Ratings
• Voltage
600 VAC, 250 VDC
• Switch Ratings (AC)
Branch Circuit & Motor Circuit
Disconnect Switching
• Horsepower ratings
120V
1Ø 3 hp
240V
1Ø 7 1/2 hp
2
08V
3Ø 15 hp
240V
3Ø 15 hp
480V
3Ø 30 hp
600V
3Ø 30 hp
• Short Circuit Rating
100kA Close & Withstand
Testing was perf
nt limiting fuses sized at 400%
urre
c
of the highest full load motor ampacity
associated with the devices hp rating.
• Environmental Ratings
IP67
• Temperature Range
Min -40°F/Max 140°F
See pg 194 for temps below -15°F.
• Wiring Capacity
Min 8 AWG Max 3 AWG
Aux Contacts - Max 14 AWG
• Listings
UL, CSA, IEC, CE*
* Contact Customer Service
ormed with RK1
Receptacle (female) Inlet (male)
on’t forget to
D
dd installation
a
accessories to
our order
y
Voltage Polarity Voltage Polarity
120/208V
125V
1
25/250V
208V
208V
250V
250V
277V
277/480V
347/600V
480V
480V
600V
600V
Other voltage configurations are available – contact customer service at 800.433.7642.
3P+N+E 89-64167 3P+N+E 89-68167
1P+N+E 89-64075 1P+N+E 89-68075
2P+N+E 89-64076 2P+N+E 89-68076
2P+E 89-64162 2P+E 89-68162
3P+E 89-64163 3P+E 89-68163
2P+E 89-64072 2P+E 89-68072
3P+E 89-64073 3P+E 89-68073
1P+N+E 89-64045 1P+N+E 89-68045
3P+N+E 89-64047 3P+N+E 89-68047
3P+N+E 89-64147 3P+N+E 89-68147
2P+E 89-64042 2P+E 89-68042
3P+E 89-64043 3P+E 89-68043
2P+E
3P+E 89-64143 3P+E 89-68143
Part # Part #
Metal Metal
120/208V
125V
1
25/250V
208V
208V
250V
250V
277V
277/480V
347/600V
480V
480V
89-64142 2P+E 89-68142
600V
600V
Main Options
Series Switch Rated Plugs & Receptacles
TM
See pgs 171-180 for detailed
information on these options
DECONTACTOR
57
Auxiliary/Pilot
Contacts
Receptacle Options Suffix # Inlet Options Suffix #
With 2 Auxiliary/Pilot Contacts Recept # - 172* With 2 Auxiliary/Pilot Contacts Inlet # - 172*
* Auxiliary/Pilot Contacts are not available on DB devices with 1P+N+E, 2P+N+E or 3P+N+E polarity
DB60 Order Example:
To order 2 auxiliary/pilot contacts on an inlet and
eceptacle add
r
DB60 Metal inlet 3P+E=89-68043
DB60 Metal receptacle 3P+E=89-64043
Appr
included on the order.
-172
opriate accessory part numbers must also be
to the par
t numbers.
-172
-172
Installation Accessories
Handles
DB60
NPT Cable Range
1/2” 6PH12 6H12 .51 - 1.38 – FH611
3/4” 6PH34 6H34 1.250 - 1.375 6PM622 –
1” 6PH1 6H1 1.438 - 1.562 6PM625 –
1 1/4” 6PH114 6H114 1.562 - 1.688 6PM627 –
1 1/2” 6PH112 6H112 1.688 - 1.812 6PM629 –
Poly Metal* Poly Handle Nylon
Handle Handle w/Clamp & Bushing Handle
Angles
Metal 30° Metal 70° Metal Angle Metal Straight Metal Lateral
Angle Angle Oversized 30° Adapter Angle 30°
MA6 89-6A027 MA660 MS6 MAB6
Junction Boxes
NPT Guidelines
Cable Range NPT
.062 - .5 1/2”
.187 - .75 3/4”
.437 - 1.10 1”
.750 - 1.375 1 1/4”
.890 - 1.650 1 1/2”
NPT sizes are determined by the
cable diameter and third party
cord grip.
NPT
1” MB61 89-6A053-080-1
1 1/4”
1 1/2” MB6112 89-6A053-080-112
2”
Metal Metal Box with
Box Metal Angle
MB6114
MB62 89-6A053-080-2
89-6A053-080-114
Miscellaneous Accessories
For Male
Devices Only
Protective
Cap with Mesh
89-6A126 see pgs 167-168
Cord Grip
Order Example
A typical order should include an inlet
part number, a receptacle part number
AND the matching handles, angles or
other required accessories.
Male Inlet with Handle (Plug)
89-68043 + FH611
Female Receptacle with Angle Adapter
89-64043 + 89-6A027
DECONT
ACTOR
TM
Series Switch Rated Plugs & Receptacles
58