Melco GOT1000, GT15-J71E71-100-U User Manual

GT15 Ethernet communication unit
A
)
C
G
S
S
C
T
S
T
A
User's Manual
GT15-J71E71-100
Thank you for purchasing the GOT1000 Series.
Prior to use, please read both this manual and detailed manual thoroughly to fully understand the product.
MODEL GT15-J71E71-100-U MODEL
IB(NA)-0800314-C(0507)MEE
zSAFETY PRECAUTIONSz
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The precautions given in this manual are concerned with this prod­uct. In this manual, the safety precautions are ranked as "DANGER" and "CAUTION".
Indicates that incorrect handling may cause
DANGER
CAUTION
Note that the CAUTION level may lead to a serious accident according to the circumstances. Always follow the precautions of both levels because they are impor­tant to personal safety. Please save this manual to make it accessible when required and always forward it to the end user.
hazardous conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.
1D7M29
[DESIGN PRECAUTIONS]
DANGER
z Do not bunch the control wires or communication cables with
the main circuit or power wires, or lay them close to each other. As a guide, separate the lines by a distance of at least 100 mm (3.94 inch) otherwise malfunctions may occur due to noise.
[INSTALLATION PRECAUTIONS]
DANGER
z Be sure to shut off all phases of the e xter na l pow e r su pp ly used
by the system before mounting or removing this unit to/from the GOT. Not doing so can cause a unit failure or malfunction.
z Before connecting the Bus connection cable to this unit, always
shut off GOT power and PLC CPU power externally in all phases.Not doing so can cause a malfunction.
CAUTION
z Use this unit in the environment given in the general
specifications of the GT15 User's Manual.Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.
z When installing this unit to the GOT, fit it to the connection
interface of the GOT and tighten the mounting screws in the specified torque range. Undertightening can cause a drop, failure or malfunction. Overtightening can cause a drop, failure or malfunction due to screw or unit damage.
[WIRING PRECAUTIONS]
DANGER
z Be sure to shut off all phases of the e xter na l pow e r su pp ly used
by the system before wiring. Failure to do so may result in an electric shock, product damage or malfunctions.
CAUTION
z Use crimp-contact, pressure-displacement or soldering to wire
the connectors for external connections properly using the manufacturer-specified tools. If the connection is incomplete, it may cause the module to short circuit, catch fire, or malfunction.
z Connect the connectors to the unit securely. z Always secure the cables connected to the unit, e.g. run them in
conduits or clamp them. Not doing so can cause unit or cable damage due to dangling, moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault.
[STARTUP AND MAINTENANCE PRECAUTIONS]
DANGER
z Before starting cleaning, always shut off GOT power externally
in all phases. Not doing so can cause a unit failure or malfunction.
CAUTION
z Do not disassemble or modify any unit.
This will cause failure, malfunction, injuries, or fire.
z Do not touch the conductive areas and electronic parts of this
unit directly. Doing so can cause a unit malfunction or failure.
z Exercise care to avoid foreign matter such as chips and wire
offcuts entering the unit. Not doing so can cause a fire, failure or malfunction.
z Do not hold the cable part when unplugging any cable
connected to the unit. Doing so can cause unit or cable damage or a malfunction due to a cable contact fault.
z Always make sure to touch the grounded met al to discha rge the
electricity charged in the body, etc., before touching the unit. Failure to do so may cause a failure or malfunctions of the unit.
[DISPOSAL PRECAUTIONS]
CAUTION
z Dispose of this product as industrial waste.
[TRANSPORTATION PRECAUTIONS]
CAUTION
z Make sure to transport the GOT main unit and /or relevan t unit(s)
in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the GT15 User's Manual, as they are precision devices. Failure to do so may cause the unit to fail. Check if the unit operates correctly after transportation.
Manuals
The following shows manuals relevant to this product.
Detailed Manual
Manual name
GT15 User's Manual
GOT1000 Series Connection Manual
(Option)
(Option)
Manual Number
(Type code)
SH-080528ENG
(1D7M23)
SH-080532ENG
(1D7M26)
Relevant Manuals
For relevant manuals, refer to the PDF manual stored within the drawing software used.
