Megger TDR500 Operating Manual

Mechanical
he instrument is designed for use indoors or outdoors and is
T rated to IP54.
OPEN CONDUCTOR
TDR500 User Guide
Case Dimensions 230mm long (9 inches)
Instrument Weight 0.6kg (1.32lbs)
Case Material ABS
Connectors BNC Terminal
Test Lead 300mm long with croc clips.
Display 122 x 32 pixel Graphics LCD.
Environmental
Operational Temperature -15OC to +50OC
Storage Temperature -20
Ordering Information
TDR 500
Included Accessories
Test & Carry case with strap 6420-125 Lead Set 6231-694 User Guide 6172-726
Megger Limited Archcliffe Road, Dover Kent CT17 9EN England T +44 (0)1 304 502101 F +44 (0)1 304 207342 E uksales@megger.com
Megger 4271 Bronze Way, Dallas, Texas 75237-1019 USA T +1 800 723 2861 (USA T +1 214 333 3201 F +1 214 331 7399 E ussales@megger.com
115mm wide (4.5 inches)
8mm deep (2 inches)
4
O
(5
F to 122OF)
O
C to 70OC
O
(-4
F to 158OF)
Megger Z.A. Du Buisson de la Couldre 23 rue Eugène Henaff 78190 TRAPPES France T +33 (0)1 30.16.08.90 F +33 (0)1 34.61.23.77 E infos@megger.com
ONLY)
SHORTED CONDUCTOR
SPLICE
BRIDGE TAP
SPLIT/ RESPLIT
WET SPLICE/ WATER
FRAYED CABLE
WATER INGRESS
TAP
TIME DOMAIN REFLECTOMETER
TYPICAL CABLE VELOCITY FACTORS
Main Type
Twisted Pair
Co-ax
Plc
Gel filled
This instrument is not to be used on
The instrument should not be used if any part
Disconnect the test leads before accessing
Refer to operating instructions for further
Safety Warnings and Precautions must be read
NOTE: THE INSTRUMENT MUST ONLY BE USED BY
Sub Type Velocity Factor
Polyethylene Jelly Filled Polyethylene PTFE (Teflon) Paper (Pulp 0.083uf/mile) Paper (Pulp 0.072uf/mile)
Foam Polyethylene Air Spaced Co-axial Air Solid Polyethylene
0.67
0.64
0.71
0.72
0.88
0.82
0.94
0.98
0.67
TELECOMMUNICATIONS CABLES
19 AWG 0.72 22 AWG 0.67 24 AWG 0.66 26 AWG 0.65
19 AWG 0.68 22 AWG 0.62 24 AWG 0.60 26 AWG 0.58
Pulp
Service Wire
22 AWG 0.67/0.71
SAFETY WARNINGS
energised cable.
of it is damaged.
the battery compartment.
explanation and precautions.
and understood before the instrument is used.
must be observed during use.
They
SUITABLY TRAINED AND COMPETENT PERSONS
24 AWG 0.68 26 AWG 0.66
0.64
This instrument is manufactur The company r without prior notice.
Megger is a registered trademark
Part No 6172-726 V02 Printed in England 1105 www.megger.com
eserves the right to change the specifi
ed in the United Kingdom.
cation or design
SPLITTER
Megger Limited Archcliffe Road, Dover Kent CT17 9EN England T +44 (0)1 304 502101 F +44 (0)1 304 207342 E uksales@megger.com
VF
232.1m
0.67R
VF
SPECIFICATION
xcept where otherwise stated, this specification applies at an
E ambient temperature of 20
General
O
C.
+
Battery State Indicator
Blinking signal gives the warning of low battery indicating when the battery volts drop to 6.5V.
Cursor Position
This indicates the current cursor position in metres or feet.
Velocity Factor Indicator
Indicates the current velocity factor as either a ratio of the speed of light (R), or as m/µs
µs.
or ft/
Menu
The menu allows the units of the distance and velocity factor to be changed.
To enter the menu, switch the instrument on holding down the warble key.
To change the displayed units, press one of the velocity factor keys. The options available are m and Ratio, m and m/us, ft and Ratio and ft and ft/us.
When selected, either switch the instrument off, or press the warble key to start testing.
Cursor Left
This control moves the cursor to the left.
Range
This is a bi-directional range control. Press the left side to decrease the gain, right side to increase.
Cursor Right
This control moves the cursor to the right.
Power
Pressing this button will turn the instrument on or off depending on the current state.
Velocity Factor
Use this key to change the velocity factor to a suitable value for the cable under test.
Warble
Press to select the warble functions, or to return to TDR functions. Warble function can be used to trace cables.
Ranges 30m, 100m, 300m, 1000m, 3000m.
ccuracy ± 1% of range ± pixel at 0.67VF
A
Resolution 1% of range.
Input Protection For connection to unenergised cable
Output Pulse 5 volts peak to peak into open circuit
Gain Automatic with gain and range.
Velocity Factor Variable from 0.01 to 0.99
Refresh Rate Three times a second.
Power Down Automatic after 5 minutes
Warble 5V pk-pk from 100, alternating
Batteries Six LR6 (AA) type batteries,
Nominal Voltage 9V for Alkali or 7.2V for NiCad.
Battery Consumption 100mA nominal.
(100ft, 300ft, 1000ft, 3000ft, 10,000ft.)
Note:- the measurement accuracy is
[ for the indicated cursor position only and is conditional on the velocity factor being correct.]
only.
from 100source. Pulse widths determined by range and cable impedance.
in steps of 0.01.
with no key press.
between 810Hz and 1110Hz.
Manganese-alkali or nickel-cadmium or nickel-metal-hydride cells.
(30 hours’ continuous use.)
Safety This instrument is to be used on
unenergised cable only
EMC Complies with Electromagnetic
Compatibility Specifi (Light industrial) BS EN 61326-1,with a minimum performance of ‘B’ immunity tests.
.