www.memmert.com | www.atmosafe .net
100% ATMOSAFE. MADE IN GERMANY.
HPPlife
ANIMAL KEEPING CHAMBER HPPlife
SUPPLEMENT TO THE
OPERATING INSTRUCTIONS
CONSTANT CLIMATE
CHAMBER HPP

Willi-Memmert-Straße 90–96
When contacting customer service, always quote the product serial number on the name-
We reserve the right to make changes

About this manual
This is a supplement to the operating instructions for the constant climate chamber HPP. It
for the constant climate chamber HPP carefully before starting. Familiarise yourself with the
you do not understand, or certain information is missing, ask your manager or contact the
The functions described in this manual refer to the latest firmware version.
from the actual appearance. Function and operation are identical.
The operating manual for the constant climate chamber HPP
This instruction manual belongs with the appliance and should always be stored where
whereabouts of this instruction manual. We recommend that it is always stored in a protected
tion, the operating instructions must go with it.

.................................................................................................
........................................................................................................................
....................................................................................................
..........................................................
...........................................................................................
.................................................................................................
...............................................................................................
4. Operation and control 12
.................................................................................................................
4.3 Day/night simulation programme example

Terms and signs used
you of possible dangers or to give you hints that are important in avoiding injury or damage.
Terms used
Signs used

The appliances described in this manual are technically sophisticated, manufactured using
After removing covers, live parts may be exposed. You may receive
an electric shock if you touch these parts. Disconnect the mains plug
the electrical equipment of the appliances.
When loading the appliance with an unsuitable load, poisonous or
appliance to explode, and people could be severely injured or poi-
that release toxic or explosive vapours when heated up (see also
The appliance may only be operated and maintained by persons who are of legal age and
The owner of the appliance
have the required technical knowledge,
were instructed on the appliance and are familiar with the operating instructions at
comply with the requirements
for working with experimental animals in accordance
with the national regulations and laws on keeping experimental animals

work is carried out properly (see operating instructions constant climate chamber HPP);
through corresponding instructions and inspections;
The animal keeping chamber HPPlife is intended for the keeping of laboratory mice. It may
which can release any toxic or explosive vapours at the set temperature or which can explode,
The appliance may not be used for drying, evaporation and baking paints or similar materi-
the direct vicinity of the appliance.
The manufacturer is not liable for any damage, danger or injuries that result from unauthor-
The appliance may only be used in a flawless condition. If you as the operator notice irregu-
ON
344.4
4444.
TEMP
Set
°C
°C
FLAP
40%
TIMER
hd
1002
End Sept.29 22 24
FAN
%0
%
100
ALARM
max
444.4°C
auto
+
/
-
0.0K
min
444.4°C
Switch off the appliance by pressing the

Description
The appliance can heat the interior up to 35 ºC and cool it down to 0 ºC. In addition to
the HPP standard equipment, the appliance features an exhaust air unit in the back of the
Working range
The temperature-humidity diagram (Fig. 2) specifies at what range of temperature and humid-
fication of the air in the appliance possible even at 10 ºC down to 10 % relative humidity:
100
Temperature-humidity working range of animal keeping chambers HPPlife
90
80
70
60
50
Humidity % rH
40
30
20
10
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75
extended range

Technical data
Appliance depth (including door handle) [mm]
Appliance depth (including door handle) [mm]
Working range with illumination

Assemble the exhaust air unit
air unit, the chamber must not be connected to the power supply.
the appliance (Fig. 3, 1).
with the pipe socket into
the entry port in the back
with the eight Torx screws
that the exhaust pipe points
Screw the exhaust air unit
1
2

for the constant climate chamber HPP.
Connection to a central compressed air supply
Connection to a central compressed air supply
With a suitable pressure hose, connect the
the compressed air is not, or not sufficiently,
the front of the appliance ( Fig. 8 ).
After the first start-up, the appliance display is set to
to change the language in the operating instructions
Compressed air connection
Compressed air connection
Compressed air connection
ON
344.4
4444.
TEMP
Set
°C
°C
FLAP
40%
TIMER
hd
1002
End Sept.29 22 24
FAN
%0
%
100
ALARM
max
444.4°C
auto
+
/
-
0.0K
min
444.4°C

The appliance may only be used in accordance with the applicable national regulations and
This chapter merely describes the special functions of the HPPlife appliance. You
344.4
444 4.
TEMP
Set
°C
°C
FLAP
40%
TIMER
hd
1002
End Sept.29 22 24
FAN
%0
%
100
ALARM
max
444.4°C
auto
+
/
-
0.0K
min
444.4°C
344.4
444 4.
TEMP
Set
°C
°C
FLAP
40%
TIMER
hd
1002
End Sept.29 22 24
FAN
%0
%
100
ALARM
max
444.4°C
auto
+
/
-
0.0K
min
444.4°C
4
Activation key for temperature setpoint
Activation key for temperature setpoint
Activation key for temperature setpoint
Setpoint and actual temperature display
Setpoint and actual temperature display
Setpoint and actual temperature display
Activation key for fan speed setting
Fan speed display
Fan speed display
ing manual constant climate chamber
Activation key for timer setting
Humidity control activation key
Humidity control display
Humidity control display
Activation key for LED interior lighting
Display LED interior lighting
Appliance state and programme display
Display LED interior lighting
Display LED interior lighting
Activation key for the appliance state
Appliance state and programme display
Appliance state and programme display
Activation key setting the temperature
Activation key for the appliance state
Activation key for the appliance state
Activation key setting the temperature
Activation key setting the temperature
and humidity monitoring
and humidity monitoring
Activation key for graphic representation
5 13 14 15 161 2 3
ON
ON
TEMP
22.4
37.0
Set
TIMER
TIMER
30m04h
44h:44m
End
13:30 23.11.
End 14:45
°C
°C
FAN
HUMIDITY
30%rh
Set 30 %rh
of °C
max
max
38.5°C
000°C
auto off
+
%
+
0.0K
-
99K
-
Fr 20.10.2010 20:31
12.Sept.2012
Manual Mode
Holz trocknen
aufheizen
09:12h
GRAPH
%rh°C
0 12
13:44
off
0
%
ON
ON
min
000°C
min
35.5°C
auto
LIGHT
100
ALARM
ALARM
19 2011 12 17 186 7 8 9 10

Adjustment options
You can set the following parameters after pressing the corresponding activation key (in any
Adjustment range: 0 to 40 °C
TEMP
Adjustment range: 10 to 90 % rh
Adjustment range: 0 to 100 % in steps of 1%
Adjustment range: 0 to 100 % in steps of 10%
With the help of the MEMMERT software AtmoCONTROL, programme-controlled operation
You must read the software manual AtmoCONTROL in order to acquaint yourself
HUMIDITY
°C22.4
°C
22.0Set
34%
Set
LIGHT
40
FAN
50
70
rh
%rh
%
%

Evening Night Morning
Simulates the day/night cycle in the AtmoCONTROL programme software (example)
Jump target for the daily repetition of the programme when reaching LOOP (7)
Jump back to 1 and repetition of the programme from 3 (31 times)
FAN
Day
FAN
2
1 3 4 5 6 7
JUMP
TARGET
Humidity

Animal Keeping Chamber HPPlife
D32802 | Date 10/2014
englisch
Memmert GmbH + Co. KG
Willi-Memmert-Straße 90-96 | D-91186 Büchenbach
Tel. +49 9122 925-0 | Fax +49 9122 14585
E-Mail: sales@memmert.com
facebook.com/memmert.family
Die Experten-Plattform: www.atmosafe.net