Megger High Pot Testers Data sheet

AC and AC/DC
High-pot Testers
Rapid production line testing to latest UL standards
Extra safety features
Rugged design for ease of portability
High-Pot Testers
DESCRIPTION
AC and AC/DC High-Pot Testers available from Megger are designed for safety and ease of operation, and readily adapt to development, maintenance or production testing. Three models are available: two ac and one ac/dc. The AC High-Pot Testers feature a front-panel, NEMA 5-15R three-prong output receptacle. Booted, alligator-clip output and return probes are also supplied with all models.
Test voltage is continuously adjustable from zero to full output, with a zero-start interlock. Leakage current trip level may be adjusted from 0.3 to 12 mA by a front-panel knob. Pushbuttons are provided to select one-second or continuous testing, to turn off the high voltage and to reset the instrument. All high-voltage connections are recessed to prevent accidental contact with high voltage.
During testing, high voltage will automatically shut down within 50 ms of arcing or exceeding the preset trip level. Visual and audible alarms alert the operator upon failure.
The instruments also feature an interlock that prevents the high voltage from being applied if the supply ground wire is open or if the hot and neutral wires are interchanged. A Tester Grounded lamp lights to confirm the instrument is connected to a properly grounded power source.
The AC High-Pot Testers will automatically shut down if ground circuit resistance of the test object exceeds 15 ohms at any time during testing. This feature may be bypassed when testing double-insulated devices or when using test probes. The AC/DC High-Pot Tester provides a slide switch to select either ac or dc test voltage. The slide switch safely covers the output jacks not in use.
APPLICATIONS
These portable instruments are used to test the dielectric strength of electrical insulation and the ground circuit continuity of three-wire appliances and other devices. Biddle High-Pot Testers comply with most existing UL requirements for dielectric withstand testing, including:
UL 544 – Electric Medical and Dental Equipment
UL 982 – Motor-Operated Household Food Preparing Machines
UL 1026 – Electric Household Cooking and Serving Appliances
UL 1270 – Radio Receivers, Audio Systems, and Accessories
FEATURES AND BENEFITS
Ground continuity check of three-wire devices with high-voltage interlock (ac models only)
Front-panel adjustable leakage current trip from 0.3 to 12 mA
One-second or continuous testing
Automatic failure shutdown, with visual and audible alarms
Recessed high-voltage connections
Front-panel NEMA 5-15R three-prong receptacle on ac models
Zero start/reset in event of failure
Meets UL 120-kΩ requirement
High-pot Testers
Input
Standard: 120 Vac ±10%, 1 A, 50/60 Hz Optional: Nominal 230-Vac, 50/60-Hz line is available on all models
at no additional charge. To order, add –47 to Cat. No.
Output
Maximum Output Current: 12.6 mA Wave Shape
AC Models: Line AC/DC Model: Maximum ripple 0.4% rms per mA at full
voltage
Accuracy
Applied Test Voltage: ±2% Leakage Current: ±5%
SPECIFICATIONS
Optional pistol-grip leads
AC High-pot Tester with supplied leads
CAT. NO. Model Applied Test Adjustable Leakage Output Dimensions Weight
Voltage Current Trip L evel Receptacle
230315 0 to 3 kV 12.5 lb
(5.6 kg)
230415 0 to 4 kV
0 to 4 kV AC: 0.3 to 12 mA 13.5lb
0 to 5 kVdc DC: 0.43 to 17 mA (6.1 kg)
AC
AC/DC
0.3 to 12 mA
Front-panel
NEMA5-15R
8 H x 9 W x 8.4 D in.
20.6 H X 23 W X 21 D cm
230425
High-pot Testers
OUTPUT VOLTMETER
gives 2% accuracy traceable to NIST (certificate available).
FAILURE LAMP
lights when failure is detected; buzzer sounds, output trips off.
PUSHBUTTON
for ONE-SECOND HIGH-VOLTAGE TEST
HIGH-VOLTAGE TEST PUSHBUTTON
for timed tests
VOLTAGE CONTROL SAFETY INTERLOCK requires voltage control
be reset to zero before test leads can again
be energized.
TESTER GROUNDED
LAMP
lights when tester is connected to properly wired supply.
OUTPUT VOLTMETER
gives 2% accuracy traceable to NIST (certificate available).
PUSHBUTTON
for ONE-SECOND HIGH-VOLTAGE TEST
HIGH-VOLTAGE TEST PUSHBUTTON
for timed tests
VOLTAGE CONTROL SAFETY INTERLOCK requires voltage control
be reset to zero before test leads can again be energized.
AC High Pot Testers
AC/DC High Pot Testers
High-pot Testers
Item Cat. No.
AC High-Pot Testers 0 to 3 kV 230315 0 to 4 kV 230415 AC/DC High-Pot Tester, 0 to 4 kV ac/5 kV dc 230425
Included Accessories
Test probes with alligator clips for ac models, includes one Cat. No. 25507 high-voltage probe and one Cat. No. 25136 return probe, 4 ft [1.2 m]; for ac/dc models, includes one Cat. No. 25149 complete assembly, 4 ft [1.2 m]
Power cord 17032 Instruction manual for 230315 & 230415 AVTM23-1J Instruction manual for 230425 AVTM23-4J
Optional Accessories
Test probes with retractable tips, 4 ft [1.2 m] High-voltage probe for ac models only 230315-2 Return probe for ac models only 230315-3 High-voltage and return probe set for ac/dc model only 230425-2 Adapters, for conversion of output receptacles for use with twist-lock plugs NEMA L5-15R twist lock 235300-1 NEMA L5-20R twist lock 235300-2 NEMA L5-30R twist lock 235300-4
ORDERING INFORMATION
UK
Archcliffe Road Dover CT17 9EN England T +44 (0) 1304 502101 F +44 (0) 1304 207342
UNITED STATES
4271 Bronze Way Dallas TX75237-1088 USA T 800 723 2861 (USA only) T +1 214 330 3203 F +1 214 337 3038
OTHER TECHNICAL SALES OFFICES
Valley Forge USA, Toronto CANADA, Mumbai INDIA, Trappes FRANCE, Sydney AUSTRALIA, Madrid SPAIN and the Kingdom of BAHRAIN.
Registered to ISO 9001:2000 Reg no. Q 09290 Registered to ISO 14001 Reg no. EMS 61597