. To clean interior glass surface, use Kel Kem Polish Plus (part # 65-06-00455) or a comparable product. Caution: Do not use oven cleaner to clean glass. Clean the glass only when it has cooled to room temperature.
Additives that are put in gas (both natural and p ropane) to make it smell can be harmful to glass and can lea ve a white fi lm deposit on the glass. This d epo sit can b e removed, if cleaned in a timely manner, with cleaners such as KEL KEM “Polish Plus” (part # 65 -06-0 04 55) or co mpar able product (contact your dealer).
Is my flame performance correct?
Your fireplace has air shutters, dampers, coals, and embers that can be adjusted depending on your fuel and venting configuration. These adjustments should be made by a qualified technician to achieve the best flame performance. Contact your installer or Mendota dealer if you feel your fireplace is not burning correctly. Improper setup and adjustment is not covered under warranty.
What should I do if my fireplace is sooting?
Sooting is caused by improper installation or air shutter operation. However, some small areas of soot deposits on log surfaces are deemed acceptable. If you observe large soot areas (larger than 1”x1”) on log surfaces or signs of sooting on the door glass (usually a thin black film on the Fireplace viewing glass or on the outside of the home around the vent cap), the unit must be immediately turned off and the local Mendota dealer promptly informed. Mendota dealers will correct "sooting" problems, but Mendota and their dealers are not responsible for damage caused by excessive sooting that has not been immediately brought to their attention. Troubleshooting soot:
Issue: Thin black coating (soot) forms on viewing glass.
Possible Causes:
A. Burner Air Shutter closed too
much.
B. Exhaust Damper is closed too
much.
C. Improper log and/or ember
placement
D. Glass door seal is
compromised.
E. Incorrect gas pressure or
burner orifice size.
Corrective Action: Open air shutter on burner fully. Check exhaust damper position. It may be closed too far. Open exhaust damper. Check glass gasket for proper seal. Corners of glass gaskets cannot be bulging out. If glass gasket along top edge in the middle is white in color across entire thickness of gasket bulb and gasket adhesive is not functional, replace glass gasket. If sooting continues, shut off unit and call Mendota service person. Have service person check for proper Orifice Sizes and correct gas outlet pressure (3.5" W.C. Nat. Gas; 10" W.C. LP Gas). NOTE: To clean glass - remove glass and wipe glass with cloth or paper towel.
After completing these steps, contact your Mendota dealer if fireplace won’t turn on.
What happens when I first light my fireplace?
When you first light your fireplace, the initial curing phase is initiated. During the initial curing phase, a small amount of smoke and odor will be emitted. This is normal. To complete the curing process, run your fireplace, on high fire, for two hours with the fans on level 3. Open doors and windows to dissipate any odor. Turn your fireplace off. After it has cooled, run it again, on high fire, with the blowers off until no smoking or odor remains. Refer to Chapter 3.1.1 Mendota Fireplace Curing Instructions for more information.
Page 74
85-03-01115 DXV35 TIMBERFIRE Page 74
MAINTENANCE INFORMATION
6.1 REQUIRED PERIODIC INSPECTIONS
1. Check to verify that the vent system and vent cap are open and free of blockage.
2. Have qualified service person check the operation of the pilot light. Pilot light must light within the first five to eight
seconds of ignitor sparks initiation. If it takes more ten seconds to ignite the pilot flame, check pilot spark rod position and ignitor wires for pinched areas or damaged areas.
3. Periodic visual check of pilot flames is required. Pilot Flame
must overlap thermocouple tip and burner ignition ports always. Especially for LPG applications, always verify visible pilot flame length is at least 1" long, minimum.
4. Cycle the burners to make certain burner ignition is prompt
and flame propagation along burner length is quick and smooth. If flame propagation is delayed, remove obstructing debris, vacuum burner ports and retry.
5. Periodic visual check of rear and front burner flames pattern
is required.
6.2 CLEANING VIEWING GLASS
WARN ING: Do not clean when glass is hot.
