MELEXIS US3881L, US3881E Datasheet

US3881
CMOS Low Voltage Hall Effect Latch
US3881 CMOS Low Voltage Hall Effect Latch 3901003881 Rev 4.2 7/23/01 Page 1
Features and Benefits
Chopper stabilized amplifier stage
Optimized for BDC motor applications
New miniature package / thin, high reliability package
Operation down to 2.2V
Applications
Solid state switch
Brushless DC motor commutation
Speed sensing
Linear position sensing
Angular position sensing
Current sensing
Ordering Information
Part No. Temperature Suffix Package Temperature Range
US3881 E SO or UA -40oC to 85oC Commercial US3881 L SO or UA -40oC to 150oC Automotive
* Contact factory or Sale Representative for legacy temperature options
Description
The US3881 is a bipolar Hall effect sensor IC fabri­cated from mixed signal CMOS technology. It in­corporates advanced chopper stabilization tech­niques to provide accurate and stable magnetic switch points. There are many applications for this sensor in addition to those listed above. The de­sign, specifications, and performance have been optimized for commutation applications in 5V and 12V brushless DC motors.
The output transistor will be latched on (BOP) in the presence of a sufficiently strong South pole mag­netic field facing the marked side of the package. Similarly, the output will be latched off (BRP) in the presence of a North field.
The SOT-23 device is reversed from the UA pack­age. The SOT-23 output transistor will be latched on in the presence of a sufficiently strong North pole magnetic field subjected to the marked face.
Functional Diagram
Note: Static sensitive device; please observe ESD precautions. Re­verse VDD protection is not included. For reverse voltage protec­tion, a 100Ω resistor in series with V
DD
is recommended.
Output
GND
V
DD
Voltage
Regulator
Chopper
SO Package Pin 1 - V
DD
Pin 2 - Output Pin 3 - GND
UA Package
Pin 1 - V
DD
Pin 2 - GND
Pin 3 - Output
US3881 CMOS Low Voltage Hall Effect Latch 3901003881 Rev 4.2 7/23/01 Page 2
US3881
CMOS Low Voltage Hall Effect Latch
US3881 Electrical Specifications
DC Operating Parameters: TA = 25, VDD = 12VDC (unless otherwise specified).
Parameter Symbol Test Conditions Min Typ Max Units
Supply Voltage VDD Operating 2.2 18 V Supply Current IDD B<BOP 1.5 2.5 4.0 mA Saturation Voltage V
DS(on)
I
OUT
= 20 mA, B>BOP 0.4 0.5 V
Output Leakage I
OFF
B<BRP, V
OUT
= 18V 0.01 5.0 ì A Output Rise Time tr VDD = 12V, RL = 1.1KÙ, CL = 20pf 0.04 ì s Output Fall Time tf VDD = 12V, RL = 1.1KÙ, CL = 20pf 0.18 ì s
US3881 Magnetic Specifications
DC Operating Parameters: TA = -40 to 150oC, VDD =12 VDC (unless otherwise specified). 1mT=10 Gauss. Parameter Symbol Test Conditions Min Typ Max Units
Operating Point BOP 1.0 5.0 9.0 mT Release Point BRP -9.0 -5.0 -1.0 mT Hysteresis B
hys
5.5 10.0 12.0 mT
Melexis Inc. reserves the right to make changes without further notice to any products herein to improve reliability, function or design. Melexis does not assume any liability arising from the use of any product or application of any product or circuit described herein.
Supply Voltage (Operating), VDD 18V Supply Current (Fault), IDD 50mA Output Voltage, V
OUT
18V
Output Current (Fault), I
OUT
50mA Power Dissipation, PD 100mW Operating Temperature Range, TA -40 to 150°C Storage Temperature Range, TS -65 to 150°C Maximum Junction Temp, TJ 175°C ESD Sensitivity (All Pins) +/- 4KV
Absolute Maximum Ratings