Meiko K-86, K-86E User Manual

K-86 SERIES
Exclusive Features:
Synchronized side-drive dual rack rail pawl-bar system ensures complete water coverage from every
angle, even the bottom of the rack
Large, insulated front doors are spring-loaded to open easily and STAY open, without latching
Computer-positioned wash arms in easily-removed manifolds. Arms and manifolds are stainless steel, eliminating high-wear gaskets and O-rings
Concave, slotted nozzles minimize clogging. Nozzles are computer-positioned at varying angles to maximize water coverage over all areas of the ware
Powerful 3hp pumps are 50% more powerful than the industry standard for outstanding cleaning
Large separation between wash and rinse (14” upper, 15” lower) avoids splashing of soiled water onto sanitized ware
Front-sloping tanks for complete drainage and easier cleaning
External, easily-operated lever drain system makes draining fast, safe and simple
HOT WATER SANITIZING
MULTIPLE-TANK
RACK CONVEYOR
WAREWASHERS
Standard Features:
ENERGY STAR Qualified
Water consumption 0.37 gallons per rack
All 304-series stainless steel construction
Double-wall insulated construction on front, top and back to improve operator safety, conserve heating energy, and reduce noise and heat loss into the dishroom
Large, easily-removed pan strainers with separate prewash scrap basket
Fully automatic operation including auto-fill and auto­start. Prewash, wash, recirculating rinse and final rinse are activated only when a rack is in place to conserve water and detergent
Powerful 3hp wash and recirculating rinse pumps are vertically-mounted to be self-draining and easily removed for servicing
Electromechanical controls for reliability and easy operation. Low-voltage 24VAC control circuit for operator safety
Easily accessible detergent and rinse aid injection ports for fast and easy chemical dispenser installation
Single-point electrical, water and drain connections. Internal booster heater option adds an additional terminal block for simpler replacement of an existing external booster heater
Low-level heater protection
Pressure reduction valve (machines with internal booster heater)
K-86 Series • Updated 8-10 MEIKO • 1349 Heil Quaker Blvd. • LaVergne, TN 37086 • (800) 55-MEIKO • FAX (615) 399-6620 • www.meiko.us
Options:
Choice of two clearance heights (standard 18” or tall hood 26”)
Internal booster heater (steam or electric heat)
External booster heater (steam or electric heat)
Master disconnect
External vent fan control
Table limit switch
Vent cowl collars
Direct drive sideloader
90° powered loader or unloaders
Flanged feet
Drain water tempering kit
Shock arrestor
Pressure reduction valve (machines without internal booster heater)
Models:
K-86E: 18” vertical clearance, electric heat
K-86S: 18” vertical clearance, steam coil heat
K-86ET: 26” vertical clearance, electric heat
K-86ST: 26” vertical clearance, steam coil heat
W
CR
S
W
D
CR
S
K-86 Series, left-to-right - electric heat w/o internal booster steam heat (all)OR
CR
(102mm)
7"
(178mm)
Table
lip-in height 2' 10"
(864mm)
9-5/8"
(244mm)
3-1/2" (90mm) recommended
4"
Control
panel
S
D
7’ 8-1/2” (2350mm)
1’ 11-1/8" (586mm)
5"
(127mm)
5-1/2"
(140mm)
CR
W
6-1/2"
(165mm)
Vent cowl
collar(s)
(optional)
4-3/4"
(121mm)
Drain
handle
8-1/8”
(205mm)
11" (280mm)
1" (25mm)
9-1/2”
(241mm)
3-1/8"
(80mm)
1' 3-1/2”
(395mm)
7-1/2"
(189mm)
8" (203mm)
Overall height,
doors
open
CR
D
Direction
of travel
1' 10" (559mm) 5' 4" (1625mm)
Table-to-table 7' 2" (2184mm)
Vent cowl collar centerline 7’ 11-1/2” (2426mm)
Overall 8' 6" (2591mm)
H
orizontal
clearance
1' 8-1/2" (520mm)
Vertical
clearance
3
1
Overall height,
doors
closed
4
Variable Dimensions
All dimensions from floor are +/- 1/2" due to adjustable feet.
Standard height machines
1
2
3
4
5
W,S
(405mm)
Tall hood machines
2' 2” (660mm)1' 6" (457mm)
5' 5-7/8" (1673mm)4' 9-7/8" (1471mm)
7' 11-7/8" (2435mm)6' 7-7/8" (2030mm)
6' 5-1/8" (2435mm)5' 9-1/8" (1756mm)
6' (1829mm)5' 4" (1626mm)
1' 4"
1' 8-1/2"
(521mm)
1' 2-3/4"
(374mm)
1' 3-1/2"
(395mm)
2' 6-1/4"
(768mm)
Wash section height,
doors closed
2
Drain
handle
K-86 Series • Updated 8-10 MEIKO • 1349 Heil Quaker Blvd. • LaVergne, TN 37086 • (800) 55-MEIKO • FAX (615) 399-6620 • www.meiko.us
D
Electrical
connection
5
Utility Connection Symbols
Utility ratings and connection specifications on Page 6.
S
W
CR
Drain
D W
Electrical
Ventilation
Water
Steam
S
Condensate return
CR
K-86 Series, right-to-left - electric heat w/o internal booster steam heat (all)OR
W
CR
S
CR
D
W
CR
1' 3-1/2”
(395mm)
9-1/2”
(241mm)
3-1/8"
(80mm)
Vent cowl
collar(s)
(optional)
(121mm)
Drain
handle
8-1/8”
(205mm)
11" (280mm)
4-3/4"
(165mm)
1" (25mm)
6-1/2"
S
W
CR
3’ 5-3/8" (1051mm)
5-1/2"
(140mm)
5"
(127mm)
Control
panel
7’ 8-1/2” (2350mm)
4"
(102mm)
(178mm)
D
9-5/8"
(244mm)
3-1/2" (90mm) recommended
7"
Table
lip-in height 2' 10"
(864mm)
2' 6-1/4" (768mm)
1' 2-3/4"
(374mm)
1' 3-1/2"
(395mm)
Overall height,
doors
open
3
1' 8-1/2"
(521mm)
clearance
1' 4"
(405mm)
Vertical
1
CR
W,S
H
orizontal
clearance
1' 8-1/2" (520mm)
Direction
of travel
5' 4" (1625mm)
Table-to-table 7' 2" (2184mm)
Vent cowl collar centerline 7’ 11-1/2” (2426mm)
Overall 8' 6" (2591mm)
Variable Dimensions
All dimensions from floor are +/- 1/2" due to adjustable feet.
Standard height machines
1
2
Overall height,
doors
closed
4
3
4
5
1' 10" (559mm)
Tall hood machines
2' 2” (660mm)1' 6" (457mm)
5' 5-7/8" (1673mm)4' 9-7/8" (1471mm)
7' 11-7/8" (2435mm)6' 7-7/8" (2030mm)
6' 5-1/8" (2435mm)5' 9-1/8" (1756mm)
6' (1829mm)5' 4" (1626mm)
D
7-1/2"
(189mm)
8" (203mm)
Wash
section
height,
doors
closed
2
Drain
handle
K-86 Series • Updated 8-10 MEIKO • 1349 Heil Quaker Blvd. • LaVergne, TN 37086 • (800) 55-MEIKO • FAX (615) 399-6620 • www.meiko.us
D
S
W
CR
Electrical
connection
5
Utility Connection Symbols
Utility ratings and connection specifications on Page 6.
Drain
D W
Electrical
Ventilation
Water
Steam
S
Condensate return
CR
Loading...
+ 5 hidden pages