Meiji Techno MT-50 User Manual

Version No.: V1.2
07 Series
Biological Microscope Manual
Contents MT-50 Series
Before Use
1. Components ....................................................................................................................................... 1
2. Assembling ........................................................................................................................................ 5
2-1 Assembling Scheme ..................................................................................................................... 5
2-2 Assembling Steps ......................................................................................................................... 7
3. Operation........................................................................................................................................... 9
3-1 Set Illumination ........................................................................................................................... 9
3-2 Place the Specimen Slide ............................................................................................................. 9
3-3 Adjust the Focus .......................................................................................................................... 9
3-4 Adjust the Focusing Tension ...................................................................................................... 10
3-5 Adjust the Diopter ..................................................................................................................... 10
3-6 Adjust the Interpupillary Distance ............................................................................................ 10
3-7 Center the Condenser ................................................................................................................ 11
3-8 Adjust the Field Diaphragm ...................................................................................................... 11
3-9 Adjust the Aperture Diaphragm ................................................................................................ 12
3-10 Use the Oil Objective (100X) .................................................................................................. 12
3-11 Use the Filter ........................................................................................................................... 13
3-12 Replace the Fuse ..................................................................................................................... 13
3-13 Assemble and Use of the TV Device ........................................................................................ 13
3-14 Assemble the Photography Device .......................................................................................... 14
4. Assembling and Operation of Accessories ..................................................................................... 15
4-1 Assembling and Operation of Phase Contrast Flapper ............................................................. 15
4-2 Assembling and Operation of Disc Phase Contrast Condenser ................................................ 15
4-3 Assembling and Operation of Dark Field Flapper .................................................................... 16
4-4 Assembling and Operation of Simple Polarizing ...................................................................... 17
4-5 Operation of Digital Observation Head .................................................................................... 17
4-6 Assembling and Operation of the LED Fluorescence attachment ............................................. 17
5. Troubleshooting ............................................................................................................................ 200
Before Use MT-50 Series
1. Operation Notice
1. As the microscope is a high precision instrument, always operate it with care, and avoid physical shake during the operation.
2. Do not expose the microscope in the sun directly, either not in the high temperature, damp, dust or acute shake. Make sure the worktable is flat and horizontal.
3. When moving the microscope, use both hands to hold its back hand-clasping and the front base , and lay it down carefully (see Fig. 1).
It will damage the microscope by holding the stage, focusing knob or head when moving.
4. When working, the surface of condenser will be very hot. Make sure there is enough room for the heat dissipating around the condenser (see Fig. 2).
5. Connect the microscope to the ground to avoid lightning strike.
6. For safety, make sure the power switch is at “0” (off) and power it off before replacing the bulb or fuse, and wait until the lamp cools down (see Fig. 3).
Bulb selected only: 3.3V 3W LED (class
3Blight 6V 30W HAL.
7. Wide voltage range is supported as 100~240V. Additional transformer is not necessary. Make sure the voltage is in this range.
8. Use the special wire supplied by our company.
9. All power OFF devices have not been set in the
position where is difficult to operate.
Fig. 1
Fig. 2
Fig. 3
MT-50 Series
2. Maintenance
1. Wipe the lens gently with a soft tissue. Carefully wipe off the oil marks and fingerprints on the lens surfaces with a tissue moistened with a small amount of 3:7 mixture of alcohol and ether or dimethylbenzene.
As the alcohol and ether is flammable, don‟t place these chemical near to fire or fire
source. For example, when turning on or turning off the electrical device, please use these chemical in a ventilated place.
2. Don’t use organic solution to wipe the surfaces of the other components. Please use the neutral detergent if necessary.
3. If the microscope is damped by liquid when using, please power it off immediately and wipe it dry.
4. Never disassemble the microscope, otherwise the performance will be affected or the instrument will be damaged.
5. After using, cover the microscope with a dust cover.
3. Safety Sign
Sign
Signification
Study the instructions before use. Unsuitable operation would lead to person hurt or instrument faulty.
|
Main switch ON
O
Main switch OFF
-1-
1. Components MT-50 Series
Objective
Nosepiece
Arm
Tension Adjustment Ring
Coarse
Focusing
Knob
Fine Focusing
Knob
Light Adjustment Knob
Koehler Illuminator
Condenser
Binocular Head
Eyepiece
Objective
Stage
Koehler Illuminator
Condenser
Focus Arm
-2-
MT-50 Series
Eyepiece
Objective
Stage
Koehler Illuminator
Condenser
Light Source
Coarse Focusing
Knob
Power Switch
Fine Focusing
Knob
Focus Arm
Arm
Lock-screw
Trinocular head
Objective
Nosepiece
Koehler Illuminator
Condenser
-3-
MT-50 Series
LED Fluorescence Microscope
Eyepiece
Trinocular Head
LED Fluorescence
Illuminator
Filter Block
Adjustment knob
Light Shield
Objective
Stage
Koehler Illuminator
Condenser
Koehler Illuminator
Condenser
Light Source
Power Switch
Coarse Focusing
Knob
Objective Nosepiece
Arm
Focus Arm
Fine Focusing
Knob
Fluorescence
Light Adjustment
Knob
Lock-screw
LED Fluorescence
indicator
-4-
MT-50 Series
Binocular Head
LED Fluorescence Illuminator
Eyepiece
Objective
Nosepiece
Arm
Stage
Fine Focusing
Knob
Coarse Focusing
Knob
Light Adjustment
Knob
Focus Arm
Light Shield
Objective
Koehler Illuminator
Condenser
Koehler Illuminator
Condenser
LED Fluorescence
indicator
Loading...