We thank you for choosing Watchboot Rebooter RPC-M5C-EA.
The Rebooter RPC-M5C-EA is a remote power control device that is capable of controlling devices on
a network. This product features 4 AC outlets that are individually managed and remotely
manageable through network. Configuring the device to an NTP server allows you to use this device
as a power scheduler.
Our wish is that the Rebooter RPC-M5C-EA will be an indispensable tool in your integrated
networked system.
Make sure to check for newest version of this manual at http://usa.watchboot.com.
Please be sure to thoroughly read this user’s manual before operation.
This manual covers the setup procedure, operation, installation, and user safety guildelines.
Be sure to read this manual thoroughly before use. After reading, store this manual in a safe place.
Included Items
Included with the product are the folloing items. Make sure all of the following are included.
1. User’s Manual(Warranty Certificate)
2. Power Cord
2
Page 3
Warning
Indicates items that may result in death or serious
injury of a person if the product is improperly handled.
Caution
Indicates items that may result in injury of a person or
property damage if the product is improperly handled.
indicates that the act is strictly prohibited. A prohibited
actionis typicallyindicated by astatement or an illustration within
or near the symbol.
The example to the left indicates that disassembly and
modification of the product are prohibited.
indicates that the action must be taken. Specific action
required is indicated by astatement or an illustration within or
near .
The example to the left indicates that the power cable must be
unplugged.
Unplug power cable
Disassembly and modification
are prohibited
Important Safety Information
The following symbols in this manual indicate important messages for the safe use of this product.
The meaning of each symbol is as follows.
Typical alert symbols and signal words
* Property damage shall mean indirect, incidental, or consequential damage to the building,
equipment, domestic animals, etc.
Typical graphic symbols
3
Page 4
Warning
•In case of any abnormal condition: unplug the power cable!
Always discontinue use when you detect abnormal conditions like smoke, abnormal noise, odor, etc.
Fire or electrical shock may result. Immediately unplug the power cable fromthe unit and contact the
retailer from which you purchased the product or Meikyo Electric Co., Ltd.
Unplug power cable
•Never use with line voltage other than 100-120V AC (50/60 Hz).
Never use the product with line voltage other than indicated (100-120 V AC). Never use on voltage
exceeding 125 V, because it may cause damage to the product and fire may result.
120 V AC
•Connect the ground or FG terminal.
Make sure the ground pin of the plug or FG terminal of the product is properly grounded. Otherwise,
electrical shock or malfunctioning may result.
Grounding
•Total 12 A maximum load.
Maximum capacity available from the AC outlets on the backpanel is 12 A combined. Never use the
product with the current exceeding 12 A. Fire or malfunctioning may result.
Max. 12 A
•Never connect multiple devices to a single outlet.
The product must be directly connected to the power outlet on the wall. Do not use the unit with power
strips or extension cords. Fire or malfunctioning may result.
Connection of multiple devices prohibited
•Handle the power cable with care.
Do not place heavy objects on the power cable with a heavy article or place it near the device at high
temperature. This may cause damage to the cabler esulting in fire, electrical shock, or malfunction.
Avoid tampering with the cable or excessively bending or pulling the cable. Excessive bending or
pulling may result in fire or electrical shock. When the power cable is damaged, contact the retailer
from which you purchased the product or Meikyo Electric Co., Ltd.
Avoid rough handling of the power cable
•Never use the unit for devices where extremely high reliability and safety are required.
This product is designed for usewith personal computers and their peripheral equipments. Never use
the product with devices in which extreme reliability and safety are required, such as medical devices.
For use with PC only
4
Page 5
Warning
•Never touch the product or power plug with wet hands.
Do not handle the unit with wet hands. Do not insert or unplug the Power Cord with wet hands.
Electrical shock may result.
Never touch with a wet hand
•Never place water or other liquid above or near the unit.
If liquids such as water enters inside of the unit, fire, electrical shock or malfunction may result.
Never place liquid near the unit
•Never allow a foreign object inside the unit.
If a metallic or combustible object enters inside the unit, fire or electrical shock may result. If a foreign
object should enter into the unit, turn off power immediately, unplug the power cable, and contact the
retailer you purchased the product from or Meikyo Electric Co., Ltd.
Never allow a foreign object inside the product
•Never place or use a combustible article such as a hair spray above or near the unit.
The unit may catch fire froma spark from a switch contact.
Combustible article is prohibited.
•Never touch the unit and the power plug during thunderstorms.
Electrical shock may result. Although each unit comes equipped with a lightning protection circuit,
note that its effect is limited unless the FG terminal is properly grounded.
Never touch during thunderstorms
•Never disassemble or modify the unit.
Because of high internal voltage, never touch the internal parts of the unitor modify the unit with the
cover open. Fire, electrical shock, or malfunction may occur.
Disassembly and modification are prohibited
•When the unit is damaged due to drops etc.
Fire, electrical shock, or malfunction may result with continued use. Unplug the power cables from the
outlet and the AC outlets on the front panel of the product. Contact the retailer you purchased the
product from or Meikyo Electric Co., Ltd.
Unplug all power cables
•Do not use remote power control features with devices that may cause fire, electrocution, or injury.
5
Page 6
Caution
•Do not pull the power cable to unplug.
To unplug the power cable, always hold and pull the plug. Pulling the cable may damage it, and fire
or electrical shock may result.
Never pull the power cable
•Never place the unit in a poorly ventilated space.
Never place the unit in an enclosed space. Heat will accumulate and skin burns, fire, or malfunction
may result.
Never place in poorly ventilated space
•Never place the unit in a space with high temperature.
Never place the unit in a place with direct sunlight or near high temperature devices. Skin burns, fire,
or malfunction may result.
Never place in an area of high temperature
•Cleaning
If the product becomes dirty, wipe the surface with a soft cloth moistened with water or neutral
detergent squeezed well (never wipe electrical contacts like power plug and the connectors by this
method). Never use chemicals (benzene, thinner, etc.). Degradation or discoloration of the surface
may result. Cleaning of the electrical contacts must be made using a dry soft cloth after unplugging
power cables to avoid damage to the unit. The power cable and all other cables connected to the outlets
or connectors of this unit must be unplugged before cleaning. Electrical shock or malfunction may
result.
Unplug power cables
•Never place the unit in a humid or dusty place.
Never place the unit in a humid or dusty place or in a place with oil, mist, or steam, such as on a cooking
table or near a humidifier. Fire or electrical shock may result.
Avoid humidity and dust
•Never place the unit upside down.
Never place the unit upside down. Never use the unit enclosed in cloth or other poorly ventilated
containers. Especially avoid use when a PVC or rubber product is in contact with the unit. Fire or
electrical shock may result.
Avoid using unit upside down
•Make sure to unplug the Power Cord before replacing the fuse.
Make sure to unplug the Power Cord before replacing the fuse.
Make sure to use only UL certified fuse "AC 125 V, 15 A" for replacement in order to
reduce the risks of fire.
use only UL certified fuse
6
Page 7
•Periodically check the power plug and the AC power outlets.
Dust and dirt will accumulate at the power plug and AC outlets when left unattended for a long time,
and when used in such conditions, fire or electrical shock may result. Periodically clean and check the
electrical contacts.
Periodic check
•Use of the product is limited to the United States of America.
The product may fail when used outside of the United States of America due to differences in voltage,
etc.
For use only in the USA
•Never place the unit in an insecure location.
Never place the unitin an insecure location, such as on a shaky stand, areas smaller than the size of this
unit, slanted surfaces, or a surface subject to vibration or shock. Keep this product out of the reach of
children. Personal injury or malfunctioning of the product may result due to dropping or tilting of the
product.
Avoid placing in/on an unsecured location.
•Never place the unit close to a radio or TV set.
The unit may interrupt wireless signals when placed near a radio or TV set.
Avoid a place close to radio or TV set
• Data saving
Before transmitting data, take appropriate steps to backup data when possible. Data may be lost due
to faults in the circuit or in the unit.
Make a backup
•Never place a flower vase, glass, small metal objects, etc. on the unit.
Ingress of water and objects into the unit may cause fire or electrical shock. If water, etc. should enter
inside of the unit, unplug the power plug immediately.
Never place objects on the unit
•Never use this unit as a foothold.
Never step on the unit with your foot. You may fall and suffer personal injury, or unit malfunction may
result.
