WARNING
If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal
injury or loss of life.
CAUTION: Keep gasoline and other liquids having flammable vapors away.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not u se an y
phone in your building.
•Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire
department.
WARNING
Do NOT use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control, which has been under water.
AVERTISSEMENT. Quiconque ne respecte pas à la lettre
les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des
dommages, des blessures ou la mort.
ATTENTION. Garder l’essence ou autres liquides produisant des vapeurs inflammables loin del’appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucun interrupteur; ne pas vous servir
des téléphones se trouvant dans le bâtiment.
•Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du fournisseur.
•Si vous ne pouvez rejoindre le fournisseur, appelez
le service des incendies.
N’utilisez pas cet appareil s’il a été plongé dans l’eau,
même partiellement. Faites inspecter l’appareil par un
technicien qualifiéet remplacez toute partie du système
de contrôle et toute commande qui ont été plongés dans
l’eau.
service or maintenance can cause injury or property damage.
Refer to this manual. For assistance or additional information
consult a qualified installer, service agency or the gas supplier.
AVERTISSEMENT : Une installation, un réglage, une modification, une réparation ou un entretien mal effectué peut causer des dommages matériels ou des blessures. Voir la notice
de l'utilisateur quiaccompgne l’appareil. Pour de l’aide oueds
renseignements supplémentaires, consultez un installateur,
un technicien agréé ou le fournisseur de gaz.
Page 2
prop
FOR YOUR SAFETY READ BEFORE LIGHTING
POUR PLUS DE SÉCURITÉ, LIRE AVANTD'ALLUMER
WARNING
Do not operate this appliance with the glass removed,
cracked or broken. A licensed or qualified person
should do replacement of glass.
This appliance must be installed in accordance with
local codes, if any; if none, follow the National Fuel
Gas Code, ANSI Z223.1, or Canadian Installation
Codes, CAN/CGA-B149. Gas and Propane Installation Code, CSA B149.1
This appliance is only for use with the type(s) of gas
indicated on the rating plate and may be installed in an
aftermarket, permanently located, manufactured home
(USA only) or mobile home, where not prohibited by
local codes. See owner's manual for details. This appliance is supplied with a conversion kit.
Caution: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
im
In the Commonwealth of Massachusetts:
• Installation must be performed by a licensed
•
er and dangerous operation.
plumber or gas fitter;
A CO detector shall be installed in the room where
the appliance is installed.
Attention. Ne pas utiliser l’appareil si le panneau fron-
tal en verre n’est pas enplace, est craqué ou brisé.
Confiez leremplacement du panneau à untechnicien
agréé.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence dételés règlements, selon les
codes d'installation ANSI Z223.1, National Fuel Gas
Code ou CAN/CGA-B149 en vigueur.
Cet appareil doit être utilisé uniquement avec le type
de gaz indiqué sur la plaque signalétique. Cet appareil
peut être installé dans une maison préfabriquée ou
mobile (É.-U. seulement) installée à demeure si les
règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne
peut pas être utilisé avecd'autres gaz sauf si une
trousse deconversion certifiée est fournie.
Attention. Au moment de l’entretiennes commandes, étiquetez tous les fil savant de les débrancher. Des erreurs decâblage peuvent
entraîner unfonctionnement inadéquat etdangereux.
CAUTION
THESE INSTRUCTIONS ARE TO REMAIN WITH
THE HOMEOWNER.
Page 3
DXV35 DT3 FEATURES - QUICK REFERENCE INFORMATION
EXTERNAL DIMENSIONS: 35-7/8” Wide X 31-1/2” High X 15-1/2” Deep
MINIMUM FRAMING DIMENSIONS: 37-1/8” WIDE x 31-1/2” HIGH X 16” DEEP
GLASS SIZE: NeoCeram Glass with non-reflective coating. Visible Glass measures 456 in
2
. Actual Glass size is 580 in2.
MANTEL ALLOWANCE: 8” Deep Mantel at 14” Above Top Convection Opening
VENT SYSTEM ALLOWANCE: Top Vent Only. 12” Vertical Minimum with 6” max horizontal. 55 feet Vertical Maximum.
4” exhaust and 6-5/8” combustion air intake coaxial vent pipe required. 12’ maximum horizontal run allowed with 4’ minimum vertical starter section.
VENT DAMPER ADJUSTMENT AVAILABLE: There is one exhaust vent damper included in this unit and located in the
top convection chamber at the center.
CONTROLS: IPI Electronic Ignition System with AC Primary Power and DC Backup Power. Accent light and Blowers operate on AC Power only.
BLOWER SYSTEM: 210 CFM Dual Blower System. 120VAC, 2Amps. Dedicated Hot Power only. No switches, Fan
Speed Controls or Light Dimmers are allowed in same circuit.
Accent Light System: Accent Light System Included. Light can be turned on or off or dimmed using dimmer mounted
behind lower grill.
BURNER SYSTEM: Dual 304 Stainless Steel Tubular burners.
BURNER AIR SHUTTER SYSTEMS: Externally controllable Rear Burner air shutter and Internal rotary Front Burner air
shutter.
LOG SET: 9-piece, Premium Definition Log Set with Extreme glow and realism ember bed.
REFRACTORY PANELS: High Detail Red Clinker Fiber Brick Panels included. Brick Panels required for operation.
NATURAL GAS INFORMATION: Factory equipped for Natural Gas. 4.5”WC Minimum inlet pressure required. For NG
applications, Front Burner Orifice Size is #49 and the Rear Burner Orifice Size is #44.
LPG INFORMATION: LP conversion kit #HA-30-00501 is required. 12”WC Minimum inlet pressure required. For the
DXV35 DT3 LPG application, both front are rear burner orifices are to be drill size 3/64”. For higher altitude, adjustment to
orifice size may be necessary.
INITIAL STARTUP ADVICE
PAINT CURING CYCLE RECOMMENDATION: It is recommended that you run this Fireplace on maximum flame height,
for 3 cycles of 2 hours ON and 2 hours OFF, initially, to cure the paint.
BLOWER BREAK-IN PERIOD: The integrated blowers in this Insert may exhibit some bearing noise and electrical static
noise during the first few days of operation. This is normal during the break-in period. It is recommended that following the
Paint Curing Cycle, the blowers be run at their maximum speed for two 3-hour periods. The burner flames must be on
during these cycles. The blowers in a few fireplaces may take longer to break-in and may require additional operation
time before all extraneous noise is eliminated. Please allow adequate operational time for the blowers to break-in before
you contact your dealer for service.
2
Page 4
TABLE OF CONTENTS
FOR YOUR SAFETY READ BEFORE LIGHTING ................................................................................................................. 1
DXV35 DT3 FEATURES - QUICK REFERENCE INFORMATION .................................................................................... 2
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION .................................................................................. 5
BUILDING PERMIT AND INSTALLATION INSPECTION APPROVAL REQUIREMENTS ................................................... 5
SPECIFIC REQUIREMENTS FOR THE COMMON WEALTH OF MASSACHUSETTS ....................................................... 6
SAFETY AND WARNING INFORMATION ............................................................................................................................. 7
GENERAL INFORMATION ..................................................................................................................................................... 9
SAFETY AND STRUCTURAL CONCERNS ....................................................................................................................... 9
GAS SUPPLY REQUIREMENTS ......................................................................................................................................... 11
GAS SUPPLY LINE SIZING .............................................................................................................................................. 11
GAS PRESSURE CHECKING REQUIREMENTS ............................................................................................................ 11
GAS PRESSURE REQUIREMENTS .................................................................................................................................... 12
GAS PRESSURE REQUIREMENTS ................................................................................................................................ 12
EXTERIOR VENT LOCATIONS AND RESTRICTIONS ....................................................................................................... 13
GENERAL FLUE VENTING INSTRUCTIONS ..................................................................................................................... 14
GENERAL INSTALLATION INSTRUCTIONS ...................................................................................................................... 15
VENTING COMPONENTS LIST ........................................................................................................................................... 21
DOOR REMOVAL AND REPLACEMENT ............................................................................................................................ 24
To Remove Glass Frame: ................................................................................................................................................. 24
To Install Glass Frame: ..................................................................................................................................................... 24
GLASS FRAME ASSEMBLY REPAIR AND REPLACEMENT ......................................................................................... 25
TO REPLACE DAMAGED GLASS ................................................................................................................................... 25
DXV-35 DT3 DEEP TIMBER LOG SET INSTALLATION INSTRUCTIONS ......................................................................... 26
INSTALLATION CHECK OFF LIST ...................................................................................................................................... 37
LIGHTING CHECK OFF LIST ............................................................................................................................................... 37
BEFORE YOU BEGIN .......................................................................................................................................................... 38
3
Page 5
CONTROL PANEL FUNCTIONS IDENTIFICATION ........................................................................................................ 38
OPERATING DURING POWER OUTAGES ..................................................................................................................... 39
THERMOSTAT OR REMOTE CONTROL OPERATION .................................................................................................... 40
HOW TO CONNECT A THERMOSTAT OR WALL SWITCH TO THIS FIREPLACE ...................................................... 40
BLOWER OPERATION AND WIRING .............................................................................................................................. 41
TROUBLE SHOOTING MENDOTA GAS DXV FIREPLACE ................................................................................................ 42
CUSTOMER INFORMATION AND TROUBLE-SHOOTING ................................................................................................ 43
OPERATION DURING POWER OUTAGES ..................................................................................................................... 43
PILOT FLAME AND MAIN BURNER RELATIONSHIP VERIFICATION .......................................................................... 50
PILOT FLAME LENGTH ADJUSTMENT .......................................................................................................................... 50
CHECKING FOR NORMAL BURNER (S) IGNITION CHARACTERISTICS .................................................................... 51
ATTACHING LPG CONVERSION LABELS AND HIGH ALTITUDE DERATION LABEL ................................................ 51
REPLACEMENT PARTS ...................................................................................................................................................... 52
MENDOTA DESIGNER FRONTS INSTALLATION INFORMATION ................................................................................... 53
INFORMATION SPECIFIC TO THE INSTALLATION OF THE ANDOVER, BENTLEY AND PRAIRIE FRONTS................................ 53
INFORMATION SPECIFIC TO THE INSTALLATION OF MILLENNIA GRILLS, VICTORIA AND TUSCANY FILIGREES ................. 54
INFORMATION SPECIFIC TO THE INSTALLATION OF THE WELLINGTON FIRESCREEN FRONT .............................................. 54
ELECTRICAL REQUIREMENTS .... 115 VOLT, LESS THAN 2 amps, Un-switched direct power.
Unit to floor 0 in. Unit to enclosure sidewalls 0.5 in.
Unit to enclosure sidewall 0.5 in. Unit top to ceiling 18 in.
Vent to enclosed 1 in. Wall Pass-Through to framing 1 in.
Vent to adjacent sidewall 10 in. Mantle above discharge air opening 14 in.
High Fire - Adjustable to - Low Fire
REAR BURNER
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
: #44 NAT. GAS [3/64” L.P. GAS] –
78.5% Steady State Efficiency
: GAS INLET: 3/8" N.P.T.at Gas Valve Entry Point
FRONT BURNER
: #49 NAT. [3/64” LP]
•
Certified under ANSI Z21.88 (2005)
Approved or bedroom installations and mobile homes. UL307B approved for "mobile homes, after first sale of
home, not for recreational vehicles."
Gas appliances must be tested and certified by a nationally recognized testing and certification agency to American
National Standards Institute - ANSI Gas Appliance Safety Standards. The Mendota Gas DXV Fireplace has been
tested and certified by Intertek Testing Services 8431 Murphy Drive, Middleton, WI
Fireplace Includes A Sealed Combustion System, 6-Piece Ceramic Fiber Log Set & Coals, Firebrick Lined Firebox, NeoCeram Glass, Piezo Igniter, Dual Blowers, Aga Certified Safety System, And Wall Thermostat.
Options
Fronts, Bentley Arched Doors, Andover Arched Doors & 4 Color Overlay Fronts, Prairie Rectangular Doors & 4 Color
Overlay Fronts, Deerfield Front, Wellington Front, Versiheat Remote Forced Air Heat Transfer System, Versiheat II
Forced Air Heat Transfer System, Thermostats, Remote Control Kits.
Building Permit and Installation Inspection Approval Requirements
: Black, Brass, Classic Brass Or Classic Silver Tone Grill Sets, Black Or 24k Gold "Victoria" & “Tuscany” Filigree
CSA 2-33 (2005) “Vented Gas Fireplace Heaters" not for use with solid fuel.
All installations of Mendota Fireplaces and Inserts must comply with all
the requirements stated in this Installation and Operating Instructions
Manual. The Dealer and/or installer must also obtain all required Building
Permits and Inspection Approval from the local building inspection department or the local body having jurisdiction. In order to validate warranty coverage, Mendota may require facsimile copies of the Building Permit
and Inspection Approval forms. Failure to provide adequate proof that
the installation conforms to all local requirements and the requirements
stated in the Installation and Operating Instructions Manual will void all
applicable warranty.
INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH HOMEOWNER.
5
Page 7
Specific Requirements for the Common Wealth of Massachusetts
The information in this section applies to all installations performed in the Common Wealth of Massachusetts only.
a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure
used in whole or in part for residential purposes and where the side wall exhaust vent termination is less than
seven (7) feet above grade, the following requirements shall be satisfied:
1. If there is no carbon monoxide detector with an alarm already installed in compliance with the most current edition of NFPA 720, NFPA 70 and the Massachusetts State Building code in the residential unit
served by the side wall horizontally vented gas fueled equipment, a battery operated carbon monoxide
detector with an alarm shall be installed in compliance with the most current edition of NFPA 720. NFPA
70 and the Massachusetts State Building Code.
