1. Introduction
The Meiji Techno FL-PWJ Epi-Fluorescence Illuminator Power Supply is a precision engineered product incorporating efficient, silent-running switchmode power supply technology delivering smooth, regulated current.
The FL-PWJ Power Supply is designed only to support 100 watt HBO DC arc lamps.
The advanced switchmode design provides constant, low-noise DC power that automatically adjusts for the condition of the DC lamp in circuit.
The FL-PWJ Power Supply comes standard with a panel mounted circuit breaker and provides accidental unplug protection to guard against laboratory mishaps.
A panel mounted Elapsed Time Panel Meter keeps track of the DC arc lamp hours in use so replacements can be easily accommodated.
The reset button on the panel meter resets to “zero” when arc lamps are replaced.
This system was designed for easy plug-n-play integration with 100 watt HBO illumination commonly used in fluorescence microscopy work with no additional adjustments necessary for the lifespan of the arc lamp.
The FL-PWJ Power Supply can be used with the TC Series Inverted Epi­Fluorescence Microscope and comes standard on the MT6000 Series Epi­Fluorescence Upright Biological Models.
1.1 Power Supply & Lamphouse Features
Integrated Focusing Collector Lens in Lamphouse
Integrated Concave Mirror optimizes DC Arc Components
Solid State Switchmode Type Power Supply
Supports 100watt HBO Mercury DC arc lamps
Warm up time: ~ 2 minutes
Elapsed Time Meter
Power Supply & Lamphouse are Convection Cooled ( no fan noise )
Resetable Front Panel Breaker
Accidental Unplug Protection on Output
CE Approved, UL pending
1 year Conditional Warranty
Country of Origin: Japan
1.2 General Safety Guidelines
This manual contains important safety instructions and information concerning the installation, operation and maintenance of the FL-PWJ Power Supply.
This manual should be read carefully before any attempt is made to operate this equipment. To ensure safe operation the user must read and adhere to all of the directions put forth in this manual.
Meiji Techno products are designed for safe operation under normal operating conditions. The instrument and accessories described in this manual have been built and tested according to industry safety standards for electronic laboratory instruments. Incorrect usage or non-conformance to operating instructions can cause personal injury or damage to equipment or property.
Keep this manual near your instrument for easy reference.
1.3 Warning/Caution Symbols Used in this Manual
You must be aware of all safety issues when you install and operate this microscope system. Several warning and caution symbols are listed below.
These symbols are used throughout this instruction manual. For your safety, be sure to follow all instructions associated with the symbols listed below.
Disregarding instructions marked with this symbol may lead to
serious bodily injury or possibly death.
Operational warning; failure to operate equipment properly may
result in damage or injury.
Possible electrical shock hazard exists
Disregarding instructions marked with this symbol may lead to
serious injury or property damage.
Caution for heat or hot surfaces. Risk of burns or serious injury!
This symbol designates technical note or product tip.
1.4 Intended Product Use
Product Disclaimer: This product is designed and intended for use only as a
biological microscope illumination system. Modifying this product in any way for use in any situation other than the original and intended product design will automatically void the warranty. In no event shall Meiji Techno be liable to any person for any incidental, indirect or consequential damages, arising out of or in connection with the use or performance of a modified or altered product.
1.5 Product Safety Information
This product is not intended to be used in the immediate vicinity of water or a water outlet or placed in any location where water may penetrate the instrument. Water penetration may result in electrical shock or death. Choose only a suitable environment for your microscope.
Do not subject the product to extreme temperature fluctuations. Extreme temperature changes may lead to condensation within the unit which may result in damage to components.
Disassembly of the product may result in electrical shock, injury or death, equipment damage, loss of warranty coverage or may create other potential hazardous consequences.
Always turn off the power switch and disconnect the cord from the power supply when replacing fuses, connecting or disconnecting wiring, doing general maintenance or replacing the DC arc lamp.
DO NOT OPERATE UNLESS THE UNIT IS PROPERLY GROUNDED! Use only the specified power cord in a well grounded socket. Do not use in an
ungrounded power receptacle or in cases where there is a break in the ground conductor or damage to the electrical wiring.
Only fuses of the specified type and rating are to be used as replacements. Switch off the power and disconnect the power cord before replacing fuses. Use of a non-compliant fuse may result in electrical shock or severe damage your equipment.
The lamp and lamp house become extremely hot during and after operation. Do not place any highly flammable or volatile material close to the lamp-house during or after operation. Do not touch the lamp house or attempt to replace the bulb for at least 30 minutes after the unit has been turned off or injury may result.
Do not obstruct the air vents on the lamp-house or power supply. The lamp housing and power supply should must be located at least 10 cm (4 inches) away from the nearest wall or any combustible objects.
Modifying the product in any way or unauthorized attempts to disassemble or use the instrument for applications other then its intended design will automatically void the warranty.
1.6 Warranty Notes
Meiji Techno warrants this product against defects in material and/or workmanship for one year from the date of the original purchase to the original purchaser. Meiji Techno will repair or replace, at its option, any product which under normal conditions of use and service proves to be defective in material or workmanship. No charge will be made for labor or materials with respect to defects covered by this warranty, provided all repair work is done by Meiji Techno.
This warranty does not cover expenses incurred in the removal or reinstallation of any instrument or instruments, whether or not proven defective. Replacement or repairs
furnished under this warranty are subject to the same terms and conditions of the original warranty. This warranty supersedes any other warranty and is subject to the following terms and conditions:
WARRANTY
Warranty of Meiji Techno products extends to the original purchaser of the product and is not transferable.
WARRANTY DURATION
Meiji Techno warrants this product against defects in material and/or workmanship for the life of the product from the date of original purchase to the original purchaser. The electrical warranty is limited to one year.
OWNER’S REGISTRATION CARD
Return of the owner’s registration card by the original purchaser within ten (10) days after the original purchase is a condition precedent to coverage under this warranty. Meiji Techno will at its option accept written proof of purchase from the original owner in lieu of a product registration card.
EXCLUSIONS AND LIMITATIONS
Specifically excluded from this warranty are failures caused by abuse, neglect, misuse, improper operation, normal wear, accident, improper maintenance or modifications of ANY type. This warranty does not cover repair or replacement where normal use has exhausted the life of a part, product or instrument. All mechanical devices need periodic parts replacement and service to perform well. Service life of a product is dependent upon the care it receives and the conditions under which it has to operate. In no event shall Meiji Techno be liable for incidental or consequential damages.
SERVICE
To obtain service under this warranty, please contact Meiji Techno directly and ask for the Product Service Department. State the nature of the problem, model and serial number of the product, date of purchase and location and name of the distributor the instrument was purchased from. After verification of warranty registration, Meiji Techno will issue a return authorization number. Customer may then return the product postage prepaid and insured to the authorized repair facility.
In most instances, requests for warranty service will be performed in a prompt and routine manner and merchandise will be returned in a reasonable period of
time. In some cases, requests for warranty service are received which are not justified. In these cases, Meiji Techno will provide an explanation for non­warranty action.
WARRANTY TERMS
The terms of this warranty may not be varied by any person, whether or not purporting to represent or act on behalf of Meiji Techno. This warranty is provided is in lieu of any and all other warranties, expressed or implied, whether for merchantability or fitness for a particular purpose or otherwise. Liability for consequential damages under any, and all warranties are excluded to the extent exclusions are permitted by law. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. This warranty sets forth the customer’s exclusive remedy, with respect to defective products. This limited warranty shall become null and void in the event of a violation of the provisions of this limited warranty.
2.0 The Components
The image below designates the main components of the FL-PWJ Power Supply.