DSN150 Switch-Rated Plugs & Receptacles – 150 A
UL/CSA Ratings
• Max Amperage & Voltage
150 A, 600 VAC
• Switch-Rating (AC Only)
Branch Circuit & Motor Circuit
Disconnect Switching
• Horsepower Ratings
1Ø 7.5 hp
120V
240V
1Ø 20 hp
208V
3Ø 30 hp
240V
3Ø 30 hp
480V
3Ø 75 hp
600V
3Ø 75 hp
• Short Circuit Rating
100kA Close & Withstand
Testing was performed with 225 A RK1
non-time delay Mersen fuses.
10kA Close & Withstand
Testing was performed with 400 A RK1
non-time delay Mersen fuses.
• Environmental Ratings
Type 4X/IP69/IP69K*
* Also meets IP66/IP67 requirements
• Temperature Range
Min -40°F/Max 140°F
See pg 256 for temps below -15°F.
• Wiring Capacity
Min 4 AWG Max 2/0 AWG
Aux Contacts - Prewired w/14 AWG
• Certifications
UL 2682, UL 1682, CSA 182.1
If you have an existing removable and/or
!
permanently attached drawbar, contact
customer service.
Don’t forget to add installation
accessories to your order
!
Voltage Polarity
120V
120 208V
125V
125 250V
208V
208V
250V
250V
277V
277 480V
347 600V
480V
480V
600V
600V
1P+N+G 63-94165 69-94165 63-98165 69-98165
3P+N+G 63-94167 69-94167 63-98167 69-98167
1P+N+G 63-94075 69-94075 63-98075 69-98075
2P+N+G 63-94076 69-94076 63-98076 69-98076
2P+G 63-94162 69-94162 63-98162 69-98162
3P+G 63-94163 69-94163 63-98163 69-98163
2P+G 63-94072 69-94072 63-98072 69-98072
3P+G 63-94073 69-94073 63-98073 69-98073
1P+N+G 63-94045 69-94045 63-98045 69-98045
3P+N+G 63-94047 69-94047 63-98047 69-98047
3P+N+G 63-94147 69-94147 63-98147 69-98147
2P+G 63-94042 69-94042 63-98042 69-98042
3P+G 63-94043 69-94043 63-98043 69-98043
2P+G 63-94142 69-94142 63-98142 69-98142
3P+G 63-94143 69-94143 63-98143 69-98143
Receptacle
(female)
Easy Closing
Mechanism
Poly casing opens to
180° while the metal
casing opens only 90°.
North American UL/CSA Congurations
Part # Part #
Poly Metal Poly Metal
Inlet
(male)
Tabs for latching to
closing mechanism
Main Options
5/16”
hole
See pages 233-242 for detailed
information on these options
!
33
Auxiliary/Pilot
Contacts
Mushroom
Pawl
Padlock Pawl
Closed Lid
Configuration
Recommended for cord
applications to keep lid
tucked in to avoid damage.
Receptacle Options Suffix # Inlet Options Suffix #
With 2 Auxiliary/Pilot Contacts
With 3 Auxiliary/Pilot Contacts
With 4 Auxiliary/Pilot Contacts
With 5 Auxiliary/Pilot Contacts
With 6 Auxiliary/Pilot Contacts
Straight Insertion
Self-Ejecting Connector Release
Mushroom Pawl
Padlock Pawl
Padlockable Mushroom Pawl
Locking Mushroom Pawl
Metal Pawl (on Poly Receptacle)
180° Opening Lid (metal only)
Closed Lid Configuration
With Auxiliary Switch
Notes: + Not UL/CSA listed.
++
Required when mating to rigid mounted male inlet.
Recept # - 262
Recept # - 263
Recept # - 264
Recept # - 975
Recept # - 976
Recept # - 352
Recept # - 354
Recept # - 375
Recept # - 843
Recept # - 375-843
Recept # - 845
Recept # - 824
Recept # - 180++
Recept # - NC
Recept # - 270+
With 2 Auxiliary/Pilot Contacts
With 3 Auxiliary/Pilot Contacts
With 4 Auxiliary/Pilot Contacts
With 5 Auxiliary/Pilot Contacts
With 6 Auxiliary/Pilot Contacts
Self-Ejecting Plug Release
With No Lockout Hole
For Auxiliary Switch
Notes: * Order inlet with P+N+G configuration and receptacle with
P+G configuration.
