Memorex MVDR2102 Schematic

DVD+R/RW PLAYER
MEMOREX MVDR2102
SERVICE MANUAL
K466UB
CAUTION: Before servicing the chassis, read the “IMPORTANT SERVICE SAFETY INFORMATION” section on
page 2 of this manual.
SPECIFICATIONS
z GENERAL SPECIFICATION
z DVD Record z Record external signal on DVD+R, DVD+RW z Plays: VD+R/DVD+RW/DVD/CD/SVCD/VCD/JPEG/CD-
MP3/CD-R/RW
z TV system: NTSC z Built-in Dolby digital decoder, DTS digital out z OSD languages z Recording mode (based on 4.7GB DVD, single-sided,
1layer)
HQ = 60mins (Highest-level picture quality/ applicable to record high definition data from DV) SP = 120mins (Standard picture quality, similar to DVD/ record video signals at DVD picture quality) LP = 180mins (Long Play Mode) EP = 240mins (Long time recording mode, picture quality better than VHS/ substitute for VCR) SLP = 360mins (Ultra long time recording mode, picture quality better than VHS/
programs or contents
SEP = 420mins ((Super Extended Play Mode)
z Audio Video connector::
Front panel: Composite Audio-Video IN/S-Video IN/DV IN Rear panel: Composite Audio-Video /S-Video IN & OUT TV-RF IN & OUT/Coaxial-Optical OUT
z Audio-Video Cord included z Multifunction remote control z Power supply & consumption:
Operating power supply: AC100V ~ 240V, 50Hz/ 60Hz. Power consumption: 35W Standby-mode power consumption: 2W
z DIMENSION OF UNIT:
430(W) x 325(D) x 55mm
applicable to record long-time
)
CONTENTS
IMPORTANT SERVICE SAFETY INFORMATION................2
DISASSEMBLY FOR REPAIR .................................................3
WIRING DIAGRAM……………………………………....……4
BLOCK DIAGRAM....................................................................5
CIRCUIT DESCRIPTION .......................……………….....6~17
PARTS LIST ..........................................…………............ 18~28
EXPLODED VIEW (UNIT ) ...................................................29
SCHEMATIC DIAGRAMS.................................................30~44
PRINTED CIRCUIT BOARDS.......................................... 45~56
Note: Follows a policy of continuous advancements in development. For this reason specifications may be changed without notice.
IMPORTANT SERVICE SAFETY INFORMATION
1. SAFETY PRECAUTIONS
Before returning a unit to the customer, always make a safety check of the entire unit, including, but not limited to the following items: a. Be sure that no built-in protective devices are defective and/or have been defeated during servicing. (1) Protective shields are provided to protect to protect both the technician and the customer. Correctly replace all missing protective shields including any removed for servicing convenience. (2) When reinstalling the chassis and/or other assemblies in the cabinet, be sure to put back in place all protective devices, including, but not limited to, nonmetallic control knobs, insulating fishpapers, adjustment and compartment covers/shields and isolation resistor capacitor networks. Do not operate this unit of permit it to be operated without all protective devices correctly installed and functioning. b. Be sure that there are no cabinet openings through which an adult or child might be able to insert their fingers and contact a hazardous voltage. Such openings include, but are not limited to, excessively wide cabinet ventilation slots, and an improperly fitted and/or incorrectly secured cabinet back cover. c. Leakage Current Hot Check - With the unit completely reassembled, plug the AC line cord directly into a AC outlet. (Do not use an isolation transformer during this test.) Use a leakage current tester or a metering system that complies with American National Standards institute (ANSI) C101.1 “Leakage Current for Appliances” and Underwriters Laboratories (UL) 1410, (50.7). With the unit AC switch first in the ON position and then in the OFF position, measure from a known earth ground (metal water pipe, conduit, etc.) to all exposed metal parts of the unit (antennas, handle bracket, metal cabinet, screwheads, metallic overlays, control shaft, ect.), especially any exposed metal parts that offer an electrical return path to the chassis. Any current measured must not exceed 0.5 milliamp. Reverse the unit power cord plug in the outlet and repeat test. ANY MEASUREMENTS NOT WITHIN THE LIMITS SPECIFIED HEREIN INDICATE A POTENTIAL SHOCK HAZARD THAT MUST BE ELIMINATED BEFORE RETURNING THE UNIT TO THE CUSTOMER.