2. In addition to the above requirements, if there is not one already present, a carbon monoxide detector
with an alarm and a battery backup shall be installed and located in accordance with the installation requirements supplied with the detector on the floor level where the gas equipment is installed. The carbon
monoxide detector with an alarm shall comply with 527 CMR, ANSI/UL 2034 Standards or CSA 6.19 and
the most current edition of NFPA 720. In the event that the requirements of this subdivision cannot be
met at the time of the completion of the installation of the equipment, the installer shall have a period of
thirty (30) days to comply with this requirement; provided, however, that during said thirty (30) day period,
a battery operated carbon monoxide detector with an alarm shall be installed in compliance with the most
current edition of NFPA 720, NFPA 70 and the Massachusetts State Building Code. In the event that the
side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the carbon
monoxide detector may be installed on the next adjacent habitable floor level. Such detector may be a
battery operated carbon monoxide detector with an alarm and shall be installed in compliance with the
most current edition of NFPA 720, NFPA 70 and the Massachusetts State Building Code.
3. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally
vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half
(1/2) inch in size, “GAS VENT DIRECTLY BELOW, KEEP CLEAR OF ALL OBSTRUCTIONS”
4. A final inspection by the state or local gas inspector of the side wall horizontally vented equipment shall
not be performed until proof is provided that the state or local electrical inspector having jurisdiction has
granted a permit for installation of carbon monoxide detectors and alarms as required above.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2) (a) 1 through 4:
1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current
edition of NFPA 54 as adopted by the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.
(c) When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting
system design or venting system components with the equipment, the instructions for installation of the
equipment and the venting system shall include:
1. A complete parts list for the venting system design or venting system; and
2. Detailed instructions for the installation of the venting system design or the venting system components.
(d) When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not
provide the parts for venting the flue gases, but identifies “special venting systems”, the following shall be satisfied:
1. The referenced “special venting system” instructions shall be included with the appliance or equipment in-
stallation instructions; and
2. The “special venting systems” shall be Product Approved by the Board, and the instructions for that sys-
tem shall include a parts list and detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equip-
ment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall
remain with the appliance or equipment at the completion of the installation.
6
Page 8
SAFETY AND WARNING INFORMATION
READ and UNDERSTAND all instructions carefully before starting the appliance. FAILURE TOFOLLOW these instruc-
tions may result in a possible fire hazard and will void the warranty.
Any safety screen or guard removed for servicing must be replaced before operating this appliance.
DO NOT USE this appliance if any part has been under water. Immediately CALL a qualified service technician to inspect
the appliance and to replace any part of the control system and any gas control, which has been underwater.
THIS UNIT IS NOT FOR USE WITH SOLID FUEL.
Installation and repair should be PERFORMED by a qualified service person. The appliance and venting system should
be INSPECTED before initial use and at least annually by a professional service person. More frequent cleaning may be
required due to excessive lint from carpeting, bedding, material, etc. It is IMPERATIVE that the unit’s control compartment, burners, and circulating air passageways ARE KEPT CLEAN to provide for adequate combustion and ventilation
air.
Always KEEP the appliance clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
NEVER OBSTRUCT the flow of combustion and ventilation air. Keep the front of the appliance CLEAR of all obstacles
and materials for servicing and proper operation.
Due to high temperature, the appliance should be LOCATED out of traffic areas and away from furniture and draperies.
Clothing or flammable material SHOULD NOT BE PLACED on or near the appliance.
Children and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid
burns or clothing ignition. Young children should be CAREFULLY SUPERVISED when they are in the same room as the
appliance.
These units MUST use one of the vent systems described in the Installing Your Fireplace section of the Installers Guide.
NO OTHER vent systems or components MAY BE USED.
This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel-burning appliance. Each gas appliance MUST USE a separate vent system. Common
vent systems are PROHIBITED.
If the vent-air intake system is disassembled for any reason, reinstall per the instructions provided for the initial installation.
The vent system assembly for this fireplace must be periodically examined by a qualified service agency.
INSPECT the external vent cap on regular basis to make sure that no debris is interfering with the airflow. The flow of
combustion and ventilation air not to be obstructed
DO NOT abuse the glass door by striking the glass, slamming the door shut, etc.
Use only authorized parts and materials obtained from Johnson Gas Appliance Company when replacing defective or
damaged glass.
DO NOT USE abrasive cleaners on the glass door assembly. DO NOT ATTEMPT to clean the glass door when it is hot.
Turn off the gas before servicing this appliance. It is recommended that a qualified service technician perform an ap-
pliance check-up at the beginning of each heating season.
DO NOT place furniture or any other combustible household objects within 36 inches of the fireplace front.
CAUTION: Do not operate the appliance with glass removed, cracked or broken. Replacement of the panel(s) should be
done by a licensed or qualified service person.
7
Page 9
CONGRATULATIONS
You are the owner of a world-class heat producing gas direct vent sealed combustion fireplace.
This elegant, highly efficient Fireplace will be a constant source of comfort and fascination. It will be the focal point of
beauty and interest in your home.
The Mendota Gas Fireplace is a true heating appliance incorporating the traditional aesthetics of fireplace fire viewing
with the controllability and fuel efficiency of a home gas furnace. Of particular interest is the low fuel consumption and brilliant fire viewing afforded by the realistic Premium Fiber wood fire-like combustion system.
Carefully read the following instructions prior to actual installation. Proper Mendota Gas Fireplace installation and operation will give you years of safe, trouble free comfort and enjoyment.
If you have any questions regarding installation or operation of your Mendota Fireplace please contact your local dealer.
CAUTION
Due to high temperatures, the Fireplace should be located out of traffic and away from furniture and draperies. Children
and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing
ignition. Young children should be carefully supervised when they are in the same room as the Mendota Gas Fireplace.
Clothing or other flammable material should not be placed on or near the Fireplace.
Any safety screen or guard removed for servicing an appliance must be replaced prior to operating this appliance.
The Mendota Gas Fireplace is a powerful and efficient heating unit. It has been designed as a major source of supple-
mental heat. As with any mechanical appliance there can be component shut downs. It is advisable to have an alternate
heat supply.
Installation, repair and any adjustments to logs or burner must be done by a qualified service person. The appliance
should be inspected before use and at least annually by a professional service person. More frequent cleaning may be
required due to excessive lint from carpeting, bedding material, carbon build-up, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean. The burner and pilot flames and logs
should be visually checked periodically.
DO NOT use this appliance if any part has been under water or exposed to moisture corrosion. Immediately call a qualified service technician to inspect the Fireplace and replace any part of the control system and any gas control, which has
been under water. DO NOT use this fireplace if the burner does not
proved service person if there is any delay in burner light off.
It is Johnson Gas Appliance Company's policy that no responsibility is assumed by the Company or by any of its employees or representatives for any damages caused by an inoperable, inadequate, or unsafe condition which is the result,
either directly or indirectly, of any improper operation, installation or servicing procedures.
light immediately. Turn unit off and call Mendota ap-
Building Permit and Installation Inspection Approval Requirements
All installations of Mendota Fireplaces and Inserts must comply with all the requirements stated in this Installation and
Operating Instructions Manual. The Dealer and/or installer must also obtain all required Building Permits and Inspection
Approval from the local building inspection department or the local body having jurisdiction. In order to validate warranty
coverage, Mendota may require facsimile copies of the Building Permit and Inspection Approval forms. Failure to provide
adequate proof that the installation conforms to all local requirements and the requirements stated in the Installation and
Operating Instructions Manual will void all applicable warranty.
INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH HOMEOWNER.
HIGH ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher than 7500, please con-
tact the Mendota technical service department for specific venting requirements and venting restrictions.
8
Page 10
GENERAL INFORMATION
Your Mendota Gas Fireplace has a state-of-the-art co-axial direct vent, sealed combustion system. This advanced, highly
efficient system brings in outside air for combustion and efficiently heats and re-circulates room air. The Mendota system
maintains high air quality, maximizes efficiency and assures proper operation in today's "tight" homes.
SAFETY AND STRUCTURAL CONCERNS
This Fireplace must be installed and serviced by a Mendota approved service person. Any adjustments to burner, pilot,
logs or coal bed must
fore relighting pilot. ALWAYS!
be made by a Mendota approved service person. If pilot goes out always wait five (5) minutes be-
VENTING REQUIREMENTS
This Mendota Fireplace can be vented using AMERIVENT, DURAVENT, SELKIRK METALBESTOS, SECURITY
CHIMNEY and ICC brands of coaxial pipe off the top. Use only Mendota specified vents and vent caps when installing
your fireplace. Closely follow venting locations, directions and requirements. Observe the restrictions relating to vent position on exterior of home (see PG. 13). Be sure all vent pipe sections are fully twist-locked and leak-proof. Be sure Milpak Sealant is used on the inner pipe joints of all Simpson DuraVent pipe components and all adjustable pipe sections
manufactured by Simpson DuraVent and American Metals.
REMOVE THE GLASS WHEN LIGHTING THE PILOT FOR THE FIRST TIME
flame must travel promptly and smoothly around "curves" and light entire burner. The flame must not
. The burners must light immediately & the
"lift" off burners.
DO NOT operate unit if burner does not light immediately or if flame lifts off burner.
This Mendota Direct Vent Fireplace may be placed within inches of adjacent sidewalls. (See Figure 4: Specifications &
Clearances). The fireplace may be placed directly on concrete or wood flooring. If the appliance is to be installed on
carpeting, vinyl or other combustible material other than wood flooring, the appliance shall be installed on a metal or wood
panel extending the full width and depth of the appliance. Combustible mantels may be installed above top of the heat
outlet grills. How far out the mantel may protrude past the front face of this appliance is dependent on the distance from
upper grill. See Figure 4: Specifications & Clearances. Non-combustible (marble, brick, stone, etc.) mantels or mantels
with steel protector plate on underside can be installed at any desired height above upper grill.
Never block upper or lower grills. Always use Mendota grills and Mendota approved vent systems and vent caps.
A non-combustible hearth protector is required and must extend a minimum of 12" in front of the fireplace. If
fireplace is raised off floor 6" or more, no hearth protector is required.
HEATING PERFORMANCE
Mendota Gas Built-in Fireplaces are true, high efficiency gas heaters. With its high heat output the Mendota Fireplace will
heat a large area of your home if situated to maximize heat circulation. Air movement options for maximizing heat circulation, which can be considered, are through-the-wall grills or floor grills, the continuous operation of central heating furnace
blowers, or ceiling fan. The most efficient method for overall heat distribution is a ceiling fan. The heat output of
the Fireplace can be reduced by up to 23,000 BTUH by slowly turning the Hi/Lo temperature knob on the gas valve counter clockwise from "Hi" to "Lo" and also turning OFF the rear burner using the Rear Burner ON/OFF Switch. Blower can
also be turned down to reduce heat output.
AESTHETIC CONSIDERATIONS
Burning or static fireplaces are a major aesthetic focus in any room. Locate your gas fireplace as you would a television
set. The Mendota Hearth Gas Fireplace will be a continuing source of comfort and fascination. Corner installations will
afford you the greatest potential for viewing in many rooms.
We suggest installing the Mendota Fireplace 6 to 12 inches above the floor by utilizing an elevated hearth.
ELECTRICAL REQUIREMENTS
A 115-volt electrical service must be supplied at the fireplace location at the time of installation. It must be electrically
grounded in accordance with local codes or in their absence with current edition of the National Electric Code ANSI/NFPA
70. Electrical Service may enter this appliance at the Left Side Junction Box or the Right Side Junction box. The Two integrated junction boxes are internally wired at the factory. Do not disconnect factory installed wiring at either junction box.
Power supply to blower must be continuous. DO NOT use switches or speed control devices in power supplied to fireplace.
The blower on this appliance is equipped with a three-prong plug for protection against shock hazard and should be
plugged directly into the grounded three-prong receptacle provided with the fireplace. Do not cut or remove the grounding
prong from the plug. NOTE: The blower output can be adjusted with the rheostat. There will be delays in blower operation during "heat-up" (approx. 15 min.) and extended blower operation during "cool-down" (approx. ½ hr.) of unit.
Thermostat wire may be connected to this appliance. Use only a Millivolt Rated thermostat (Standard or Set-back type).
Thermostat wire is to be run from desired thermostat location to the Main Burner Switch (located behind Courtesy Panel).
See Page 39.
9
Page 11
VENT OPTIONS DISCUSSION
This Mendota Fireplace can be vented using AMERIVENT, DURAVENT, SELKIRK METALBESTOS, SECURITY
CHIMNEY and ICC brands of coaxial pipe off the top. Use only Mendota specified vents and vent caps when installing
your fireplace. Closely follow venting locations, directions and requirements provided in this Manual. Observe the restrictions related to vent position on exterior of home (see PG.13).
Make certain that all vent pipe sections are fully twist-locked and leak-proof. Note: When using Dura-vent pipes it is recommended that you use a silicate stove masonry sealant [Milpak Sealant #65-06-00909] on all inner pipe joints. On the
exterior (air intake) pipe joints, high temperature foil tape may be used instead of the masonry sealant. Contact your
dealer to obtain this sealant material.
TOP VENTING
The DXV-35 Fireplace comes from the factory configured for venting off the top using 4” x 6-5/8” Coaxial Vent Pipes.
AMERIVENT, DURAVENT, SELKIRK METALBESTOS, SECURITY CHIMNEY and ICC brand pipes and venting components may be used when venting off the top.