The viewing glass should be cleaned periodically. Exterior glass surface may be cleaned with cleaner as desired. To clean Interior glass surface, remove glass frame assembly.
See 0
Figure 6-1 Pilot Flame Lengths
Page 75
85-03-01115 DXV35 TIMBERFIRE Page 75
. Use Kel Kem “polish plus" (part # 65-06-00455) or comparable product to clean glass interior surface. Do not use oven cleaner or abrasive cleaners to clean glass.
6.3 REQUIRED ANNUAL MAINTENANCE
See Chapter 5.7 What maintenance is required? In addition to the “Required Periodic Inspection s” , the fol lo win g pro cedures m ust be performed each year by a qualified installer, service agency or the gas supplier . Any adju st ments to burner, pilot or logs must be
done by a qualified installer, service agency, or the gas supplier . Clean all lint and dust build-up around the control and blowers. Inspect the condition of any wiring under the burner for melting
or damage. Clean thermocouple and thermopile tips using emery cloth. Vacuum all burner ports and pilot assembly. Remove logs & coals and clean away any foreign matter (lint, Carbon, etc.) on the burner and logs. Be sure the burner ports are "open". Clean the pilot and under side of the logs for any Carbon deposits.
NOTE : Logs should be visually checked for Carbon "build-up". If heavy carbon deposits are visible on logs, unit should be turned off and a qualified installer, service agency, or the ga s supplier should b e contacted. Be su re log s are re-installed per instr uctions.
Check glass gasket seal. Visually inspect glass gasket, especially at the corners of the glass piece. Glass gasket is installed as a 4­piece assembly. Check joints between the gasket pieces at the corners. They should butt against each other to create a seal. Gaps between gasket pieces can cause exhaust leaks and lead to acrid smell concerns.
Page 76
85-03-01115 DXV35 TIMBERFIRE Page 76
6.4 OVER FIRING OR UNDER FIRING OF BURNER
NEVER "over fire" or “under-fire” units by increasing or decreasing the main orifice sizes or by adjusting gas pressure to increase BTUH above nameplate specifications.
Over fi rin g can cause permanent damage to firebox and deterioration o f pa rts and void the warranty. Under-firing can potentially cause delayed ignition and lead to property loss and person injury and will void the warranty.
If you a re using a “backyard” Natural Gas well as t he ga s so urce, you must submit formal gas analysis data
sh eet s to Mendota Fireplaces for review and calculation of prop er main burner orifice sizes prior to first fir ing. It is known that unpurified Natural Gas from “backyard” wells can contain high energy levels ca using over firing. Further, unpurified gas can contain high levels of Sulphur and other compounds which can damage the burner materials and the ceramic gla ss. Use o f unpur if ied gas will void the warranty for this product.
6.5 PILOT OUTAGE AND RE-LIGHTING
If pi lot goes out, be sure to wait a minimu m o f five minutes before attempting to re -light. If lockout occu rs frequently, contact you Mendota Dealer for diagnosing th e pr oblem.
Frequent lockout can be caused by many factors and must be properly diagnosed, and the primary cause identified. It should never be assumed that the ignition control system is faulty without proper diagnosis.
6.6 BURNER FLAME HEIGHTS REFERENCE DIAGRAM
Figure 6-2 Burner Flame Heights: This image provides a visual reference for the burner flames burning at maximum height after the burners have been operating for 30 minutes or longer. A normal rear flame will be 1 to 2 inches above the rear log top edge. This, however, is dependent on the gas type, air shutter opening setting and vent system configuration. Actual flame heights can be slightly higher or lower when compared to this reference image.
Page 77
85-03-01115 DXV35 TIMBERFIRE Page 77
6.7 REPLACEMENT PARTS INFORMATION
How to Access Components
The descriptions below show where the main fireplaces components are located and how to access them for service. The descriptions show how to access the components after the fireplace has been installed. All components are also accessible from the outside of the unit before the fireplace is installed.