© 2005 MITSUBISHI ELECTRIC CORPORATION
Compliance with the EMC and Low Voltage Directives
When incorporating the Mitsubishi GOT into other machinery or equipment and keeping compliance with the EMC and low voltage directives, refer to Chapter 4, "EMC Directives and Low Voltage Directives" of the manual (GT15 General Description) included with the GOT used. The CE logo is printed on the rating plate of the GOT, indicating compliance with the EMC and low voltage directives. By making this product conform to the EMC directive and low voltage instruction,it is not necessary to make those steps individually.
1. Overview
This User's Manual describes the GT15 Ethernet communication unit. The GT15-J71E7 1- 10 0 is required when performing Ethernet connection or Gateway function with GOT. After unpacking the box of GT15-J71E71-100, please check if the following items are contained.
Product name Model name Quantity Ethernet communication unit GT15-J71E71-100 1 Mounting screw set (2 pieces
of screw,2 pieces of label)
For information concerning necessary OS in case of using GT15­J71E71-100,refer to GOT 1000 Series Connection Manua l .
-1
2. Specifications
2.1 Performance Specifications
The performance specifications of the Ethern et communication unit are indicated below. Refer to the used GT15 User's Manual for the general specifications of the Ethernet communication unit.
Item Specification Data transfer method 10BASE-T 100BASE-TX Transmission
method
Transmission specifications
Maximum node to mode distance
Maximum segment length
Maximum number of cascade connection
Number of units mounted to GOT
Number of GOTs
Connecting condition
connected GOT placing
distance
Internal current consumption(DC5V) 0.22A Weight 0.09kg
*1 This depends on the specifications of the Ethernet network sys-
tem to which the GOT is connected. For the details, refer to the manual of Ethernet module of con­nected PLC.
*2 If multiple network equipme nts (including GOT) are connected
within a segment, the network load would increase. In such condition, the communication performance between GOT and PLC may be declined. The decline of the communication performance may be improved by the following measures.
• Using switching hubs.
• Reducing the number of monitoring devices of the GOT.
Base band Base band
200m 200m
100m 100m
4 steps 2 steps
Only 1 unit can be mounted to the extension unit interface.
128 (Recommend 16 or less)*1*2
100m*1
2.2 Specifications of the related devices
Use the connection cable and the hub which meet the IEEE802.3 10BASE-T/100BASE-TX standa rd .
Specifications
Cable
Item
Non-shielded twisted pair wire (UTP cable) (category3(4, 5))
10BASE-T 100BASE-TX
Connector RJ45jack RJ45jack Hub 10Mbps hub 100Mbps hub
3. Name of the Parts
1)
6)
5)
4)
No. Name Description
1) Mounting screw
2) Interfac e connector
3) Extension connector
4) Ethernet connector
5) 100M LED
6) SD/RD LED
7) Rating plate -
7)
Mounting screws fixed with t he front communication unit or GOT.
Connector connected to the front communication unit or GOT.
Connector with which the back communication unit is fixed.
Connector to which Ethernet cable is connected.
It lights up during 100 Mbps transmission.
It blinks during data sending/ receiving.
Shielded twisted pair wire (STP cable) (category5)
3)
2)
4. Installation Procedure
(1) Power off the GOT. (2) Remove the one extension unit covers of the GOT.
(3) Fit the Ethernet communication unit along th e groove
of the GOT case.
(4) Fasten the Ethernet communication unit by tig htening
its mounting screws (2 places) with tightening torque
0.36 to 0.48 N•m.
(5) When mounting an Ethernet communication unit on
the outer layer, remove the connector cover and the seal. When not mounting any communication unit on the outer layer, stick accessory labels on the top of mounting screws (2 places) to cover the top of them in order to avoid receiving electrostatic. Keep the connector cover fixed. Keep the seal stuck as it is.
ccessory labels
Connector cover
Seal
Point
(1) Grounding work for the 10BASE-T and 100BASE-TX requires
appropriate safety measures. Consult professionals for work details including terminal of connection cables and other plant work such as laying of main cables.
(2) If you remove the Ethernet unit, detach it from specified
direction (shown PULL) so as not to break a connector.
5. External Dimensions
63 (2.48) GOT main unit
3 (0.12)
98 (3.89)
112 (4.41)
2.5
(0.10)
7
(0.28)
8
30.5 (1.2)
21.5 (0.85)
21
(0.83)
(0.31)
Dimensions of X when mounted to the GOT.