Never use as a foothold
•About Power Cable Set
Please use the attached Power Cable. Avoid inserting the plug in a downward direction as doing so
may result in the plug falling out more easily.
Use attached Power Cable Set
7
Page 8
FCC Caution
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to
operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur ina particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Declaration of Conformity
Per: 47 Code of Federal Regulations Part 15 - Radio Frequency Devices
We, Meikyo Electric Co., Ltd. declare that our products below satisfy the requirements of
CFR title 47, FCC part 15, subpart B under our responsibility.
Declaration of product:
Product name: WATCH BOOT
Model number: RPC-M5C-EA
Conforms to the following electromagnetic compliance specifications:-
FCC 47 CFR Part15 Radio Frequency Device Subpart B Unintentional Radiators
when the methods, as described in ANSI C63.4-2014 are applied.
Company Name : Meikyo Electric Co., Ltd - Devicenet USA Inc. Office
Address : 4000 Moorpark Ave # 116
San Jose, CA 95117
Telephone Number : 1 (408) 394-5393
Contact Person : Eiji Yasuda
Sales Consultant
8
Page 9
Table of Contents
内容
Table of Contents ............................................................................................................................................................... 9
1. Summary of Features ................................................................................................................................................. 12
2. Individual Parts and Features ................................................................................................................................ 13
4. LED Indicators ........................................................................................................................................................... 15
Ch. 4 Configure / Control with a Web Browser ........................................................................................................ 23
A) System Settings ...................................................................................................................................................... 26
B) Network Settings ................................................................................................................................................... 40
C) Monitoring Settings .............................................................................................................................................. 48
E) Information .............................................................................................................................................................. 57
F) Help ........................................................................................................................................................................... 58
3. Status .............................................................................................................................................................................. 59
A) Basic Information ................................................................................................................................................... 59
B) Monitoring Status .................................................................................................................................................. 60
C) Event Log ................................................................................................................................................................ 63
4. Power Control .............................................................................................................................................................. 65
A) Power Control / Supply ....................................................................................................................................... 65
B) Power Control / Virtual ........................................................................................................................................ 66
C) Multi Power Control ............................................................................................................................................. 67
5. CPU Reset ..................................................................................................................................................................... 68
Ch. 5 Other Settings ......................................................................................................................................................... 69
1. Configure Using Telnet .............................................................................................................................................. 70
9
Page 10
Ch. 6 Other Control Features ......................................................................................................................................... 72
1. Control via Telnet ........................................................................................................................................................ 73
2.Control via Email ........................................................................................................................................................ 74
3.Control via WEB Commands .................................................................................................................................. 75
Parameter List .............................................................................................................................................................. 81
Log List .......................................................................................................................................................................... 88
Control Command List ............................................................................................................................................. 89
2. Setting of heartbeat transmission software ........................................................................................................... 93
3. Setting of Shutdown Server ...................................................................................................................................... 94
A) Setting shutdown script ....................................................................................................................................... 95
B) Setting Wake on Lan.............................................................................................................................................. 97
C) Setting Heartbeat monitoring ............................................................................................................................. 97
D) Outlet delay time setting ..................................................................................................................................... 99
5. Preparation work is now ready for use! ................................................................................................................ 99
10
Page 11
Chapter 1
Introduction
Ch. 1 Introduction
11
Page 12
1. Summary of Features
This product comes equipped with the following features.
1) Four (4) AC outlets that are independently configurable / managed
2) Local and Remote Power Control
・Power control and configuration: Web (html)
・Power control and configuration: Telnet
3) Scheduling Feature for Power Control
・Power scheduling on a weekly basis
4) Monitoring Features for Networked Devices
・Power status monitoring
・Alive monitoring with ICMP Pings (Auto-Ping)
・Heartbeat monitoring
5) Delayed Power-On to Individual Outlets
・Turn on devices in customized order/timed delays upon product startup
6) Power Control and Notification with Email
7) Power/Monitoring Status Notification
8) SNMP Agent
9) Remote/Networked Firmware Updates
10) Device Startup with Magic Packets/Scripted Shutdown
11) Safe OS Shutdown with Scripts
12
Page 13
(1) LAN
Connection port for ethernet cable (8 pin RJ45)
(2) LED (LINK, ACT)
Displays communication status.
(3) Dip Switch
Used to configure modes.
(4) Reset Switch
Restart the CPU without affecting power output.
(5) Pilot LED
Illuminates when power of the unit is switched on
(6) Outlet LED
Indicates power output status of the AC power outlets.
(7) Fuse
Use glass tube fuse15A.
(8) AC Inlet
Connect themain inbound power cable.
(9) AC Outlet
Connectone device to each outbound power outlet.
Caution
If the product is turned on but all LEDs remain off, the fuse may have blown. To
replace the fuse, detach all Power Cords from the outlets, and remove the fuse
cover with a Philips driver. Replace the blown fuse with a new 15A fuse.
2. Individual Parts and Features
Front Panel
Rear Panel
13
Page 14
NO.
POS.
MODE
1
OFF
Normal Operation
ON
Factory Reset
2
OFF
Normal Operation
ON
Unused
3
OFF
Normal Operation
ON
Matainance Mode/Factory Reset
4
OFF
Locked at off
ON
Unused
1
2 3 4
Normal
Operations
OFF
ON
Initialization
/ Maintenance
OFF
ON
Factory Reset
OFF
ON
Caution
Before operating Dip Switches, make sure that you have removed all
Power Cords from the product.
After modification of dip switch settings, be sure to press the reset
button on the front panel. Failing to do so may result in product
malfunction.
Refer to chapter 3-2. for initialization and factory reset procedures.
3. Dip Switch Settings
Dip Switch Functions (Up = off. Down = on.)
Dip Switch Settings
14
Page 15
LED
USE
CONDITION
INDICATION (Light)
LINK
CPU Status
Disconnected Cable
Normal Operation
Abnormailty or Recovery
Normal LAN Connection
0.25s on, 0.25s off
2s on, 0.5s off
0.5s on, 0.5s off
1s on, 1s off
ACT
Network Status
On packet receive
When packet not received
On
Off
4. LED Indicators
The product comes equipped with 3 kinds of LED indicators.
1) ”LINK” and “ACT” LEDs indicates the status of the CPU and network connectivity.
2) Pilot LED
When the product is on, the LED indicator will illuminate orange.
The LED will illuminate green when the product is on and 100BASE-TX is connected.
When the combined number of reboots/logs exceed the customized maximum number “Warning Count”
at Monitoring Setting / Ping / Ping Setting, the LED will illuminate red. (default 12 times)
To indicate a mail server access error, the LED will repeat the following pattern: 2 seconds on, 0.25 seconds
off, 2 seconds on.
3) Outlet LED
i) Indicates the status of the AC outlet.
When on : LED is on.
When off : LED stays off.
ii) When the outlet is undergoing a delayed OFF function, the LED will blink at 1 second intervals.
iii) Alive Monitoring (Auto-Ping)
1. When the outlet is set to ”Reboot” or “Log Only” on abnormaily
a) Alive Monitoring detects an abnormality (and the outlet is on), the LED will follow this
pattern: 2 seconds on, 0.25 seconds off, 2 seconds on.
2. When the monitoring action is triggered “On”
b) Upon initializing of Alive Monitoring, the LED will continue the following pattern until
the product receives a response from all target network devices: 1 second on, 0.25 seconds
off The LED will stay illuminated afterwards. (Power is on)
a) Alive monitoring detects abnormality (power is on). LED will illuminate the following
15
Page 16
sequence: 2 seconds on, 0.25 seconds off, 2 seconds on
b) Upon initializing of Alive Monitoring, the LED will continue the following pattern until
the product receives a response from all target network devices: 1 second on, 0.25 seconds
off The LED will remain off afterwards. (Power is off)
3. When monitoring action is set to “Off”
a) Upon initializing of Alive Monitoring, the LED will continue the following pattern until the
product receives a response from all target network devices: 1 second on, 0.25 seconds off
The LED will stay illuminated afterwards. (Power is on)
“On” and “OFF” settings are not configurable from browsers or the management utility
software. You must directly modify parameter [debOlWdogAction].
16
Page 17
Chapter 2
Installation
Ch. 2 Installation
17
Page 18
Caution
Never install the product upside down. Doing so may result in fire or
malfunction.
Only use the Power Cord that came included with the product.
1. Installation Basics
Follow the procedure to install the product.
