MEGUIAR'S A30 User Manual

A30, Deep Crystal® System Paint Cleaner (21-109A): A3016
__________________________________________________________________________________________
Page: 1 of 11
Safety Data Sheet
Copyright, 2012, Meguiar's, Inc. All rights reserved. Copying and/or downloading of this information for the purpose of properly utilising Meguiar's, Inc. products is allowed provided that: (1) the information is copied in full with no changes unless prior written agreement is obtained from Meguiar's, Inc., and (2) neither the copy nor the original is resold or otherwise distributed with the intention of earning a profit thereon.
26-8067-6
Version number:
3.02
Revision date:
20/04/2012
Supersedes date:
21/11/2011
Transportation version number: 1.00 (28/09/2010)
This Safety Data Sheet has been prepared in accordance with the REACH Regulation (EC) 1907/2006 and its modifications.
SECTION 1: Identification of the substance/mixture and of the company/undertaking
1.1. Product identifier
A30, Deep Crystal® System Paint Cleaner (21-109A): A3016
1.2. Relevant identified uses of the substance or mixture and uses advised against
Identified uses
Automotive.
1.3. Details of the supplier of the substance or mixture Address:
Meguiars United Kingdon Limited, 3 Lamport Court, Heartlands, Daventry, Northants, NN11 8UF
Telephone:
+44 (0)870 241 6696
E Mail:
info@meguiars.co.uk
Website:
www.meguiars.co.uk
1.4. Emergency telephone number
+44 (0)870 241 6696
SECTION 2: Hazard identification
2.1. Classification of the substance or mixture
Dangerous substances(67/548/EEC)/preparations(1999/45/EC) directive
2.2. Label elements
Dangerous substances(67/548/EEC)/preparations(1999/45/EC) directive
Symbols None.
Contains:
No ingredients are assigned to the label.
A30, Deep Crystal® System Paint Cleaner (21-109A): A3016
__________________________________________________________________________________________
Page: 2 of 11
Risk phrases
R66 Repeated exposure may cause skin dryness or cracking.
Safety phrases
S2 Keep out of the reach of children.
Notes on labelling
R65 is not required on the label due to the product's viscosity. Updated per Regulation (EC) 648/2004 on detergents. Ingredients required per 648/2004: 15-30%: Aliphatic hydrocarbons; <5%: Non-ionic surfactant. Contains: Methylchloroisothiazolinone, methylisothiazolinone. Nota N applied to CASRN 64742-46-7.
2.3. Other hazards
None known.
SECTION 3: Composition/information on ingredients
Ingredient CAS Nbr EU Inventory % by Wt Classification
Non-hazardous ingredients Mixture 50 - 70 Solvent naphtha (petroleum), medium aliphatic
64742-88-7 EINECS 265-
191-7
10 - 30 Xn:R65 - Nota 4 (EU)
R10; R66; R67 (Self Classified)
Asp. Tox. 1, H304 (CLP) Flam. Liq. 3, H226; STOT SE 3, H336; EUH066 (Self Classified)
Distillates (petroleum), hydrotreated middle 64742-46-7 EINECS 265-
148-2
7 - 13 Nota N (EU)
Xn:R20-65; R66 (Self Classified)
Nota N (CLP) Acute Tox. 4, H332; Asp. Tox. 1, H304; STOT SE 3, H336; EUH066 (Self Classified)
Glycerin 56-81-5 EINECS 200-
289-5
3 - 7
Processed oil Trade Secret 1 - 5
Conditioners Trade Secret < 5 Please see section 16 for the full text of any R phrases and H statements referred to in this section Please refer to section 15 for the any applicable Notas that have been applied to the above components
For information on ingredient occupational exposure limits or PBT or vPvB status, see sections 8 and 12 of this SDS
SECTION 4: First aid measures
4.1. Description of first aid measures
Eye contact
Flush with large amounts of water. Remove contact lenses if easy to do. Continue rinsing. If signs/symptoms persist, get medical attention.
Skin contact
Wash with soap and water. If signs/symptoms develop, get medical attention.
A30, Deep Crystal® System Paint Cleaner (21-109A): A3016
__________________________________________________________________________________________
Page: 3 of 11
Inhalation
Remove person to fresh air. If you feel unwell, get medical attention.