Venting off the top on the DXV-35 Fireplace provides a large degree of flexibility for many venting configurations. However, a few critical limitations must be understood and adhered to.
Limitation 1:
Limitation 2
A 12” minimum vertical pipe section must be connected to the top starter collar of the DXV-35. With the
12” vertical section connected, you may only install one 90-degree elbow and a run a maximum 6” horizontal pipe section before connecting the horizontal vent cap.
: The maximum horizontal run allowed when venting off the top is 12 feet preceded by a minimum 4 feet
vertical run. This 12 feet horizontal run can only be used if a straight vertical run of 48 inches (4 feet) is
connected directly to the top of the dxv35. Do not exceed the maximum 12 feet horizontal run. Even if
the vertical section you installed is greater than 4 feet, do not exceed the 12 feet maximum horizontal
run throughout the entire vent system
10
Page 12
GAS SUPPLY REQUIREMENTS
Correct gas pressure and proper gas supply line sizing is imperative to the successful performance of your Mendota gas
fireplace. Be sure the gas supplier or plumber carefully checks for correct gas pressure and gas line sizing when installing the fireplace.
It is critical to carefully check for gas leaks when hooking up the fireplace -- check with soap & water solution.
Be sure to install "approved" flex gas line with brass-to-brass fittings to prevent gas leaks at connections.
Gas supply piping must include a drip leg to eliminate the possibility of contaminants entering the gas train.
Adhere strictly to local and national codes for entire installation.
GAS SUPPLY LINE SIZING
The Mendota Gas Fireplace comes equipped with a 12” flexible connector kit including a manual shutoff ball valve. Gas
supply piping must enter the Fireplace cabinet from the right side.
The included manual shut-off valve meets Federal Codes. I required by local codes, install an additional manual shutoff
valve upstream of the fireplace’s manual shutoff valve. The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess
of ½
PSIG (3.5 kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during
any pressure testing of the gas supply piping system at test pressures equal to or less than
1/2 PSIG (3.5 kPa).
A proper gas line diameter must be selected to run from the supply regulator to the Fireplace. Refer to the following table
for proper gas pipe diameters. Strictly adhere to the correct pipe sizes. If in doubt, use the next larger size.
NOTE: Some areas allow copper tubing or galvanized pipe - check with local approval agencies and codes. NEVER use plastic
pipe.
GAS PRESSURE CHECKING REQUIREMENTS
Inlet and manifold gas pressure checking taps are located on gas valve (see Figure 1 on Page 10). A qualified installer
should use these fittings for setting the correct gas pressure during initial installation.
NOTE: DO NOT DAMAGE OR KINK THE FLEX CONNECTOR. CHECK FOR GAS LEAKS WITH SOAP AND WATER
SOLUTION.
NOTE: 3/8" FLEX OR RIGID PIPING MAY BE USED TO CONNECT GAS SUPPLY TO UNIT DEPENDING ON STATE
AND LOCAL CODES.
NOTE: BE SURE TO INSTALL FLEX GAS HOSE WITH BRASS-TO-BRASS FITTINGS TO PREVENT LEAKS AT
CONNECTION.
NOTE: THE HARD PLUMBING FITTING PROVIDED IS TO BE USED WITH INSTALLATIONS REQUIRING HARD
PLUMBING. IT MAY BE REMOVED IF THE FIREPLACE IS BEING INSTALLED WITH A FLEXIBLE
CONNECTOR.
11
Page 13
GAS PRESSURE REQUIREMENTS
A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS APPLIANCES CAN BE IMPROPER GAS PRESSURE!
Problems such as changes in flame color or flame height, pilot or burner outages, intermittent operation,
changes in heat output, excessive burner noise, etc. are nearly always the result of changes in gas pressure or
improper gas pressure at the time of the installation. The most important item to check during the installation
and the first thing to check when problems occur is gas pressure!
Gas supplies normally enter a residence at 1/2 PSI (13" - 15" W.C.) (3. KPA). A regulator is then placed inside
the residence, which drops this pressure to 7" W.C. (1.8 KPA) (Nat. Gas). This "inches to inches" regulator is
of adequate capacity to service the gas appliances (such as dryer, furnace, etc.). If this regulator's capacity is
not sufficient to add the Gas Fireplace, an additional "inches to inches" regulator must be installed for the Fireplace. EXCEPTION: Some codes allow 2-PSI (1.4KPA) supplies to enter the residence, in which case
"pounds to inches" regulators are used.
The following table provides information on correct gas pressure requirements. Be sure your gas supplier or
plumber carefully follows this table.
GAS PRESSURE REQUIREMENTS
DESIRED
INLET
PRESSURE
MINIMUM
INLET
PRESSURE
MAXIMUM
INLET
PRESSURE
MANIFOLD
OUTLET
PRESSURE
AIR SHUTTER
POSITION*
NATURAL GAS 7.0" W.C.
(1.75 kPa)
L.P. GAS 12.0" W.C.
(3.00 kPa)
TURN GAS VALVE KNOB TO "HIGH" POSITION. GAS PRESSURES MAY VARY PLUS OR MINUS 5%.
5.0" W.C.
(1.12 kPa)
11" W.C.
(2.75 kPa)
11" W.C.
(2.61 kPa)
13.0" W.C.
(3.24 kPa)
3.5" W.C.
(0.87 kPa)
10.0" W.C.
(2.5 kPa)
1/16 - 3/16 "
OPEN
1/4" OPEN-MIN.
NOTE: For High Altitude (Above 5.000 Feet) Some Variations In Air Shutter Settings May Be Required.
Manifold pressure must
be taken at the Output Pressure tap and inlet pressure at the Inlet Pressure tap with the burner
operating by a qualified installer (see Figure 1: Gas Pressure Test Port).
Figure 1: Gas Pressure Test Ports
OUTLET
PRESSURE
TAP
INLET
PRESSURE
TAP
12
PRESSURE
REGULATOR
Page 14
EXTERIOR VENT LOCATIONS AND RESTRICTIONS
Figure 2: Exterior Vent Locations
∨ -
Vent Terminal
ALL MEASUREMENTS GIVEN ARE FROM THE CENTER LINE OF VENT CAP
∧ -
Air Supply Inlet
≡ -
Area where terminal is not permitted
A = Clearance above grade, veranda, porch, deck, or
B = Clearance to window or door that may be opened
(*12 inches (30 cm) minimum.
C = Clearance to permanently closed window (mini-
mum 12 inches (30 cm).
D = Vertical clearance to ventilated soffit located above
the terminal from the center-line of the terminal (12
inches (30 cm) minimum) Vinyl surfaces require
24” min.
E = Clearance to unventilated soffit (18 inches (46 cm)
minimum) Vinyl surfaces require 24” min.
F = Clearance to outside corner - 6 inches (15 cm). M = Clearance under veranda, porch, deck, or balcony (*18
G = Clearance to inside corner - 12 inches (30 cm).
Vinyl surfaces require 24” min.
H = *Not to be installed above a meter/regulator assembly
within 3 feet (90 cm) horizontally from the center-line of
the regulator
I = Clearance to service regulator vent outlet (*6 feet (1.8m)
minimum)
J = Clearance to non-mechanical air supply inlet to building
or the combustion air inlet to any other appliance.
*12 inches (30 cm) minimum.
K = Clearance to a mechanical air supply inlet (*6 feet (1.8 m)
minimum)
L = † Clearance above paved side-walk or a paved driveway
located on public property (*7 feet (2.1 m) minimum)
inches (30 cm) minimum ‡)
N= Minimum 24” horizontal clearance to any surface, such
as an exterior surface, for vertical terminations.
† A vent shall not terminate directly above a sidewalk or paved driveway, which is located between two single-family
dwellings and serves both dwellings.
‡ Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
* As specified in CGA B1:19 Installation Codes (1991). Note: Local codes or regulations may require different clear-
ances.
13
Page 15
GENERAL FLUE VENTING INSTRUCTIONS
The Mendota Fireplace must be vented using Amerivent, Duravent, Selkirk Metalbestos, Security Chimney or ICC Brand
venting systems. All warranties will be voided and serious fire, health or other safety hazards may result from any of the
following actions: Installation by unauthorized personnel; installation of any damaged component; unauthorized modification of vent system; installation of any components not approved by Mendota; failure to meet all clearance requirements;
failure to properly twist-lock and positively seal all components. Consult local building codes before beginning the installation.
WARNING
Always maintain required clearances (air spaces) to combustibles to prevent a fire hazard. Do not fill air spaces with insulation. Check installation instructions for minimum clearance requirements between the outer walls of the vent pipe and
nearby combustible surfaces. Be sure to check the vent termination clearance requirements from decks, windows, soffits,
gas regulators, air supply inlets, and public walkways, as specified in these installation instructions and local building
codes. SAFETY PRECAUTIONS FOR THE INSTALLER: 1) Wear gloves and safety glasses for protection; 2) Exercise
extreme caution when using ladders or on rooftops; and 3) be aware of electrical wiring locations in walls and ceilings.
The gas appliance and vent system must be vented directly to the outside of the building, and never attached to a chimney serving another solid fuel or gas burning appliance. Each direct vent gas appliance must have its own separate vent
system. Common vent systems are prohibited.
To assure proper venting performance of the high-performance Mendota Direct Vent Fireplace, it is critical that all brands
of vent pipe sections are sealed tightly and leak-proof. This means that all pipe sections must be carefully rotated into the
fully "twist-locked" position.
We Strongly Recommend That Fixed Length Pipe Sections Be Used In Place Of Telescoping Sections Whenever
Possible.
Note: When using vent pipe and components that do not incorporate a fiberglass or graphite gasket at the joints, it is recommended that you use Milpak 1000F silicate stove sealant (#65-06-00909). High temperature foil tape may be used on
the outer (air intake) pipe joints.
DO NOT
ASSEMBLIES.
VENT COMPONENTS "TWIST-LOCK" CONNECTION PROCEDURE
SEPARATE ADJUSTABLE TELESCOPING SECTIONS. THEY MUST BE USED AS COMPLETE
DuraVent and American Metals pipe and fittings are designed with special twist-lock connections. Twist-lock
procedure is as follows: four (4) indentations, located on the female ends of pipes and fittings are designed to
slide straight in to the male ends of the adjacent pipes and fittings, by orienting the four pipe identifications so that they match and slide into the four entry slots on the male ends (Figure 3).
Push the pipe sections completely together then twist-lock one section
clockwise, approximately ¼ turn until the two sections are fully locked. The
female locking lugs will not be visible from the outside on the black pipe or
fittings. They may be located by examining inside of the female ends
.
14
Figure 3: Twist-Lock Piping
Page 16
GENERAL INSTALLATION INSTRUCTIONS
CAUTION: Each installation must conform to all local, state and national codes. Refer to the national fuel gas code and local zoning
and code authorities for details on installation requirements. The Mendota Fireplace must be vented to the outside in accordance with
the latest edition of the National Fuel Gas Code. In the absence of local codes, the installation must conform to the most current edition of the National Fuel Gas Code ANSI Z223.1, also known as NFPA 54. NOTE: The Mendota DXV Fireplace is approved for mobile home and bedroom installations.
CAUTION: The Mendota DXV Fireplace may be installed in a manufactured (mobile) home after the first sale of the home. Manufactured home (mobile home) installation must conform with the Manufactured Home Construction and Safety Standard, Title 24
CFR, Part 3280, or, when such a standard is not applicable, the Standard for Manufactured Home Installations, ANSI A225.1/NFPA
501A, or CSA Z240.4-Gas Equipped Mobile Housing. Consult your local building official. Note: For mobile home installations unit
must be bolted to the floor and properly grounded.
This Fireplace must be installed by a qualified service person.
1.
After selection of the desired fireplace location, prepare the rough opening using framing dimensions on PAGE 164.
Be sure to also prepare opening to allow for co-axial vent (see "Flue Venting Instructions".
2. Check to make certain all venting requirements and clearances are being followed.
3. The Fireplace is designed to be installed into rough framing. The drywall will cover the adjustable nailing flanges on
the Fireplace sides. Before sliding the Fireplace into the framed opening, adjust the nailing flanges to accommodate
the thickness of the wall material. NOTE: FRAMING MATERIALS LOCATED ABOVE FIREPLACE BODY MUST
MAINTAIN CORRECT CLEARANCES TO VENT PIPE.
WARNING
DO NOT COVER THE 2” BLACK FRONT SURFACE OF THIS UNIT IF YOU INTEND TO USE THE ANDOVER,
BENTLEY, DEERFIELD or WELLINGTON TRIMS!!
4. Slide Fireplace into the rough framed opening. When finishing the unit, combustible materials may overlay nailing
flanges and come in contact with the edges of the black front surface, but may not
overlap the 2" black front sur-
face. Noncombustible material, such as marble, stones or brick, can be installed over the 2" black surface, only if
you are certain that a Deerfield Front, Andover Front, Bentley Front, Prairie Front or a Wellington Front is
NOT going to be used as the optional trim, up to the inside edge of black frame (next to glass). ROUGH
FRAMING CAN COME NO CLOSER TO UNIT THAN THE STAND-OFFS.
5. Level the Fireplace and secure into opening by nailing through the nailing flanges on cabinet side panels. Holes
are provided in fireplace floor behind grill to secure fireplace to floor using lag screws or drywall screws, if required.
NOTE: A removable panel in the enclosure for future visual inspection of flue connection is recommended.
6. Have an electrician install a 115-Volt supply to the junction box on lower left side of the fireplace cabinet. Connect
wires to the duplex outlet. This duplex outlet is removable from outside of cabinet for easy wiring. Make sure the
outlet is properly grounded and that the installation conforms to all local and national wiring codes.