1) Position the product at the desired location. Choose a location within reach of a single-phase Power Cord
of equal or greater than AC 100V-120V/12A .
2) Connect a LAN cable to the product’s front panel LAN port.
3) Attached the included Power Cord to the product’s AC inlet. Plug the Power Cord into an outlet.
18
Page 19
Chapter 3
Initial
Configuration
Ch. 3 Initial Configuration
19
Page 20
Caution
The browser must be compatible with JavaScipt and frames.
1. Initial Configuration
To set up remote access to the product, assign a static IP Address.
Connect the product to a PC using a LAN cable.
(Use a patch “crossover” cable when directly accessing the product from a PC)
1) Make sure that there is not a host on LAN or VPN that is assigned the following IP Addresses:
192.168.10.1, 192.168.10.2
2) Configure the PC to the following IP Address and subnet mask:
Do not forget to note the IP Address setting prior to configuration.
IP Address: 192.168.10.2
Subnet mask: 255.255.255.0
3) Use a narrow object like a pen to move Dip Switch 3 to the “On” position.
(This puts the product in maintenance mode, and automatically assigns itself the following IP
Address: 192.168.10.1)
4) Use a narrow object like a pen to press the reset button on the product’s front side panel.
5) Open a web browser on the PC.
Navigate to http://192.168.10.1 to access the product’s initial configuration page.
6) The Management Menu will be displayed.
7) Modify the IP Address setting. Use an IP Address that is compatible and not in conflict with your
network.
8) Complete the configuration by clicking on the “Apply” button at the bottom of the screen.
20
Page 21
Caution
Do not forget to click on the “Apply” button and press the “Reset” button
after modifying settings. Changes to the settings will not be applied until the
“Reset” button is pressed.
Caution
When operating the Dip Switch, gently push the switch with a narrow
object with a round end. Using a sharp object to operate the switch may
cause the sharp point to enter the product and cause malfunctions. Apply
pressure to the entirety of the switch. Operating the switch with the tip over
time may result in breakage of the switch.
9) Use a narrow object like a pen to move Dip Switch 3 to the “On” position.
(This puts the product in normal operation mode.)
10) Use a narrow object like a pen to press the reset button on the product’s front side panel.
11) Close the web browser.
12) Configure and restore the PC to its original IP Address settings.
21
Page 22
Caution
Do not turn off the power while the product is reverting to factory settings.
2. Factory Settings
This will restore the product to its factory settings.
(Do not insert the Power Cord into an outlet yet)
1) Move Dip Switches 1 and 3 to the “On” position (down)
2) Insert the Power Cord into the outlet. This is turn the product on.
3) The LINK LED will illuminate for 5 seconds. While the LED is turned on, press and hold the Reset button
for approximately 1 second.
4) The ACT and LINK LEDs will illuminate upon successful factory reset.
5) If the LINK LED stops illuminating before the Reset button is pressed, remove the Power Cord from the
outlet, and start over from step 1.
6) After factory reset, revert all Dip Switches to the “Off” position (up) before inserting the Power Cord into
an outlet.
7) The product has now been reverted to its factory settings. Initialize the product by following the steps
outlined in the previous section, “Initial Configuration.”
22
Page 23
Chapter 4
Configure / Control
with a Web Browser
Ch. 4 Configure / Control with a Web Browser
23
Page 24
Caution
The Web Browser must be compatible with JavaScript and Frames. Do not
use special characters such as “?”, “=“, “%”, “&”, “,” (comma), and double
quotation marks.
This product is compatible with Internet Explorer ver. 11 or later.
1. Login
To access the product via internet, you must have correctly configured all applicable network devices. Follow
instructions in the products’ manuals. (Do not use proxy)
1) Launch the Web Browser. Navigate to the IP Address assigned to the product.
(e.g., 192.168.10.1)
If the http port is assigned the default port number “80”, navigate to
http://192.168.10.1
If the http port is assigned port number “500”, navigate to
http://192.168.10.1:500
Login Screen
2) Enter the user ID and password. Click on the “login” button to continue.
User ID (default): admin
Password (default): magic
3) The Basic Information Page is displayed.
24
Page 25
Caution
The Basic Information page is designed to only display the product’s basic
system status information. You cannot configure / control the product from
this page.
Basic Information Page
25
Page 26
2. Configuration
A) System Settings
a) Basic
1) Click on the “System” button on the left panel of the page. The “System Settings / Basic” page will
be displayed.
System Settings / Basic
26
Page 27
Default
:
0
Acceptable Values
:
-1 to 3600 (seconds)
“-1”
:
Disable OFF function for this outlet. This outlet is only
controllable with the REBOOT function.
“0” : Immediately turn off the outlet
“1” to “3600”
:
OFF function is delayed after the configured time in
seconds.
(i) Device Settings
Configure the Settings on your unit (product)
Device Name: Assign this unit a name. (Note: maximum 19 characters)
Location: Assign a location name for this unit. (Note: maximum 63 characters)
(ii) Outlet Settings
Outlet Name: Assign names to individual Outlets. (Note: maximum 20 characters.)
“OFF”(OFF Delay)
Configure OFF delay settings for individual outlets. When using a shutdown script, make sure to modify
this setting to give the target device ample time to safely shut down. Configuring this setting to “-1” will
disable the OFF function for this outlet. This means the outlet is only controllable with the REBOOT function.
This setting is useful to avoid turning the device off upon router/hub freezes and hang-ups. (This allows you
to avoid disabling the network connectivity with the power off function). This setting is also applicable for
the following situations.
・OFF functions for individual outlets
・Simultaneous OFF function for all outlets
“REBOOT” (Turning On the Outlet)
Modify the time it takes for the outlet to turn on after turning an outlet off. This allows sufficient time for a
device to reboot. The following are the parameters for this setting.
Default: 10
Acceptable Values: 8 to 3600 (seconds)
“ON” (On Delay)
This value is used when “All Outlets” are given “ON” command or “REBOOT” command. Modify the order
and interval in which each outlet would be turned on. You may customize the order and timing in which
each outlet would turn on. This setting is useful and applicable for the following functions:
・When all outlets are given the ON command
・When all outlets are given the REBOOT command
27
Page 28
Default
:
No. 1: 1 No. 2: 2 No. 3: 3 No. 4: 4
Acceptable Values
:
-1 to 3600 (seconds)
“-1”
:
Disable automatic ON function for this outlet.
“0” : Immediately turn on the outlet.
“1 to 3600”
:
ON function is delayed after the configured time in
seconds.
Default
:
No. 1: 1 No. 2: 2 No. 3: 3 No. 4: 4
Acceptable Values
:
-1 to 3600 (seconds)
“-1”
:
Disable automatic ON function for this outlet.
“0” : Immediately turn on the outlet.
“1 to 3600”
:
ON function is delayed after the configured time in
seconds.
“START”
This value is used when the power of this device is turned on. Modify the order and interval in which each
outlet would be turned on. You may customize the order and timing in which each outlet would turn on.
“All Outlets Reboot (sec)”
Modify the time delay setting for when all outlets are given the REBOOT command.
Note: This is not relected when individual outlets are given the REBOOT command.
・When all outlets are given the REBOOT command
Default: 10
Acceptable Values: 8 to 3600 (seconds)
(iii) Outlet Link Settings
Link outlets together.
Example: If No. 1 (Outlet 1) is linked with Outlet 2, when Outlet 2 is turned on, Outlet 1 is also
turned on.
(iv) Front Panel Settings
Enabled: Each LED flashes in relation to OFF Delay or PING monitering.
Disabled: PILOT and OUTLET LED blinking feature is disabled. They will either be on or off.
Default: Enabled
28
Page 29
a)-1 Time Setting
Click on the “Time Settings” button. “System Settings / Basic / TimeSet” page is displayed.
System Settings / Basic / TimeSet
To set the product’s time settings using PC time settings click the “Apply” button in the “Time
Settings” section to synchronize product’s time settings to your PC.
To synchronize the product to an NTP server, follow the instructions below:
a. Type or paste an NTP address into the “NTP Server” section.
b. Type the number of minute interval in the “NTP Interval” section
(default is 6).
c. Choose the correct time zone in the “Time Zone” section. Select the radio button to indicate
whether or not Daylight Savings Time is in effect.
29
Page 30
b) Advanced
Click on the “Advanced” button in the System Settings page.
(i) Registry List
Click on the “Text List” to open a new tab/window which displays the entire configuration
registry for the product.
