KC SERIES LEAD SETS
Wind turbine lightning protection test leads sets
KC series test leads
Wind turbine lightning protection test lead sets
n Developed in conjunction with a leading
manufacturer of wind turbines
n Allows easy and reliable measurement of
lightning protection circuit resistance of
wind turbines
n Available in three lengths, 30 m, 60 m
and 100 m to suit both manufacturing
and maintenance applications
n Long cable fitted on strong metal framed
cable reel
n Cable reel fitted with friction brake to
avoid tangles when paying out cable
emfs
DESCRIPTION
The KC series of test leads provide a complete and
convenient solution to the problem of finding reliable test
leads that are long enough for testing the continuity of
lightning protection conductors in wind turbines.
KC-series wind turbine test leads are available in 100 m,
60 m and 30 m versions that are equally suitable for use on
site or in the manufacturing plant. All lead set versions are
10 A rated.
The lead sets consist of two test leads. The first is a 5 m cable
fitted with a duplex handspike for probing the lightning
receptors on the tips of the turbine blades. The second cable
is either, a 30 m, 60 m or 100 m cable, fitted with a large
robust Kelvin clip, specially designed to offer ease of use
while providing the consistently reliable connections needed
to ensure accurate and repeatable test results.
The long cable is wound onto a high quality, robust cable reel
fitted with a friction brake to avoid tangles whilst paying out.
ORDERING INFORMATION
Product Order Code
KC100 Kelvin lead kit (1 x 100 m / 1 x 5 m) 1000-809
KC60 Kelvin lead kit (1 x 60 m / 1 x 5 m) 1001-248
KC30 Kelvin lead kit (1 x 30 m / 1 x 5 m) 1001-249
ADDITIONAL FEATURES AND BENEFITS
n Hook terminations marked with C or P to assist in
making the correct connections
n Duplex handspikes has a compress and rotate action to
ensure good connection to lightning receptors
n Cable guide on cable reel to assist with neat re winding
n Light weight, even 100 m long KC100 lead set is less
than 15 kg
APPLICATIONS
This lead set is intended to measurement the resistance of
the lightning protection circuit of a wind turbine, either in
part in a production environment, or fully assembled during
commissioning, maintenance, or following repair. This lead
set is designed to be connected to any instruments in the
Megger 10 A DLRO range or the Megger BT51. However,
for outside use the DLRO10HD is recommended due to it
robustness and high IP rating.
Lead resistance
KC30 250 mΩ
KC60 500 mΩ
KC100 900 mΩ
UK
Archcliffe Road Dover
CT17 9EN England
T +44 (0) 1304 502101
F +44 (0) 1304 207342
UKsales@megger.com
UNITED STATES
4271 Bronze Way
Dallas TX 75237-1019 USA
T 800 723 2861 (USA only)
T +1 214 333 3201
F +1 214 331 7399
USsales@megger.com
OTHER TECHNICAL SALES OFFICES
Valley Forge USA, College Station USA, Sydney
AUSTRALIA, Täby SWEDEN, Ontario CANADA,
Trappes FRANCE, Oberursel GERMANY, Aargau
SWITZERLAND, Kingdom of BAHRAIN, Mumbai
INDIA, Johannesburg SOUTH AFRICA, Chonburi
THAILAND
CERTIFICATION ISO
Registered to ISO 9001:2008 Cert. no. Q 09250
Registered to ISO 14001-2004 Cert. no. EMS 61597
KC_TEST_LEADS_DS_EN_V03
www.megger.com
Megger is a registered trademark