7. Have gas supplier or qualified plumber install gas supply line to fireplace and connect to gas nipple. Be sure Gas
Supply Requirements (see PG. 9-10) and all local and national codes are carefully followed.
IMPORTANT: Any safety screen, guard, glass or grills removed for servicing a fireplace/room heater must be replaced
prior to operating the fireplace/room heater.
BLOWER OPERATION
This fireplace is designed so the blower operates continually when the body is of this fireplace is hot and the main
burner(s) are on. The blower output can be regulated with the included blower speed control rheostat. NOTE: There
will be a delay before the blower operates during "heat-up" (approx. 15 minutes) and extended blower operation during
"cool-down" of unit (approx. ½ hour).
OPERATION DURING POWER OUTAGES
The fireplace is designed to operate during power outages for 1-1/2 continuous hours, Maximum. The blower will not
operate, but natural convection can be improved by removing the upper grill and opening the screen doors (depending
on the type of optional front installed). After 1-1/2 continuous hours of operation, during the power outage, turn off the
burners for 1 hour and allow the fireplace to cool down. Consecutive 1-1/2 hour burn and 1 hour cool down cycles are
allowed.
15
Page 17
WARNING
MENDOTA DXV-35 GAS DIRECT VENT FIREPLACE
SPECIFICATIONS & CLEARANCES
: Do not cover the 2” faceplate border of the unit with combustible materials.
26 1/2
37 7/16
6"MIN.
1"MIN.
22 5/16
11 1/8
10 3/4
4 1/2
15 3/8
35 7/8
"
10
45°
Adjacent Walls:
A wall, perpendicular to and in front of the appliance front
facing must be at least 10" from the firebox opening. A
wall at 45° to the front and starting at the appliance's
outer edge is permitted. Projections behind this wall (shaded
area) are permitted.
31 7/16
41
27
IF MANTEL IS MADE OF A NON-COMBUSTIBLE MATERIAL
(BRICK, STONE, ETC..), OR HAS A STEEL PROTECTOR PLATE
ON THE UNDERSIDE IT MAY BE PLACED ANYWHERE ABOVE GRILL
MINIMUM FRAMING DIMENSIONS
FOR THIS FIREPLACE
28 3/8
32 5/8
31-1/2
(800 mm)
37 1/8
(943 mm)
16
(407 mm)
16 1/16
HEIGHT
WIDTH
DEPTH
8" COMBUSTIBLE MANTEL
36 1/4 TO SCREW HEADS
1/2 TO
2 1/2
1 15/16
Figure 4: Specifications & Clearances
31 11/16
52 1/2
COMBUSTIBLE MANTEL
TRIANGULAR AREA. FOR
MANTEL DEPTH, INCREASE
1
BY 2". MANTEL MAY BE LOWERED
DECREASED IN THE SAME MANNER
2
8" MANTEL
DEPTH (WIDTH)
REQUIRED
14" MANTEL
HEIGHT FOR
8" MANTEL
4 21/32
GAS INLET
12
14
NON-COMBUSTIBLE
HEARTH PROTECTOR
NOTE:
FOR EVERY 1" THE FIREPLACE IS RAISED OFF THE FLOOR,
HEARTH PROTECTOR MAY BE REDUCED BY 2".
IF FIREPLACE IS RAISED 6" OR MORE, NO HEARTH PROTECTION IS REQUIRED.
MUST REMAIN IN THIS
EVERY 1" INCREASE IN
HEIGHT ABOVE GRILL
2" MIN.
1"
MIN.
2 7/16
85-03-00458
16 1/4
IF DEPTH IS
16 1/4 MIN.
FROM TOP
OF UNIT
TO STACK
CENTER
49 1/2" MIN.
CLEARANCE TO
COMBUSTIBLE
ABOVE UNIT
& MINIMUM
CEILING H E I GHT
NOTE: For L.P. & High Altitude (above 4,000 ft. but below 7500 ft.), 45º elbows must be used in place of 90º elbows.
For Installation At Altitudes Above 7,500 Feet, First Call Mendota Technical Hotline For Further Information On The Strict
Requirements For Installations At These Altitudes.
o
Using 45
elbows in place of a 90o elbow requires 22" minimum opening to center.
CAUTION: If 90ºelbows must be used with LP or at high altitudes, a 3-foot
off the top of the fireplace.
NOTE: 12” MINIMUM VERTICAL PIPE CAN BE USED IF NO HORIZONTAL VENT SECTIONS GREATER THAN 6” (or
7”) ARE USED. ALL OTHER INSTALLATIONS MUST FALL WITHIN ABOVE SHADED AREA.
NOTE: FOR LPG AND HIGH ALTITUDE
APPLICATIONS, SEE PAGE 1 9.
18
Page 20
L.P. GAS MINIMUM HEIGHT HORIZONTAL TERMINATION
L.P.
GAS OR HIGH ALTITUDE (ABOVE
WALL THIMBLE
REQUIRED
6" COAX VENT
45° COAX VENT
45° COAX VENT
(MIN.)
4,000
FT.
BUT BELOW 7500 FT.)
TERMINATION CAP
12" COAX VENT
(MIN.)
85-03-00531
15 1/2"
22"
(MIN.)
49 1/4"
(MIN.)
Figure 7: LP MINIMUM VENT
For L.P. gas and high altitude installations (above 4,000 ft.), 45° elbows must be used in place of 90° elbows.
NOTE: This requires 22” minimum
height to center of vent cap.
CAUTION: If 90° elbows must be used, a 24 inch
vertical starter section must be used off the top of the fireplace.
19
Page 21
MINIMUM RISE THROUGH-THE-WALL VENTING
The minimum vertical rise for vent installation through the wall is 16 1/4" from the top of the fireplace to the centerline of
the 90ºelbow in installations where only a 6” (or 7”) horizontal vent section is used (refer to chart on PG.16 when using
horizontal sections). NOTE: We recommend always using the most vertical rise the installation will allow. This maximizes efficiency and flame appearance. This is especially true for LP gas installations and for installations at higher altitudes.
Use "fixed" pipe sections in place of adjustable pipe sections wherever possible. 1000º sealant use is recommended on
inner pipe joints. Always maintain 1" clearances from vent pipe sides and bottom to combustibles, 3" above pipes on horizontal runs and above elbows. Do not fill air spaces with insulation or other material.
For L.P. gas and High Altitude (above 4,000 ft.), 45º elbows must be used in place of 90º elbows.
NOTE: This requires 19" minimum
vertical starter section must
THIS FIREPLACE MUST BE INSTALLED BY A QUALIFIED MENDOTA APPROVED SERVICEPERSON.
IMPORTANT: REFER TO DRAWINGS ON PAGES 14-17 WHILE FOLLOWING THESE INSTRUCTIONS.
1. Position fireplace in desired location. See PG. 11 for guidelines on proper vent cap placement on the exterior of
home. Check to determine if wall studs are in the way when venting system is attached. If this is the case, you may
want to adjust the fireplace location.
2. Measure from the top of the fireplace up minimum (see Figure 4: Specifications & Clearances, PG. 164) and mark
wall directly at the center of where the vent pipe will penetrate the wall.
3. Cut and frame a 9" wide x 10" high rectangle opening in the wall. The hole must be positioned so the vent system will
run level or have a ¼" rise AND be perpendicular to the wall. The height of the opening must be located to meet all
local and national building codes and not allow the termination to be easily blocked or obstructed. If wall being penetrated is non-combustible material, i.e. masonry block, brick, etc., a 7-inch diameter hole is acceptable.
be used directly off the top of the fireplace.
rough opening depth (see PG. 15). CAUTION: If 90º elbows must be used, a 3-foot
:
4. Assemble the components to the fireplace adapter with pipe seams oriented toward the wall or floor -- as much out of
view as possible. Be sure all vent component connections are in their fully twist-locked position and are leak-proof.
Be sure 1000ºsealant is used on the inner pipe joints of all pipe sections manufactured by Simpson DuraVent. American Metal pipe joints do not require this sealant.
NOTE: DO NOT SEPARATE TELESCOPING SECTIONS. THEY MUST BE USED AS COMPLETE ASSEMBLIES.
5. The length of the horizontal piece that fits through the wall will be determined by the thickness of the wall. When installed, the end of the horizontal piece must be flush with the exterior wall of the home. There MUST be a minimum
of 1" air space clearance to combustibles from all vent pieces (3" above horizontal runs and on top of elbows).
6. A wall thimble must always be used when penetrating combustible wall materials.
NOTE: Combustible wall thickness must
special protection. Contact Mendota Technical services for assistance.
7. From the exterior of the home, slide the horizontal vent cap over the end of the horizontal pipe and tightly secure the
cap to the wall with screws. Seal with a high quality caulking.
WARNING
: Venting terminal shall never be recessed into wall cladding or siding. Vent Cap must sit on top of siding or
cladding.
be 4" to 8" maximum for the wall thimble. Wall more than 8” thick will require
20
Page 22
VENTING COMPONENTS LIST
MENDO TA #DESCRIPTION
45-01-001867" LENGTH
45-01-0018712" LENGTH
45-01-0018824" LENGTH
45-01-0018936" LENGTH
45-01-0019048" LENGTH
45-01-00191ADJUSTABLE LENGTH
45-01-0019245 DEG. ELBOW
45-01-0019390 DEG. ELBOW
45-01-00194WALL THIMBLE
45-01-00195VERTICAL CAP
45-01-00196HORIZONTAL CAP
45-01-0019714" SNORKEL CAP
45-01-0019836" SNORKEL CAP
45-01-00199WALL STRAP
45-01-00200FIRESTOP SUPPORT PLATE
45-01-00201FLASHING: 0/12-6/12 PITCH
45-01-00202FLASHING: 6/12 - 12/12 PITCH
45-01-00203STORM COLLAR
45-01-00204ATTIC INSULATION SHIELD
45-01-00206CO-LINEAR APPLIANCE ADAPTOR
45-01-00207CO-LINEAR TOP KIT
45-01-00208VERTICAL KIT
45-01-00209HORIZONTAL KIT
45-01-00210HORIZONTAL KIT #2
45-01-002117" LENGTH- BLACK
45-01-0021212" LENGTH - BLACK
45-01-0021324" LENGTH - BLACK
45-01-0021436" LENGTH - BLACK
45-01-0021548" LENGTH - BLACK
45-01-00216ADJUSTABLE LENGTH - BLACK
45-01-0021745 DEG. ELBOW - BLACK
45-01-0021890 DEG. ELBOW - BLACK
45-01-00219FACEPLATE, CEILING SUPPORT/ WALL THIMBLE - BLK
45-01-00220ROOF SUPPORT - BLACK
45-01-0022436" LENGTH
45-01-0022548" LENGTH
45-01-00226ADJUSTABLE LENGTH
NOTE: ALL PART NUMBERS LISTED ABOVE APPLY TO SIMPSON DURAVENT COMPONENTS ONLY.
21
Page 23
ELEVATED VERTICAL RISE THROUGH-THE-WALL VENTING
The required MINIMUM vertical rise is 48 in. when used with a maximum horizontal run of 12 ft. For other venting configurations within these maximum limits, see Figure 6, PG. 18.
NOTE: All horizontal runs of vent pipe must be level or have a ¼" rise for every 1' of run toward the termination.
Never allow the vent to run downward. This will cause high temperatures and the possibility of a fire.
USING OFFSETS AND RETURNS: A single 90º vertical-to-horizontal elbow is already calculated into the allowable
maximum 12' horizontal run. Each additional 90º elbow reduces the maximum horizontal distance by 3'. Example: by
using three total 90º elbows the maximum horizontal distance has been reduced to 6 ft. (3 - 1 = 2 elbows x 3' = 6'; 12’
Max. - 6' of elbows = 6' of horizontal run). Note: 45º elbows reduce the maximum horizontal distance by 1½ '.
SUPPORT: Horizontal runs of pipe will require one vent support for every 3 ft. of pipe.
CAUTION: If a vertical-to-horizontal elbow is enclosed within a wall, floor or ceiling, a top air space clearance of 3" must
be maintained above the elbow. Be sure to maintain 1" air space to any combustibles on the sides and bottom, 2" above
horizontal pipe sections.
THIS FIREPLACE MUST BE INSTALLED BY A QUALIFIED MENDOTA APPROVED SERVICEPERSON.
IMPORTANT: REFER TO DRAWINGS ON PAGES 14-17 WHILE FOLLOWING THESE INSTRUCTIONS.
1. Position fireplace in desired location. See PG. 13 for guidelines on proper vent cap placement on exterior of
home. Check to determine if wall studs are in the way when vent system is attached. If this is the case you may
want to adjust the fireplace location.
2. Locate the position where vent pipe will pass through any ceilings and will penetrate the outside wall. Since vent
pipe sections "overlap" we suggest pre-assembling and measuring the total vent pipe run so you can more accurately locate the point where the vent pipe will penetrate the outside wall (See Figure 2: Exterior Vent Locations,
PG. 13). Be sure all vent components are properly twist locked and leak-proof. It is recommended that 1000º
sealant be used in the inner pipe joints of all pipe sections manufactured by Simpson DuraVent.
NOTE: DO NOT SEPARATE TELESCOPING SECTIONS. THEY MUST BE USED AS COMPLETE ASSEMBLIES.
3. Cut and frame a 9-1/2” wide x 10” high openings in the outside wall openings and 9” x 9” opening in ceiling open-
ings. The outside wall hole must be positioned so the vent system will run level or have a ¼" on rise AND
pendicular to the wall. The height of the opening must be located to meet all building codes and not allow the
termination to be easily blocked or obstructed. A ceiling fire stop spacer is required at all floor (ceiling) penetrations.