With this feature, you can review settings and configurations. You can see all the detailed settings
for the product – even settings that are displayed on the Web Interface.
(ii) Equipment Control
Firmware Page
30
Page 31
Click on “Firmware Upgrade” to conduct a Firmware Upgrade.
On this page, you will be given information such as the unit’s Firmware Version and Model
type
Version Upgrade Method
(1) Connect to the Online Upgrade Server
Click on “Start” to initiate a firmware version upgrade through the internet. The product
will attempt to download and install the latest firmware from the server.
Caution: Do not turn off the product when it is undergoing a firmware version upgrade.
(2) Local File
Version upgrade files may be provided through our website or emails. The following shows
how to upgrade using these files.
1) Click the "Load" button in "Version Upgrade Method" section. The "Firmware File
Selection" page will be displayed.
2) On this screen, click "Choose File" button, navigate to and select the vup file.
3) Then click "Send" button and wait around 3 minutes. Note that the page will remain
unchanged during the upgrade process!
4) When the version upgrade is completed successfully, you will see the page as seen on the
right. The message "(00)Successful completion" also means the upgrade process was
completed successfully.
31
Page 32
WOL Packet(s) Max Count
Default
:
2 (times)
WOL Packet Interval(sec.)
Default
:
15
Outlet 1-4
MAC Address
Default
:
00:00:00:00:00:00
Virtual Outlet Name
:
Assign a name to each virtual outlet.
Maximum 20 characters. (Alphanumeric)
MAC Address
Default
:
00:00:00:00:00:00
ON Delay (Sec.)
Default
:
0
In case error code such as "05" or "31" displayed on screen, please contact Meikyo Electric
Co., Ltd...
5) You may now click the "Top Page" button to navigate to the default page.
6) The Version Upgrade process is now completed, and you must now perform a CPU Reset.
To perform this task, click the "CPU Reset" button in the left panel of the screen, and wait
for about 10 seconds.
(iii) Wake On Lan
Send a Magic Packet to start up a Wake-on-LAN compatible device.
Note: These items apply to both “Link with Outlet Wake On Lan” and “Virtual Outlet [Wake
On Lan].
(iv) Link with Outlet Wake On Lan
(v) Virtual Outlet Settings [Wake On Lan]
Virtual Outlets
Virtual Outlets are not physical outlets. The purpose of Virtual Outlets is to utilize Wake on Lan features on
devices by sending Magic Packets to initial remote start ups.
32
Page 33
Caution
Leaving the the setting page without clicking on the “Apply” button will
discard any and all changes made.
Note: A Magic Packet is sent when the outlet is turned ON.
Once changes are made to the settings, click on the “Apply” button.
33
Page 34
b)-1 Shutdown
Set up and configure Shut Down Scripts.
Script Settings Page
⚫ Click on the “Advanced” button in the System Settings. Click on the “Shutdown” button. This
will open the shutdown settings page.
⚫ Select the outlet for which you want to confirm/modify shutdown settings.
(i) Script Registration
Click on the “Script Edit” button to open the script editor.
a. You may edit the script within the editor. You may also paste scripts from other programs
and text editors.
b. Alternatively, you may upload script files from a local folder. Click on “Load” once you
have selected the file to display the script in the editor.
c. Note the Error Code if there are any. (for reference)
34
Page 35
(i)-1 Script Editor
(i)-1-1 Script File Specification
Load script files from a local folder. Click the “Load” button after selecting the file to display the
script in the editor.
(i)-1-2 The power OFF by the exit code of when the script error.
Error Code
When the end code exceeds this value, the unit will not turn power off to this device.
If the value is “0”, the outlet will turn OFF only when the error code is “0”.
If the value is “255”, the outlet will turn OFF under any value.
For detailed explaination on using shutdown scripts, refer to “Chapter 7 – Shutdown Script”
(ii) Script Settings
Select the appropriate radio button to enable or disable scripts for this outlet.
35
Page 36
Caution
Leaving the the script editor page without clicking on the “Apply” button
will discard any and all changes made.
Script Execution
:
Enabled / Disabled
Script Number
:
1 (Default - Preset Windows Shutdown Script)
IP Address
:
Enter IP Address of the device which is to be shut
down.
Port Number
:
0 (Default)
Login ID
:
Maximum 16 characters. (alphanumeric)
Password
:
Maximum 16 characters. (alphanumeric)
Shutdown Ping Addr
:
Shutdown Ping Interval
:
0 (Default)
Shutdown Ping Count
:
0 (Default)
Shutdown Ping Max
:
0 (Default)
Message
:
36
Page 37
User Type
Monitor Status
Control Power
Change Settings
Ident (Max 10)
Yes
No
No
Control (Max 10)
Yes
Yes
No
Admin (Max 5)
Yes
Yes
Yes
Caution
TELNET password must be changed independently.
c) Security
User Account Settings Page
User Type and Privileges
The table below shows what each user type is able to do.
Note: User name must be 8 characters or fewer. (No duplicate names. Do not use “@”)
Password must be 16 characters or fewer. (Duplicates possible)
1) After making changes to the settings, click on the “Apply” button.
37
Page 38
IP Filter
:
Enabled / Disabled
Address
:
0.0.0.0(Default)
(Max 10 addresses)
Monitoring Status
:
Hide / Show
Virtual Outlet Control
:
Hide / Show
Power ON Button
:
Hide / Show
Power OFF Button
:
Hide / Show
Power Reboot Button
:
Hide / Show
Outlet 1-4 Relevance
:
Hide / Show
All Outlets Control Button
:
Hide / Show
c)-1 Filter
1) Click on “Filter” button from the Security Settings page. This will open the Filter Settings page.
Filter Settings Page
(1) IP Filter Settings
(2) Ident / Control User Permission Settings
38
Page 39
Caution
Leaving the the filter settings page without clicking on the “Apply” button
will discard any and all changes made.
When “Hide” is selected, the corresponding elements are hidden from the WEB UI page when logged in as
Ident / Control accounts.
39
Page 40
B) Network Settings
Confirm and modify network settings for the product.
a) Basic
Basic Network Settings Page.
40
Page 41
IP Address
Default
:
192.168.10.1
Subnet Mask
Default
:
255.255.255.0
Default Gateway
DNS Server Address
DHCP
: Enabled / Disabled
NTP Server
Default
:
HTTP
: Enabled / Disabled
HTTP Port
Default
:
80
HTTP Authentication
: None / Basic / Digest
Default: DigSET est
Realm Name
Default
:
RPC-M5C-EA
(Maximum 20 characters.)
Nonce Time (sec)
Default
:
180
(30 to 30000)
TELNET
: Enabled / Disabled
TELNET Port
Default
:
23
Remote Telnet IP
Remote Telnet Port
Default
:
23
Link Speed
Default
:
Automatic Detection
100Mbps Full Duplex
100Mbps Half Duplex
10Mbps Full Duplex
10Mbps Half Duplex
Auto Logout
Enabled / Disabled
Login Timeout (sec)
: Number of seconds before automatically logged out.
Automatically Refresh Page
: Enabled / Disabled
Refresh Interval (sec)
: Interval between auto page refresh.
Direct WEB Command
: Enabled / Disabled
(i) Network Settings
(ii) Related Settings
(iii) Direct WEB Command Settings
2)Click the “Apply” button after modifying settings.
41
Page 42
Caution
Leaving the the settings page without clicking on the “Apply” button will
discard any and all changes made.
42
Page 43
b) Advanced
Confirm and modify advanced network settings.
Advanced Network Settings Page
(i) Network Tests
Click on the “Send Test” button. In the Send Test page, you may click on each outlet’s “Send WOL” button
to initiate a WoL test. This should send a Magic Packet to the networked device with registered MAC address.
You can do “Mail Test” and “Ping Test” on this page.
43
Page 44
SET GET Settings
: Enabled / Disabled
GET Community Name
Default
:
Public
(Max 20 characters)
SET Community Name
Default
:
public
(Max 20 characters)
TRAP Community Name
Default
:
public
(Max 20 characters)
Manager Trap
: Enabled / Disabled
Authentication Trap
: Enabled / Disabled
Trap IP Address 1-8
: (Max 8 IP Addresses)
SNMP Filter Function
: Enabled / Disabled
Filter IP Address
Filter Mask 1-10
Default
:
255.255.255.255
(Max 10 Addresses)
Staus Notification
: Enabled / Disabled
IP Address 1-3
Port
Default
:
5000
Send Interval
Default
:
300 (sec.)