8.4” 23 (0.91)
10.4”, 12.1”, 15” 21 (0.83)
Ethernet is a registered trademark of Xerox Corporation, U.S. Other business or product names mentioned herein are a trademark or registered trademark of each company.
X
Unit: mm (inch)
0.5
(0.02
0.4 (0.02)
Warranty
Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to other duties.
For safe use
• This product has been manuf actured as a g eneral -purpose p art f or general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.
• Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi.
• This product has been manufactured under strict quality control. However, when installing the product where major accidents or losses could occur if the product fails, install ap propria te backup or failsafe functions in the system.
ountry/Region Sales office/Tel
U.S.A Mitsubishi Electric Automation Inc.
Brazil MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda.
ermany Mitsubishi Electric Europe B.V. German Branch
U.K Mitsubishi Electric Europe B.V. UK Branch
Italy Mitsubishi Electric Europe B.V. Italian Branch
pain Mitsubishi Electric Europe B.V. Spanish Branch
France Mitsubishi Electric Europe B.V. French Branch
outh Africa Circuit Breaker Industries LTD.
Hong Kong Ryoden Automation Ltd.
hina Ryoden Automation Shanghai Ltd.
aiwan Setsuyo Enterprise Co., Ltd.
Korea HAN NEUNG TECHNO CO.,LTD.
ingapore Mitsubishi Electric Asia Pte, Ltd.
hailand F. A. Tech Co.,Ltd.
Indonesia P.T. Autoteknindo SUMBER MAKMUR
India Messung Systems Put,Ltd.
ustralia Mitsubishi Electric Australia Pty. Ltd.
HEAD OFFICE : 1-8-12, OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212,JAPAN NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission.
500 Corporate Woods Parkway Vernon Hills, IL 60061 Tel : +1-847-478-2100
Rua Correia Dias, 184, Edificio Paraiso Trade Center-8 andar Paraiso, Sao Paulo, SP Brazil Tel : +55-11-5908-8331
Gothaer Strasse 8 D-40880 Ratingen, GERMANY Tel : +49-2102-486-0
Travellers Lane, Hatfield, Herts., AL10 8XB,UK Tel : +44-1707-276100
Centro Dir. Colleoni, Pal. Perseo-Ingr.2 Via Paracelso 12, 20041 Agrate B., Milano, Italy Tel : +39-039-6053344
Carretera de Rubi 76-80 08190 - Sant Cugat del Valles, Barcelona, Spain Tel : +34-93-565-3131
25 Boulevard des Bouvets, F-92741 Nanterre Cedex, France TEL: +33-1-5568-5568
Tripswitch Drive, Elandsfontein Gauteng, South Africa Tel : +27-11-928-2000
10th Floor, Manulife Tower, 169 Electric Road, North Point, HongKong Tel : +852-2887-8870
3F Block5 Building Automation Instrumentation Plaza 103 Cao Bao Rd. Shanghai 200233 China Tel : +86-21-6120-0808
6F., No.105 Wu-Kung 3rd.RD, Wu-Ku Hsiang, Taipei Hsine, Taiwan Tel : +886-2-2299-2499
1F Dong Seo Game Channel Bldg.,660-11, Deungchon-dong Kangsec-ku, Seoul, Korea Tel : +82-2-3660-9552
307 Alexandra Road #05-01/02, Mitsubishi Electric Building Singapore 159943 Tel : +65-6473-2308
898/28,29,30 S.V.City Building,Office Tower 2, Floor 17-18 Rama 3 Road, Bangkpongpang, Yannawa, Bangkok 10120 Tel : +66-2-682-6522
Jl. Muara Karang Selatan Block a Utara No.1 Kav. No.11 Kawasan Industri/Pergudangan Jakarta - Utara 14440 Tel : +62-21-663-0833
Electronic Sadan NO:111 Unit No15, M.I.D.C BHOSARI, PUNE-411026, India Tel : +91-20-712-2807
348 Victoria Road, PostalBag, No 2, Rydalmere, N.S.W 2116, Australia Tel : +61-2-9684-7777
Specifications subject to change without notice. Printed in Japan on recycled paper.
Loading...