AC LEAKAGE TEST
(READING
TEST ALL EXPOSED
DEVICE
UNDER
TEST
METAL SURFACES
2-WIRE CORD ALSO TEST WITH PLUG REVERSED (USING AC ADAPTER PLUG A REQUIRED)
LEAKAGE CURRENT TESTER
SHOULD NOT BE ABOVE
0.5mA)
EARTH GROUND
d. Insulation Resistance Test Cold Check (1) Unplug the power supply cord and connect a jumper wire between the two prongs of the plug. (2) Turn on the power switch of the unit. (3) Measure the resistance with an ohmmeter between the jumpered AC plug and each exposed metallic cabinet part on the unit, such as screwheads, antenna, control shaft, handle brackets, etc. When the exposed metallic part has a return path to the chassis, the reading
ANTENNA TERMINAL
EXPOSED
METAL
PART
OM
OHMMETER
should be between 1 and 5.2 Megohm. When there is no return path to the chassis, the reading must be “infinite”. If it is not within the limits specified, there is the possibility of a shock hazard, and the unit must be repaired and rechecked before it is returned to the customer.
2. PRODUCT SAFETY NOTICE
Some electrical and mechanical parts have special safety related characteristics which are often not evident from visual inspection, nor can be protection they give necessarily be obtained by replacing them with components rated for higher voltage, wattage, etc. Parts that have
special safety characteristics are identified by a
¡I
on schematic and parts list. Use of a substitute replacement that does not have the same safety characteristics as the recommended replacement part might create shock, fire, and/or other hazards. Product Safety is under review continuously and new instructions are issued whenever appropriate.
3. SERVICING PRECAUTIONS CAUTION: Before servicing the unit covered by this service manual and its supplements, read and follow the SAFETY PRECAUTIONS on this page. NOTE: If unforeseen circumstances create a conflict between the following servicing precautions and any of the safety precautions, always follow the safety precautions. Remember: Safety First. General Servicing Precautions. a. Always unplug the unit’s AC power cord from the AC power source before: (1) removing or reinstalling any component, circuit board, module, or any other unit assembly. (2) disconnecting or reconnecting any unit electrical plug or other electrical connection. (3) connecting a test substitute in parallel whit an electrolytic capacitor in the unit. Caution: A wrong part substitution or incorrect polarity installation of electrolytic capacitors may result in an explosion hazard. b. Do not defeat any plug/socket B+ voltage interlocks with which the unit covered by this service manual might be equipped. c. Do not apply AC power to this unit and/or any of its electrical assemblies unless all solid-state device heat sinks are correctly installed. d. Always connect a test unit ground lead to the unit chassis ground before connecting the test unit positive lead. Always remove the test instrument’s ground lead last.
4. LASER PRECAUTIONS WARNING!
1. When servicing (in case it is necessary to confirm Laser Beam Emission), be sure not to place your eyes any closer than 1 ft or 30cm from the surface of the Object Lens on the Optical Pickup Block. HANDLING THE LASER PICKUP
2. Laser diodes are extremely susceptible to damage from static electricity. Even if a static discharge does not ruin the diode, it can shorten its life or cause it to work improperly. When replacing the pickup, use a conductive mat on the floor and desk and wear a wrist band connected to ground through a 1M ohm resistor to protect the laser diode from static damage. If the lens should get dusty, blow off the dust carefully from the object.
3. There are no adjustable parts in the pickup assembly. If it is defective, replace the whole pickup assembly. CAUTION: USE OF CONTROLS, ADJUSTMENTS OR PERFORMANCE OF PROCEDURES HEREIN MAY RESULT IN HAZARDOUS RADIATION EXPOSURE.
DANGER: IF INTERLOCK FAILS OR IS DEFEATED, THE LASER LIGHT IS ABLE TO FUNCTION. THE LASER IS INVISIBLE, AVOID DIRECT EXPOSURE TO BEAM.