Group Designation
:
Disabled / Group 1-8
(ii) Basic SNMP Settings
(iii) SNMP Filter Settings
(iv) Status Notification
(v) Multi Power Control Reception
44
Page 45
Control Side MAC Address
:
Enter MAC Address
Caution
Leaving the the settings page without clicking on the “Apply” button will
discard all changes made prior. For certain settings, you must also perform
a CPU Reset for the changes to be applied.
What is Multi Power Control?
Mutil Power Control allows users to control up to 8 groups of Rebooters at once or as group. Broadcast
Packets are used. Designate this unit’s group using Group Designation. Enter the MAC address of the device
used to control the groups to only allow said device to control the grouped Rebooters.
3) Click the “Apply” button after modifying settings.
c) Mail Settings
Register email addresses to which the unit will send monitoring / status abnormality / recovery emails.
45
Page 46
Check Interval (min)
Default
:
3
Retry Interval (sec)
Default
:
10
(Send count based on parameter mailRetryCount. Default:3 times)
SMTP-Auth
: Enable/Disable
[CRAM-MD5]
[LOGIN]
[PLAIN]
APOP
: Enable/Disable
Control Command
:
Enabled / Disabled
Note: If you moniter mail server, this value needs to be
“Enabled”.
Control UserName
:
(Maximum 63 characters.)
Control Password
:
(Maximum 63 characters.)
Mail Subject
Choose from 9 options
None, Device Name, Location, IP Address, MAC
Address, Event Content (Description), User Comment
1-3
Body Line 2-8
Choose from 9 options
None, Device Name, Location, IP Address, MAC
Address, Event Content (Description), User Comment
1-3
Destination Address
Set up the list of addresses that will receive notification from the unit.
Set up to maximum of 8 addresses.
Note: Mail Control Command can be used only from the mail addresses configured in this
value.
(i) Mail Server Settings
Configure the settings according to your account information given to you by your provider. (User Name,
Password, Mail Address, Receive Server name, Receive Port, Send Server name, Send Port)
(ii) Mail Settings
(iii) Notification Destination Address
46
Page 47
F1: Ping
F2: None
F3: Schedule
F4: Heartbeat
Log Send Count
: When the number of logs set in this item is updated, logs are sent to the
email addresses specified at “Notification Destination Address”.
(Maximam: 20) (When this item is set to zero, no log is sent.)
Caution
Leaving the settings page without clicking on the “Apply” button will
discard all changes made prior. For certain settings, you must also perform
a CPU Reset for the changes to be applied.
Even if you choose to only utilize the mail sending feature and not the POP
certification feature, a user name and password is still required.
Data in the mail server will be deleted after being checked between mail
checks.
(iv) Notification Destination Conditions
(v) Mail Server Error Messages
Displays errors when there is a problem sending a mail.
Check the “Clear” box and click “Apply” to clear errors.
1) Once changes to settings are complete, click “Apply”.
2) You can send test mail from Network Settings / Advanced / Send Test page. On that page, click
“Send” button and click “OK” to send a test mail.
47
Page 48
(1) Monitoring
:
Enter the target IP Address or Domain Name to monitor.
Maximum 4 monitoring addresses can be set per outlet.
Example:IP Address – 192.168.0.1
Example:Domain Name – usa.watchboot.com
(2) DG
(Default Gateway)
:
Check to set the default gateway as the monitoring address.
(3) Send
:
Number of ping tests to determine whether the device is connected and
running.
C) Monitoring Settings
Confirm and modify monitoring settings for the product.
a) Ping Settings
1) Click the “Monitoring” button on the left panel. This will open the Monitoring Settings page.
Ping Settings Page
48
Page 49
Enter an integer between 1 and 100
(4) NoAns
:
Number of no-replies within the number of pings sent corresponding to
the “Send” value.
Enter an integer between 1 and 100
(5) Target Number
:
Number of addresses to be considered when monitoring the status of the
device.
Select 1~4
(6) Action
:
Choose what happens when the unit determines the target device to be in
an abnormal condition.
NoAction : Nothing happens.
Reboot : Turns the outlet OFF and ON. This also records the event in
the event log.
Log Only : Records the event in the event log without power control.
(7) Times
:
The number of times to repeat REBOOT.
(8) Interval
:
The interval for repeating REBOOT.
Enter integer between 1 and 60
(9)
PING Send Interval
:
Interval(mins) between each ICMP echo request packet.
(10)
Warning Count
:
The LED flashes in red when the error continues and REBOOT is executed
for a fixed number of times. This number of times.
(11)
Number of Cycles
:
If the error continues even after repeating REBOOT a certain number of
times ->(7), REBOOT will not be executed once. And one hour after the
first REBOOT, this device will do REBOOT several times again ->(A).
The number of (A). (Default 0 means “unlimited”)
2)After modifying settings, be sure click on the “Apply” button.
If the monitoring target is valid, the target number will turn green. If the unit detects abnormality (if the target
is unresponsive to pings) the color will change to red. During recovery, the number will turn yellow.
49
Page 50
Caution
After an action, if device continue to be unresponsive to PINGs, the unit will
continue to ping normally every hour. After the unit’s front panel LED is set
to “abnormal” (red), only one reboot action will be taken per hour. This is to
prevent excessive power cycles if another issue is preventing its normal
operation.
How PING Monitoring Works
The unit sends one ICMP echo request packet at configured interval and waits for a response. The unit will
consider the device (outlet) frozen/unresponsive if the number of no-replies fulfill the configured count
within the number of pings configured in the “send” parameter. The unit will then perform the selected
action.
Example) Send: 5 NoAns: 3
Response Good → Bad → Good → Bad → Good → Bad
In the above case, the device is considered frozen / unresponsive and the unit will perform the selected action.
After the device / outlet is considered frozen/unresponsive, if the unit begins to receive PING reponse from
the device, it will consider the device’s status as “Normal” and continue to monitor the device as usual. If the
unit receives partial response from the monitoring location, it will consider the outlet “Recovering.”
50
Page 51
Connect Error Count
:
Number of errors until action.
Action
:
No Action: Monitoring is not active.
Reboot: Makes an entry in the log, and turns the outlet
ON and OFF.
Log Only: Only makes an entry in the log.
Error Count
:
Displays the number of errors returned from mail
Servers.
Mail Check Interval (min)
:
Interval between mail Server checks
Default 3 mins.
b) Mail Server Monitoring
1) Click the “Mail Server” button in the Monitoring Settings Page. This will display the mail server
monitoring settings.
Mail Server Monitoring Setup Page
(i) Common Actions with Mail Server Settings
Actions are comparable to those featured for Ping Monitoring.
(ii) Current Mail Server Settings
2) After modifying settings, be sure click on the “Apply” button.
51
Page 52
Caution
When using the mail Server monitoring feature, you will need to configure
the Receive server as well. And you need to enable Mail Control Command.
(You may leave the “Notification Destination Address” blank.)
When mail server monitoring and Ping settings are both configured and
active, either of the features is able to perform the configured action.
52
Page 53
Heartbeat
:
Enabled / Disabled
Default: Disabled
Receive IP Address
:
Enter valid IP address of the device that is sending
heartbeat packets. Leave blank to accept packets
from any IP addresses.
Receive Port
:
Enter valid port number to receive Heartbeat
packets.
Default: 9100
Send Port
:
Enter the port number used by the device sending
the Heartbeat packets.
Default: 9100
Reboot Time
:
Enter number of seconds the unit waits after reboot
until it starts to detect
Default: 30
Receive Interval
:
Interval between receiving packets. (1-99 seconds)
Default: 8
Timeout Max Count
:
Maximum number of times the unit will execute
actions. (3 settings, 1-99)
Default: 3
c) Heartbeat Settings
1) Click the “Heartbeat” button in the Monitoring Settings Page. This will display the mail server
monitoring settings.
53
Page 54
Action Max Count
:
Maximum number if times the unit will reboot the
device. (3 settings, 1-99)
Receive
Timeout
None
No Action
No Action
On
No Action
Switch to ON
On Following
Switch from ON to OFF
Switch from OFF to ON
Off
No Action
Switch to OFF
Off Following
Switch from OFF to ON
Switch from ON to OFF
Reboot
No Action
Reboot
Scr & Reboot
No Action
Reboot After Shutdown
Script Execution
Condition
:
Waiting / Timeout / Received Packet
IP address
:
Displays the packet source’s IP address.
