Meiko CS70 User Manual

The clean solution
Special Features:
CS 70 - advanced microprocessor technology for
maintenance and end user dishmachine settings
Auto Prime - Timed priming function on all chemical pump s
T emp Safe - User-selectable temperature-based automatic drain/refill feature to ensure desired wash and rinse temperatures
Delime Cycle - Automatically fills machine, signals for
delimer, delimes for five minutes, then drains and rinses machine
Standard Features:
ENERGY STAR Qualified
LOW TEMPERATURE
CHEMICAL SANITIZING
DOOR-TYPE
DISHW ASHER
Water consumption 1.08 gallons (4.09 liters) per rack
V ariable programmed time cycles - 90 and 72 seconds
Fully automatic - automatic fill, automatic start, and automatic drain
Reversible accumulator drain for left or right connections
Stainless steel wash and rinse arms with removable end caps
Front-mounted controls with digital cycle and temperature displays
3/4 hp (0.56 kW) stainless steel self-draining wash/rinse pump
All 304 stainless steel construction for corrosion resistance
Wraparound door construction
Field-convertible for use in either straight-through or corner applications
Digital cycle counter
Type A air gap system eliminates need for vacuum breaker
Options:
False panel for corner and straight applications
Pumped drain for wall drain applications
Flanged, bolt-down feet
Proof of delivery window provides a visual indication that chemicals are being dispensed
Diagonal rack support
Page 1 • CS 70 • Updated 7-14 MEIKO • 1349 Heil Quaker Blvd. • LaVergne, TN 37086 • (800) 55-MEIKO • www.meiko.ussales@meiko.us
This dishwasher is compliant with the Reduction of Lead in Drinking Water Act (2011) amendment to the Safe Drinking Water Act (SDWA).
Dimensions Legend
7 7/8"
(200mm)
18 1/4" (464mm)
25 1/2" (648mm)
17 1/4" (438mm)
77 3/4" (1975mm)
W
59 3/16" (805mm)
W
D
1
D
2
D , D
12
11 1/4"
(284mm)
34" (845mm) table lip-in height
22 1/4" (565mm)
20 7/8" (530mm)
Electrical terminal block
Strain relief provided at lower rear of machine. Adequate slack in the wiring should be provided to allow the machine to be moved for servicing.
Fresh water connection
W
Requires hookup to 1/2" FNPT fitting.
Drain connection
D
1
required, either position may
or
be used)
D2
Requires indirect connection to 2" drain pipe (wall or floor). Gravity drain - must maintain downslope.
Machine is shipped with drain at position D . The machine may be be reconfigured (if required) at time of installation to use position D .
(one
1
2
D
1
25" (635mm) chassis
28 1/8" (715mm)
Closed 2 5/8" (66mm)
W
D
2
Open 3 3/8" (86mm)
13 1/4"
(335mm)
16 1/2" (419mm)
26 1/2" (673mm)
Max 29 7/8" (759mm)
20 5/8" (523mm)
Rack Clearances and Table Positioning
7" (178mm)
17" (432mm)
C
L
12 7/8"
(327mm)
20" (508mm)
rack clearance
2 7/8" (73mm)
12 1/2"
(318mm)
Rack centerline
C
L
12 1/2"
(318mm)
All dimensions from floor +/- 1/2"
Dishtabling shown for dimensional purposes only.All dishtabling to be provided by others.
(13mm) due to adjustable feet.
Page 2 • CS 70 • Updated 7-14 MEIKO • 1349 Heil Quaker Blvd. • LaVergne, TN 37086 • (800) 55-MEIKO • www.meiko.ussales@meiko.us