Pilot: The pilot light is located on the right side the firebox to the right ends of the burners. Gas Valve: The main gas valve is located behind the lower grill and beneath the firebox. Complete Valve Assembly: To make working on components easier, this fireplace has been designed with the valve, pilot,
shutter boxes, shutter cables and gas lines as part of one assembly that can be removed from the fireplace. To remove the assembly, first remove burners and burner airbox. After disconnecting the gas line and wires, below the firebox, remove hex nuts that secure the valve mounting plate to firebox floor. Lift up and remove the entire assembly from the firebox.
Convection Blowers: The convection blowers are mounted on the firebox’s rear wall. To access the convection blowers, remove the Valve Assembly first.
General Replacement Parts List
PART NO
DESCRIPTION
PART NO
DESCRIPTION
65-02-00103
TADPOLE GLASS GASKET (106”)
05-04-00035
PILOT ASS'Y. NAT.GAS
65-06-00463
GLASS – FLAT
HA-30-00237
LP KIT
HA-30-00415
DOOR FRAME ASSEMBLY – FLAT
65-14-00030
ORIFICE (NAT. GAS) # 30
35-01-00240
COALS 12 OZ BAG
65-14-00049
FRONT ORIFICE (NAT. GAS) # 49
35-01-00239
GLOWING INSWOOL
15-02-00120
R H BLOWER WITH MOTOR
35-01-00601
FIREBRICK KIT
15-02-00121
L H BLOWER WITH MOTOR
05-02-00313
SIT VALVE NAT. GAS
65-06-00125
BLACK PAINT - 12 OZ. SPRAY CAN
HA-30-00470
PILOT ASSY. LPG
65-06-00455
KEL-KEM GLASS CLEANER/POLISH
Page 78
85-03-01115 DXV35 TIMBERFIRE Page 78
Convection Air Blower System Parts
Item 1
15-02-00120
BLOWER, RH
Item 2
15-02-00121
BLOWER, LH
Figure 6-3 DXV35 TIMBERFIRE BLOWER ASSEMBLIES
Valve Assembly Replacement Parts
Item 1
65-14-00030
NG Orifice, #30
Item 2
05-04-00035
Pilot Assembly, 3-way hood
Item 3
65-06-01064:1
Spark Ignitor
Item 4
05-02-00313
Main Gas Valve
Figure 6-4 Valve Assembly Replacement Parts
Page 79
85-03-01115 DXV35 TIMBERFIRE Page 79
Glass Frame Parts Replacement Procedure
WARN ING: do not use substitute materials. All replacement mat erials must be certified and obtained through Mendota fireplaces.
TO REPLACE DAMAGED GLASS
1. Bend glass retainer tabs up 90 degrees. Four tabs hold down the glass and gasket assembly.
2. Remove the damaged glass and gasket material. Clean the inner surface of the glass frame.
3. Assemble new gasket on glass edge starting with the bottom left corner. The adhesive on the gasket should contact the
glass surface. Use tracer lines in gasket to determine where the glass should sit on the gasket surface.
4. Place glass and gasket assembly in glass frame and carefully bend down glass retainer tabs. Extra glass retainer tabs are
provided should any originally used tabs break off. The glass frame assembly and its individual components are available through Johnson Gas Appliance Company. Contact your dealer for more detailed ordering information.
GLASS FRAME ASSEMBLY REPLACEMENT PARTS LIST
ITEM
PART NUMBER
DESCRIPTION
1
HA-29-00522
FRAME, GLASS, DXV35 TIMBERFIRE
2
65-02-00103
GASKET, TADPOLE, 5 /8” BULB, 3/4” TAIL, 110”
3
65-06-00463
GLASS, CERAMIC, DXV35 TIMBERFIRE
Page 80
85-03-01115 DXV35 TIMBERFIRE Page 80
WARRANTY QUALIFICATION AND SERVICE
The following information verifies proper installation and operation of your Mendota fireplace. All installation and operating instructions must be carefully followed. This Mendota fireplace must be installed and serviced by a qualified installer, service agency, or the gas supplier.