If swallowed
Rinse mouth. If you feel unwell, get medical attention.
4.2. Most important symptoms and effects, both acute and delayed
See Section 11.1 Information on toxicological effects
4.3. Indication of any immediate medical attention and special treatment required
Not applicable
SECTION 5: Fire-fighting measures
5.1. Extinguishing media
In case of fire: Use a fire fighting agent suitable for flammable liquids or gases such as dry chemical or carbon dioxide.
5.2. Special hazards arising from the substance or mixture
Closed containers exposed to heat from fire may build pressure and explode.
Hazardous Decomposition or By-Products
Substance Condition
Hydrocarbons. During combustion. Carbon monoxide. During combustion. Carbon dioxide. During combustion. Irritant vapours or gases. During combustion.
5.3. Advice for fire-fighters
Water may not effectively extinguish fire; however, it should be used to keep fire-exposed containers and surfaces cool and prevent explosive rupture.
SECTION 6: Accidental release measures
6.1. Personal precautions, protective equipment and emergency procedures
Ventilate the area with fresh air. For large spill, or spills in confined spaces, provide mechanical ventilation to disperse or exhaust vapours, in accordance with good industrial hygiene practice. Warning: A motor could be an ignition source and could cause flammable gases or vapours in the spill area to burn or explode.
6.2. Environmental precautions
Avoid release to the environment.
6.3. Methods and material for containment and cleaning up
Contain spill. Working from around the edges of the spill inward, cover with bentonite, vermiculite, or commercially available inorganic absorbent material. Mix in sufficient absorbent until it appears dry. Remember, adding an absorbent material does not remove a toxic, corrosivity or flammability hazard. Collect as much of the spilled material as possible. Place in a closed container approved for transportation by appropriate authorities. Seal the container. Dispose of collected material as soon as possible. Clean up residue with detergent and water.
6.4. Reference to other sections
Refer to Section 8 and Section 13 for more information
SECTION 7: Handling and storage
7.1. Precautions for safe handling
A30, Deep Crystal® System Paint Cleaner (21-109A): A3016
__________________________________________________________________________________________
Page: 4 of 11
Vapours may travel long distances along the ground or floor to an ignition source and flash back. Keep out of reach of children. Avoid breathing dust/fume/gas/mist/vapours/spray. Do not get in eyes, on skin, or on clothing. Do not eat, drink or smoke when using this product. Wash thoroughly after handling. Avoid contact with oxidising agents (eg. chlorine, chromic acid etc.)
7.2. Conditions for safe storage including any incompatibilities
Store away from acids. Store away from oxidising agents. Store in a well-ventilated place. Keep container tightly closed.
7.3. Specific end use(s)
See information in Section 7.1 and 7.2 for handling and storage recommendations. See Section 8 for exposure controls and personal protection recommendations.
SECTION 8: Exposure controls/personal protection
8.1 Control parameters
Occupational exposure limits
Ingredient CAS Nbr Agency Limit type Additional comments
Glycerin 56-81-5 Health and
Safety Comm. (UK)
TWA(as mist):10 mg/m3
Health and Safety Comm. (UK) : UK Health and Safety Commission TWA: Time-Weighted-Average STEL: Short Term Exposure Limit ppm: parts per million mg/m³: milligrams per cubic metre CEIL: Ceiling
8.2. Exposure controls
8.2.1. Engineering controls
Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below relevant Exposure Limits and/or control dust/fume/gas/mist/vapours/spray. If ventilation is not adequate, use respiratory protection equipment.
8.2.2. Personal protective equipment (PPE)
Eye/face protection
The following eye protection(s) are recommended: Safety glasses with side shields.
Skin/hand protection
Gloves made from the following material(s) are recommended: Neoprene. Nitrile rubber.
Respiratory protection
Wear respiratory protection if ventilation is inadequate to prevent overexposure. Select one of the following approved respirators based on airborne concentration of contaminants and in accordance with regulations: Half facepiece or full facepiece air-purifying respirator suitable for organic vapours and particulates
SECTION 9: Physical and chemical properties
9.1. Information on basic physical and chemical properties
Loading...
+ 7 hidden pages