2
DISASSEMBLY FOR REPAIR
TO DISASSEMBLY THE TOP CABINET
1. Remove the 9 screws (A) from top cabinet.
TO DISSAEMBLY THE FRONT CABINET
2. Remove 9 screws (B) from the top bracket and the front cabinet.
TO REMOVE THE REAR PLATE
3. Remove the 10 screws (C) from the rear plate.
3
WIRING DIAGRAM
4
BLOCK DIAGRAM
5
CIRCUIT DESCRIPTION
DUAL 4-CHANNEL ANALOG MULTIPLEXER /DEMULTIPLEXER: BU4052BCF (U21,37)
INFRARED REMOTE CONTROL TRANSMITTER : PT2222-002 (IC1)
2 3
4 5 6
7
SS
1 2 3 4 5 6KI 7 8 9 10
12 13
KI
KI KI KI KI
REM
V
DD
SEL
OSCO
OSCI
V
24
23
22 21 20
18 17 16 15
1411
KI KI
CCS KI/O KI/O KI/O19 KI/O KI/O KI/O KI/O
KI/O LMP
1 0
0
1
2 3 4
5 6 7
6
CIRCUIT DESCRIPTION
2-WIRE SERIAL EEPROMAT24C16AN-10SI-2.7V (U3)
VOLTAGE REGULATOR: PQ12RD21 (IC201)
7
CIRCUIT DESCRIPTION
MPEG CODEC SOC: MT8105GE (U2)
MULTISTANDARD SOUND PROCESSOR FAMILY: MSP3425G-QG-B8-V3 (U12)
8
CIRCUIT DESCRIPTION
IEEE 1394a-2000 ONE-PORT CABLE TRANSCEIVER/ARBITER: TSB41AB1PHP (U17)
DUAL OPERATIONAL AMPLIFIER: UTC4558 (U10,15)
A OUTPUT
1
A -INPUT
2
8
V +
7
B OUTPUT
A +INPUT
3
6
B -INPUT
V -
4
5
B +INPUT
9
CIRCUIT DESCRIPTION
PWM CURRENT-MODE CONTROLLER FOR FREE RUNNING QUASI-RESONANT OPERATION: NCP1207ADR2G (IC101)
1.0A FIXED AND ADJUSTABLE LOW DROPOUT POSITIVE VOLTAGE REGULATORS: RT9164A-CG (U2,
U516, U1)
10
CIRCUIT DESCRIPTION
VFD MICROCOMPUTER: LC588620B
(U1)
1CH BTL POWER DRIVER IC: BA5962FVM (U515)
11
CIRCUIT DESCRIPTION
6CH POWER DRIVER FOR CD-ROM, DVD-ROM: BD7902CFS (U514)
24 BIT STEREO ADC: WM8738 (U14)
AVDD
CAP
AGND
RIN
ADC
VREF
FMT
CONTROL
INTERFACE
DIGITAL
FILTERS
NOHP
SDATO
AUDIO
INTERFACE
LRCLK
BCLK
LIN
ADC
MCLK
DCVDD
DGND
12
CIRCUIT DESCRIPTION
512K WORDS X 16 BITS X 2 BANKS (16-MBIT) SYNCHRONOUS DYNAMIC RAM: K4S161622H-UC60 (U508)
4(2)M X 8(16) BITS X 4 BANKS (128-MBIT) SYNCHRONOUS DYNAMIC RAM: K4S281632F­UC75 (U500,502)
13
CIRCUIT DESCRIPTION
16-MEGABIT (1M X 16/2M X 8) 3-VOLT ONLY FLASH MEMORY: AT49BV163A-70TU (U5)
THREE-WIRE SERIAL EEPROMS: AT93C66-10SI-2.7 (U512)
14
CIRCUIT DESCRIPTION
24-BIT, 96KHZ STEREO D/A CONVERTER FOR AUDIO: CS4340 (U517)
300/500MA, ULTRA-FAST TRANSIENT RESPONSE LDO REGULATOR: RT-9166/A-25CXL (U503)
TRIPLE 2-CHANNEL ANALOG MULTIPLEXER /DEMULTIPLEXER: BU4053BCF (U39)
15
CIRCUIT DESCRIPTION
8M-BIT [1MX8/512K X16] CMOS SINGLE VOLTAGE 3V ONLY HIGH SPEED ELITEFLASHTM MEMORYAT49BV802AT-70TU (U510)
16
CIRCUIT DESCRIPTION
DVD-DUAL RECORDING RF IC: MT1816E (U513)
DVD DUAL OPTICAL DISK CONTROLLER: MT1818E (U507)
17
Loading...