Static Characteristics
VDD= 4.5 to 5.5V, V
Bat
= 6 to 16V, T
amb
= -40°C to +125°C, unless otherwise specified
Parameter
Symbol Condition Min Typ Max Unit
Supply
Power-on-reset Threshold VCC V
CCPOR
3.0 4.0 V
Power-on-reset Threshold VBAT V
BATPOR
3.0 4.5 V
Quiescent Current, ICC + IBAT I
CCBAT
VCC = 5V, VBAT = 12V,
BUS, TxD, SEN/STA, RxD
and NRxD open
50
µA
TxD, SEN/STA, RxD, NRxD
Pull-up Current TxD Ipu -330 -250 -170
µA
Pull-down Current SEN/STA I
pdSEN
170 250 330
µA
Pull-up Current SEN/STA I
puSEN
-330 -250 -170
µA
Input Voltage Low TxD, SEN/STA VIL 0.25 VCC
Input Voltage High TxD, SEN/STA VIH 0.75 VCC
Output Voltage Low RxD, NRxD VOL I
OUT
= 1 mA 1 V
Output Voltage High RxD, NRxD VOH I
OUT
= 1 mA VCC -1.0 V
BUS
Input Voltage Low BUS VIL 0.45 V
BAT
Input Voltage High BUS VIH 0.55 V
BAT
Hysteresis Input Voltage V
HYS
50 mV
Input Resistance BUS R
IN
V
BAT
= 0..40V 400 600 1500
kΩ
V
BAT
= 0..40V, TA = 85°C 1300
kΩ
V
BUS
= 12V 60
kΩ
Output Voltage BUS V
BUS
VBAT = 12V,
SEN/STA = Low,
I
BUS
= 40mA
1.2 V
I
BUS
= 25mA 1.0 V
Output Sinking Current BUS (current
limiting)
I
LIM
V
BUS
> 3.5V 40 110 mA
Output Sinking Current BUS (before fold
back)
I
BUS
180 mA