Order Example: 480V DSN150 + 2 auxiliary contacts
DSN150 Poly inlet 3P+G = 63-98043-262
Inlet # - 262
Inlet # - 263
Inlet # - 264
Inlet # - 975
Inlet # - 976
Inlet # - 338
Inlet # - A155
Inlet # - NNF*

INSTALLATION ACCESSORIES – SIZE 5
Unless indicated otherwise, accessories can be used with either poly or metal plugs and receptacles.
DSN150
DSN
HANDLE w/NPT
3/4” 515P0N07 595P0N07
Poly
HANDLESANGLES
For metal devices only
1” 515P0N10 595P0N10
1 1/4” 515P0N12 595P0N12
Metal
1 1/2” 515P0N15 595P0N15
2” 515P0N20 595P0N20
For available cord grips, see page 165.
POLY HANDLE w/CORD GRIP
METAL HANDLE w/CORD GRIP
For metal devices only
METAL OVERSIZED HANDLE w/NPT
3/4” 795P0N07
1” 795P0N10
1 1/4” 795P0N12
1 1/2” 795P0N15
For metal devices only
2” 795P0N20
2 1/2” 795P0N25
For available cord grips, see page 165.
SANTOPRENE HANDLE
IP66/IP67
POLY HANDLE w/CLAMP & BUSHING
POLY ANGLE
30° 515M3
METAL ANGLE
0° 595M0
Part # Poly Part # Metal
Cable Range Part #
.980 - 1.260" 715P0EP4
1.260 - 1.560” 715P0FP1
1.520 - 1.860” 715P0GP2
1.250 - 1.375" 795P0FS1
1.438 - 1.562" 795P0FS2*
1.562 - 1.688" 795P0FS3*
1.688 - 1.812" 795P0GS1
*May require stripping of cable jacket.
.70 - 1.000” 555P0D25
.984 - 1.377” 555P0D35
1.378 - 1.771” 555P0D45
1.250 - 1.375” 715P0S22
1.438 - 1.562” 715P0S25
1.562 - 1.688” 715P0S27
1.688 - 1.812” 715P0S29
POLY ANGLE WITH METAL BOX w/NPT
BOXESMISCELLANEOUS ACCESSORIES
* 108.7 in
30° 1 1/4” 715C3N12
30° 1 1/2” 715C3N15
30° 2” 715C3N20
3
30° 2 1/2” 715C3N25
Part #
METAL ANGLE WITH METAL BOX w/NPT
30° 1 1/4” 795C3N12
30° 1 1/2” 795C3N15
30° 2” 795C3N20
3
* 111.8 in
30° 2 1/2” 795C3N25
METAL BOX w/NPT
0° 1 1/4” 7T5F0N12
0° 1 1/2” 7T5F0N15
0° 2” 7T5F0N20
0° 2 1/2” 7T5F0N25
NPT on top or bottom (if rotated). For other NPT configurations, contact customer service.
PROTECTIVE INLET/PLUG CAP
31-9A426
PADLOCKABLE INLET/PLUG CAP
DS9MC
CORD GRIP with or w/o MESH
see pg 165
EASY RETROFIT ADAPTER PLATES
see pg 162 Mount to existing boxes.
RECEPTACLE LOCKING PIN
LP-843 Requires Padlockable Pawl option (-843) on receptacle.
For Inlets/Plugs Only.
Covers lockout hole for watertight seal on inlet.
Consult Customer Service for availability.
Aluminum – For Inlets/Plugs Only.
-A155 suffix required to maintain water ingress protection.
* Interior volume with
receptacle installed.
* Interior volume with
receptacle installed.
* Interior volume with
receptacle installed.
30° 595M3
Oversized 30° 795M3
70° 595M7
Mounts on oversize
box only. Order with
7T6F0N25XL box. See
pg 52.
34