Timeout Count
:
Displays the number of timeouts.
Be sure to select the “Enable” radio button for the “Heartbeat” option and click the “Apply” button.
Monitoring Settings
Configure action settings for each outlet.
“Scr & Reboot”
First, the shutdown script will run. Then, after waiting for the number of seconds defined in the "Reboot
Time" parameter, the rebooting of the outlet will commence. (Please note that if the shutdown script is
disabled, only the rebooting of the outlet will occur. This sequence will only run once.)
Packet Status
Condition:
54
Page 55
D) Scheduling Settings
Confirm and Configure Scheduling Features for the unit.
Maximum number of scheduled events: 20
1) Click on the “Schedule” button on the left panel.
55
Page 56
(1)
Check box
:
Enable / Disable selected event
Checked events are enabled.
(2)
Outlet
:
Outlet number to control
All OL (All Outlets)
Outlet 1-4
All vOL (All Virtual Outlets)
Virtual Outlets 1-8,
(3)
Week
:
Effective Days of the Week
All (Everyday)
Sunday Monday Tuesday
Wednesday Thursday Friday Saturday
(4)
Hour
:
Hour for the event
Choose from 1 – 12
(5)
Minute
:
Minute for the event
Choose from 0 - 59
(6)
A/P : Select between AM/PM.
(7)
Action
:
Select an Action which will occur at the configured time.
None: No action.
Reboot: Turn the outlet OFF, then ON.
ON: Turn the outlet ON.
OFF: Turn the outlet OFF.
Mail: Send a mail
Note: For virtual outlets, ON is only available.
2)After modifying settings, be sure click on the “Apply” button.
The following screen is displayed unless the “NTP Server” setting is properly configured in
“System/Basic/Time Setting/NTP Setting”
Please properly configure the “NTP Server” in “System/Basic/Time Setting/NTP Setting” before proceeding.
56
Page 57
E) Information
View various settings for this unit at a glance.
1) Click on the “Information” button in the left panel.
System Information Page
57
Page 58
F) Help
View the help page.
1)Click on the “Help” button in the left panel.
Help Menu page
2) Click on the button to view dedicated pages that explain the subject matter.
58
Page 59
Caution
Basic Information only displays information. This page is not intended for
power control or modification of settings.
3. Status
A) Basic Information
Quickly view the status of the outlets.
1)Click on the “Basics” button under the “Status” section in the left panel.
Basic Information page
59
Page 60
B) Monitoring Status
View the Monitoring Status of the unit.
1) Click on the “Monitoring” button under “Status” section in the left panel.
Monitoring Status Page
60
Page 61
No. : Number for the particular outlet. (1 - 4)
Outlet Name
:
Name of the outlet. You may change the name of each outlet in System
Settings / Basic.
Status
:
Displays the judgment result of PING monitoring and Mail Server
monitoring.
OK: The number of monitoring targets that indicate an error is less than
the number of targets, and the mail server is normal.
NG: The number of monitoring targets that indicate an error is equal to
or greater than the number of targets, or the mail server is abnormal.
ReC (Recovering): After the set operation, the number of monitoring
destinations that indicate an error is less than the number of targets, but
there are monitoring destinations that still indicate an error. Mail server
is normal.
Execute
:
Displays the number of times the action for the outlet has been
performed.
Power
:
ON, OFF
Cond
:
Displays the response status of each monitoring destination for each outlet.
NoRes
:
No Response Count. Displays the number of time outs from ICMP echo pings.
ResTime
:
Displays the response time.
Motion
:
Displays the action to be taken when an error is detected.
None / ON / On following / OFF / Off following / REBOOT / Scr & REBOOT
Executions
:
Shows the number of times the action has been performed.
Packet
:
Displays the reception status of heartbeat packets.
(i) Device Information
Displays information (Device name, Location) about the unit.
(ii) Outlet Monitoring Condition
(iii) Judgement Condition
A quick view of the monitoring settings for each outlet. See Monitoring Settings for details.
(iv) Monitoring Status
(v) Ping Response Time
(vi) Heartbeat Status
61
Page 62
Standby / Receive / TimeOut
Status
:
Displays the number of mail server errors.
(vii) Mail Server Status
62
Page 63
C) Event Log
View the current event log.
1) Click on the “Event Log” button under the “Status” section in the left panel.
Event Log Page
63
Page 64
Previous Page
:
Displays the previous page.
Next Page
:
Displays the next page.
Top Page
:
Displays the top page.
Last Page
:
Displays the last page.
Text Page
:
Opens a new tab / window to display all available log entries.
You may then copy / save the entries.
Clear Log
:
Clears Log (This action cannot be undone)
Caution
Each page only displays up to 100 entries.
Maximum 10 pages.
Maximum 1000 event entries.
2) Click on the circular arrow at the top right corner of the page to refresh the event log.
64
Page 65
ON : Turn ON the outlet’s power.
OFF
:
Turn OFF the outlet’s power.
Reboot
:
Turn the outlet OFF, then ON.
ON : Turn all outlets ON.
OFF
:
Turn all outlets OFF.
Reboot
:
Turn all outlets OFF, then ON.
4. Power Control
Control power for the connected devices.
A) Power Control / Supply
1) Click on “Power Control” button under “Control” section in the left panel.
(i) Device Information
Displays the unit’s name and location.(Refresh to display the latest information.)
(ii) Outlet Information
(ii)-1 All Outlets
65
Page 66
Caution
When turning all virtual outlets on at once, the unit will turn on each outlets in a
sequential, 1-second time-delayed order.
(Delay time, Default)
The OFF time for Reboot is default 10 seconds.
Above values are configurable parameters.
B) Power Control / Virtual
Virtual Outlets
Virtual Outlets are not physical outlets. The purpose of Virtual Outlets is to utilize Wake-on-LAN features
on devices by sending Magic Packets to initial remote start ups.
(i) Device Information
Displays the unit’s name and location.
(Refresh to display the latest information.)
(ii) Virtual Outlets (WOL) / WOL Send
Send a magic packet to initiate device Wake-on-LAN.
You may perform this action for each registered virtual outlets, or all virtual outlets at once.
66
Page 67
Controlled Group
:
Select the group you wish to control.
Operation
:
Action
PowerON PowerOFF Reboot
Send
:
Send the command.
Caution
When turning all virtual outlets on at once, the unit will turn on each outlets
in a sequential, 1-second time-delayed order.
(Delay time, Default)
The OFF time for Reboot is default 10 seconds.
Above values are configurable parameters.
C) Multi Power Control
What is Multi Power Control?
Mutil Power Control allows users to control up to 8 groups of Rebooters at once or as group. Broadcast
Packets are used. Designate this unit’s group using Group Designation. Enter the MAC address of the device
used to control the groups to only allow said device to control the grouped Rebooters.
67
Page 68
Caution
During a CPU Reset, all network functionalities are temporarily disabled.
However, this does not affect the outlets, since it is not a device reboot.
5. CPU Reset
Apply settings modifications.
1) Click on the “CPU Reset” button in the left panel.
CPU Reset page
2) Click on the “CPU Reset” button.
3) Click on “OK”.
4) The message “CPU reset in progress… Please wait…” will blink on the screen. Do not unplug the power
while CPU Reset is in progress.
68
Page 69
Chapter 5
Other Settings
Ch. 5 Other Settings
69
Page 70
IP ADDRESS
:192.168.10.1
TELNET port
: 23
220 RPC-M5C-EA (Noname) server ready
Caution
Telnet connection uses a different password from one used to access the
Web interface. Use the “pass” command to change the password during
telnet connection.
We strongly suggest changing the default password for security purposes.
1. Configure Using Telnet
1) Run a telnet client program and connect to the product’s assigned IP address.
Example:
192.168.10.1
2) Upon successful connection to the unit, the below message is displayed.
Note: “Noname” is the unit’s configured default name.
3) Press any key. A message prompting ID and a password is displayed.
4) Enter ID (Default: admin) and the password (Default: magic), and press the <Enter> key. When
successful, “OK” is displayed.
70
Page 71
Command
Description
LIST
Display all settings and variables for the unit.
WRITE
Write the variable settings to FROM.
&SAVE
Displays all settings parameters for saving and loading.
(For saving and exporting settings)
LOAD_BEGIN
Begin reading setting data.
LOAD_END
End reading setting data.