7.1 FINAL INSTALLATION AND HOMEOWNER CHECKLIST
INSERTS ONLY: The existing woodburning fireplace and its chimney system are structurally sound, professionally cleaned,
intact and remain woodburning capable (inserts only).
INSERTS ONLY: Woodburning chimney interior and chimney top cap are inspected and repaired or replaced if damaged. No offensive odor emitting materials exist around appliance such as low temp rated adhesives, plastics or others. All surrounding finishing materials are conforming to manual requirements. Electrical power supply system conforms to NEC and local electrical codes. Gas supply must conform to national and local building codes. All gas line joints were checked for leaks using gas leak detector solution or a gas sniffer. All internal gas plumbing joints were checked for leaks using gas leak detector solution or a gas sniffer. Glass gasket was inspected and verified that it is sealing properly. Gas supply line was bled of air and pilot flame was ignited. Pilot flame overlaps burner flame propagation ports properly. Burners light and flames travel promptly along entire length of burner. Logs/media are installed properly per installation instructions. Burner(s) air shutter is adjusted properly. Shutter opening set properly per installation manual. Burner flames are “stable” and are not “lifting” off burner. Inform owner that an initial curing step is required. Read and follow Mendota Fireplace and Insert Curing Instructions
(found on unit and in owner’s manual). Smoke will emit during initial curing step.
Provide owner with contents of owner’s manual packet.
Owner’s manuals, remote control transmitter, glass latch tool, backup battery system, etc.
Train owner how to remove and reinstall decorative front. Train owner how to remove and properly reinstall glass door. Inform owner about the glass safety screen barrier requirement. Train owner on remote control functions.
Inform owner about IPI and CPI mode and that CPI shall be used for winter months.
How to light the pilot light.
How to light the main burners and how to control the flame height.
How to turn the fan on and how to control fan speed.
How to turn light on and how to control light brightness.
How to turn the rear burner on and off.
Explain manual mode operation.
Explain thermostatic modes operations.
Train owner about lockout mode and how to reset it. Train owner how to use backup battery system and operate appliance during power outage. Train owner about master switch location and emergency shutoff function. Train owner how to operate manual shutoff gas valve using glass latch tool. Inform owner that periodic maintenance of this unit is required per manual.
WARNING: MENDOTA GAS FIREPLACES ARE HEAT PRODUCING APPLIANCES. KEEP CHILDREN AND FURNITURE A SAFE DISTANCE AWAY TO PREVENT PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
I have trained and informed homeowner of all the requirements listed above.
Staff Name_______________________________________ Staff Signature Date_________________________________
Homeowner’s Name_______________________________ Homeowner’s Signature Date__________________________
Page 81
85-03-01115 DXV35 TIMBERFIRE Page 81
7.2 WARRANTY POLICY STATEMENT
Mendota Fireplace, a division of Johnson Gas Appliance Company, extends this Limited Lifetime Warranty to the original purchaser of this appliance provided the product remains in the original place of installation. The items covered by this limited warranty and the period of such coverage is set forth in the table below.
Some conditions apply (see below). The policy is not transferable, amendable or negotiable under any circumstances.
Description
Lifetime
3 years
Parts Coverage
2 years
1 year
90 days
Firebox and Heat Exchanger
STD
Glass-thermal (breakage only)
STD
Stainless Steel Burner Tubes/Ceramic Burners
STD
All Castings
EXT
STD
Valve Assembly and all gas control components (Pilot Assembly, Flame Sensor, Spark Electrode, Pilot Tubing, Orifices, Thermocouple, Thermopile)
EXT
STD
All other Electrical Components (Ignition Control Boards, Wiring, Switches, Blowers, Blower Control Module, Battery Pack)
EXT
STD
Venting/Venting Components
EXT
STD
Remote Control Transmitter
EXT
STD
Exterior Painted Finishes
EXT
STD
Exterior Plated Finishes
EXT
STD
Brick Panels and Log Sets (coloration failures only)
EXT
STD
All Firebox Media (Glass Beads, Ceramic Stones, Tumbled Marble)
EXT
STD
All hardware
EXT
STD
Mesh/Glass Safety Barriers
EXT
STD
Enamel Panels
STD
Accent Light Bulbs
STD
STD
= Mendota Standard Warranty
EXT
= Mendota Extended Warranty With Registration
Page 82
85-03-01115 DXV35 TIMBERFIRE Page 82
7.3 CONDITIONS
Warranty protects against defect in manufacture or Mendota factory assembled components only, unless herein specified
otherwise.