4. Connect vent pipe to the fireplace adapter on top of fireplace vent outlet.
5. The horizontal pipe must end flush with the exterior wall of the home. Horizontal pipes will require proper support
every 3 ft. of vent pipe. THERE MUST BE A MINIMUM OF 1" CLEARANCE TO COMBUSTIBLES ON THE
SIDES AND BOTTOM OF ALL VENT PIECES (3" above horizontal runs and above elbows).
6. A wall thimble must always be used when penetrating combustible wall materials.
NOTE: Combustible wall thickness must
be 4" to 8" maximum for the wall thimble. Wall more than 8” thick will
require special protection. Contact Mendota Technical services for assistance.
7. From the exterior of the home, slide the horizontal vent cap over the end of the horizontal pipe and tightly secure
the vent cap to the wall with screws. Seal with high quality caulking.
WARNING
: Venting terminal shall never be recessed into wall cladding or siding. Vent Cap must sit on top of sid-
ing or cladding.
be per-
22
Page 24
VERTICAL THROUGH-THE-ROOF VENTING
The
maximum vertical run of vent pipe is 55 ft. from the top of the fireplace. The fireplace will support a run of a maximum of 55 ft. The vent system must be supported every 3 feet using Support Straps. Maintain 1" air space clearances on
all sides of vent components that are positioned vertically and 3” above horizontal pipe sections and components.
THIS FIREPLACE MUST BE INSTALLED BY A QUALIFIED MENDOTA APPROVED SERVICEPERSON.
IMPORTANT: REFER TO DRAWINGS ON PAGES 14-17 WHILE FOLLOWING THESE INSTRUCTIONS.
1. Place the fireplace in its desired location. Drop a plum bob from the ceiling to the position of the fireplace flue exit.
Mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plum bob from
the roof to the hole previously drilled in the ceiling. Mark and drill the spot where the vent will penetrate the roof. Determine if ceiling joists, roof rafters or other framing will obstruct the venting system. You may choose to relocate the
fireplace or choose to offset the vent system to avoid cutting load bearing members.
2. Cut and frame a 9" x 9" opening in the ceiling centered on the hole drilled in Step 1.
3. To determine the length of the vent pipe required, measure the distance from the fireplace flue outlet to the ceiling,
the ceiling thickness, and the vertical rise in the attic or second story and allow sufficient vent height above roofline.
For two story installations, fire stops are required at each floor level. If an offset is needed in the attic, additional pipe
and elbows will be required.
4. Assemble the desired lengths of vent pipe and elbows to reach from the fireplace flue outlet. Ensure that all vent pipe
and elbow connections are in their fully twist-lock position and that inner pipe joints are sealed and are leak-proof.
Maintain 1" airspace clearances to combustibles around vertical pipe sections and 3" clearance above horizontal run
sections.
5. Cut a 9" x 9" opening in the roof, centered in the small drilled hole placed in the roof in Step 1. The opening should
be a sufficient size to meet all clearance requirements. Continue to assemble lengths of pipe and elbows necessary
to reach up through the roofline. Galvanized pipe and elbows may be utilized in the attic, as well as above the roofline. The galvanized finish is desirable above the roofline due to its higher corrosive resistance.
a) If an offset is necessary, it is important to support the vent pipe every 3 ft. to avoid excessive stress on the el-
bows and possible separation. Wall straps are available for this purpose.
b) Whenever possible, use 45º elbows instead of 90º elbows. The 45º elbow offers less restriction to the flow
of flue gases and intake air. If a 90º elbow is necessary there must be a minimum of one pipe section rise
between the 90º elbow and the vent cap. A maximum of three 90ºelbows are allowed per installation.
6. Slip the flashing over the pipe sections protruding through the roof. Secure the base of the flashing to the roof with
roofing nails and seal flashing to roof. Ensure the roofing material overlaps the top edge of the flashing. Verify you
have at least the minimum clearance to combustibles at the roofline.
7. Continue to add pipe sections until the pipe and the vent cap meet the minimum building code requirements, as out-
lined in No. 8 on the following PAGE.
a) For multi-story vertical installation, a ceiling fire stop is required at the second floor and any subsequent
floors. The opening should be framed to 9" x 9" inside dimensions as described in step No. 5.
b) Any occupied areas above the first floor, including closets and storage spaces, which the vertical vent passes
through, must be enclosed. The enclosure may be framed and sheet rocked with standard construction materials, however, be sure to maintain minimum allowable clearances between the outside of the vent pipe and
the combustible surfaces of the enclosure.
8. Height "*H" of top of vent cap can be determined as follows:
9. Complete installation with storm collar and vent cap.
"H" DIMENSION
ROOF PITCH FEET METERS
FLAT to 6/12 2 .6
7/12 to 9/12 2 .6
10/12 to 12/12 4 1.2
13/12 to 16/12 6 1.8
17/12 to 21/12 8 2.4
23
Page 25
DOOR REMOVAL AND REPLACEMENT
CAUTION: Do not operate the appliance with glass removed, cracked or broken. Replacement of the glass should be
done by a licensed or qualified service person. Glass latch tool #HA-57-00743 is supplied with the unit.:
To Unlatch Glass Frame Latches:
1. Insert Glass Latch Tool into hole in latch (two latches exist
at top of glass frame).
2. Pull Glass Latch Tool outward about 3/8”.
3. Rotate Glass Latch Tool 90 degrees.
4. Slowly Release Glass Latch Tool.
5. Remove Glass Latch Tool.
To Latch Glass Frame Latches, reverse steps 5 to 1,
above.
To Remove Glass Frame:
1. Rotate top edge of freed glass frame outward about 15
degrees.
2. Lift Glass Frame Up and Out.
To Install Glass Frame:
1. Align and insert tabs in side flanges of Glass Frame into Slots into the slot in the side bracket.
2. Rotate Glass Frame upward until vertical.
3. Latch Glass in place per instructions above.
1.) INSERT
2.) PULL
3.) ROTATE
4.) RELEASE
GLASS FRAME ASSY.
24
SPRING LATCH
INSERT
TAB
IN SLOT
DETAIL A
Page 26
GLASS FRAME ASSEMBLY REPAIR AND REPLACEMENT
DO NOT substitute other manufac-
turer's materials or components.
DO NOT operate unit with cracked,
broken or missing glass.
DO NOT abuse the glass door by
striking the glass, slamming the
WARNING
Use only authorized parts and
materials obtained from Johnson
Gas Appliance Company when
replacing defective or damaged
glass.
Do not operate this appliance
with the glass removed, cracked
or broken. Glass should be replaced by a licensed or qualified
person.
WARNING
TO REPLACE DAMAGED GLASS
1. Using an 1/8” drill bit, drill through 3 rivets on each side of glass frame.
2. Remove glass retainer brackets and the damaged glass and gasket material. Clean the inner surface of the glass
frame.
3. Assemble new gasket on glass edge starting with the bottom left corner. The adhesive on the gasket should
make contact with the glass surface. Use tracer lines in gasket to determine where the glass should sit on the
gasket surface.
4. Place glass and gasket assembly in glass frame. Carefully attach glass retainer brackets to sides of glass frame
using new 1/8” Aluminum rivets.
The glass frame assembly and its individual components are available through Johnson Gas Appliance Company. Contact your dealer for more detailed ordering information.
GASKET
GLASS
ROTATE GASKET UP
SO ADHESIVE MAKES
CONTACT WITH GLASS
SURFACE
TRACER LINES
IN G ASK ET
GLASS FRAME ASSEMBLY REPLACEMENT PARTS LIST
ITEM PART NUMBER DESCRIPTION
1
2 65-02-00103
3 65-06-00463
HA-30-00411
FRAME, WELDMENT, GLASS,
DXV35 DT 3
GASKET, TADPOLE,
3/8”BULB, 3/4” TAIL
GLASS, CERAMIC, DXV35
DT3
GASKET IN
FLAT FORM
GLASS SHALL SIT BETWEEN
TRACER LINES IN GASKET
ADHESIVE
25
Page 27
DXV-35 DT3 DEEP TIMBER LOG SET INSTALLATION INSTRUCTIONS
FOLLOW EACH STEP DEPICTED IN THE DIAGRAMS, BELOW, TO INSTALL THE LOG SET.
CAUTION: LOGS ARE FRAGILE, HANDLE LOG PIECES WITH CARE.
Carefully unpack 9-piece log set, bag of coals and bag of inswool. NOTE: Logs are very fragile, handle with
care. Break packaging foam if log pieces are trapped within foam. Do not pull on logs!
Coals must not block pilot or burner flames
! Placement of coals has a big effect on front burner flame appearance and "glow" of coals. More coals = less yellow flame and more glow. Fewer coals = more yellow flame
and less "glow".
Heat can be reduced by lowering flame height by turning the HI-LO knob. Blowers can also be turned down to
reduce heat output.
Do Not “over fire" by increasing Gas Input Rate above Rating Plate specifications.
Do Not turn down pilot flame length less than 1 inch long.
The following Check Off Lists must be completed prior to final operation of the Fireplace, or manufacturer's warranty and liabilities will be voided:
INSTALLATION CHECK OFF LIST
Co-axial vent rigid pipe, wall vent cap or roof vent cap must be installed by a Mendota
approved person in accordance with instructions. All joints must be secured, "twistlocked" and leak-proof. 1000ºF sealant use is recommended on the inner pipe joints of
DuraVent pipe sections.
Horizontal or vertical vent cap must be installed "right-side-up" and tightly sealed to
structure per instructions. Vent Caps must
Clearances to combustibles requirements must be strictly adhered to.
Proper exterior and interior clearances for vent systems and locations for wall vent
cap/roof vent cap must be maintained.
Carefully check for correct gas pressure, proper size gas lines and for gas leaks.
115 V electrical service and gas supply must be installed in accordance with instructions
and local and national codes.
LIGHTING CHECK OFF LIST
All items on "Installation Check Off List" (see above) must be completed.
Connect thermostat, if desired. Disconnect wires connected to Main On/Off switch and
connect thermostat lead wires to these two wires and run to thermostat location.
Check air shutter opening - 1/16" to 1/8" Nat. gas or 1/4" Min. LP gas.
Carefully follow all Lighting and Log Installation Instructions.
be Mendota approved.
Make certain that burner lights immediately and flame runs promptly around "curve" in
burner and lights entire burner. DO NOT proceed with operation unless burner cycles
"on/off" without delays.
Make certain that the flame is "stable" and does not "lift" off burner. If flame lifts off burner, turn unit off and check that all vent pipes are "twist locked" and leak proof, the vent
cap is "right side up". DO NOT proceed with operation if flame is "lifting off" burner.
Note: do not separate telescoping sections. They must
semblies.
Make certain glass door is in properly closed and "centered" in firebox opening.
be used as complete as-
37
Page 39
BEFORE YOU BEGIN
Read this entire manual before you use your new fireplace. Failure to follow the instructions may result in property damage, bodily injury, or even death.
Intermittent Pilot Light and Standing Pilot Light Features
This gas fireplace is equipped with an electronic ignition System that first lights a pilot light then uses the pilot light to ignite the main burners. The pilot light can be set in the “Standing Pilot” mode to allow the pilot light to remain on indefinitely by toggling the “Standing Pilot Switch” to the ON position. If the “Standing Pilot Switch” is toggled to the OFF position,
the pilot light will only light and remain ON while the main fireplace burners are operating.
IPI Mode:
This mode turns the pilot light “OFF” when the fireplace is not functioning and only lights the pilot light auto-
matically when a call for heat is made by the remote control.
Standing Pilot Mode
: If the “Standing Pilot Switch” is toggled to ON, the pilot light will ignite and remain ON as long
as the “Standing Pilot Light Switch” is in the ON position.
NOTE: Mendota Fireplaces recommends that the Standing Pilot Mode be used during the winter months when
external temperatures fall below 50
o
F. This will keep the fireplace chimney heated for proper updraft during burner igni-
tion and it will also eliminate excessive condensation of exhaust vapors on the door glass. Further, leaving the fireplace
in the Standing Pilot Mode will keep the fireplace body warm and eliminate cold drafts and heat loss to the cold air that is
trapped inside the firebox.
CONTROL PANEL FUNCTIONS IDENTIFICATION
PILOT LIGHT
SWITCH
MAIN ON/OFF
SWITCH
REAR BURNER
SWITCH
FLAME HEIGHT KNOB
38
Page 40
“FIRST TIME” LIGHTING INSTRUCTIONS
IMPORTANT: Be sure all items on "INSTALLATION CHECK OFF LIST" in the Installation Manual have been completed!
CAUTION: If the pilot goes out, be sure to wait a minimum of five minutes before attempting to relight the pilot.
1. Make certain that any manual gas supply shut-off valves located upstream of fireplace are open.
2. Make certain that 120VAC power is connected [and ON] to the electrical junction box on the left side of unit.
3. Insert Batteries in the Battery Holder if not already installed at the factory. Note the polarity of batteries and insert as
indicated on the battery compartment covers.
4. For the “First Time Lighting”, Remove the Glass Door. This is required to purge the gas line of air and to inspect the
pilot lighting spark.
5. Locate the “Standing Pilot ON/OFF Switch”. Toggle “Standing Pilot ON/OFF Switch” to “ON”. You will hear a series
of clicks and after a few seconds, you will hear sparking at the pilot spark electrode. Visually inspect the spark at the
pilot hood and verify that the spark jumps from the spark electrode to the pilot hood.