?variable name
Display the value for the parameter.
.variable name =value
Configure and display value for the variable[parameter].
CPURESET
Reset CPU. (Outlets are not affected.)
Configuring with Telnet
1) Run a telnet client program and connect to the product’s assigned IP address.
2) Enter commands and press the <Enter> key to execute.
(Changes made to certain settings such as IP address will only apply after a CPU Reset.)
Some basic commands available with Telnet
Note: Regarding variables[parameter], please refer to the “Parameter List” (Chapter 8)
About “&save” command
“&save” is used to save, export, and import settings. Upon entering this command, all settings data are
displayed with “LOAD_BEGIN” in the front and “LOAD_END” at the end. Copying/pasting/saving this
string of text will allow for quick and easy import/export of settings. Note that this does not allow for copying
of certain settings, such as passwords. “&save” does not have echo back. Exercise caution when
saving/writing settings, as settings which may cause errors will transfer as is. Longer commands may be
broken into multiple lines (hyphens indicate breaks between longer commands). When importing
commands from file, make sure to set “promptMode” to value 0 or 1.
71
Page 72
Chapter 6
Other Control Features
Ch. 6 Other Control Features
72
Page 73
IP ADDRESS
: 192.168.10.1
TELNET port
: 23
220 RPC-M5C-EA (Noname) server ready
Caution
It is possible for multiple TELNET clients to log in to the unit. Check to see
if other clients are logged in using the “Log” command. Avoid simultaneous
login and control of the unit.
1. Control via Telnet
This product supports Telnet connectivity which allows for remote power control and status capture. The
security security level (ident, control) attributed to the login credentials determine the commands the user
has at his disposal.
(i) Control Through Telnet Connection
1) Run a telnet client program and connect to the product’s assigned IP address.
Example:
192.168.10.1
2) Upon successful connection to the unit, the below message is displayed.
Note: “Noname” is the unit’s configured default name.
3) Press any key. A message prompting ID and a password is displayed.
4) Enter ID (Default: admin) and the password (Default: magic), and press the <Enter> key. When
successful, “OK” is displayed.
5) Enter commands and press the <Enter> key to execute.
Command : See Chapter 8 < Control Command List >
73
Page 74
2.Control via Email
Control the unit via email.
To enable email commands, network settings and mail settings must be properly configured. The only
emails registered as “Notification Destination Address” may use operation to control command. (Network
Settings / Mail)
1. Sending an email to the unit
a) Subject line is not necessary.
b) Enter the “Control UserName” on the first line.
c) Enter the “Control Password” on the second line.
d) Third line onwards are the actual commands.
- Enter the command and press <Enter>
- You may not use the “List” and “&save” commands.
- Type「QUIT」to log out. You may also use “E”, “e”, “Q”, or “q”.
2. After a few minutes, you will receive an email with the result.
74
Page 75
3.Control via WEB Commands
How to transmit commands by WEB
You can directly control the device via WEB commands.
Before using WEB commands, be sure that "Direct WEB Command" is enabled in the Network
Settings / Basic.
WEB commands are primarily for power control, and therefore not used to change settings on the
device.
Fill in the required information in the brackets after the "cmd.htm".
(HTTP Authentication Basic or Digest)
?c= [used command]
0: Standard Time
1: Summer Time
(Standard Time + 1:00)
timezoneOffset
-300
Time difference from UTC of
currently selected time zone
(Read Only)
timezoneName
ET
Name of currently selected time
zone
(Read Only)
*1 Meikyo Remote Power Controller, RPC-M5C-EA Ver. 1.10A
*2 Meikyo 100BASE-TX Driver
87
Page 88
Contents
TELNET Log
Additional Information
Log start
Log Start
PING Transmission
ping
outlet no. Ipaddr no.
No Response from PING
No Echo
outlet no. Ipaddr no.
Freeze Detection (NoAction)
No Action
outlet no.
Freeze Detection (REBOOT)
Outlet Reboot
outlet no.
Freeze Detection (Outlet ON)
Outlet On
outlet no.
Freeze Detection (Outlet OFF)
Outlet Off
outlet no.
Normal / Recovering
Outlet Recovered
outlet no.
Schedule (REBOOT)
Outlet Reboot by Schedule
outlet no.
Schedule (Outlet ON)
Outlet On by Schedule
outlet no.
Schedule (Outlet OFF)
Outlet Off by Schedule
outlet no.
All Outlets ON
MPON
outlet ALL ID (ID: the User)
All Outlets OFF
MPOF
outlet ALL ID (ID: the User)
All Outlets REBOOT
MPOR
outlet ALL ID (ID: the User)
Outlet ON
PON
outlet no. ID (ID: the User)
Outlet OFF
POF
outlet no. ID (ID: the User)
Outlet REBOOT
POR
outlet no. ID (ID: the User)
Login request by email
-->Mail
Ipaddr no. (no.: the configuration number)
Login by email
==>Mail
Ipaddr no. (no.: the configuration number)
Logout by email
<==Mail
Ipaddr no. (no.: the configuration number)
TELNET connection
-->Telnet
IPaddr
TELNET disconnection without
login
<--Telnet
IPaddr
TELNET multiple connetion
>>xTelnet
IPaddr
TELNET login
==>Telnet
IPaddr
TELNET logout
<==Telnet
IPaddr
Web connection
-->Web
Web login
==>Web
Web logout
<==Web
Configuration change
variable set (xxxxx)
[parameter] ID (ID: the User)
Configuration writing (WRITE)
write to FROM
ID (ID: the User)
NTP server connection
NTP --- hh:mm:ss
hour minute second
NTP server connection error
NTP Server Access Error
Email error
Mail Error
Log List
88
Page 89
Command
Description
MPON
Turn all outlets ON.
MPOF
Turn all outlets OFF.
MPOR
Reboot all outlets. (OFF, then ON)
PONn
Turn outlet “n” ON. (n=1-4)
POFn
Turn outlet “n” OFF. (n=1-4)
PORn
Reboot outlet “n”. (n=1-4)
PSRn
Reverse outlet “n” status. (ON to OFF, OFF to ON)
MPONV
Send a Magic Packet to all virtual outlets.
PONVn
Send A Magic Packet after debWakeupInterval. (n=1-8)
PORSn
First, the shutdown script will run. Then, after waiting for the number of seconds
defined in the "Reboot Time" parameter, the rebooting of the outlet will commence.
(Please note that if the shutdown script is disabled, only the rebooting of the outlet will
occur. This sequence will only run once.) (n=1-4)
OLSn
Display Monitoring Status for each outlet. (n=1-4)
Not entering a value for n displays status for all outlets.
Values separated by commas
Outlet No.
Outlet number [1-4]
Power
Power Status [0:Off 1: On]
Judge
Cond.[1:OK 2:NG 3:Recovering]
Action Count
Number of actions executed
Last Ping1
Last ping result from address 1
[1:OK 2:NG]
NoEchoCount1
No. of on-replies from Address 1
NoEchoTime1
Latency of reply from Address 1 (ms)
[ 0: n/a 1: responded 9999: no-reply ]
Last Ping2
Last ping result from address 2
[1:OK 2:NG]
NoEchoCount2
No. of on-replies from Address 2
NoEchoTime2
Latency of reply from Address 2 (ms)
[ 0: n/a 1: responded 9999: no-reply ]
Last Ping3
Last ping result from address 3
[1:OK 2:NG]
NoEchoCount3
No. of on-replies from Address 3
NoEchoTime3
Latency of reply from Address 3 (ms)
[ 0: n/a 1: responded 9999: no-reply ]
Last Ping4
Last ping result from address 4
[1:OK 2:NG]
NoEchoCount4
No. of on-replies from Address 4
Control Command List
89
Page 90
NoEchoTime4
Latency of reply from Address 4 (ms)
[ 0: n/a 1: responded 9999: no-reply ]
VER
Display version information
POS
Display the status for all outlets
Response: mmmm
From left: Outlet 1 - 4
m= 0:OFF 1:ON
XPOS
Display detailed statuses for all outlets
Response: ABXXXX, ABXXXX, ABXXXX, ABXXXX、
From left: Outlet 1 - 4
A= 0: OFF 1: ON
B= 0:OFF Delayed 1: ON Delayed
XXXX= B remaining seconds on timer
ID
Change user ID
PASS
Change the password. Enter the new password twice.
Note: Failure to match passwords will not change the password.