It remains the full responsibility of the owner to operate this appliance within the guidelines provided in the Installation and
Operating Instructions Manual accompanying this appliance. Further, the owner shall bear full responsibility to enforce
clearances to combustibles requirements and cautioning others about hot glass surface and hot metal surfaces.
Owner by operating this appliance accepts that this is a heat producing appliance which has glass and steel parts that are hot
enough to cause severe burns. Owner accepts that this appliance requires close monitoring of children and vulnerable
individuals who are in the vicinity of this appliance when it is in operation. Mendota does not assume or accept any liability
claims for burns or other physical or material damages resulting from touching hot glass surface and hot metal surfaces that
are part of this appliance or other adjacent object such as hearth pads and mantels that may heat up during operation of
this appliance.
Any part(s) found to be defective during the warranty period as outlined above will be repaired or replaced at Mendota’s option
through an accredited distributor, dealer or pre-approved and assigned agent provided that the defective part is returned
to the distributor, dealer or agent for inspection if requested by Mendota. Alternatively, Mendota may at its own discretion
fully discharge all of its obligations under the warranty by refunding the verified purchase price of the product to the
original purchaser. The purchase price must be confirmed by the original Bill of Sale.
The authorized selling dealer, or an alternative authorized Mendota dealer if pre-approved by Mendota, is responsible for all in-
field diagnosis and service work related to all warranty claims. Mendota is not responsible for results or costs of
workmanship of unauthorized Mendota dealers or agents in the negligence of their service work.
At all times Mendota reserves the right to inspect reported complaints on location in the field claimed to be defective prior to
processing or authorizing of any claim. Failure to allow this upon request will void the warranty.
All warranty claims must be submitted by the dealer servicing the claim, including a copy of the Bill of Sale (proof of purchase by
you). All claims must be complete and provide full details as requested by Mendota to receive consideration for evaluation.
Incomplete claims may be rejected.
Unit must be installed according to all manufacturers’ instructions as per the manual by a Mendota authorized dealer, an
authorized dealer technician or an authorized service person only.
All Local and National required codes must be met. The installer is responsible to ensure the unit is operating as designed at the time of installation. The original purchaser is responsible for annual maintenance of the unit, as outlined in the owner’s manual. As outlined below,
the warranty may be voided due to problems caused by lack of maintenance.
Repair/replacement parts purchased by the consumer from Mendota after the original coverage has expired on the unit will
carry a 90-day warranty, valid with a receipt only. Any item shown to be defective will be repaired or replaced at our
discretion. No labor coverage is included with these parts
Exclusions
1. This Limited Lifetime Warranty does not extend to paint, rust or corrosion of any kind due to a lack of maintenance or
improper venting, combustion air provision, corrosive chemicals (i.e. chlorine, salt, air, etc.), door or glass gasketing.
2. Discoloration and some minor warping are normal, not a defect and therefore not covered under this warranty. The
installer must insure the unit is burning as per the rating tag at the time of installation. Over-firing (operation above the
listed BTU rating of this unit can cause serious damage and will nullify this warranty.
3. Mendota will not cover the cost of the removal or re-installation of hearths, facing, mantels or other components.
4. This warranty does not cover dealer travel costs for diagnostic or service work. All labor rates paid to authorized dealers
are subsidized, pre-determined rates. Dealers may charge homeowner for travel and additional time beyond their subsidy.
5. Damages to plated surfaces caused by fingerprints, scratches, melted item or other external sources left on plated surfaces
from the use of cleaners other than denatured alcohol is not covered by this warranty.