6. Allow adequate time for the air in the gas-line to purge. The control system will stop sparking after 30 seconds if the
pilot light does not light. After a 30 second delay the control system will start sparking again for 30 seconds more. If
the pilot light does not light after the third 30 second spark event, the system will enter “Lock-out” mode. To unlock
from “Lock-out” mode, toggle “Standing Pilot ON/OFF Switch to “OFF” and toggle Main ON/OFF Switch to “ON”, wait
30 seconds and toggle Main ON/OFF Switch to OFF. Toggle “Standing Pilot ON/OFF Switch to ON. Repeat this sequence until the pilot flame lights and the pilot is burning steadily.
LOCK OUT MODE
: If the pilot light does not light after the third 30 second spark event, the system will enter “Lockout” mode. To unlock from “Lock-out” mode, toggle “Standing Pilot ON/OFF Switch to “OFF” and toggle Main ON/OFF
Switch to “ON” (the sparking will start again); wait 30 seconds and toggle Main ON/OFF Switch to OFF. This will reset
the system.
7. Once the pilot flame is lit and well-established, close glass door. WARNING: NEVER IGNITE MAIN BURNERS
WITH GLASS DOOR REMOVED OR OPEN. Doing so will lead to damage to pilot flame sensor wire and spark
electrode wire leads.
8. Toggle Main Burners ON/OFF Switch to “ON”. All burners should ignite and run at “high-fire”. If rear burner does not
turn ON, toggle Rear Burner ON/OFF Switch to ON. After 15 seconds, Toggle Main Burners ON/OFF Switch to OFF.
Burner Flames will extinguish.
9. Perform gas inlet and outlet pressure tests and leak tests on field installed gas fittings and factory installed fittings in
the gas valve compartment, at this time. Note:
Burners must be ON to check outlet pressures and to leak test gas
train fittings upstream of main gas valve.
Backup Batteries: The life span of the backup batteries depends on the quality of the batteries used and how long the
batteries have been installed in the wall receiver. These batteries are only utilized during power outages. Replace these
batteries every heating season even if you have not experienced any power outages. Batteries drain slowly even when
not in use. This is a normal characteristic of all batteries. To prevent the batteries from bleeding while not in use, you may
choose to remove the backup batteries and install them only when they are needed.
OPERATING DURING POWER OUTAGES
This electronic ignition system utilizes the supplied 110VAC power when it is available for all functions of this system. If
the AC power is interrupted during a power outage, this system utilizes the batteries (installed in the Wall Receiver) as
back-up batteries. During the power outage, the appliance’s burners will function. In addition, Flame Height adjustment
and Secondary Burner ON/OFF functions will be available. The Fan and Accent Light, which are wholly dependent on
110VAC power, will not function.
This appliance is designed and tested to be operated during power outages. The overall efficiency of this appliance will be
reduced by approximately 5% when the blower function is disabled during the power outage period.
39
Page 41
THERMOSTAT OR REMOTE CONTROL OPERATION
The Fireplace may be connected to a wall thermostat, a remote control or a wall switch. The thermostat should be placed
in the same room as the fireplace, approx. 4-5 ft. off the floor (out of reach of children). DO NOT
place thermostat within
8 feet of this fireplace or on an outside wall.
CAUTION:
In standing pilot mode, burner should light after turning thermostat "on". If burner does not come on imme-
diately, turn the thermostat off and wait 60 seconds before turning on again. If burner does not come on immediately after
second try recheck complete installation of logs, pilot, vent system, etc. Do not
operate fireplace if burner does not light
immediately. Call service technician.
NEVER TURN BURNER ON & OFF "QUICKLY" - ALWAYS WAIT 60 SECONDS BETWEEN ON AND OFF!
NOTE: The maximum length of thermostat wire allowed is 25 feet. Use of longer thermostat wires may cause malfunction
of the thermostatic function.
CAUTION: NO EXTERNAL POWER SUPPLY CAN OR SHOULD BE USED.
Use two-wire, copper lead wire per chart below and install as follows:
NOTE: Thermostat Must Be Millivolt Rated
RECOMMENDED MAXIMUM
LEAD LENGTH (TWO-WIRE)
WHEN USING WALL THERMOSTAT
WIRE SIZE MAX. LENGTH
16 GA. 25 FT.
18 GA. 25 FT.
20 GA. 25 FT.
22 GA. 18 FT.
Figure 8: Thermostat Wiring
NOTE: Thermostat must be millivolt rated (dry contact type only).
HOW TO CONNECT A THERMOSTAT OR WALL SWITCH TO THIS FIREPLACE
Remove Courtesy Panel and disconnect wires from back of Main Burners ON/Off Switch. Connect Thermostat Leads to
the two wires you removed from the Main Burners ON/OFF Switch and run to the thermostat location. Connect thermostat
to the wire leads. Test thermostat in Standing Pilot Mode first.
VALVE COIL 2
[ORANGE]
VALVE COIL 1
[DARK GREEN]
PILOT LIGHT
ON/OFF
SWITCH
[DARK BLUE]
PILOT SWITCH
GROUND
[YELLOW+GREEN]
MAIN
BURNERS
ON/OFF
SWITCH
CONNECT WALL THERM OS TAT TO
THESE TWO CONNECTORS.
[REMOVE MAIN BURNERS ON/OFF
SWITCH FIRST]
ON/OFF [DARK
ON/OFF [WHITE]
BLUE]
BLACK
RED
BLACK
RED
DC
TRANSFORMER
BATTERY
PACK
IGNIT IO N
MODULE
40
Page 42
BLOWER OPERATION AND WIRING
WARNING: The Electrical Junction box within this appliance must be connected to a grounded LIVE power circuit. No
switches, Light Dimmers or Fan Speed Control Devices are allowed within the same electric circuit as this appliance.
Connect only to a LIVE electrical power supply that is not controlled by any other switching device.
Dual blowers are provided as standard equipment with this DXV35 DT3 Fireplace. The dual blowers have an air output
rating of 210 CFM (in free air). This Fireplace is designed to operate with the blowers turned ON when the appliance
is running and hot. The blowers increase the overall efficiency of this fireplace and aid in distributing and circulating
heat to the room this Insert is installed in.
BLOWER BREAK-IN PERIOD: The integrated blowers in this Insert may exhibit some bearing noise and electrical
static noise during the first few hours of operation. This is normal during the break-in period. It is recommended that
following the Paint Curing Cycle, the blowers be run at their maximum speed for two 3-hour periods. The blowers in a
few units may take longer to break-in and may require additional operation time before all extraneous noise is eliminated. Please allow adequate operational time (a minimum of 2 weeks) for the blowers to break-in before you contact
your dealer for service.
WARNING: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation after servicing.
BLOWER OPERATION
This Fireplace is designed so the blower operates at all times the fireplace is operating. The blower output can be regulated with the rheostat. NOTE: There will be a time delay in blower operation during "heat-up" (approx. 15 minutes)
and extended blower operation during "cool-down" of unit. (Approx. ½ hour). NOTE: Power supply to blower must be
continuous. DO NOT use a switch or variable speed control in power supplied to fireplace.
OPERATION DURING POWER OUTAGES
The fireplace is designed to operate during power outages for 1-1/2 continuous hours, Maximum. The blower will not
operate, but natural convection can be improved by removing the upper grill and opening the screen doors (depending
on the type of optional front installed). After 1-1/2 continuous hours of operation, during the power outage, turn off the
burners for 1 hour and allow the fireplace to cool down. Consecutive 1-1/2 hour burn and 1 hour cool down cycles are
allowed.
41
Page 43
TROUBLE SHOOTING MENDOTA GAS DXV FIREPLACE
SYMPTOM PROBABLE CAUSES CORRECTIVE ACTION
1. Thin black coating
(soot) forms on viewing
glass.
2. Humming or whistling
coming from Fireplace.
3. A change in flame appearance or burner operation.
A. Incorrect gas pressure
B. Not enough combustion
air
A. Normal operating noise.
A. A change in gas pres-
sure.
B. Carbon, dirt or lint
Have gas supplier check for correct gas pressure (7" W.C. Nat. Gas; 11"
W.C. LP Gas).
If sooting continues open air shutter on burner (see "Gas Flame Adjustment" below).
If sooting still continues, shut off unit and call Mendota service person.
NOTE: To clean glass - remove glass and wipe glass with cloth or paper
towel.
Some noise is normal. It is caused by the gas supply flowing through the
gas orifice. It is expected from any gas fireplace. Turning the Hi/Lo Knob
on the control can reduce the noise. Turning down the flame will reduce
the heat output of the unit.
Have your gas supplier check for correct gas 7" W.C. Nat. Gas; 11" W.C.
LP Gas). If flame still needs adjustment see "Flame Adjustment" below.
Clean out carbon, spider webs, lint, etc. from shutter area.
Logs and burner.
NEVER BLOCK AIR INTAKE OR OUTLET VENTS.
FLAME ADJUSTMENT
Be sure burner and logs are properly installed. After logs have been properly installed and operated for
one to one and a half hours, small additional adjustments to the air shutter may be necessary for final
flame appearance. These small shutter adjustments can be made by the following procedure:
NOTE: Very small changes in shutter settings make major
changes in flame appearance.
1. One Air Shutter Control is located behind lower hinged grill on the right side. This controls the rear burner shutter. This shutter control controls the rear burner flames. The front burner shutter is of the rotary-type. The front
burner shutter is factory adjusted for Natural Gas at 1/8” open. For LPG, open to a minimum ¼”.
2. Light pilot; install logs and glass, and burn unit for 30 minutes.
3. If flame is too "blue" push Air Shutter Control Knob inward until flame turns yellow.
4. If flame is too "orange" or is causing sooting open shutter until flame begins to turn blue. NOTE: If sooting
does not stop, turn off fireplace & call Mendota Service Person.
5. IMPORTANT: Try each new shutter setting approx. 1/2 hour before making additional changes.
NOTE: Changes in front burner flame can be made by re-arranging the coals and rock wool. Densely packed
coals will yield more glow and blue flames. Loosely packed coals will yield less glow and yellow flames.
CAUTION: Any changes in pilot flame length must be made by qualified person only.
42
Page 44
CUSTOMER INFORMATION AND TROUBLE-SHOOTING
MAXIMUM ALLOWABLE SURFACE TEMPERATURE
Mendota Fireplaces comply with UL Standards for maximum surface temperatures on exposed combustible surfaces adjacent to the unit. The Maximum allowable surface temperature is 117° F. over ambient (room) temperature. Thus, if a
room is 70° – 80° the exposed combustible surfaces immediately surrounding the Fireplace can have a surface temperature as high as 187° F. – 197° F. (Too hot to touch). The continuous blower operation automatically keeps temperatures
within these safety limits. During power outages you may turn on the burners for maximum 1-1/2 hours at a time with a 1
hour cooling period in between the burn cycles. Do not exceed the 1-1/2 hour burn time during power outages.
OVER FIRING OF BURNER
NEVER "over fire" units by adjusting gas pressure or drilling out the orifice to increase BTUH above nameplate specifications. Over firing can cause permanent damage to firebox and deterioration of parts and void warranty.
MAINTAINING CORRECT PILOT-FLAME -- PILOT OUTAGE & RELIGHTING
If pilot flame goes out, always wait 5 minutes before relighting.
CLEANING VIEWING GLASS
The viewing glass should be cleaned periodically. Exterior glass surface may be cleaned with cleaner as desired. The
Interior glass surface should be cleaned using only soap and water or KEL KEM “Polish Plus” or comparable product.
CAUTION: Do not
use oven cleaner to clean glass. Never touch glass or attempt to clean when glass is hot.
NOTE: Additives that are put in gas (both natural and propane) to make it smell can be harmful to glass and can leave a
white film deposit on the glass. This deposit can be removed with cleaners such as KEL KEM “Polish Plus” (part # 65-06-
00455) or comparable product (contact your dealer).
In some cases (especially when burning propane) additives can cause “crazing” or etching on the glass. This is not an
uncommon occurrence and it is not covered under the warranty. The solution may be to change propane suppliers.
SOOTING
Sooting
is caused by improper installation or operation. However, some small areas of soot deposits on log surfaces are
deemed acceptable. Open the burner air shutters if you observe sooting. If you observe large soot areas (larger than
1”x2”) on log surfaces or signs of sooting on the door glass (usually a thin black film on the Fireplace viewing glass or on
the outside of the home around the vent cap), open both burner air shutters. If sooting continues, the unit must be immediately turned off and the local Mendota dealer promptly informed. Mendota dealers will correct "sooting" problems, but
Mendota and their dealers are not
responsible for damage caused by excessive sooting that has not been immediately
brought to their attention.
OPERATION DURING POWER OUTAGES
The fireplace is designed to operate during power outages using the backup batteries for 1-1/2 continuous hours, Maximum. The blower will not operate, but natural convection can be improved by removing the upper grill and opening the
screen doors (depending on the type of optional front installed). After 1-1/2 continuous hours of operation, during the
power outage, turn off the burners for 1 hour and allow the fireplace to cool down. Consecutive 1-1/2 hour burn and 1
hour cool down cycles are allowed.
Hot air convection may be improved by removing upper grill of the Millennia and Deerfield Fronts, opening the doors on
the Andover and Prairie Fronts and opening the screen on the Wellington Front.
43
Page 45
MAINTENANCE
1. ANNUAL MAINTENANCE OF MENDOTA UNITS IS REQUIRED.
each year by a Mendota approved service person. NOTE: Any adjustments to burner, pilot or logs must
by a qualified Mendota service person.
A. Replace backup batteries at least 2 times annually. Replace them when the Day Light Savings Time
changes.