DATE
Format: mm/dd/yy mm: month dd: day yy: year
TIME
Current time settings.
Format: hh:mm:ss hh:hours mm:minutes ss:seconds
PING
Sends ICMP four times.
Example: PING [IP ADDRESS]
IPCONFIG
Displays LAN settings. (Example below)
IP Address 192.168.10.1
SubnetMask 255.255.255.0
DefaultGateway 192.168.10.254
EhternetSpeed 100.0Mbps
CPURESET
Perform a CPU reset.
This command will not affect the unit’s power.
PROMPT=n
0 (no display)
1 (display “>”)
2 (display “unit name>”)
Note: Variable “promptMode” selects the mode.
EXIT
Disconnect from unit. You may also use “E”, “e”, “Q”, or “q”.
LAN 1 (RJ-45) : 10BASE-T / 100BASE-TX
(per IEEE802.3)
Rating
Max. controllable power
120V 12A
Power consumption
Max. 5.8W
Input power voltage
AC100-120V 50/60Hz
Service condition
Temperature: 0-40C
Humidity: 20-85 % (No condensation)
External dimensions
220(W) × 42.6(H) × 165(D)mm
Weight
1.3 kg (without Power Cable Set)
Applicable
standards
FCC Part15 Subpart B, UL60950-1,
RoHS Directive compliant
Specifications
91
Page 92
Appendix A
Example of use:
Media player and
Display
Appendix A Example of use: Media player and Display
92
Page 93
1. Preparation
- Confirm that outlet 1 is connected to Display and outlet 2 is connected to PC as media player in this unit.
- PC(Media Player) is nessary to have heartbeat transmission software, MRC-HB Ver 1.5-190416(mrchb.exe)
and shutdown server, MRC shutdown server Ver 1.0(mrcsdsve.exe).
- Wake on Lan in Windows10 is disabled. Please enable it.
Note: The setting of the number of seconds comes out in the description from here, but it is only an example.
Please adjust to the number of seconds according to the actual system.
2. Setting of heartbeat transmission software
- It keeps sending heartbeats if the condition of Media playback software running on the PC is normal. In the
otherhand, it will stop sending heartbeats if it detect abnormalities. That is the function of this software.
(1) Start MRC-HB Ver
1.5.190416.
Then the screen like right
figure will appear.
Enter the IP address and
5sec. should be set as
interval.
That will generate heratbeat
packet in 5 seconds interval.
About 60 sec. should be set as Start Wait Time. This allows the display to turn on again after the media
player restarts and resumes video playback.
(2) As this software will be added in start up, please click "Add shortcut to starup" button.
93
Page 94
(3) As the next step, click "CPU
resource" button in the same
screen, the right figured
image will appear.
Click "application" button
and sellect media playback
software. If it is VLC player,
then it might be easier to
enter "vlc#0" directly.
For the Counts we will recommend to enter 8 seconds, however that should be longer than interval
value what you have set with (1),
After that please remark "CPU resources Check and "OK" button can be clicked.
(4) You now back to first screen. Please click "Start" button. Hearbeat packet is continoursly sending.
3. Setting of Shutdown Server
- It is server software that allows a PC to receive scripts and shut down. (It is neccesary to have this software
as Windows10 has no Telnet server function.)
(1) Start MRC Shutdown
Server ver 1.0. Then the
screen like right figure
will appear.
94
Page 95
(2) By default it is set as User ID:admin, Password:magic, PORT:8023. Pleas change it according to the use
situation.
(3) In case you want to set reciving the scripts only by specific IP address, you can sellect "allow only the
specified IP address" in "Configure IP Permissions" and enter its IP Address.
(4) Click "OK" button to make the server software being stationed.
4. Setting RPC-M5C-EA
- By WEB browser, enter the IP Address of
this unit then ID and Password will be
required. Then by default you may enter
ID:admin and Password: magic. Then right
screen image will appear.
A) Setting shutdown script
(1) By click "System" button of Settings,
then right figure will appear.
(2) By click "Advanced" button, then right
figure will appear.
95
Page 96
(3) By click "Shutdown" button, then the
settings button for each outlet is
displayed.
- Hereafter it is explained in the case of that outlet 1 is connected to display and outlet2 is connected to PC
as Media player.
(4) Please set as below.
Script Execution should be as enabled.
Script Number will remain as it is, that
means 1 (The shutdown script for
Windows is set by default.)
IP Address should be choiced the
address of PC(Meddia Player) and enter.
Port should be the same number what
you set (2) in Section 3. Deafult is 8023.
Login ID and Password should be the
same one what you set (2) in Section 3.
Shutdown Ping Addr should be IP
address of PC(Media Player). You have to
confirm its shutdown by sending the ping.
Shutdown Ping Interval: recommended
value as 5
Shutdown Ping Count: recommended value as 5
Shutdown Ping Max: recommended value as 2
(5) Click "Apply" button.
96
Page 97
B) Setting Wake on Lan
- The setting requires the Mac address of the PC(media Player).
(1) As the same methods like (1) and (2) of
setting shoutdown script in Section 4,
the right screen figure will appear.
Outlet2 requires MAC Address under
the "Link with Outlet Wake on Lan".
Please enter MAC Address of PC
(Media Player) and click "Apply "
button.
- Settings related to Wake on Lan can be done
with Wake on Lan at this screen.
C) Setting Heartbeat monitoring
(1) Click "SETTING" in screen left
and click the "Monitoring"
button, then right screen will
apper. Then click "heatbeat"
button.
97
Page 98
(2) Please set hereafter as below;
In the Box of Heartbeat Settings
Heartbeat should be
checked as ebabled.
Receive IP Address will be
open. In this case hearbeat
can be received by unlimitted
IP Addresses. If you want to
receive heartbeat packet only
from PC(Media Player),
You may allow to enter IP
Address of PC (Media
Player).
In the Box of Monitoring Settings
Action to be sellected as off
following for the Outlet1
Action to be sellected as
Scr&Reboot for the Outlet2
(3) CPU reset will be required
by click of "Apply" in
lower part of screen.
Please click "CPU Reset"
button in screen left.
(4) The unit is ready to receive heartbeat packet after the warm-up start.
98
Page 99
D) Outlet delay time setting
- When the heartbeat packet stops, outlet 1 is immediately turned off and outlet 2 should be rebooted
shortly after the PC is shut down.
(1) By click
"System"
button of
Settings,
then right
figure will
appear.
By Outlet
settings you
may set 60
seconds as
REBOOT
for outlet 2,
then click "
Apply"
button in
lower part of screen.
- Set to turn on the display 60 seconds
after the heartbeat packet is received
again. (Heartbeat transmit Start
Wait)
(2) About 60 sec. should be set as Start
Wait Time in MRC-HB Ver 1.5-
190416.
5. Preparation work is now ready for use!
- By using heartbeat soft we prepared in (3) of Section 2, you may click "Start" button. Now it will start to
send heatbeat packet.
- You may now start Media Playback via PC(Media Player). Shutdown script will start if you may stop
Media Player.
If you want shutdown temporarily, then you may change IP Address of PC(Media Player) temporarily or
EXIT resident shutdown server software.
99
Page 100
PING no echo
× ×
shutdown
Main Power OFF
movie start
ERRORboot up
Monitors CPU utilization and sends heartbeat packets.
This interval is set at "Interval" of MRC-HB.
This interval is set at "Start Wait Time" of MRC-HB.
CPU utilization continues to be 0%
→Stops sending heartbeat packets
start up
↓Number of "×" to judge "Timeout"→hbTimeoutMax
○○○○×××
×××○ ○○○○ ○
hbInterval(sec.)
P
P
WOL WOL
TELNET Connection
→Shutdown Script Execution
→If Shutdown Ping is set, confirm that there is no response from PING and reboot.
→If Shutdown Ping is not set, reboot immediately.
debOlShutdownPingIntervaldebWakeupMaxCount
debOlShutdownPingCount
debWakeupInterval
debOlShutdownPingMax
Scr&Reboot
Checking Shutdown PinghbRebootTime
→Reboot does not repeat
Not monitoring heartbeat packets.
regardless of hbActionMax setting
debOlRebootTime
Outlet 2
"PC"
Scr&Reboot
Display
PC
Media
Player
Software
HeartBeat
Transmitter
(MRC-HB)
Rebooter
[RPC-M5C-EA]
Outlet 1
"Display"
Off following
Loading...
+ hidden pages