Megger DCM310, DCM320 Operating Manual

DCM310 Clampmeter User Guide
Warning
Safety sheet
. . . . . . . . . .
. . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . .
. . . . . . . . .
Read First
Safety Information
To ensure safe operation and service of the Meter, follow these instructions. Failure to observe warnings can result in severe injury or death.
- Avoid working alone so assistance can be rendered.
- To enhance safety, test leads should be disconnected from instrument when not in use.
- Do not use test leads or the Clamp Meter if they look damaged.
- Do not use the Meter if the Clamp Meter is not operating properly or if it is wet.
- Use the Clamp Meter only as specified in the Instruction card or the protection provided by the Clamp Meter might be impaired.
- Special precautions are necessary when operating in situations where exposed live parts at dangerous voltages may be encountered. Personal protective equipment (not supplied with this instrument) should be used.
Symbols as marked on the Tester and Instruction card
Risk of electric shock
See instruction card
Equipment protected by double or
reinforced insulation Battery
Earth
Conforms to EU directives
Application around and removal
F
from hazardous live conductors is permitted
Do not discard this product or throw away
Power On / Off ACA 20A
Data Hold MAX Hold
CAT.Ⅲ.600V with respect to
earth for the jaw. Tactile barrier for
Hand Guard. Do not hold the
1.3V ~ 750.0V
meter in front of the Tactile Barrier.
X
Maintenance
Do not attempt to repair thi s C lam p M eter. It contains no user-servicea ble p arts. Repair or serving should only be performed by qualified personal .
Cleaning
Periodically wipe the case with a dry cloth and detergent do not use abrasives or solvents.
ACA 200A
CAT.Ⅲ.600V with respect to
earth for the jaw. Tactile barrier for
Hand Guard. Do not hold the
meter in front of the Tactile Barrier.
X X
Battery Replacement
ACA 400A
CAT.Ⅲ.600V with respect to
earth for the jaw. Tactile barrier for
Hand Guard. Do not hold the
meter in front of the Tactile Barrier.
Specifications
1-1 General Specifications
LCD display digits :
2000 digit large scale LCD readout.
Measuring rate : 2.5 times / sec. Overrange display :
“OL” is displayed for “20A” and “200A” range, shows the real value when bigger than “400A” range.
Low battery indicator :
is displayed. Replace the battery when the indicator appears in the
display.
Power requirement :
9V PP3/6LR61 battery.
Battery type and life :
ALKALINE 580 hours. Rechargeable batteries are not suitable for use with this instrument.
1-2 Environmenta l Conditions
Indoor Use. Calibration :
One year calibration cycle.
Operating temperature :
0°C ~ 30°C (80% RH) 30°C ~ 40°C (75% RH) 40°C ~ 50°C (45%RH)
Storage temperature :
-20 to +60°C, 0 to 80% RH (batteries not fitted).
Operating altitude : 2000m (6562 ft) Overvoltage category :
IEC 61010-1 600V CAT., CAT. equipment is designed to
protect against the transients in the equipment in fixed installations, such as distribution panels, feeders and short branch circuits and lighting systems in large buildings.
Conductor Size : 27mm diameter. Pollution degree : 2 EMC : EN 61326-1 Shock vibration :
Sinusoidal vibration per MIL-T­28800E (5 ~ 55 Hz, 3g maximum).
Dimensions (W x H x D) :
56mm x 180mm x 32mm
Weight : 250g including battery. Accessories : Battery (installed),
Carrying case and User manual.
1-3 Electrical Specifications
Accuracy is ± (% reading + number of digits) at 23°C ± 5°C < 80%RH.
Temperature coefficient :
0.2 x (Specified accuracy) / °C, < 18°C, > 28°C.
AC Cur rent
Function Range Accuracy
A
(50~60Hz)
0 ~19.99A
20.00~199.9A 200~400A
±(3.0% + 0.05 A) ±(2.0% + 0.5 A) ±(2.0% + 5 A)
Limited Warranty
This Meter is warranted to the orig ina l purchaser against defects in material and workmanship for 1 year from the date of purchase. During th is wa rranty period, manufacturer will, a t its optio n, replace or repair the defective unit, subject to verification of the d efe ct or malfunction. This warranty does not cover disposa ble ba t teries , or da mage from abuse, neglect, accident, unauthorized repair, altera tion, contamination, or abnormal conditions of operation or handling. Any implied warranties arising out of the sale of this product, including but not limited to implied war ranties of merchantability and fitness for a particular purpose, are limited to the above. The manufacturer shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expense or economic loss. Some states or countries law s vary, so the above limitations or exclusions may not apply to you.
Megger Limited
Archcliffe Road, Dover, CT17 9EN United Kingdom Tel +44 (0) 1304 502100
Valley Forge Corporate Centre 2621 Van Buren Avenue, Norristown PA 19403, USA Tel +1-979-690-7925
Email sales@megger.com Web www.megger.com