B. Clean all lint and dust build-up around the control. Inspect the condition of any wiring under the burner for
melting or damage.
C. Remove logs & coals and clean away any foreign matter (lint, Carbon, etc.) on the burner and logs. Be sure
the burner ports are "open". Clean the pilot and under side of the logs for any Carbon deposits. NOTE: Logs
should be visually checked for Carbon "build-up". If carbon deposits are visible on logs, unit should be turned
off and Mendota service person contacted. Be sure logs are re-installed per instructions.
D. Check condition of glass door gasket, gasket must seal tightly over firebox, replace if necessary.
E. Periodically check to verify that the vent system and vent cap are open and free of blockage.
F. Before re-installing glass, have qualified service person check the operation of the pilot
G. The viewing glass should be cleaned periodically. Exterior glass surface may be cleaned with cleaner as desired.
To clean Interior glass surface, use Kel Kem
“polish plus" (part # 65-06-00455) or comparable product. Do not use
oven cleaner or abrasive cleaners to clean glass. Do not clean when glass is hot
H. Periodic visual check of pilot flames is required. Pilot Flame must overlap Flame Sensor and burner ignition ports at
all times.
I. Periodic visual check of main burner’s rear and front flames is required.
The following procedures must be performed
be done
.
HOOD
BURNER FLAMES GENERAL HEIGHTS REFERENCE DIAGRAM
REAR
FLAME
BURNER
PILOT LIGHT FLAMES
MUST OVERLAP
BURNER PORTS.
SENSOR
SPARK
ROD
44
FRONT
BURNER
Page 46
WIRING SCHEMATICS
Note: The DXV35 DT3 ignition system utilizes Transformed DC power for normal ignition functions. In the event of a power outage, the Battery Pack power is utilized.
IGNITION SYSTEM WIRING SCHEMATIC
MAIN
BURNERS
ON/OFF
SWITCH
CONNECT WALL THERM OS TAT TO
THESE TWO CONNECTORS.
[REMOVE MAIN BURNERS ON/OFF
SWITCH FIRST]
DC
TRANSFORMER
VALVE COIL 2
[ORANGE]
VALVE COIL 1
[DARK GREEN]
PILOT LIGHT
ON/OFF
SWITCH
[DARK BLUE]
PILOT SWITCH
GROUND
[YELLOW+GREEN]
ON/OFF [DARK
ON/OFF [WHITE]
BLUE]
BLACK
RED
BLOWER SYSTEM WIRING SCHEMATIC
IGNIT IO N
MODULE
BLACK
RED
BATTERY
PACK
45
Page 47
NATURAL TO LP GAS CONVERSION INSTRUCTIONS
Kit # HA-30-00501 Mendota Model DXV35 DT3
This conversion kit shall be installed by a qualified service agency
in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If
the information in these instructions is not followed exactly, a fire,
MANUAL
LP Pressure
Regulator
[10.0-6.4"WC]
# 0.907.011
explosion or production of carbon monoxide may result causing
property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The
installation is not proper and complete until the operation of the
converted appliance is checked as specified in the owner instructions supplied with the kit.
Caution: The electrical supply to the fireplace must be turned off
prior to performing the conversion. The gas supply must be shut
off prior to disconnecting the electrical power.
ORIFICE SIZES REQUIREMENT:
A Natural Gas to LPG conversion kit #HA-30-00501 is included
with this fireplace insert.
Burner Orifice
#65-14-00364
[3/64"DRILL]
3
6
4
3
6
4
LP Pilot Orific e
[#05-04-00052]
[#977.168]
LP Conversion Kit # HA-30-00501 contains the following parts: One Motorized LP Pressure Regulator #907.012, One LP
Pilot Orifice Thimble #977.168, and two Cap Orifices #65-14-00364(drill #3/64”) and an L-shaped Torx wrench.
RECOMMENDED PROCEDURE TO CONVERT THIS FIREPLACE TO BURN LPG
This Fireplace Insert arrives from the factory ready to burn Natural Gas. If you intend to burn LPG, it is highly recommended that you convert this fireplace and its Pressure Regulator, Pilot Orifice Thimble and Burner Orifices prior to placing this fireplace in its fireplace cavity.
See diagrams, on this page, and follow these instructions to prepare this fireplace for conversion to LPG.
1. Using a ¼” Hex Driver, remove 2 screws that secure the Rear and Front burners to the Burner Airbox.
2. Lift Up and remove Front Burner.
3. Loosen Front Burner Air Shutter Screw and rotate air shutter open ¼” minimum. Set burner aside.
4. Slide Rear Burner to the right about 2” and lift up and remove from Firebox.
REAR BURNER
BURNERS MO UN TING
SCRE W S
46
FRO NT BU RN ER
Page 48
5. Using a ½” deep well socket wrench, remove Front and Rear Orifices.
6. Thread a new 3/64” drilled orifice to both Front and Rear Orifice mounting brass fittings. Tighten down orifices.
7. Locate Pilot Light Hood.
8. Install pilot orifice thimble ##977.168 see Figure below for location. To remove Pilot Hood, use a screw driver to pry
open the Wire Clip that is located at the base of the Pilot Hood. Pull Upward and remove pilot hood. Use an Alan
wrench to remove NG Pilot Orifice. (Pilot orifice thimble is located inside pilot hood base).
9. Install LP Pilot Orifice. Tighten down using an Alan wrench. Replace Wire Clip in its original position.
10.
Push Pilot Hood down into base until it snaps in place.
FRONT
ORIFICE
DETAIL D
DETAIL C
REAR
ORIFICE
REAR
BURNER
Pull Pilot Hood UP
and lift UP off the base.
Use an Alan Wrench
To loosen and remove
NG P ilo t Orifice. I n st all
LP P ilot Orifice, Tight en
Down.
WIRE
CLIP.
PILOT LIGHT
HOOD
FRONT
BURNER
47
Page 49
11. Before reinstalling burners, loosen the screw that secures the rotary air shutter on the Front Burner. Rotate the air
shutter open to ¼” minimum.
12. Install both rear and front burners
in their original locations and positions and secure down using
screws you removed earlier.
13. Make certain front burner is running parallel to front face of unit positioned properly so that the pilot light hood pointing to the left is pointed properly
towards the burner’s flame propagation ports.
14. Make certain Rear Burner is positioned properly so that the pilot light hood pointing to the left is pointed properly towards the burner’s flame propagation holes.
REAR
BURNER
ROTATE SHUTTER O PEN
LOOSEN SCREW
-1/ 4 " MIN IMU M-
FRON T BURNER SHUTTER ADJUSTM ENT
PILOT LIGHT FLAMES
MUST OVERLAP
BURNER PORTS.
48
FRONT
BURNER
Page 50
INSTALLING THE LP PRESSURE REGULATOR
WARNING: READ AND UNDERSTAND ALL INSTRUCTIONS PACKAGED WITH LP PRESSURE REGULATOR BODY
BEFORE YOU ATTEMPT THE CONVERSION. FAILURE TO FOLLOW ALL INSTRUCTIONS WILL RESULT IN A LEAK
OR OVERFIRING OF THE APPLIANCE AND CAN LEAD TO AN EXPLOSION OR A FIRE HAZARD.
1. Remove the Courtesy Access Panel mounted behind the lower grill and lay down gently without disconnecting
any wires of internal components. WARNING: DO NOT FORCE. EXCESSIVE FORCE MAY DAMAGE
INTERNAL WIRING COMPONENTS!
2. Pull out and remove Extension Knob on NG Pressure Regulator and set aside.
3. Follow Instructions given below directly from SIT Controls. Replace Extension Knob as the final step.
49
Page 51
LP GAS PRESSURE REQUIREMENTS
Inlet and manifold gas pressure checking taps are located on gas valve. These ports are only accessible from the outer
left side of the fireplace. A qualified installer shall take pressure measurements at these ports to verify and set the correct
gas pressures during the LP Kit installation and before fascia materials are installed over the front of this fireplace. Manifold pressure must
be taken at the “MANIFOLD PRESSURE" tap and inlet pressure at the "INLET PRESSURE" tap with
the burner operating by a qualified installer.
DESIRED
INLET
PRESSURE
MINIMUM
INLET
PRESSURE
MAXIMUM
INLET
PRESSURE
MANIFOLD
OUTLET
PRESSURE
AIR SHUTTER
POSITION
L.P. GAS 11.0" W.C.
(2.75 kPa)
REGULATE THE FLAME HEIGHT TO "HIGH" POSITION. OUTLET GAS PRESSURES MAY VARY PLUS OR MINUS 5%.
11" W.C.
(2.75 kPa)
13.0" W.C.
(3.24 kPa)
10.0" W.C.
(2.5 kPa)
1/4" OPEN MIN.
(5 mm)
LPG PROPER INPUT RATES
With the proper orifices installed, as specified above,
this fireplace utilizing LP Gas will have a maximum
input rate of 31,000 Btu/Hr.
LEAK TESTING REQUIREMENTS
Prior to completing the conversion process, check for
gas leaks with soap and water solution at all plumbing
joints prior to placing this appliance into operation. It
is recommended that all gas-plumbing joints, factory
installed and field installed are checked for leaks.
PILOT FLAME AND MAIN BURNER RELATIONSHIP VERIFICATION
INLET TAP
OUTLET TAP
Prior to completing the conversion process, the qualified service technician must, light the pilot light and verify the relationship between the pilot light flames and the main burners. The pilot light flames
directed towards the propagation ports on the rear and front burner must overlap
Figure 9: Pressure Test Port
the propagation ports on the burners. The pilot light flames must be a minimum of
¾” long and must overlap the propagation ports on both the rear and front burners as shown in the diagram, below. Verify
that the burner tubes ignite quickly and the burner flames propagate smoothly along the entire length of the burners.
PILOT FLAME LENGTH ADJUSTMENT
If the pilot light flame length is too short and the system does not maintain a standing pilot, a qualified installer may increase the length of the pilot light flames
REAR
BURNER
1" MIN.
PILOT LIGHT FLAM E S
MUST OVERLAP
BURNER PORTS.
to meet the two requirements: Minimum pilot light
length to maintain a standing pilot light and the pilot
light flames must be long enough to overlap the front
and rear burner ports, 1 inch long minimum.
50
FRONT
BURNER
Page 52
CHECKING FOR NORMAL BURNER (S) IGNITION CHARACTERISTICS
Once the conversion to LPG and all the above steps have been completed, light the main burners.
Turn Gas Dial counterclockwise to "ON" then set Thermostat or push Main Burner ON/OFF switch to turn on burners.
Main burner should now light IMMEDIATELY and flame should not "lift" off burner. If there is any delay in ignition or if
flame is "lifting off" burner, turn off burner and carefully check for proper installation of logs/coals, vent system and proper
pilot flame impingement on burner and thermopile. Logs or coals must not block pilot flame or main burner flame. Vent
system must be leak proof.
ATTACHING LPG CONVERSION LABELS AND HIGH ALTITUDE DERATION LABEL
Two printed informational labels are included with the LPG Conversion Kit. Attach these two labels to the rear surface of
this insert adjacent to the Serial Number Plate. If you are derating this appliance at a high altitude, also attach the High
Altitude Deration Label, supplied in the Owner’s Manual Packet, to this same surface adjacent to other labels.
Prior to attaching the labels, fill in all the information that is requested in these labels.
DO NOT PROCEED WITH OPERATION OF THIS FIREPLACE
UNLESS BURNER "CYCLES" ON/OFF WITHOUT DELAYS!
WARNING
For installations from 610-1370 meters (2000-4500 ft.) the orifice sizes (DMS) for natural and propane gas are
_#45R/#49F_ and _#55”R/#3/64”F_, respectively. See data plate for additional information. For high altitude
installations consult the local gas distributor or the authority having jurisdiction for proper rating methods. If the
installer must convert the unit to adjust for varying altitudes, the information sticker must be filled out by the
installer and adhered to the appliance at the time of conversion."
«Cet appareil est equipé pour des altitudes compries entre 0 et 2000 pieds (0-610 m) seulement»
This appliance has been converted for use at an altitude of ______________
Orifice size _______________ Manifold Pressure ________________
Input (Btu/h) _______________ Fuel Type _______________________
Date of conversion _________ Converted by _____________________
«Cet appreeil a été converti au ____
Injecteur ________
Pression à la tubulure d'alimentation _____________
Déoit calorifique ______________
GAS LEAK TEST REQUIREMENT: It is the responsibility of the installer/service person to assure
that each and every gas connection and supply tubing that are a part of this fireplace are leak proof.
The qualified/ certified individual connecting the gas supply line, performing pressure tests or performing any service to this fireplace is required to perform a THOROUGH LEAK TEST on ALL gas
fittings that are a part of this appliance or the gas supply line connection using soap-water solution or
a calibrated combustible gas detector. Failure to perform this leak test may lead to a house fire
and/or an explosion. Mendota is not responsible for any damages due to an Installer’s failure to conduct a leak test and verify that all connections and supply lines are leak proof.
WARNING: Do not operate appliances with glass front removed, cracked, or broken. Replacement of glass should be
done a licensed or qualified service person.
Note: Consult the local or national installation code(s) to assure that adequate combustion and ventilation air is available.
WARNING: It is of the utmost importance that the correct burner orifices be installed for both the rear and front burners.
51
Page 53
REPLACEMENT PARTS
MENDOTA GAS DXV-35 DT3 FIREPLACE
PART NO DESCRIPTION PART NO DESCRIPTION
65-02-00103 TADPOLE GLASS GASKET (106”) 05-04-00050 PILOT ASS'Y. NAT.
