MELEXIS MLX12101E Datasheet

MLX12101
Sensor Protection IC
Features and Benefits
Small package (SOT-89) Low dropout voltage (typical 30mV) Large temperature rang e Overvoltage protection Reverse polarity protection Low supply current
Applications
Sensor Overvoltage Protection Sensor Reverse Polarity Protection
Ordering Information
Part No. Temperature Suffix Package Option Temperature Range
MLX12101 E SA N/A -40C to 85C Extended
Functional Diagram
IN OUT
BG
COMP
GND
MLX12101
Description
The MLX12101 serves as a protection circuit where sensible 5V IC's are supplied by long wires that can be short-circuited to the wiring harness of a car. The IC is to be connected between a 5V supply, and a 5V powered remote application. The IC is set on the remote application side, its input receiving the 5V supply through the car wiring, and its output delivering the 5V protected supply to the local application. When the input is below 5.5 Volt, the switch between 5V input and 5V output is closed and the application is powered. When the 5V input goes above 6.8 Volt (This case occurs when the supply wire is short­circuited to battery plus), the output is shut off. When the chip input goes negative ( this is the case when the battery is reversed), a reverse polarity diode prevents the output of going negative.
MLX12101 Sensor Protection IC Page 1 Rev 1.0 22/Feb/01
MLX12101
Sensor Protection IC
MLX12101 Electrical Specifications
DC Operating Parameters TA = -40oC to 135oC, VDD = 5V (unless otherwise specified)
Parameter Symbol Test Condition Min Typ Max Unit Recommended Operating Conditions
Input Voltage 4.5 5.0 5.5 V Output Current 8 mA
Output Signal Specifications
Switch-Off Time (Vou <5V)
Reverse Current Reverse Output Voltage Vss-1 V
Voltage drop-out, Vout-Vin
General Specifiactions
No Load
Overall Supply Current Swoitching Voltage Vt 5.5 6.8 V
Vin jump from 5V to 12V Through Vout with Vdd and Vss connected
Vin = 4.5V Iout = 8mA
Vin = 5V Rload Pin = 22R
150 1000
5 mA
55 mV
500 190 mA
µs
µA
MLX12101 Absolute Maximum Ratings
Parameter Value Unit Comment
Max Operating Voltage Range -14 to 16 V Max Output Current 100 mA Supply Current 0.5 mA Operating temperature -40 to 150 °C Max junction temperature 150 °C
MLX12101 Sensor Protection IC Page 2 Rev 1.0 22/Feb/01
Loading...