Page 83
85-03-01115 DXV35 TIMBERFIRE Page 83
6. Mendota is free of liability for any damages caused by the appliance, as well as inconvenience expenses and materials.
Incidental or consequential damages are not covered by this warranty.
7. Exclusions to this warranty include: injury, loss of use, damage, failure to function due to accident, negligence, misuse,
improper installation, alteration of the manufacturer’s setting of components, lack of proper and regular maintenance,
damage incurred while the appliance is in transit, or by act of God.
8. Malfunction, damage or performance based issues of any and all components as a result of environmental conditions,
location, chemical damages, downdrafts, installation error, installation by an unqualified installer, incorrect chimney
components (including but not limited to cap size or type), operator error, abuse, misuse, use of improper fuels, lack of
regular maintenance and upkeep, acts of God, weather related problems from hurricanes, tornados, earthquakes, floods,
lightning strikes/bolts or acts of terrorism or war, which result in malfunction of the appliance are not covered under the
terms of this Limited Lifetime Warranty.
9. Mendota has no obligation to enhance or modify any unit once manufactured (i.e. as products evolve, field modifications or
upgrades will not be performed on existing appliances).
10. Any unit showing signs of neglect or misuse will not be covered under the terms of this warranty policy and may void this
warranty. This includes units with rusted or corroded fireboxes which have not been reported as rusted or corroded within
three (3) months of installation/purchase.
11. Units which show evidence of being operated while damaged, or with problems known to the purchaser and causing
further damages will void this warranty.
12. Units where the serial no. has been altered, deleted, removed or made illegible will void this warranty.
13. Noises due to minor movement, expansion and contraction of the steel is normal and is not covered under the terms of this
warranty.
14. Freight damages for products or parts are not covered under the terms of the warranty.
15. Products made or provided by other manufacturers and used in conjunction with the Mendota appliance without prior
authorization from Mendota may void this warranty.
Limitations of Liability
The original purchaser’s exclusive remedy under this warranty, and Mendota’s sole obligation under this warranty, express
or implied, in contract or in tort, shall be limited to replacement, repair, or refund, as outlined above. In no event will
Mendota be liable under this warranty for any incidental or consequential commercial damages or damages to property.
To the extent permitted by applicable law, Mendota makes no express warranties other than the warranty specified herein.
The duration of any implied warranty is limited to duration of the expressed warranty specified above. If implied
warranties cannot be disclaimed, then such warranties are limited in duration to the duration of this warranty.
Some U.S. states do not allow limitations on how long an implied warranty lasts or allow exclusion or limitation of incidental
or consequential damages, so the above limitations or exclusions may not apply to you.
Customers located outside the U.S. should consult their local, provincial or national legal codes for additional terms which
may be applicable to this warranty.
How to Obtain Warranty Service
1. If you discover a problem that you believe to be covered by the warranty, you must report to your Mendota Dealer within
30 days, with proof of purchase, purchase date, model name and serial number.
2. Customers should contact the authorized selling dealer to obtain warranty service. In the event the authorized selling
dealer is unable to provide warranty service, please contact Mendota by mail at the address listed below. Please include a
brief description of the problem and your address, email and telephone contact information. A representative will contact
you to make arrangements for an inspection and/or warranty service.
Warrantor: Johnson Gas Appliance Company Mendota Fireplace Division 520 E Avenue NW, Cedar Rapids, IA 52405, USA
Page 84
85-03-01115 DXV35 TIMBERFIRE Page 84
Owner Registration
After installation, Mendota fireplace owners must register with Mendota to qualify for the Lifetime Limited Warranty within 30 days. Product registration will activate your Lifetime Limited Warranty.
Owners should complete the forms available at:
mendotahearth.com/warranty
Note: Your Mendota dealer can assist with warranty applications and information.
Page 85
Page 86
Johnson Gas Appliance Company
520 E Avenue NW
Cedar Rapids, Iowa 52405
Mendota Warranty Registration
Loading...