65-06-00463 GLASS – FLAT 05-04-00052 LP PILOT ORIFICE
HA-30-00415 DOOR FRAME ASSEMBLY – FLAT HA-30-00501 LP KIT
35-01-00600DEEP TIMBER III LOG SET 65-06-00149 PIEZO IGNITER
35-01-00240 COALS 12 OZ BAG 65-14-00044 REAR ORIFICE (NAT. GAS) # 44
35-01-00239 GLOWING INSWOO L 65-14-00049 FRONT ORIFICE (NAT. GAS) # 49
35-01-00601 FIREBRICK KIT 65-14-00364 REAR/FRONT ORIFICE (LP GAS) 3/64”
70-01-00130 REAR BURNER TUBE WELDMENT 15-02-00064 R H BLOWER WIT H MOTOR
HA-82-00408 FRONT BURNER TUBE WELDMENT 15-02-00065 L H BLOWER WITH MOTOR
HA-30-00405 VALVE ASEMBLY, DXV35 DT3 05-01-00157 SNAP-DISC (FAN TEMP SENSOR)
10-03-00068 REAR FLAME WIRING W/ SWITCH 10-01-00003 RHEOSTAT/BLOWER SPEED CONTROL
05-02-00351 REAR FLAME ON/OFF VALVE 65-06-00125 BLACK PAINT - 12 OZ. SPRAY CAN
05-02-00364 SIT VALVE NAT. GAS 65-06-00455 KEL-KEM GLASS CLEANER/POLISH
05-02-00284 HI-LO EXTENSION KNOB
WARNING: Use only authorized parts and materials obtained from Johnson Gas Appliance when replacing defective or
damaged glass.
DO NOT substitute other manufacturer's materials or components.
DO NOT operate unit with cracked, broken or missing glass.
WARNING: DO NOT OPERATE THIS APPLIANCE WITH THE GLASS REMOVED, CRACKED OR BROKEN. REPLACEMNET OF GLASS SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON.
52
Page 54
MENDOTA DESIGNER FRONTS INSTALLATION INFORMATION
The following Designer Fronts are available for the DXV-35 Fireplace:
1. Andover, Bentley Arched Door Kit or Prairie Rectangular Door kit with Fire screen with optional Overlays as listed
below:
a. Black Overlay
b. Pewter Overlay
c. Antique Copper Overlay
d. 24K Gold
2. Wellington Fire screen Front
3. Black or 24K Gold Victoria Filigree
4. Black or 24K Gold Tuscany Filigree
5. Millennia Flat Grills in four optional color schemes as listed below:
a. Black Millennia Flat Grills
b. Full Brass Millennia Flat Grills
c. Classic Black and Brass Millennia Flat Grills
d. Classic Black and Bright Silver Millennia Flat Grills
Information specific to the installation of the Andover, Bentley and Prairie Fronts
The Andover Door and Prairie Door Fronts are designed to be “Full-Face” trim kits. These two Fronts cover an area
equivalent to that shown in the diagram below. Any material that protrudes into this area on the sides, top or bottom
edges can only be flush with the front surface of the fireplace faceplate.
If planning to install either the Andover Door or the Prairie Door Front, DO NOT COVER THE FACEPLATE OF THE FIREPLACE WITH ANY MATERIALS. Furthermore, any drywall or wall covering material that is adjacent to the sides,
top or bottom of the Fireplace’s faceplate may not protrude out past the front surface of the Fireplace Faceplate’s front
surface.
The Andover, Bentley and Prairie Doors Mounting Faceplate (required for installation of the Andover,
Bentley and prairie Doors) may be covered over with noncombustible facing materials. See Figure 11,
below.
To install Tile, Marble, Slate, Stone, Rocks or
other noncombustible facings to enhance the
arch shape of the Andover Doors or the Rectangular shape of the Prairie Doors, do so
only after the Andover or Prairie Door Kits
have been installed on the DXV-35 Fireplace.
WARNING: COMBUSTIBLE
MATERIALS MUST NOT COVER
THE FRONT SURFACE OF THE
FIREPLACE’S FACEPLATE.
Figure 10
53
Page 55
Information specific to the installation of Millennia Flat Grills, Victoria Filigrees and Tuscany Filigrees
The Millennia Flat Grills, Victoria Filigree and Tuscany
Filigree are designed to be “inside-fit” trim kits. All of
these trim kits fit within the inner perimeter of the Fireplace’s Faceplate and remain flush within the Faceplate’s
front surface, see Figure below. This fitting method allows flexibility in covering the black visible surface of the
Faceplate with non-combustible materials such as Tile,
Marble, Slate, Stone and Brick; as long as enough room
is allowed for the removal of these Mendota Designer
Fronts and the glass door for servicing,
WARNING: COMBUSTIBLE MATERIALS
MUST NOT COVER THE FRONT SURFACE
OF THE FIREPLACE’S FACEPLATE.
Figure 11
Information specific to the installation of the WELLINGTON FIRESCREEN FRONT:
The Wellington Fire screen Front is designed to be
“inside-fit” trim. The top and sides of these trim kits
fit within the inner perimeter of the Fireplace’s Faceplate. The bottom member of this trim, however, overlaps the bottom 2” black boarder of the fireplace front
faceplate. Therefore, DO NOT COVER THE
BOTTOM 2” BOARDER OF THE FIREPLACE
FACEPLATE WHEN INSTALLING THE
WELLINGTON FIRESCREEN TRIM. The sides and
top edges of the black visible surface of the Faceplate may be covered with non-combustible materials
such as Tile, Marble, Slate, Stone and Brick; as long
as enough room is allowed for the removal of this Mendota Designer Fronts
and the glass door for servicing,
Hearth Protection Pad Installation Information when planning to install the Wellington
Front
If planning to install the Wellington Front, the hearth protection pad installed in front of the DXV-35 Fireplace must be designed, built and installed so that the hearth protection pad’s top surface is flush with the
bottom-most surface of the DXV35 Fireplace. See FIGURE 21.
Figure 13
Figure 12
WITH NON-COMBUSTIBLE MATERIALS WHEN INSTALLING
THE WELLINGTON FIRESCREEN FRONT.
ONLY THE CROSS HATCHED AREA MAY BE COVERED
DO NOT COVER THIS AREA OF THE FACEPLATE WHEN
INSTALLING THE WELLINGTON FIRESCREEN FRONT
HEARTH PAD
SURFACE
HEARTH PAD SURFACE MUST BE
FLUSH WITH FIREPLACE BOTTOM
IF INSTALLING THE
WELLINGTON!!
54
Page 56
RATING LABEL REPRESENTATION
DXV35 DT3
55
Page 57
MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM
As a part of Mendota's on-going program of customer satisfaction, this Form verifies proper installation and operation. It is important as a reference for future service. It insures long life and trouble-free operation of Mendota fireplaces & stoves and qualifies the owner for Mendota's lifetime limited warranty. Owner should sign Form when completed and mail a copy along with
Warranty Registration to Mendota. OPTIONALLY, PLEASE REGISTER AT OUR WEBSITE AT:
MODEL #: DXV-35 ___________________ SERIAL #: _______________________________ DATE
INSTALLED: __________
Mendota direct vent fireplaces are sophisticated, hi-tech gas appliances. All installation and operating instructions must
be carefully followed. The DXV fireplace must
be installed and serviced by a qualified Mendota approved service person.
REF: MENDOTA DXV35 DT3 INSTALLATION MANUAL
APPROVED VENT PIPES AND VENT CAP INSTALLED - Per Manual.
Vent pipes must be fully twist-locked and leak proof.
Check minimum and maximum vertical / horizontal and vent runs.
CHECK FOR PROPER CLEARANCES TO COMBUSTIBLES & VENT LOCATIONS - Per Manual
INSTALL PROPER SIZE GAS LINES - CHECK FOR GAS LEAKS - Per Manual
CHECK FOR CORRECT GAS PRESSURE AT MANIFOLD - Per Manual
a. 3.5 Inches Water Column Maximum - Nat. Gas (1/8” WC variation is allowed)
b. 10.0 Inches Water Column Maximum - L.P. Gas (1/8” WC variation is allowed)
CYCLE BURNERS ON/OFF FOR PROMPT IGNITION - Per "LIGHTING INSTRUCTIONS"
Burner must light IMMEDIATELY - Flame must travel promptly around "curve" & light burner
.
INSTALL LOGS AND ADJUST FLAME - Per Manual
Proper pilot flame impingement on flame sensor & burner - Air shutter opening: 1/16" - 1/8" Nat. Gas - 1/4" LP
Check that flame is "stable" and is not "lifting" off burner
WARRANTY REGISTRATION
Your Name _______________________________________________________________
Address __________________________________________________________________
City ____________________________________ State _____ Zip ____________________
Dealer (Place of Purchase) ___________________________________________________
City ____________________________________ State _____ Zip ____________________
Date of Purchase ___________________ Serial Number ___________________________
Purchaser's Signature _______________________________________________________
MENDOTA DXV-35DT3 DIRECT VENT FIREPLACE
CUT OUT PAGE AND MAIL TO: JOHNSON GAS APPLIANCE CO., 520 E AVE. N.W., CEDAR RAPIDS, IOWA 52405
PLEASE REGISTER AT OUR WEBSITE AT: WWW.JOHNSONGAS .COM/MENDOTA-REGISTRATION.ASP
MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY
MENDOTA DXV-35 DT3 DIRECT VENT FIREPLACE
Mendota Division of Johnson Gas Appliance Company, 520 E Avenue N.W. Cedar Rapids, Iowa 52405, extends this Extended Lifetime Protection and Limited Warranty to the original purchaser of a Mendota DXV Fireplace, Serial Number, which is limited and used under normal
home conditions.
STANDARD WARRANTY:
JOHNSON GAS APPLIANCE CO., MENDOTA DIVISION, WARRANTS THAT YOUR NEW MENDOTA FIREPLACE IS FREE FROM
MANUFACTURING AND MATERIAL DEFECTS FOR A PERIOD OF ONE YEAR FROM THE DATE OF INSTALLATION, SUBJECT TO THE
FOLLOWING CONDITIONS AND LIMITATIONS:
EXTENDED LIFETIME WARRANTY:
THE HEAT EXCHANGER, BURNER TUBE COMBUSTION CHAMBER AND OUTER SHELL OF THIS MENDOTA FIREPLACE ARE
WARRANTED FOR THE LIFETIME OF THE ORIGINAL OWNER, SUBJECT TO PROOF OF PURCHASE AND THE FOLLOWING
CONDITIONS AND LIMITATIONS:
1.This new Mendota Fireplace must be installed & serviced by a competent, authorized service contractor. It must be installed and operat-
ed at all times in accordance with the installation and operating instructions furnished with the Fireplace. All adjustments to logs. Coals or
burner must be made by an authorized Mendota person. Any alteration, willful abuse, accident or misuse of the product shall nullify this
warranty. This warranty does not cover glass or log breakage.
2.This limited warranty does not cover the cost of service calls, the cost of labor to remove or install parts covered by this limited warranty,
freight or other transportation expenses, which may be incurred in connection with obtaining performances under this limited warranty.
The remedy for damages as the result of any defects in this product which have been warranted herein is limited to replacement parts
and does not include any incidental, indirect or consequential damages or expenses sustained in connection with the product, including
damages to property, except as provided by law.
3.This warranty is non-transferable and is made to the original retail purchaser, provided the purchase was made through an Authorized
Mendota Dealer.
4.Mendota is not responsible for any damage to or malfunction of the Fireplace unless caused by a defect in material or workmanship
from normal home use. Damage caused by abuse, improper installation, improper servicing, and installation by unqualified personnel
or breech of conditions of this limited warranty will excuse Mendota from performance of any part of this limited warranty. Mendota has
the right to investigate and inspect the exact, original Fireplace and entire installation (without any alterations or tampering) in the event
a claim is made to determine whether the claimed damage or malfunction was caused by abuse, improper installation or other cause
outside this warranty. Mendota is not responsible for any repairs or material purchases that have not received prior written approval
from Mendota.
NOTE: Minor warping of certain parts or discoloration is normal and is not a defect covered by this warranty. Major warping of parts
can be caused by over-firing of your Mendota Fireplace. Over-firing above rated nameplate specification is as contrary to the manufacturer's instructions and may void this warranty.
5. This warranty may not be extended by our representatives or any third party in any manner. The company neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this Mendota product.
6. Mendota may at its discretion, fully discharge all obligations of this warranty by refunding the wholesale price of the defective part(s).
7. All other warranties - expressed or implied - with respect to the product, its components and accessories, or any obligation/liabilities on
the part of the company are hereby expressly excluded. Products made by other manufacturers, sold with the Fireplace or thereafter,
are not covered by this limited warranty. The use of unauthorized components will make this warranty null and void.
4. This warranty shall be effective only if the original purchaser of the Mendota appliance is registered with Mendota Division
(30) days of the date of purchase. Such registration or the failure to register shall not be deemed to create any obligation or liability by
the manufacturer and this warranty with its conditions and limitations shall be the only procedure for obtaining any rights against the
manufacturer and expresses the sole obligation and responsibilities of the manufacturer which are offered to the original purchaser and
accepted upon purchase of the appliance.
5. Mendota Division, reserves the right to make changes at any time without notice, in design, material, specifications, prices and the right
to discontinue styles and products.
6. Some states do not allow the exclusion of limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have
other rights which vary from state to state.
within thirty
58
Page 60
Document #85-03-00815
Johnson Gas Appliance Company
520 E Avenue N.W. - Cedar Rapids, IA 52405
Mendota Hearth Division
WEBPAGE: www.johnsongas.com
or www.mendotahearth.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.